HomeMy WebLinkAbout3304-7TOP OF WALL WALL OR FENCE
SCREW OR BOLT -AS
CONDITIONS REQUIRE PLANTING NOTES
5' -0' 10 GA, STAINLES
STEEL WIRE WEED CONTROL
+ CONCRETE PAVING, CURB OR WALL 4 WHERE PERENNIAL WEEDS EXIST ON SITE AT THE BEGINNING OF WORK, CLEAN AND REMOVE
ROOTBARRIER REQUIRED FOR TREES I THESE EXISTING WEEDS BY MOWING OR GRUBBING OFF ALL PLANT MATERIAL. UPON
PLANTED 5' OF HARDSCAPE ° r / COMPLETION OF SOIL PREPARATION AND PLANTING OF ALL SPECIMEN TREES, BEGIN WEED
MAX. L
ROOTBALL / ABATEMENT PROGRAM BY APPLYING: 100 POUNDS OF A COMMERCIAL FERTILIZER, 46-0-0, PER
.' FINISH GRADE STAINLESS STL,
ACRE AND PER MANUFACTURERS SPECIFICATIONS. WATER ALL AREAS FOUR (4) TIMES DAILY
�1 r I WASHER -AS FOR FOURTEEN (14) CONSECUTIVE DAYS UNTIL WEED SEEDS HAVE GERMINATED. CEASE
4 Ile,CONDITIONS WATERING FOR THREE (3) DAYS. SPRAY A NON-SELECTIVE, NON -RESIDUAL, SYSTEMIC
3' BERM TO FORM N REQUIRE HERBICIDE TO ERADICATE GERMINATED WEEDS. LET THE WEEDS DIE WITHOUT IRRIGATION
PERMANENT BASIN WATER BASINlz_FOR A MINIMUM DEPTH OF 1 /4"INCH BELOW THE SURFACE OF THE SOIL. IF STUBBORN AND
= SOIL BACKFILL MIX RESIDUAL WEEDS (I.E. BERMUDA) SHOULD PERSIST ERADICATION PROCEDURE SHOULD BE
REPEATED. THE TYPE OF WEEDS THAT EXIST SHOULD BE IDENTIFIED AND COORDINATED WITH
I FERT I L I ZER TABLETS 6'-24'x.08"MI THA. RAL CONTROL BARRIER AN APPROVED LICENSED PEST CONTROL ADVISOR TO ENSURE COMPATIBILITY WITH CHEMICAL.
-I I.II • d -I ( ___ 6'-0" MIN. LATERAL EXTENSION FROM ° � Q � �
• III: CENTER OF TREE TRUNK ADJACENT QO WONDER TIE OR AND SEASON OF APPLICATION. DO NOT USE MATERIAL OR METHOD THAT WOULD ADVERSELY
70 HARDSCAPE, FASTEN JOINTS, n EFFECT NEW PLANTINGS, SLOPE STABILIZATION OR HYDROSEEDING.
EQUAL -AS NEEDED
.I I , .
1 1/2'X MIN, ROOTBALL DEP ROOTBALL RIB INWARD. � - - _ =1 BACKFILL 1 MIX,
2X THE WIDTH OF R❑❑TBALL EOESPALIERED PLANTIL BATE AND RECOMPACT oD SOIL TEST
PUDDLE AND SETTLE BACKF I L BACKFILL OR VINE AFTER ALL SOIL HAS BEEN IMPORTED TO THE SITE AND ROUGH GRADING COMPLETED BUT
PRIOR TO PLACEMENT OF SHRUB PER SPECS PRIOR TO SOIL PREPARATION, THE CONTRACTOR SHALL FURNISH A COPY OF THE SOIL TEST FOR
AGRICULTURAL SUITABILITY AND FERTILITY (PREPARED BY A CALIFORNIA ASSOCIATION OF
w ¢ AGRICULTURAL LABORATORIES MEMBER) TO THE CONTRACTING OFFICER.
NOTE UPON REVIEWING THE SOILS REPORT THE CONTRACTING OFFICER MAY MAKE SPECIES
o PAINT BOLT OR SCREW TO SUBSTITUTIONS TO THE PLANT LIST.
Cz
MATCH SURFACE BEHIND
SHryRUB PLANTING ROOT BARRIER 2X t SOIL PREPARATION
ROOTBALL
MACHINE ROTOTILL THE FOLLOWING AMENDMENTS INTO THE SOIL AT RATES INDICATED PER
ELEVATION VIEW 1000 SF: (THESE RATES ARE FOR BID PURPOSES ONLY, ACTUAL RATES TO CORRESPOND TO
CONTRACTOR'S SOILS REPORT).
4' O.C. 4 CU. YDS NITROGEN STABILIZED SAWDUST
SHINGLE NAIL 150 LBS. GYPSUM
WALL 125 LBS STANDARD FERTILIZER
LODGE POLE
61X8' CONCRETE VINE COLLARS
IN TURF AREAS ONLY DEEP ROOT BARRIERS
TREE TRUNK ALL TREES WITHIN 5 FEET OF ANY PERMANENT HARDSCAPE ELEMENT SUCH AS CONCRETE
WALKS, WALLS OR BUILDINGS SHALL BE PLANTED WITH AN APPROPRIATE SIZED ROOT
CINCH T I E ti�
(DO NOT TWIST) BARRIER (UNLESS OTHERWISE NOTED ON PLANS).
PREVAILING WIND WALK-ON BARK
DIRECTION
\ N 00 PLAN VIEW ALL SHRUB AND GROUNDCOVER AREAS EXCEPT FOR HYDROSEEDED AREAS, D.G. GRAVEL
AREAS OR SLOPES IN EXCESS OF 4:1 SHALL BE TOP DRESSED WITH A 1" LAYER OF I" DIAMETER
24" 0 C.L WALK ON BARK (SUBMIT SAMPLE FOR APPROVAL)
C' DIA LODGEPOLE PINE TREE
STAKE COPPER NAPTHENATE VINE PLANTING
TREATED AND DRIVEN IN GROUND SIDEWALK OR TRAIL
TO 2FT. MIN, DEPTH, 2 REQ' D
'
CINCH TIE' ( 4) REQ' D
z 9„ ARBOR GUARD IN TURF AREAS
I-' PREPARED BACKFILL MIX,
S SEE SPECIFICATIONS
3' HIGH WATER BASIN, STREET TRIM 1/3 OF FRONDS
AT TIME OF PLANTING
FINISH GRADE TRIM FOR UNIFORMITY
TYPICAL GROUNDCOVER
-III= --III III
_=III- AGRIFORM TABLETS TO BE
Y I I I- III I I I �-. ADDED PER MFG, RECOM DS.
�/
e 1. SHRUB
2X DIA, ❑ I- 2 b 2. 2" (MIN) DEEP MULCH =
ROOT BALL I 3. PLANT TABLETS PER z z I
' SPECIFICATIONS � I
4. EARTH WATERING BASIN ~
BACKFILL MIX PER NOTES.
III -M (RAKE SMOOTH PRIOR a a (75% SAND, 25% SITE SOIL)
` a• TO PLANTING GROUND COVER) 0 C3
5. FINISH GRADE PQ P4 WATER BASIN LIP 4' MIN,
= a 3 REMOVE AFTER MAINTENANCE PERI❑D
- 6. ROOTBALL, SET CROWNw z
3 +/-
1"-2" ABOVE FINISH GRADE 6' DIA. GRAVEL SUMP, FILL W/ 3/4'
STAKING
7. COMPACT BACKFILL MIX - DIA, CRUSHED R❑CK, REFER T❑ SOILS
TER007FM11 DMN. (PER PLANTING NOTES) REPORT FOR DEPTH (OR PER 'PLANT
-2 8. BACK SIDE OF BASIN EQUAL PIT DRAINAGE DETAIL', CONSULT W/
TO SLOPE GRADE.6 12 L" -. _ LANDSCAPE ARCHITECT)
r ,
°'jj!,, PIT DRAIN (SEE DETAIL)
PLANT FERTILIZER TABLETS PER
1. TREE TRUNK a ¢
PLANTING NOTES � Pa -
2. ROOTBALL SET CROWN a NOTESi
FLUSH W/ FINISH GRADE I LANDSCAPE ARCHITECT TO INSPECT
- °" PALMS AT SITE PRIOR TO INSTALLATION,
STORM DRAIN/ 3, FINISH GRADE W ¢ °° NOTIFY AT LEAST 48 HOURS IN ADVANCE
UNDERGROUND UTILITIES -fry _ - 5 z 4. PLANT TABLETS PER cu ~a °v
SPECIFICATIONS �, 6, 6, PALM SHALL BE TRIMMED, CLEANED
a AND TIED AT ORIGINAL LgCATION
4SEE NOTE 3 5. TOP OF BARRIER MUST TRANSITIONAL ZONE OF COMPACTED ROOTBALL PRIOR TO TRANSPLANTING
BE AT GRADE. MEDIUM TEXTURE SOIL
6. COMPACT BACKFILL MIX (REFER TO 'PLANT PIT DRAINAGE DETAIL' ALL PALM TREE HEIGHTS SHALL BE DETERMINED
5 R R I fF OR MEASURED FROM THE TOP OF FIELD DUG
PER SPECIFICATIONS IF PROVIDED)
ROOT CROWN TO BASE OF FIRST FROND
'NOTES: ADJUST ROOTBALL CROWN HEIGHT TO ALLOW
-I..L.. FOR SETTLING,
STAKING
Z SIDEWALK UTILITY REFER TO NOTDETAIL
SHOWN.
J j POLE ROOT BARRIERS ARE TO BE INSTALLED IN
�I -0-I I REE LOCATED UNDER THE FOLLOWING
I-
i 1.ALL TURF AREAS
CURB AND GUTTER METER 2.STREET MEDIANS
3.TREES LOCATED CLOSER THAN
\ 5'-0" TO HARDSCAPES
TYP, --.- TYP, PALM PLANTING
I 1. TREE (PER PLAN)
2. TREE TIES
2 BETWEEN STAKE & TREE
3. 2" DIA X 10' LONG
UNDERGROUND STRUCTURE a LODGE POLE STAKES SIDEWALK (WHERE OCCURS)
CATCH BASIN ;2 7 4. PLANT TABLETS PER
TRASFORMER VAULT, a PLANTING NOTES TREE OR PALM TRUNK
-
SIDEWALKi z 5 5. EARTH WATERING BASIN ❑OTBALL
DRIVE I S. L. ,day p� �I .k- 6 IN GROUNDCOVER AREAS
' APPROACH �9 l I = 24• 6. FINISH GRADE
IPE CAP
U
7. ROOTBALL, SET CROWN
CURB AND GUTTER,""+/- 1"-2" ABOVE FINISHr-F'IN. GR. TREE OR PALM TRUNK
�
5' S' 10' � 10� GRADE I
8. COMPACT BACKFILL MIX
MIN MIN MIN MIN ROOTa4U DlA 8.•:
5, PER SPECIFICATIONS OOTBALL
MIN -
- 3' DIA. PIPE SWEEP ^tee
1 • TREE (PER PLAN)UP&
JOS
NOTES 2 TWIST TREE TIE TWICE LANTER BACKFILL MIX 3' DIA, PIPE SWEEP
1, TREE SPACING SHALL CONFORM TO PLANS APPROVED BY BETWEEN STAKE &TREE W/ PIPE CAP
THE CITY ENGINEER 3. 2" DIA x 6' LONG pOOOeOo*..............000��aae - , = 2781
LODGE POLE STAKES COMPACTED SOIL i I
ooeooeooaoaoes0000eooa000�ooe•o•,;
2. ALL TREES IN THE R, O, W, ARE SUBJECT TO LINE. OF, SIGHT e _ BACKFILL IMITS OF PLANT PIT'`
4. PLANT TABLETS PER �-
oa
CRITERIA AS APPROVED BY TRAFFIC ENGINEER, SPECIFICATIONS - - : ` ; � Siboatum
3. AT ALL LOCAL RES I DENT I MIEERSECT I ONS THE FIRST TWO - s 5• EARTH WATERING BASIN I ry k � ° Daw
23�
IN GROUNDCOVER AREAS ��"'^�tirn:CI''�
PARKWAY TREES AT ALL APPROACHES TO BE PLACED BEHIND SIDEWALK, b 3 DIA, CORRUGATED A. D. S. PERFORATED ,
6. FINISH GRADE DRAIN PIPE W/ DRAIN SOCK LAID @ -_
4, MAINTAIN 10 FEET FROM CENTER OF STREET TO EDGE
BASE OF ROOTBALL
7. ROOTBALL, SET CROWN
OF ALL UNDERGROUND FACILITIES, u FLUSH W/FINISH GRADE
4, MAINTAIN 10 FEET FROM ALL STREET LIGHTS, UTILITIES 2x 8. COMPACT BACKFILL MIX SECT I ❑N PLAN VIEW CITY OF FONTANA
STRUCTURES AND VALVE BOXES, Rooani DI e PER SPECIFICATIONS
DRAWN BY: SOV li:
DESIGNED BY: DATE:
TREE PLACEMENT PLANTING DETAILS PIT DRAIN CHBCKEDBY: APPROY6DBY: I / � DW(i�NjO.
CTh a/ENGAIE,�i/ERRCB. 25126F]iP.DATE 11/3U9 �✓� i
S I T IE S C A P e S
Landscape Architecture
and Planning
19762 MacArthur Blvd., Ste. 130
Irvine, CA. 92612
Richard Polhamus. License CA -#2782
(949) 644-9370 (949) 476-1432 FAX
DVM CHK
DATE 03/23/00
JOB* 99036
•
N
�-.i
00
l'
,
.•--I
EE
Q
O
00
rl
�
z
O
�
DVM CHK
DATE 03/23/00
JOB* 99036