Loading...
HomeMy WebLinkAbout3301-89 BOX TO BE PLACED AT RIGHT ANGLE TO HARDSCAPE EDGE w/ VALVE # ETCHED IN U 12"X18' PLASTIC BOX AND COVER WITH LOCK TOP CURL TYPE EXPANSION LOOP (MIN.24-) GEAR DRIVEN WATERPROOF WIRE CONNECTION 12*OR SHRUB ROTOR CHRISTYS LD TAG (STANDARD) AS NOTED HARDSCAPE SECURE TO SOLENOID PIGTAIL VALVE BOX W1 LOCK 12// M I N PVC RISER FINISH GRADE 3/4' • • FINISHED GRADE FINISH GRADE F FINISH GRADE GATE VALVE 12"MAT TO 0 ID Go MIN. FROM HARDSCAPES OF VALVE PVC LINE PIPE PVC MALE' ADAPTOR HEAVY DUTY GALV, NON—PRESSURE STEEL PUNCH LOCK 18" MIN LINE FITTING 12' M IN i UNION CONNECTION FASTENER C REQ' D). 1*021017-11X0. PEA GRAVEL (MIN.3 CU. Fr.) PVC LINE PIPE PVC SCH. 40 MALE ADAPTOR 1 CU. FT. PEA GRAVEL NON—PRESSURE LATERAL LINE PVC ELBOW (IYP. 2 PLACES) _ �I � �PVC LINE PIPE LATERAL LINE COMMON WIRE PVC SUPPLY LINE FITTINGS(SMS) MAINLINE CO oj L LATERAL LINE WITH PVC CONTROL WIRE Aee_ PRESSURE SUPPLY LINE TEE OR ELL CONTROL WIRES PVC STREET ELL CLEAN BACKFILL SCH. 80 NIPPLE �T�i :::.; ::..._ :::: ,•.::_ ly X 1" X30" G A L V. NOTES: 2" X 4" RWD. BLOCK Z-j�---ANGLE IRON 1. VALVES ARE TO BE INSTALLED IN SHRUB AREAS UNLESS OTHERWISE NOTED 2. WHEN MORE THAN ONE VALVE IS LOCATED IN THE SAME AREA. PROVIDE A SPACE A MIN. OF 3 FT. APART. 3. USE TEFLON TAPE ON ALL THREADED FITTINGS. 4. ONE VALVE PER VALVE BOX Ir Ir 6' MIN, ISVIP. GATE VALVE ""YP. BRAS"'O"% " OTE CONTROL VALSHRUB ROTORKbm OF 14 FINE GRANULAR MATERIAL WILL BE PLACED ON ALL LINES, NO WHITE WIRES LARGER THAN 1/2' IN SIZE. THIS WILL BE PERMITTED IN THE POP—UP SHRUB HEAD WALK OR CURB 10' VALVE BOX MARKED W/ 2' QUICK COUPLER VALVE (COMMON) INITIAL BACKFILL MEASURED FROM THE TOP OF PIPE, THE REMAINDER OF TRENCH CAN BE FILLED WITH ROCK SCREENED 2' MINUS. — 1/2' LETTERS READING . Q. C. 12' MIN, FROM HARDSCAPE MATERIALS FINISH GRADEBLUE FINISH GRADE . WATERPROOF ALL ALL BACK FILL IS TO BE SATURATED AND COMPACTED TO 90%. WIRE CONNECTIONS 4 �l gi INSTALL ALL PVC PIPE WITH LABEL UP. A Ai SNAKE ALL PIPES IN TRENCH, EVf N 6' MIN PEA GRAVEL RED BUNDLE AND TAPE ALL CONTROL WIRES AT 10' O.C. TO PRESSURE x 4 RWD OR BRICK BLACK MASTER CONTROL SUPPLY LINE AND PROVIDE A SERVICE LOOP AT ALL 90 dEGREE BRASS STREET ELL TYP VALVE CHANGES IN DIRECTION, RASS N I PPLE 6' MIN PRESSURE MAIN LARGER THAN 2' SHALL BE P.V.C. CLASS 315 SCH 80 PVC NIPPLE E__ FLOW SENSOR SMALLER THAN 2' SHALL BE P.V.C. SCHEDULE 40, THREADED BOTH ENDS PVC SHC 40 TEE OR ELL DIAMETER SAME SIZE CONTRACTOR SHALL PROVIDE SLEEVES OR CONDUIT LINES WHEN PVC STREET ELLS LATERAL LINE SIZE TO BE NOTED ON PLAN AS FLOW METER SIZE MAINLINE INSTALLATION IS UNDER ASPHALT OR CONCRETE. 24' MIN. #4 REBAR, ATTACH CONTRACTOR SHALL PROVIDE 24' OF COVER OVER PIPE W/(2) STAINLESS STEEL BANDS MINIMUM DISTANCE DOWNSTREAM SERVING A DRINKING FOUNTAIN OR PRESSURE MAINLINE 5X DIAMETER OF FLOW METER SIZE 3' AND LARGER. NOTE, M �IN I M U M DISTANCE UPSTREAM NOTE:USE TEFLON TAPE ON ALL THREADED FITTINGS 1OX DIAMETER OF FLOW 0 INSTALL 12# SHRUB -•P -QP -LP- HEAD 1 1/2 METER SIZE ABOVE F, 0, 0 F. G. -1 1/2# BELOW WALK OR CURB TRENCHING DETAIL LAV;N/4116"8" SHRUB POP-UP HEAD QUICK COUPLER. FLOW METER/MASTER VALV -In Ed. WALK OR CURB CLEAN BACK FILL SATURATE AND COMPACT TO 9M. HARDSCAPING FINISH GRADE II CONC. WALK NATIVE BACKFILL 2' MINUS 4# MAX 6 OR CURB FINISH GRADE NON PRESSURE LATERAL LINE W/SLEEVE --TTIT 1-1 1 1— A A d k z CU PRESSURE SUPPLY LINE W/SLEEVE IIIET I IEE =i • CONTROL WIRE SLEEVE Ti —111. 1 1=1 I I=1 11=1 11-I 11-1 I I_—I 11-I 11=1 I I—=,, I I 1�,, It zo . .x SAND BACK FILL HI POP SHRUB HEAD PRESSURE REGULATOR I R. SET MARLEX STREET ELL ONREQUISITEEDDRAWINGAS SHOWN REDUCE PRESSURE MI SCH 80 PVC NIPPLE BACKFLOW PREVENT THREADED BOTH ENDS STRAINER #40 BRASS NIPPLE IN MESH MODEL (4 PLACES) INSTALL CONTROL WIRE SLEEVE ADJACENT TO THE PRESSURE SUPPLY LINE, SIZE PER PVC LATERAL LINE BRASS ELBOW ­\ BRASS ELBOW SPEC. PVC STREET ELL o, --BRASS UNION ALL SLEEVES TO BE SCH. 40 PVC AND TO BE 2X THE DIAMETER OF THE LINE TO BE RELIEF PORT BRASS PIPE SLEEVED.LATERAL LINE WITH BRASS BALLLOOSE % , BRASS BALL ­ "�l INCREASE THIS DISTANCE TO 36' WHEN SLEEVING UNDER ROADWAYS AND COMMERCIAL PVC TEE OR ELL VALVE E RKEY\ 18' VALVE TRAFFIC WAYS. SLEEVES SHALL BE EXTENDED BEYOND HARDSCAPE TO POINTS AS REQUESTED BY DOUBLE SWING JOINT BRASS PIPE LOCK BOX INSPECTOR 2 EA. PVC STEET ELLS0 #4 AR IF SLEEVES ARE TO BE USED AT A LATER DATE, CONTRACTOR SHALL TAPE ENDS AND NOTE: BI- tx PROVIDE A VERTICAL MARK AT ENDS OF SLEEVING VISIBLE ON GROUND LEVEL.4— 0 ALL BUBBLERS TO BE INSTALLED NOTEi Ul • WITH TRIPLE SWING JOINTS INSTALL HI—POP IRR, HEAD 1 1/2' ABOVE F. G. "7 T�lT_`"6 0 F. G. 1 1/2'y BELOW WALK OR CURB F. G. 1 1/2' BELOW HARDSCAPE PRESSURE CONC. STABILIZE PRESSURE SUPPLY LINE (TRUST BLOCK) FRONT SUPPLY LINE (INTAKE) C D I SCHARGE) BACKFLOW ENCLOSURE — 3/4' GRAVEL (SEE NOTE BELOW) BRASS ELBOW .- SLEEVING DETAIL BUBBLER HEAD HI -POP SHRUB tiE,,,An 6-1 .—BRASS UNION BUILDING EDGE f BRASS BALL FINISH GRADE VALVE TI IT Fl �'l 1-1 Ito I LATERAL 120 VOLT CONTROL WIRING 6 MIN D WIRING #4 REBAR MAIN OR LATERAL LINE MAIN Y, LATERAL MAIN SUPPLY RISER 6219 LATERAL 1 PLAN ' Ir i*A e4ir A TEE OR ELL NOTE, B CKFLOW ENCLOSURE, LE MEUR SHRUB SPRAY HEAD OR EQUAL 24'X60'X36' HIGH MAINLINE ELEVATION 12' NIPPLE HINGED AT ONE END SECURE TO SCH 80 PVC NIPPLE 6'XB' FOOTING W/4' J DOLTS END ELEVATION VIEW THREADED BOTH ENDS (EQUIPMENT TO BE CENTERED oor� INSIDE HOUSING) 12 TEE OR ELL FINISH GRADE MAIN OR LATERAL LINE ALL MAINNE LISHALL !E INHALE ALL 120 MARLEX STREET ELL(PRIVATE) GENERAL NOTES, INSTALLED PER MFG'S VOLT WIRE IN 1. CONTRACTOR SHALL FORM ENCLOSURE AND REQWUESTV 'E':CTOR- SPECIFICATIONS CONDUIT PER LUCAL PVC STREET ELL(PUBLIC)III CODE 'ek 7 PROVIDE A MY UIP Or WIRE PRIOR TO POURING ENCLOSURE 114 ALL CHANGES DF DIRECTION 12' N I PPLE SNAKE ALL PLASTIC GREATER THAN 30 DE ES REHM PIPE 114M TRENCHES TIES AFTER ALL COW4ETIONS PVC STREET ELL AS SHOWN HAVE BEEN MADE o PLAN MARLEX STREET ELL(PRIVATE) 2. CONTRACTOR slDL71L IJSVseo cI T 0 CONCRETE j 101 M r- 14AXIWN TO MAINLAINE. PVC STREET ELL(PUBLIC) MARLEX STREET ELL Z.riw... MJNIILE WIRING AT PLAN VIEW SCHEDULE 40 STREET ELL SCHEDULE 80 PVC RISER PVC LAT. LINE NOTE, DO NOT INSTALL 120 VOLTAGE OR HIGHER WIRE IN THE SAME TRENCH AS THE IRRIGATION CONTROL WIRING NOTE, ALL PIPE AND FITTINGS SHALL BE SCHEDULE CITY OF FONTANA NOTE, FIXED RAISERS ALLOWED ONLY AGAINST BUILDINGS 80 PVC UNLESS OTHERWISE SPECIFIED WALLS, FENCES, ETC. USE PVC STREET ELLS W/TEFLON TAPE FOR ALL DRAWN PUBLIC JOBS scmm BAcrw*.-urLO Wvr =lam" PICUVENTEX�� X, S��A-YPIPING AND WIRING SWING JOINT SHRUB HEAD m Nm Cm Dwm MP. r_ c. eneb•El", LATE larwI3 3 pa zi ®I u0 � >- 00 t-- O ;5 4.04 U 0 00 rYl z 0 *-4 Z ®I