SCALE 1:500
ALL DIMENSIONS ARE IN METERS UNLESS OTHERWISE SHOWN
NOTE: THIS PLAN ACCURATE FOR ELECTRICAL WORK ONLY
SEE SHEET 3 FOR LEGEND
FOR REDUCED PLANS ORIGINAL 0 20 40 60 80
SCALE IS IN MILLIMETERS I I I I I 1 1
W
z
H
U
Q
USERNAME=>$USER
DGN FILE => $REQUEST
tris
CONSTRUCTION NOTES
DIST COUNTY ROUTE KILOMETER POST SHEET TOTAL
TOTAL PROJECT No SHEETS
08 SBd 10 16.22 8 43
Q GESS/0"v
REGISTERED CIVIL ENGII`JEER
Oo,�-� E CgR�S Fyc�
C-)o� ,
08/09/02
w�,,
P S APPRhV,,AL DATENo. C57886
y_ * Exp. 06/30/06
�l CIVIL p�
City of Fontana F OF rNv\
SPONSORING AGENCY
Meyer, Mohaddes Associates, h7c.
An /teris Company
1515 S. MANCHESTER AVE.
ANAHEIM, CA 92802
The State of California or its officers or agents shall not be responsible
for the accuracy or completeness of electronic copies of this plan sheet.
(THIS SHEET ONLY)
1❑ FURNISH AND INSTALL SIX (6) 1 %2" (38 mm) HIGH DENSITY POLYETHYLENE (HDPE)
CONDUITS BY DIRECTIONAL DRILL UNDER PAVEMENT OR SIDEWALK, OR BY TRENCH
IN SOIL. SEE SHEET 33, DETAIL A UNLESS OTHERWISE SPECIFIED.
FURNISH AND INSTALL LOCKING SPLICE VAULT (P48) WITH SPLIT LID. SPLICE VAULT
COVER TO BE INSCRIBED "TRAFFIC". SEE SPLICE VAULT DETAIL ON SHEET 32.
[-3]FURNISH AND INSTALL ONE (1) 96—STRAND SMFO CABLE IN ONE (1) OF THE HDPE
CONDUITS. WHERE CABLE PASSES THROUGH SPLICE VAULT, COIL 50 FEET (15 m)
OF 96 SMFO CABLE IN EACH VAULT. SEE SPECIAL PROVISIONS FOR DETAILS.
�4 FURNISH AND INSTALL 12—STRAND SMFO CABLE IN EXISTING COMMUNICATION
CONDUIT.
❑5
FURNISH
AND INSTALL ONE
(1) 2"
(51 mm) HDPE CONDUIT. FURNISH AND
INSTALL
12—STRAND SMFO
CABLE
IN NEW CONDUIT. SEE SHEET 33, DETAIL B.
[jj FURNISH AND INSTALL NEW PATCH PANEL IN EXISTING CALTRANS CABINET.
TERMINATE ALL STRANDS FROM EACH 12—SMFO CABLE ON PANEL AND COMPLETE
CROSS CONNECTS PER FIBER ASSIGNMENT TABLE ON SHEET 38.
21 COIL MINIMUM OF 16—FEET (4.9 m) OF 12—STRAND SMFO CABLE IN EXISTING PULL
BOX.
FUSION SPLICE FOUR (4) STRANDS OF 96—STRAND SMFO CABLE TO THE
APPROPRIATE STRANDS OF 12—STRAND SMFO CABLE USING SPLICE ENCLOSURE
PER FIBER ASSIGNMENT TABLE ON SHEET 38. COIL MINIMUM OF 16—FEET (4.9 m)
OF 12—STRAND SMFO CABLE FOR SLACK IN SPLICE VAULT.
33 FURNISH AND INSTALL TWO (2) 4" (102 mm) GRS CONDUIT BY TRENCH IN
PAVEMENT UP TO BRIDGE ABUTMENT. SEE SHEET 33, DETAIL D. INSTALL GRS
CONDUIT THROUGH BRIDGE ACCESS HOLE AND ATTACH GRS CONDUIT TO BOTTOM
OF BRIDGE USING GALVANIZED HANGERS SPACED AT 8—FOOT INCREMENTS. SEE
SHEET 33, DETAIL E.
34 FURNISH AND INSTALL THREE (3) 1%2" (38 mm) HDPE CONDUITS IN EACH 4" (102
mm) CONDUIT.
F4]8 FURNISH AND INSTALL TWO (2) 4" PVC CONDUITS BY TRENCH METHOD IN
PAVEMENT UP TO BRIDGE ABUTMENT. SEE SHEET 33, DETAIL D. CONTRACTOR
SHALL POT HOLE PAVEMENT TO LOCATE UTILITY DUCT. INSTALL CONDUIT IN
EXISTING UTILITY DUCT IN BRIDGE. SEE SHEET 35, DETAIL A.
F9] FURNISH AND INSTALL PVC/STEEL CONDUIT ADAPTER. SEE SHEET 35, DETAIL B.
50 COIL AN ADDITIONAL 100—FEET (30.5 m) OF 96—SMFO CABLE.