HomeMy WebLinkAbout3258-34I 5'-6" (MIN) I 6-1 1/2" HDPE COf DETAIL C METROLINK ROW SPLICE VAULT 6-1 1/2" HDPE CONDUITS SPLICE V 6-1 1/2 to HDPE CONDUITS 10" STEEL CASING (0.251 INCHES THICK MINIMUM) DIRECTIONAL DRILL STEEL CASING 30" R=4'f J EXISTING ROADWAY An" to 5'-6 SEE DETAIL C —/ 60'± �Z Q 0 Q o' U w RAILROAD TRACK i 10" STEEL RIGID METALLIC CONDUIT CASING DETAIL A METROLINK CROSSING DETAIL NO SCALE SANBAG ROW 10" STEEL RIGID METALLIC CONDUIT CASING 565'± 8=150'± SEE DETAIL C EXISTING ROADWAY 5'-6" 110'± METROLINK ROW 30 /—SPLICE VAULT \\— R=4'± � 22't � SANBAG ROW FUTURE LRT CROSSING 66" DETAIL B SANBAG CROSSING DETAIL NO SCALE 55'± 6-1 1/2 it HDPE CONDUITS R=150'+ 30" SPLICE VAULT 6-1 1/2 so HDPE CONDUITS GENERAL NOTES (THIS SHEET ONLY) 1. CONTRACTOR SHALL COORDINATE ALL WORK DONE ON METROLINK AND SANBAG ROW WITH METROLINK/SCRRA, THE LACMTA, AND SANBAG. CONTRACTOR SHALL NOTIFY SAID AGENCIES 5 DAYS IN ADVANCE OF ANY WORK FOR APPROVAL. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ENCROACHMENT PERMITS FOR WORK ON SCRRA AND SANBAG ROW. CONTRACTOR SHALL SUBMIT TRAFFIC CONTROL PLANS TO SCRRA, LACMTA, AND SANBAG WITH ENCROACHMENT PERMITS. 3. SEAL STEEL CASING ABUTMENTS WITH MORTAR, AFTER TIGHTLY WRAPPING CONDUITS WITH 2 LAYERS OF #15 BUILDING PAPER. 4. STEEL CASING JOINTS SHALL BE WELDED.