HomeMy WebLinkAbout3258-3GENERAL NOTES (FOR SHEETS 4 THROUGH 21 ONLY)
1 •
SEE SPECIAL PROVISION FOR SPECIFICATIONS ON FIBER OPTIC
CABLE,
CCTV, AND DATA/VIDEO
LEGEND.
TRANSMISSION EQUIPMENT.
ANAHEIM, CA 92802-2907
DRAWN BY:
2.
THE CONTRACTOR SHALL REPAIR ALL DAMAGED LANDSCAPING
AND IRRIGATION TO THE SATISFACTION
OF THE ENGINEER.
AT THE END OF EACH WORK DAY, CONDUIT CAPS SHALL BE PLACED ON ALL VACANT DUCTS. DUCTS
Date : 5/1 /03
3.
CONDUIT SHALL NOT BE INSTALLED WITHIN ONE FOOT EITHER SIDE OF
WHEEL TRACKS (PARALLEL TO
WHEEL TRACKS). CROSSINGS ARE ALLOWED.
4•
CONDUIT SHALL NOT BE INSTALLED DIRECTLY OVER ANY UTILITY
LINE
(PARALLEL WITH THE LINE).
0
UTILITY LINE CROSSINGS ARE ALLOWED.
E�l6E PULL BOX #3.5, #5,
#6, #6E
5.
LOCATIONS OF CONDUIT SHOWN ON PLANS ARE SCHEMATIC IN
NATURE. FINAL LOCATION OF CONDUITS
OSV
SHALL BE DETERMINED AS DIRECTED BY THE ENGINEER IN THE
FIELD.
6. PULL BOXES AND SPLICE VAULTS SHALL NOT BE LOCATED IN DRIVEWAYS OR OTHER LOCATIONS
WHICH MAY INTERFERE WITH THE MOVEMENT OF PEOPLE OR VEHICLES. PULL BOX LOCATIONS SHALL
BE ADJUSTED AS NEEDED.
7. PULL BOXES AND SPLICE VAULTS SHALL BE INSTALLED IN ACCORDANCE WITH THE DETAILS ON SHEET
31, AND INSCRIBED "TRAFFIC".
8. WHERE CONDUIT IS INSTALLED AND DISTURBS EXISTING STRIPING, CONTRACTOR SHALL ARRANGE AND
PAY FOR STRIPING. SEE SPECIAL PROVISIONS FOR CONTRACTOR RESPONSIBILITY FOR TEMPORARY
PAVEMENT MARKINGS.
9. ALL PCC SIDEWALK, DAMAGED BY THE CONTRACTORS OPERATIONS, SHALL BE SAWCUT, REMOVED AND
REPLACED, TO EXISTING EXPANSION/SCRIBE JOINTS.
10. THE CONTRACTOR SHALL HAND DIG AND EXPOSE ALL UTILITY CROSSINGS PRIOR TO ANY OPEN
TRENCHING OPERATIONS. THE CONTRACTOR SHALL USE EXTREME CARE WHEN EXPOSING EXISTING
UTILITIES.
11. EXISTING UNDERGROUND UTILITIES SHOWN ARE TAKEN FROM RECORD INFORMATION TO AID THE
CONTRACTOR. CONTRACTOR SHALL VERIFY LOCATION (BOTH VERTICAL AND HORIZONTAL) OF ALL
EXISTING UNDERGROUND LINES (SHOWN OR NOT) AND NOTIFY ENGINEER OF ANY DISCREPANCIES OR
CONFLICTS PRIOR TO DOING STREET WORK.
12. THE CONTRACTOR SHALL LOCATE, PROTECT, SHORE, BRACE, SUPPORT, AND MAINTAIN ALL EXISTING
FACILITIES INCLUDING GAS, WATER, IRRIGATION, SEWER, POWER, STREET LIGHTS, TELEPHONE AND
OTHER CONSTRUCTION WHICH MAY BE UNCOVERED OR OTHERWISE AFFECTED BY THE WORK.
CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND PRESERVATION OF ALL SUCH
FACILITIES IN THE AREA OF CONSTRUCTION, AND SHALL NOTIFY UTILITIES FORTY-EIGHT HOURS IN
ADVANCE OF ANY CONSTRUCTION.
USA (UNDERGROUND SERVICE ALERT) SHALL BE CALLED AT 800-227-2600 BEFORE PLANTING TREES,
TRENCHING, DIGGING POST HOLES, BLASTING, GRADING, EXCAVATING, DRILLING, BORING, ETC.
13. ALL TRAFFIC CONTROL DEVICES SHALL BE IN PLACE BEFORE WORK IS STARTED. DEVICES NO LONGER
REQUIRED SHALL BE REMOVED AS SOON AS POSSIBLE. CONTRACTOR SHALL PROVIDE TRAFFIC
CONTROL PLANS TO ENGINEER FOR APPROVAL PRIOR TO CONSTRUCTION. TRAFFIC CONTROL PLANS
SHALL CONFORM TO WATCH MANUAL.
14. PEDESTRIAN TRAFFIC MUST BE MAINTAINED AT ALL TIMES. PEDESTRIANS MAY BE RELOCATED ONTO
PRIVATE PROPERTY WITH OWNERS PERMISSION ONLY.
15. NO EQUIPMENT OR MATERIALS SHALL BE STORED ON SIDEWALK AT ANY TIME.
16. A 12" (305 mm) VERTICAL SEPARATION BETWEEN NEW CONDUITS AND OTHER UTILITIES SHALL BE
MAINTAINED AT CROSSINGS. A 3' (914 mm) MIN. HORIZONTAL SEPARATION BETWEEN NEW CONDUITS
AND POWER AND WATER UTILITIES THAT RUN PARALLEL SHALL BE MAINTAINED. A 3' (914 mm)
(EXCEPT WHERE NOTED) MINIMUM SEPARATION BETWEEN CONDUIT AND SANITARY SEWER AND STORM
DRAINS THAT RUN PARALLEL SHALL BE MAINTAINED, UNLESS OTHERWISE APPROVED BY THE COUNTY.
THE CONTRACTOR SHALL MAINTAIN A MINIMUM 3' (914 mm) CLEARANCE FOR ALL OTHER FACILITIES.
A R
DIAL TWO WORKING
BEFORE DAYS BEFORE
YOU DIG You DIG
Toil. FREE 1-800-227-2600 REV.
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
REVISION DESCRIPTION DATE ENGR. CITY DATE STANDARDS IN EFFECT.
Q�pf ESS/0\
W ` Z r
No. C57886
Exp. 06/30/02
OF c hl-
GRS GALVANIZED RIGID STEEL
ROW RIGHT-OF-WAY
SCRRA SOUTHERN CALIFORNIA REGIONAL RAIL ASSOCIATION
LACM TA LOS ANGELES COUNTY METROPOLITAN
TRANSPORTATION AUTHORITY
SANBAG SAN BERNADINO COUNTY AREA
GOVERNMENTS
Mkyw, M4>�haafra�s wssocb* bt
M Maris Company
LEGEND.
ANAHEIM, CA 92802-2907
DRAWN BY:
(714) 780-7243
EXISTING
DESIGNED BY:
17.
AT THE END OF EACH WORK DAY, CONDUIT CAPS SHALL BE PLACED ON ALL VACANT DUCTS. DUCTS
Date : 5/1 /03
CHECKED 8'f5
SCOTT CARLSON
IN BUILDING ENTRANCES, NEW OR EXISTING SHALL BE SEALED PRIOR AND AFTER PLACEMENT OF
FIBER OPTIC CABLE, INCLUDING DUCTS ON WALLS WHERE CORING IS REQUIRED.
0
El E:l6
E�l6E PULL BOX #3.5, #5,
#6, #6E
18.
THE REMOVAL, STORAGE AND REPLACEMENT OF ALL SHRUBBERY SHALL BE THE RESPONSIBILITY OF
OSV
SPLICE VAULT
THE CONTRACTOR. ALL LANDSCAPING SHALL BE RESTORED TO ORIGINAL OR BETTER CONDITION.
8
VAULT
19.
ALL BORINGS SHALL BE OUTSIDE THE DRIP LINE OF ALL TREES TO PREVENT ROOT DAMAGE.
FIRE HYDRANT
20.
CAUTION! BURIED TRAFFIC SIGNAL LOOPS, DAMAGED OR CUT, SHALL BE REPLACED BY CONTRACTOR
TO CALTRANS SPECIFICATIONS. NOTIFY CITY INSPECTOR IMMEDIATELY AND TRAFFIC DEPARTMENT 24
CONTROLLER CABINET
HOURS PRIOR TO ANY WORK IN THESE AREAS.
�
SERVICE CABINET
21.
CONTRACTOR SHALL MAINTAIN BIKE PATH OPEN FOR USE DURING. CONSTRUCTION. CROSSING ON THE
BIKE PATH SHALL BE MADE BY USING JACK AND BORE OR BY NIGHT WORK. ALL TRENCHING SHALL
DRIVEWAY
BE RESTORED BEFORE DAYLIGHT USE. TRAFFIC CONTROL SIGNAGE SHALL BE USED TO WARN TRAFFIC
OF THE CONSTRUCTION OPERATIONS.
MH
MANHOLE
22.
TRAFFIC SIGNAL CIRCUITS AND INTERCONNECT CONDUITS MAY NOT BE SHOWN. CONTRACTOR SHALL
0
CATCH BASIN
LOCATE ALL TRAFFIC SIGNAL CIRCUITS AND INTERCONNECT CONDUITS PRIOR TO ANY TRENCHING OR
BORING. PROVIDE 3' (914 mm) SEPARATION BETWEEN NEW CONDUITS AND ALL TRAFFIC SIGNAL AND
E
ELECTRIC LINE
INTERCONNECT CONDUITS AND 3' (914 mm) FROM ALL TRAFFIC SIGNAL CONTROLLERS AND PULL
BOXES. ALL TRAFFIC SIGNAL AND INTERCONNECT CONDUITS SHALL BE MAINTAINED AND PROTECTED.
GAS LINE
23.
UNLESS OTHERWISE NOTED, ALL CONDUITS CROSSING SIGNALIZED INTERSECTIONS, CALTRANS, SANBAG,
w
WATER LINE
METROLINK/SORRA R/W, OR LATERALLY CROSSING SIERRA AVENUE SHALL BE BORED BETWEEN SPLICE
VAULTS.
T
TELEPHONE LINE
24.
ALL NEW CONDUITS SHALL CONTAIN ONE (1) #10 GREEN STRANDED FOR FUTURE USE AS PULL
0I
CCTV CAMERA
WIRE.
25.
THE CONTRACTOR SHALL FURNISH AND INSTALL COLOR CODED CONDUITS WHERE SPECIFIED ON
PROPOSED
PLANS. THE CONDUITS SHALL BE COLOR CODED ORANGE, YELLOW, RED, BLACK, BLUE, AND
a5
PULL BOX #5
GREEN.
26.
THE CONTRACTOR SHALL PROVIDE ALL NECESSARY PATCH CORDS WITH APPLICABLE CONNECTORS (ST,
06E
PULL BOX #6 WITH
EXTENSION
PC, PC) AT BOTH ENDS.
F__lSV
SPICE VAULT (P48)
27.
THE CONTRACTOR SHALL FIELD VERIFY ELECTRICAL SERVICE LOCATIONS AND PROVIDE ALL NECESSARY
ACCESSORIES FOR INSTALLING BACKBONE FIBER, COMMUNICATION EQUIPMENT AND CCTV SYSTEM.
SERVICE CABINET
28.
THE CONTRACTOR SHALL COORDINATE TRUNK LINE CONSTRUCTION WITH CCTV SYSTEM.
96 -STRAND SINGLE
MODE FIBER OPTIC CABLE
29.
THE CONTRACTOR SHALL BE RESPOSIBLE FOR MAINTAINING RECORD DRAWINGS FOR ALL WORK
THROUGHOUT THE COURSE OF CONSTRUCTION.
12 -STRAND SINGLE
MODE FIBER OPTIC CABLE
30.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING SURVEY
CCTV CAMERA
MONUMENTS OR MARKERS DURING CONSTRUCTION.
31.
IF UNUSUAL AMOUNTS OF BONE, STONE OR ARTIFACTS ARE UNCOVERED, WORK WITHIN 165 -FT OF
THE AREA SHALL CEASE IMMEDIATELY AND A QUALIFIED ARCHAEOLOGIST SHALL BE CONSULTED TO
DEVELOP, IF NECESSARY, MITIGATION MEASURES TO REDUCE ANY ARCHAEOLOGICAL IMPACT TO A
LIST OF ABBREVIATIONS
LESS THAN SIGNIFICANT EFFECT BEFORE CONSTRUCTION RESUMES IN THE AREA. SEE SPECIAL
PROVISIONS.
32.
COST TO REMOVE AND REPLACE EXISTING PAVEMENT OVER UTILITY LINE TRENCHES SHALL BE
HDPE
HIGH
DENSITY POLYETHYLENE
INCLUDED IN THE BID PRICE. TRENCHES SHALL BE BACKFILLED AND PAVEMENT SHALL BE REPLACED
MH
MAINTENANCE HOLE
PER CITY DETAIL CE12. PAVEMENT SHALL BE REPLACED IN KIND (MINIMUM OF 4" AC ON 12" AB) AS
DETERMINED IN THE FIELD BY THE ENGINEER. ALL STRIPING AND PAVEMENT MARKINGS SHALL BE
SMFO
SINGLE
MODE FIBER OPTIC
RESTORED (IN THERMOPLASTIC).
FDU
FIBER
DISTRIBUTION UNIT
33.
FOR WORK ON CALTRANS RIGHT-OF-WAY, CONTACT CALTRANS 10 -DAYS IN ADVANCE OF
WIC
WALL
INTERCONNECT CENTER
CONSTRUCTION AND/OR RAMP CLOSURES..
TWP
TWISTED
PAIR
PVC
POLYVINYL CHLORIDE
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
REVISION DESCRIPTION DATE ENGR. CITY DATE STANDARDS IN EFFECT.
Q�pf ESS/0\
W ` Z r
No. C57886
Exp. 06/30/02
OF c hl-
GRS GALVANIZED RIGID STEEL
ROW RIGHT-OF-WAY
SCRRA SOUTHERN CALIFORNIA REGIONAL RAIL ASSOCIATION
LACM TA LOS ANGELES COUNTY METROPOLITAN
TRANSPORTATION AUTHORITY
SANBAG SAN BERNADINO COUNTY AREA
GOVERNMENTS
Mkyw, M4>�haafra�s wssocb* bt
M Maris Company
1515 S. MANCHESTER AVE.
ANAHEIM, CA 92802-2907
DRAWN BY:
(714) 780-7243
DKP/PMF
DESIGNED BY:
�Q
SEC
Date : 5/1 /03
CHECKED 8'f5
SCOTT CARLSON
ANA0 C�AL�BI�OO G NSA
FIBER OPTIC DEPLOYMENT PLAN
Sierra Avenue ANO SCALE
NOTES ANDAEGEND DATE:
ENGINEER R.C.E. 511
08/02
DRAWING NO.: 3
s
3258 4