x 0 x x x CONSTRUCTION NOTES (THIS SHEET ONLY. F51 FURNISH AND INSTALL ONE (1) 2" (51 mm) HDPE CONDUIT. FURNIC w z w 0 z cn z Q w v 1— v w 0 U O Cn 0-1w CONDUCTOR TYPE FUNCTION INSTALL 12 -STRAND SMFO CABLE IN NEW CONDUIT. SEE SHEET 33, 2 F81 INSTALL CONDUIT INTO EXISTING PULL BOX. COIL MINIMUM OF 16 -FE OF 12 -STRAND SMFO CABLE FOR SLACK IN PULL BOX. 4 5 RG -59/U QUAD SHEILD COAX CCTV VIDEO Fl -01 FURNISH AND INSTALL WALL INTERCONNECT CENTER (WIC) IN EXISTIN CABINET WITH LINE CONDITIONER/SURGE SUPPRESSOR, IF REQUIRED 1 DIRECTED BY THE ENGINEER. INSTALL AND TERMINATE 12 -STRAND S CCTV DATA 1 USING WIC IN EXISTING CABINET. 1 12 F141 FUSION SPLICE SIX (6) STRANDS OF 96 -STRAND SMFO CABLE TO TI 2 APPROPRIATE STRANDS OF 12 -STRAND SMFO CABLE USING SPLICE I o PER FIBER ASSIGNMENT SCHEDULE ON SHEET 38. COIL MINIMUM OF (4.9 m) OF 12 -STRAND SMFO CABLE FOR SLACK IN SPLICE VAULT. m - COORDINATE SPLICING WITH CCTV DETAILS AND AS NOTED IN FIBER o w ASSIGNMENT TABLE ON SHEET 38. w - Cr w V2] EXISTING CALTRANS TYPE 332 CABINET. ALL EQUIPMENT AT THIS LO > SHALL BE RACK MOUNTED. CONTRACTOR SHALL COORDINATE INSTALI Lli rr o CALTRANS AND ENGINEER. F41] FURNISH AND INSTALL DOME CCTV CAMERA SYSTEM, ON EXISTING 1- \ \ Q coao SIGNAL POLE USING CCTV MOUNTING EQUIPMENT. SEE SPECIAL 0 0 0 PROVISIONS FOR DETAILS. FOR MOUNTING, USE MANUFACTURER'S E E w MOUNTING STANDARDS. 2'o F2] FURNSIH AND INSTALL FIBER OPTIC TRANSCEIVER (1) IN EXISTING o m m CABINET WITH LINE CONDITIONER/SURGE SUPPRESSOR (IF o REQUIRED). COMPLETE CONNECTION TO WIC. aw J z 0 w FURNISH AND INSTALL AND TERMINATE CCTV CAMERA DATA CABLE U - U AND COAX CABLE ON FIBER OPTIC TRANSCEIVER. 10 Q'�' w _ © FURNISH AND INSTALL 20 -AMP BREAKER IN EXISTING CABINET FOR U 0 CCTV CAMERA SERVICE. COMPLETE CONNECTIONS IN SERVICE CABINET AND TRAFFIC CABINET TO PROVIDE SERVICE FOR CCTV CAMERA. w z w 0 z cn z Q w v 1— v w 0 U O Cn 0-1w CONDUCTOR TYPE FUNCTION RUN 2 3 4 5 RG -59/U QUAD SHEILD COAX CCTV VIDEO 1 1 3PR 24AWG CONDUTOR CABLE CCTV DATA 1 1 12 CCN POWER 2 2 #12 CCTV SERVICE 2 12—SMFO DROP CABLE 1 1 CONDUIT SIZE E E E E 2'o NOTE: ALL CONDUITS AND CONDUCTORS ARE NEW UNLESS OTHERWISE SPECIFIED: (E) EXISTING GENERAL NOTE (THIS SHEET ONLY FOF 1. CONTRACTOR SHALL PROVIDE ALL NECESSARY PATCH CORDS WITH APPLIC) CONNECTORS (ST, FCPC) AT BOTH ENDS. 2. CONTRACTOR SHALL FIELD VERIFY ELECTRICAL SERVICE LOCATION AND PR( ALL NECESSARY ACCESSORIES FOR INSTALLING CCTV SERVICE. 3. CONTRACTOR SHALL COORDINATE WORK DONE ON CCTV LOCATION SHEETS WORK DONE ON COMMUNICATION SHEETS. 4. TO ATTACH CAMERA BRACKET TO POLE, CONTRACTOR SHALL UTILIZE STAID STEEL STRAP; AS DIRECTED BY ENGINEER. 5. CONTRACTOR SHALL COORDINATE ALL WORK AT THIS LOCATION WITH CALT AS DIRECTED BY ENGINEER. rl SCALE 1:250 Il I STI ni INTY Pni IT P7 KILOMETER 11 POST SHEET TOTAL 3 ALL DIMENSIONS ARE IN METERS UNLESS OTHERWISE SHOWN NOTE: THIS PLAN ACCURATE FOR ELECTRICAL WORK ONLY SEE SHEET T-2 FOR LEGEND FOR REDUCED PLANS ORIGINAL 0 20 40 60 80 USERNAME => $USER SCALE IS IN MILLIMETERS I I ( I I I I I I DGN F I LE => $REQUEST FOOTHILL BLVD CCTV DESIGN CALTRANS PERMIT NUMBER 08 -02 -N -UL -0897 29 SIERRA/FOOTHILL CCN CU 000000 � EA 08 924740 ble ,et. ILm cV 0 1-1 N O \O 006 0 00 WW I— L-- 0o J J LLJW Q:�i 01-