Loading...
HomeMy WebLinkAbout3258-28CONDUCTOR TYPE FUNCTION RUN t 2 3 4 RG -59/U QUAD SHEILD COAX CCTV VIDEO 1 1 3PR 24AWG CONDUTOR CABLE CCTV DATA 1 1 #12 CCTV POWER 2 2 #12 CCTV SERVICE 12-SMFO DROP CABLE 1 1 CONDUIT SIZE E E 2" E NOTE: ALL CONDUITS AND CONDUCTORS ARE NEW UNLESS OTHERWISE SPECIFIED: (E) EXISTING CONSTRUCTION NOTES (THIS SHEET ONLY. �5 FURNISH AND INSTALL ONE (1) 2" (51 mm) HDPE CONDUIT. FURNISH AND INSTALL 12 -STRAND SMFO CABLE IN NEW CONDUIT. SEE SHEET 33, DETAIL B. [7]REMOVE EXISTING PULL BOX. FURNISH AND INSTALL NEW PULL BOX NO. 6 WITH EXTENSION. COIL MINIMUM OF 16 -FEET (4.9 m) OF 12 -STRAND SMFO CABLE FOR SLACK IN PULL BOX. 10 FURNISH AND INSTALL WALL INTERCONNECT CENTER (WIC) IN EXISTING TRAFFIC CABINET WITH LINE CONDITIONER/SURGE SUPPRESSOR, IF REQUIRED AS DIRECTED BY THE ENGINEER. INSTALL AND TERMINATE 12—STRAND SMFO CABLE USING WIC IN EXISTING CABINET. 12 REMOVE DETECTOR INTERFACE PANEL IN EXISTING TRAFFIC CABINET TO ACCOMMODATE WIC AS DIRECTED BY ENGINEER. [1-4] FUSION SPLICE SIX (6) STRANDS OF 96—STRAND SMFO CABLE TO THE APPROPRIATE STRANDS OF 12 -STRAND SMFO CABLE USING SPLICE ENCLOSURE PER FIBER ASSIGNMENT SCHEDULE ON SHEET 38. COIL MINIMUM OF 16 -FEET (4.9 m) OF 12 -STRAND SMFO CABLE FOR SLACK IN SPLICE VAULT. COORDINATE SPLICING WITH CCTV DETAILS AND AS NOTED IN FIBER ASSIGNMENT TABLE ON SHEET 38. [f7] FURNISH AND INSTALL FIBER OPTIC MODEM TO SUPPORT TRAFFIC SIGNAL CONTROLLER. COMPLETE CONNECTION TO THE EXISTING TRAFFIC SIGNAL CONTROLLER AND WIC. [f8] FURNISH AND INSTALL FIBER MULTIPLEXER TO SUPPORT VIDEO DETECTION SYSTEM. COMPLETE CONNECTION TO THE VIDEO DETECTION UNIT AND WIC. R3 FURNISH AND INSTALL ONE (1) 2" (51 mm) HDPE CONDUIT. SEE SHEET 33, DETAIL B. 3� REMOVE EXISTING PULL BOX. FURNISH AND INSTALL NEW PULL BOX N0. 5. 41 FURNISH AND INSTALL DOME CCTV CAMERA SYSTEM, ON EXISTING SIGNAL POLE USING CCTV MOUNTING EQUIPMENT. SEE SPECIAL PROVISIONS FOR DETAILS. FOR MOUNTING, USE MANUFACTURER'S MOUNTING STANDARDS. fl2 FURNSIH AND INSTALL FIBER OPTIC TRANSCEIVER (1) IN EXISTING CABINET WITH LINE CONDITIONER/SURGE SUPPRESSOR (IF REQUIRED). COMPLETE CONNECTION TO WIC. FF� FURNISH AND INSTALL AND TERMINATE CCTV CAMERA DATA CABLE AND COAX CABLE ON FIBER OPTIC TRANSCEIVER. F4� FURNISH AND INSTALL NEW SERVICE CABINET PER CITY STANDARDS. FURNISH AND INSTALL NEW 20 -AMP BREAKER FOR CCTV CAMERA SERVICE AND 20 -AMP BREAKER FOR TRAFFIC SIGNAL CONTROLLER. CONTRACTOR TO COORDINATE WITH SCE FOR POWER TO NEW SERVICE CABINET. GENE THIS SHEET ONLY): 1. CONTRACTOR SHALL PROVIDE ALL NECESSARY PATCH CORDS WITH APPLICABLE CONNECTORS (ST, FCPC) AT BOTH ENDS. 2. CONTRACTOR SHALL FIELD VERIFY ELECTRICAL SERVICE LOCATION AND PROVIDE ALL NECESSARY ACCESSORIES FOR INSTALLING CCTV SERVICE. 3. CONTRACTOR SHALL COORDINATE WORK DONE ON CCTV LOCATION SHEETS WITH WORK DONE ON COMMUNICATION SHEETS. 4. TO ATTACH CAMERA BRACKET TO POLE, CONTRACTOR SHALL UTILIZE STAINLESS STEEL STRAP; AS DIRECTED BY ENGINEER. 1 1 /2 0 1 2 3 inches on original drawing SCALE:1 "= 20'