Loading...
HomeMy WebLinkAbout3245-1GENERAL NOTES: 1. ALL WORK SHALL BE IN ACCORDANCE NTH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS A THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK'). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 8, THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 13. STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED. 14. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 15. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 16. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 17. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES, A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 18. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 19. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 20. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 21. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 22. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 23. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 24. IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT. 25. SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700 AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700 FOR V.C.P. 26. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. 27. SHORT VCP STUBS NTH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT. 28. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 29. ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. 30. TERMINATE ALL 4' HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12' BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT OF WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT. 31. THE SEWER CONTRACTOR SHALL STAMP AN "S' IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL. 32. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 33. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 34. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 35. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 36. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 37. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 38. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. PREPARED BY I? ESS/pNq FIRM: raab engineering, 1110. 110 It L. #,4 f4 y� ADDRESS: 310 S. MAPLE ST., STE. D NO. 29616 CO NA, CA 92880 TELEPHONE: ) 272 72 FAX: (909) 272-0166 4 Exp. 3/31/03Om 11 V- � 29616 o D'v �*�9lC r V I L SIGNATURE RCE ATE F aF CAI. H r I\/1 L J rK ELEMENTARY SCHJJL BC LEGEND EC SEWER LINE CL CENTERLINE SEWER LINE PER FLOWLINE CUTTER OTHER SHEET - ---EX S- - EXIST. SEWER LINE FINISHED DIRT STORM DRAIN LINE EXISTING S WATER LINE - --EX W-- - EXIST. WATER LINE W SEWER MANHOLE ST DIRECTION OF FLOW 10+00.00 - - RIGHT OF WAY --221 - - EDGE OF PAVEMENT - CENTERLINE 03 WATER VALVE -0. FIRE HYDRANT 0-0 STREET LIGHT uu HANDICAPPED ACCESS RAMP BC BEGIN CURVE EC END CURVE CL CENTERLINE F.L. FLOWLINE CUTTER F.S. FINISHED SURFACE F. FINISHED DIRT EX EXISTING S SEWERLINE SO STORM DRAIN LINE W WATERLINE ST STREET STATION 10+00.00 SEWER STATION MH MANHOLE INT. INTERSECTION R/W RIGHT OF WAY BASIS OF BEARINGS: � \01 THE BEARING OF N89'54'23'W FOR THE CENTERLINE OF MILLER AVENUE, AS SHOWN ON A RECORD OF SURVEY FILED IN BOOK 59 PAGES 52 THROUGH 62, INCLUSIVE, WAS �P6 USED AS THE BASIS OF BEARINGS FOR THIS MAP. Q BENCH MW: NO. 360 CITY OF FONTANA BENCHMARK #360 - A NAIL IN POLE J1563704E AT THE SOUTHWEST CORNER OF LIME AVENUE AND BASELINE AVE. ELEV. 1316.03 TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT 0 VA CAJNT DENOTES SEE SHEET NO. TABLE 200 -1.2 [A] SIEVE SIZE PERCENTAGE PASSING SIEVES - 1 r .� 3/4' 100 112- 90 - 100 3/81' 20 - 60 NO. 4 0 - 15 N0.8 0-5 ASTM C 131 TEST GRADING B � - - - - - - FOOTHILL BLVD. 3' MAX. SIZE NATIVE SOIL COMPACTED 95% 6' MIN. 10" MAX. 6' MAX. SIZE NATIVE SOIL - COMPACTED 90% TI CITY OF FONTANA ATTN: CARLOS NAVARRO 8353 SIERRA AVENUE FONTANA, CA 92335 (909) 350-6632 SOUTHERN CALIFORNIA GAS COMPANY ATTN: DENNIS FREEMAN 1981 W. LUGONIA AVE. REDLANDS, CA. 92374 (909) 335-7547 EMERGENCIES: (800) 427-2200 SOUTHERN CALIFORNIA EDISON COMPANY 300 N. PEPPER STREET RIALTO, CA 92376 909) 820-5598 -- UNDERGROUND 909 875-5100 -- TRANSMISSION 213) 637-1233 -- PIPELIN S CRAWFORD CANYON MUTUAL 'WATER CO. ATTN: BILL VANDERKIEFT, JRJ (619) 868-6040 TIONS PACIFIC BELL CO. ATTN: VIRGINIA BECKER 3939 E. CORONADO STREET ANAHEIM, CA 92807 (714) 666-5467 UNDEGROUND SERVICE ALERT (800) 422-4133 COMCAST (CABLE TV) ATTN: JACK HAYES 1205 DUPONT AVE. ONTARIO, CA 91761 (909) 390-4738 GENERAL TELEPHONE CO. ATTN: STEVE HOCK 1400 E. PHILLIPS BLVD. ONTARIO, CA. 91766 (800) 422-4133 FONTANA WATER COMPANY AM: MICHAEL J. MCGRAW 8440 NUEVO AVE. FONTANA, CA. 92235 (909) 822-2201 FAX (909) 823-5046 PRIVATE ENGINEER'S NOTES TO CONTRACTOR: THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTIUTY PIPES, CONDUITS OR ANY STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES NOT SHOWN ON THESE 'DRAWINGS. CONTRACTOR AGREES THAT HE/SHE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE CITY, THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION NTH THE PERFORMANCE OF WORK ON THIS PROJECT. EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. 3' MAX. SIZE NATIVE SOIL COMPACTED 95% 6' MIN. 6' MIN. 10' MAX. 10' MAX. TA, CV i I 6' MAX. SIZE NATIVE SOIL • 1 MAX. SIZE COMPACTED 909 1 MAX. SIZE SELECTED NATIVE SELECTED NATIVE BEDDING COMPACTED BEDDING/�DCOMPACTED TO 9091 /TO TYPICAL BEDDING FOR 8" VCP LESS THAN 10' DEEP NOT TO SCALE 1/2' CRUSHED STONE BEDDING PER STD. SPECS. FOR PUBLIC WORKS CONSTRUCTION TABLE 200 1.2 [A] SHOWN $' f.l . N 3 CL o + a � TYPICAL BEDDING FOR 81 VCP 10' OR DEEPER NOT TO SCALE NOR1N CONSTRUCTION NOTES: OUANTITIES: Ui CONSTRUCT SEWER MANHOLE PER CITY OF FONTANA STD. NO. 109, 112, & 114 12 EA. Al 0 CONSTRUCT 8' V.C.P. SEWER MAIN (EXTRA STRENGTH WITH COMPRESSION JOINTS) 2886 LF Q3 CONSTRUCT 4' DIA. (EXTRA STRENGTH V.C.P. LATERAL WITH PLUG PER CITY OF 2130 LF zF001 FONTANA STD. NO. 125 INSTALL SEWER BACKFLOW DEVICE PER AWWA STD. PLANS. 26 EA. REMOVE & REPLACE EXISTING AC PAVEMENT IN KIND PER CITY OF FONTANA STD. 131, 1 LS. AND CURB AND GUTTER PER CITY OF FONTANA STD. 1003. VICINITY MAP NOT TO SCALE REV. REVISION DESCRIPTION DATE ENGR. CITY DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT CITY OF FONTANA, CALIFORNIA COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, DRAWN BY: SEWER PLAN -TRACT 1616 THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO DESIGNED BY: TITLE SHEET BRING THEM INTO CONFORMANCE WITH CONDITIONS AND -� Date,- CHECKED BY: . A_PPRO p BY .a. �-. 6 • • c� t STANDARDS IN EFFECT. -C--Y- ENGINEER R.Q.E. 51152 OATS: PROJECT > SITE I SCALE: la = 100,, DATE: JULY 30, 2002 DRAWING NO.: 1 3245 s