HomeMy WebLinkAbout3229-1GENERAL NOTES
1 ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE
CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN
BOOK")- ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS
OTHERWISE NOTED.
2 WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE
RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL
IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4 ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE WEEK PRIOR
TO IMPLEMENTING DETOURS.
5 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT
DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL
BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
6 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES
DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION
UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
7 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER
TRAFFIC CONTROL DEVICES AT ALL TIMES.
8 THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5
FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
9 THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED
BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF
THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET
SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT.
10 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A
SEPARATE PERMIT FOR THAT PURPOSE.
11 THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT
SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND
ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO.
THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS
BEFORE EXCAVATION.
12 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT
LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC
WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES
SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
13 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE
AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR
VALVE OPERATION AND WATER REQUIREMENTS.
14 STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED.
15 ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR
TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE
PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION.
16 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS
WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
17 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT
TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR.
SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED.
THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO
MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
18 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A
MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS
AND EMERGENCY VEHICLES.
19 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING
ADEQUATE WATERING, AT ALL TIMES.
20 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED
ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT
PRIOR WRITTEN APPROVAL.
21 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
22 A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED
DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS
OBTAINED.
23 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET
IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY
NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
24 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING
CONCRETE.
25 NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY
ENGINEER.
26 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND
LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY
CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
27 IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE
CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY.
28 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED,
INSPECTED AND APPROVED.
29 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS.
30 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
31 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY
THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
32 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES,
AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
33 AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL
PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
34 MINIMUM D -LOAD FOR STORM DRAIN PIPE IS 1350.
PA I?CEL MA P NOo 15 1
NTS
Cl TY OF FON TA NA!
5UN rilvlr' NO'7��
I
j�mc J - ^
INDEX MAP
NTS
Illy
GRANULAR BEDDING FROM
SELECTED TRENCH SIDE
MATERIAL (1" MAX. SIZE).
w
z
0
N
CONSTRUCTION NOTES AND QUANTITY ESTIMATES w
a
0 -
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS:
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES
SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS; TO
THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE
SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE
CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE
UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE
DRAWINGS.
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY
FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS
PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS SHALL
APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS AND THAT THE
CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER
HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED IN CONNECTION WITH
THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING
FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER.
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT
ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK.
CITY OF FONTANA UTILITY NOTIFICATION LIST
CITY OF FONTANA
ATTN: CARLOS NAVARRO
8353 SIERRA AVENUE
FONTANA, CA 92335
(909) 350-6632
SO. CALIFORNIA GAS COMPANY
ATTN. ALAN KESELOFF
16231 VALLEY BLVD.
FONTANA, CA. 92335
(909) 335-7781
EMERGENCIES: (800) 427-2200
SO. CALIFORNIA EDISON COMPANY
ATTN: JAIME AMESZCUA
(909) 357-6581
7951 REDWOOD AVENUE
FONTANA, CA. 92335
(909) 820-5598 UNDERGROUND
(909) 820-5137 TRANSM 15SIONS
(213) 637-1233 PIPELINES
(909) 357-6589 DISTRIBUTION
(800) 227-2600
UNDERGROUND SERVICE ALERT
(800) 227-2600
PACIFIC BELL CO.
ATTN: VIRGINIA BECKER
3939 E.CORONADO STREET
ANAHEIM, CA 92807
(714) 666-5467
COMCAST (CABLE TV)
ATTN: JACK HAYES
1205 DUPONT AVENUE FONTANA,
ONTARIO, CA. 91761
(909) 390-4736 EXT. 3055
FONTANA WATER COMPANY
ATTN: AL KROHN
8440 NUEVO AVENUE
FONTANA, CA 92335
(909) 822-2201 EXT. 323
FAX. (909) 823-5046
CRAWFORD CANYON MUTUAL WATER CO.
ATTN: BILL VANDERKIEFT, JR.
(619) 868-6040
NOTES:
DESCRIPTION
DESCRIPTION
QUANTITIES
1O
INSTALL 36"
RCP, D -LOAD SHOWN ON PROFILE.
12 LF
20
INSTALL 12"
SDR -35 DRAIN PIPE
460 LF
3O
CONSTRUCT
CONC COLLAR PER A.P.W.A. STD. PLAN NO. 380-2
1 EA.
®
INSTALL 12"
SDR -35 45' ELBOW
1 EA.
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS:
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES
SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS; TO
THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE
SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE
CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE
UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE
DRAWINGS.
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY
FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS
PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS SHALL
APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS AND THAT THE
CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER
HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED IN CONNECTION WITH
THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING
FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER.
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT
ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK.
CITY OF FONTANA UTILITY NOTIFICATION LIST
CITY OF FONTANA
ATTN: CARLOS NAVARRO
8353 SIERRA AVENUE
FONTANA, CA 92335
(909) 350-6632
SO. CALIFORNIA GAS COMPANY
ATTN. ALAN KESELOFF
16231 VALLEY BLVD.
FONTANA, CA. 92335
(909) 335-7781
EMERGENCIES: (800) 427-2200
SO. CALIFORNIA EDISON COMPANY
ATTN: JAIME AMESZCUA
(909) 357-6581
7951 REDWOOD AVENUE
FONTANA, CA. 92335
(909) 820-5598 UNDERGROUND
(909) 820-5137 TRANSM 15SIONS
(213) 637-1233 PIPELINES
(909) 357-6589 DISTRIBUTION
(800) 227-2600
UNDERGROUND SERVICE ALERT
(800) 227-2600
PACIFIC BELL CO.
ATTN: VIRGINIA BECKER
3939 E.CORONADO STREET
ANAHEIM, CA 92807
(714) 666-5467
COMCAST (CABLE TV)
ATTN: JACK HAYES
1205 DUPONT AVENUE FONTANA,
ONTARIO, CA. 91761
(909) 390-4736 EXT. 3055
FONTANA WATER COMPANY
ATTN: AL KROHN
8440 NUEVO AVENUE
FONTANA, CA 92335
(909) 822-2201 EXT. 323
FAX. (909) 823-5046
CRAWFORD CANYON MUTUAL WATER CO.
ATTN: BILL VANDERKIEFT, JR.
(619) 868-6040
3/4:1 SLOPE OR GREATER
OR ADEQUATE SHORING
90% COMPACTED
NATIVE BACKFILL
3" MAX. SIZE
NOTES:
�p
6"
MI
III
STA
2. TRENCH DEPTHS OF GREATER THAN 5'
SHORING.
6\1-
SHALL HAVE ADEQUATE
C14
r-
3. CLASS II AGG.BASE ALL TRENCHES
R/W
8
G
III
s
NOTE: COMPACTION SHALL BE 90% IN ALL
WAT
WATER
III =
III
TRENCH STABILITY SHALL CONFORM
VCP
=III
III-
�
•o
-
RIGHT-OF-WAY
III
WATER
DUNCAN
CYN. RD.
w
--__-_____---.------, P ._____.______----_-
- ELECTRIC
- ;A<. _ - --
GAS
T
>
a
— — — — — — — — —
F
�
w
Qf w
w
w
U SUMMIT AVENUE
w
J
V)
J r
U
U
O
SIEPKA
w
LAKES PARKWAY
HIGHLAND
AVENUE
V)
>
Q
Z
N
=
U
w
w
m
BASELINE
AVENUE
3/4:1 SLOPE OR GREATER
OR ADEQUATE SHORING
90% COMPACTED
NATIVE BACKFILL
3" MAX. SIZE
VICINITY MAP
NTS
NOTES:
FL
6"
MI
III
STA
2. TRENCH DEPTHS OF GREATER THAN 5'
SHORING.
MH
SHALL HAVE ADEQUATE
C14
r-
3. CLASS II AGG.BASE ALL TRENCHES
R/W
8
MI
III
s
NOTE: COMPACTION SHALL BE 90% IN ALL
WAT
WATER
III =
III
co
TRENCH STABILITY SHALL CONFORM
VCP
=III
III-
�
•o
-
RIGHT-OF-WAY
III
WATER
SEWER
--__-_____---.------, P ._____.______----_-
VICINITY MAP
NTS
STORM DRAIN PIPE ;7ZGR0.6'D'
ANULAR BEDDING FROM SELECTED
TRENCH SIDE MATERIAL FOR PIPE
10' OR GREATER IN DEPTH USE
1/2 CRUSHED STONE BEDDING.
TRENCH DETAIL
NOT TO SCALE
LEGEND
TC
NOTES:
FL
1. TRENCH WIDTH SHALL BE CONTROLLED
INV
TO TOP OF PIPE ZONE.
STA
2. TRENCH DEPTHS OF GREATER THAN 5'
SHORING.
MH
SHALL HAVE ADEQUATE
CB
3. CLASS II AGG.BASE ALL TRENCHES
R/W
LESS THAN 100' IN LENGTH.
—_III
CENTERLINE
III =
_—III
III =
III
NOTE: COMPACTION SHALL BE 90% IN ALL
WAT
WATER
ZONES UNLESS OTHERWISE SPECIFIED.
III
co
TRENCH STABILITY SHALL CONFORM
VCP
n
TO CAL–OSHA REQUIREMENTS.
STORM DRAIN PIPE ;7ZGR0.6'D'
ANULAR BEDDING FROM SELECTED
TRENCH SIDE MATERIAL FOR PIPE
10' OR GREATER IN DEPTH USE
1/2 CRUSHED STONE BEDDING.
TRENCH DETAIL
NOT TO SCALE
LEGEND
TC
TOP OF CURB
FL
FLOW LINE (GUTTER)
INV
INVERT ELEVATION
STA
STATION
MH
MANHOLE
CB
CATCH BASIN
R/W
RIGHT-OF-WAY
CL
CENTERLINE
SD
STORM DRAIN
WAT
WATER
SEW
SEWER
RCP
REINFORCED CONCRETE PIPE
VCP
VITRIFIED CLAY PIPE
- - -
CENTERLINE
®--®--
RIGHT-OF-WAY
_.
WATER
SEWER
--__-_____---.------, P ._____.______----_-
- ELECTRIC
- ;A<. _ - --
GAS
T
TELEPHONE
— — — — — — — — —
— EASEMENT
1 \� 9R_1 dFR\etnrm\Cfl_Rloor�or_M rhA,n n7/7r.P 0t*f0 A0 -'1A -f;9 ORA en