Loading...
HomeMy WebLinkAbout3227-19-4 o� J pt 31A 1'/4 I") RR I C AT 1 ON LEC END TORO 570 Z-PRX-6P-COM-8F FULL SPRAY HEAD 8' 1.0 30 SYMBOL MFG. MODEL NO. DESCRIPTION RAD. GPM PSI i TORO 570 Z-PRX-12P-COM-80 QUARTER SPRAY HEAD 8' .25 30 • TORO 570 Z-PRX-12P-COM-8H HALF SPRAY HEAD 8' .50 30 0 TORO 570 Z-PRX-12P-COM-8F FULL SPRAY HEAD 8' 1.0 30 1511.65 TORO 570 Z-PRX-12P-COM-12Q QUARTER SPRAY HEAD 12' .50 30 CO TORO 570 Z-PRX-1 2P -COM -1 2H HALF SPRAY HEAD 12' 1.09 30 Q TORO 570 Z-PRX-12P-COM-12F FULL SPRAY HEAD 12' 2.19 30 TORO 570 Z-PRX-1 2P -COM -1 5Q QUARTER SPRAY HEAD 15' .85 30 p TORO 570 Z-PRX-12P-COM-15H HALF SPRAY HEAD 15' 1.65 30 @ TORO 570 Z-PRX-1 2P -COM -1 5F FULL SPRAY HEAD 15' 3.60 30 I] TORO 570Z-PRX-12P-COM-2SST STRIP SPRAY HEAD 2X6' .09 30 Il TORO 570Z-PRX-12P-COM-4EST END SPRAY HEAD 4X15' .45 30 0 TORO 570Z-PRX-12P-COM-4SST STRIP SPRAY HEAD 4X30' .90 30 TORO 570 Z-PRX-6P-COM-8Q QUARTER SPRAY HEAD 8' .25 30 V TORO 570.Z-PRX-6P-COM-8H HALF SPRAY HEAD 8' .50 30 ♦Q TORO 570 Z-PRX-6P-COM-8F FULL SPRAY HEAD 8' 1.0 30 01-037 TORO 570 Z-PRX-6P-COM-120 QUARTER SPRAY HEAD 12' .50 30 r- — ® TORO 570 Z-PRX-6P-COM-12H HALF SPRAY HEAD TORO 570 Z-PRX-6P-COM-12F FULL SPRAY HEAD 12' 12' 1.09 2.19 30 30 2� ,/ i" 17 TORO 570 Z-PRX-6P-COM-150 QUARTER SPRAY HEAD 15' .85 30 TORO 570 ZPRX-6P COM 15H HALF SPRAY HEAD 1511.65 O 30 2 @ TORO 570 Z-PRX-6P-COM-15F FULL SPRAY HEAD 15' 3.6 30 �� IR TORO 570 Z-PRX-6P-SB-2-180-PC2. STREAM BUBBLER 2X6' .09 30 570 Z-PRX-6P-SB-90-PC2 / 4 (CONTRACTOR TO DECIDE IN FIELD WHICH BUBBLER TO INSTALL) CONTRACTOR MUST USE TORO 570 ADJUSTABLE ARC NOZZLES OR 570 V-15 / / ♦ —1 4 / ?' 0 %4111 1,,4 It 1'/2 11/211 it NOZZLES TO AVOID OVERSPRAY AND INSURE FULL COVERAGE. 3 3' 3 1,, 3i4 1 4 THE CONTRACTOR MAY USE STANDARD RISERS IN SHRUB AREAS THAT ARE 1000,/4 3/4" ADJACENT TO WALLS OR BUILDINGS OR WHERE PEDESTRIAN TRAFFIC WILL NOT / f /4 OCCUR. THE CONTRACTOR IS REQUIRED TO USE 570Z -COM (CHECK-O-MATIC) % / ` / 1" POP-UP BODY'S ON ANY HEADS ON A SYSTEM WITH TOR GREATER THAN / •• 11/211 ELEVATION CHANGE- OR AS NEEDED IN FIELD. THE 8' SPRAY HEADS MAY BE SUBSTITUTED WITH 10' NOZZLES AS REQUIRED IN THE FIELD. ANY HEADS THE NEED A REDUCTION OF MORE THAN 50% OF THE LISTED SPRAY PATTERN WILL REQUIRE TORO PCD SCREENS. 0 2" DOMESTIC WATER METER - REFER TO CIVIL PLANS. FEBCO 825Y 2" REDUCED PRESSURE BACKFLOW PREVENTER IN LEMUR VANDAL- / RESISTANT STEEL MESH ENCLOSURE - SEE DETAILS / NIBCO T-113 GATE VALVE (3" OR SMALLER) - LINE SIZE / Locate in a 10" round lockable plastic valve box. THOMPSON HI -FLOW BRASS ELECTRIC PRESSURE REGULATING REMOTE CONTROL VALVE / (SIZE INDICATED) / Locate in a 12" x18"rectangular lockable plastic valve box per valve. / All valves and plastic valve boxes to be numbered. / Q GRISWOLD 2230 MASTER VALVE / PRESSURE REGULATOR 21/2". C`' ® RAINBIRD QUICK COUPLER 33D - Locate in a 10" round lockable plastic valve box @ 150' o.c. maximum. Support with a sch 40 pvc pipe stake and two house clamps / each. �O /� � 4"0 / V AUTOMATIC CONTROLLER LOCATION (SEE CONTROLLER ENCLOSURE DETAIL ON SHEET L-15 FOR MFG. & MODEL) Provide controller charts per City requirements. Contractor to also install a Rainguard moisture sensor @ the controller. Locate in a vandal resistant area free from overhead obstruction and outside of the irrigation spray pattern. PVC SCH. 40 MAINLINE- 1-1/2" AND SMALLER. PVC CLASS 315,2" AND LARGER. 24" COVER UNDER PAVING, 18" COVER IN PLANTING AREAS, SIZES AS INDICATED. / PVC CLASS 200 LATERAL LINE- 12" COVER IN PLANTING AREAS. PVC SCHED. 40- 24" COVER UNDER PAVING i PVC SCH 40 MAIN AND LATERAL LINE SLEEVE 2x DIAMETER OF PIPE / Pipe, controller wires and communication cable to be 24" deep under paving and 18" below walls. V 2/ SCH. 40 WIRE SLEEVE - Locate in a seperate trench per UBC and City Specifications. Q� INDICATES VALVE NUMBER e INDICATES CONTROLLER \� / o INDICATES VALVE GPM L T INDICATES VALVE SIZE P.A. 8B 21/211 i 3/4 1 611�4' 24 3/4 n O 1" 25 3,4 u 23 0 B 1" 1u 1% 0 1'/2 11/41, 17 �� NOTE: THE IRRIGATION SYSTEM AT LOT 'A' WILL RECEIVE POWER AND WATER FROM THE AUGUSTA DRIVE 'B' SYSTEM. CORNER LOTS 35 & 36 CURRENTLY HAVE EXISTING FRONT YARD LANDSCAPING. THE NEW MAINLINE AND CONTROL WIRES FOR LOT 'A' WILL BE INSTALLED WITHIN 24" BEHIND SIDEWALK. CONTRACTOR TO REPAIR OR REPLACE ANY LANDSCAPE IRRIGATION OR CONSTRUCTION ITEMS DAMAGED OR DISTORTED DURING CONSTRUCTION. CONTRACTOR TO PROVIDE HAND WATERING TO THE EXISTING LANDSCAPE DURING CONSTRUCTION. FLUSH AND ADJUST THE EXISTING FRONT YARD IRRIGATION SYSTEM TO INSURE FULL COVERAGE. ♦ � o0 ,,, �♦ --Ij 3/411 G lit <J N r� \ 1 \� 44+00.00 cL AUGUSTA LACE 4 ' It =0+00. 00 c l AVENAL PLACE I'T B "ft 4 X1,,4 It I 3/4 \\ 3/4 1 3 11` ~ v L 3,41' 16 B „ 1 1 22 , u 1 /4 18 S 111722 0 �I �� ' 3,4 u 2 t" 22 / 16 .4 1" 12 3/4 u ® / 1 44 renow I �. 77 za- 0� ®23.+ ►., "X iLi a i _L e w .LJ a✓ A v X'%_ --& `& t1 A. JL -L v 1 F CITRUS AVENUE ab Ix/ F T IL • � FY a I `aH D S Cq p SHEET KEY (y� �9C ~ `� 2782 yGs y'I O r,11 9�F OF CAS\ CITY OF F® TAA LANDSCAPE PLANS AUGUSTA DRIVE II ZESIMM BY. cicM rnnovEo an CM ormefle :=M MATE 5'1152 SCALE 1"=20' AS SHOWN »~TEI DWI& NM 3227 %A s 1 T e s C w P IE 5 Landscape Architecture and Planning 19762 MacArthur Blvd., Ste. 130 Irvine, CA. 92612 Richard Polhamus, License CA—#2"M (949) 644-9370 (949) 476-1432'W Q4 O r-� + H � d°O' W • O -i- W F�—•I F--� W >� H C� o a �C) w� ��Z QO of 0 P4 D1NN CHIC N 05/14/02 JOB* 01-037 w j 00 �� w O tA O., 00 w't..4�o V1 �I D1NN CHIC DATE 05/14/02 JOB* 01-037