HomeMy WebLinkAbout3227-17CITRUSAVENUE 3/ It r LIMIT OF 0 3/41, /4, 3 / /4 „ T 3/4 4 I I t I 3,4,i It I I I .I 12\D i � I 3/4, '1 � 4"I i 25 1'/4 tm D 1 D.4 24 24 I I 16 m 11,2 111411 Ito 4' 1,2 It s --r--� 1' 11/ 1,,2 F I 1,. � � 1 I I I � ` w 3/4 , " `r b a g 14, zM ! 11/21 } 1„ 2 1Z D I" 26 ` 3/4 11,4u 1 u I 3 _" 3/4 " �, P.O.C. CONTRACTOR TO PULL ALL , , _-►' _ - _ y /4" I 2" REMAINING 'D' CONTROL 3 ' M M WIRES AND 2 COMMON 4 I 6 "��4110 WIRES TO THIS LOCATION 9 i IRRIGATION WORST CONDITION ' C ' & 'D' STATIC PRESSURE: 92.4 PSI DESIGN PRESSURE: 68.4 PSI (2) VALVES SIMULTANIOUSLY - VALVES: C6/C2 GPM: 65 SIZE ITEM PSI 2" WATER METER 3.2 2" BACKFLOW DEVICE 12 21/211 GATE VALVE 1.4 21/211 CLASS 315 MAINLINE 7.26 11/211 REMOTE CONTROL VALVE 3.4 CLASS 200 PVC LATERAL LINES 5.0 TOTAL SYSTEM LOSS 32.26 IRRIGATION HEAD PRESSURE 30.00 10% RESIDUAL PSI 6.22 POINT OF CONNECTION: 'C' & 'D' 2" WATER METER, REFER TO CIVIL PLANS. CONTRACTOR TO INSTALL A 2" FEBCO 825YA REDUCED PRESSURE TYPE BACKFLOW PREVENTER AND LOCATE IN A LEMEUR VANDAL - RESISTANT STEEL MESH ENCLOSURE. COORDINATE LOCATION WITH CITY INSPECTOR. (SCREEN WITH SHRUBS) STATIC PRESSURE: 92.4 PSI DESIGN PRESSURE: 68.4 PSI MAXIMUM DEMAND: 65 GPM CONTROLLER: 'C' & 'D' (STREETSCAPE) CONTRACTOR TO INSTALL (2) TORO NETWORK 8000 FIELD SATELLITE CONTROLLERS. CONTROLLERS TO BE MUST INCLUDE A RADIO CONTROL AND PHONE MODEM. COORDINATE LOCATION WITH CITY INSPECTOR. LOCATE CONTROLLER'C' IN A STRONG BOX (SB-24SS-120V) AND CONTROLLER'D' IN A STRONG BOX (SB-24SS) (VERIFY WITH FIELD INSPECTOR PRIOR TO PURCHASE OR INSTALLATION) ENCLOSURE. SEE SITE ELECTRICAL PLANS. LOCATE "LABELED" WIRES IN A 36" LOOP LLOOP O WIELED RES PA WITH P.A. 7 3,41' Q 2 118 3/4 8C 7 - I - t' / 1 ,�„ Jim, 1 i2 29 0111111, _ ,r aF. SZGHTi�N� '.,•- ..,,, � 34 ' 6 v- -a. 3/4 1„ 1" 24 _lID♦ O ..., -rte .,,,. "•.. / . ` -•,• .-.,. , 4 �' ' 11/4' 1 S 31+70. 50 -1 AUGUSTADRIVE ° - � 11/2 ' ,4 �% I/ 1 4 =14+01.66 ct MUIRFILED LANE 21/2�� � v AUCUS � s •,,., /4 4„ Iii 1' � 3 i, 2 1,12 2 21/21 11/2 t _ _ _ - ,4„ 4 3 Am -'Tr . -. 4 3 it12 3/4 I _ .. .. 3/ 4 11/4 1i ` ` 2,, 3 u 3 11 3/ 1' .............. ... 4....1,4 Tn.. . ... .... . . it .......... 11/4 �` 2,,11 4 \'1E�F SIGHT 4 'm 1 20 • - • ` "•.... ` �\\ \\ \Cyr CONTRACTOR TO PULL ALL 1'2 22 GOLF COUR E • .6 "� \ _ 21 ,2 REMAINING'C' CONTROL �,-- ...._._ .�._. _ . � ._ __.. ... _ a z1 1 ,1 ` 21/2 ° WIRES AND (2) COMMON ! 2- 1 ~-• 35+04.71 C1 AUGUSTA DRi WIRES TO THIS LOCATION. I" ' 1+f� c ," ,,, `� 3S =0+00.00 c I ' DD' STRE LOCATE "LABELED" WIRES IN t 1 33 6 c A LABELED VALVE BOX WITH� I° 15 A 36" LOOP TO WIRES / t `- `�, € 1t P. A. 6 j, i .. t 3/4 I �s i O r r� I IRR 15AT I ON LEC END SYMBOL MFG. MODEL NO. DESCRIPTION RAD. GPM PSI ill TORO 570 Z-PRX-12P-COM-80 QUARTER SPRAY HEAD 8' .25 30 • TORO 570 Z-PRX-12P-COM-8H HALF SPRAY HEAD 8' .50 30 TORO 570 Z-PRX-12P-COM-8F FULL SPRAY HEAD 8' 1.0 30 (� TORO 570 Z-PRX-1 2P -COM -1 20 QUARTER SPRAY HEAD 12' .50 30 0 TORO 570 Z-PRX-1 2P -COM -1 2H HALF SPRAY HEAD 12' 1.09 30 TORO 570 Z-PRX-12P-COM-12F FULL SPRAY HEAD 12' 2.19 30 TORO 570 Z-PRX-12P-COM-15Q QUARTER SPRAY HEAD 15' .85 30 0 TORO 570 Z-PRX-1 2P -COM -1 5H HALF SPRAY HEAD 15' 1.65 30 @ TORO 570 Z-PRX-12P-COM-15F FULL SPRAY HEAD 15' 3.60 30 CI TORO 570Z-PRX-12P-COM-2SST STRIP SPRAY HEAD 2X6' .09 30 0 TORO 570Z-PRX-12P-COM-4EST END SPRAY HEAD 4X15' .45 30 ® TORO 570Z-PRX-12P-COM-4SST STRIP SPRAY HEAD 4X30' .90 30 + TORO 570 Z-PRX-6P-COM-8Q QUARTER SPRAY HEAD 8' .25 30 V TORO 570 Z-PRX 6P -COM -8H HALF SPRAY HEAD 8' .50 30 TORO 570 Z-PRX-6P-COM-8F FULL SPRAY HEAD 8' 10 30 d► TORO 570 Z-PRX-6P-COM-12Q QUARTER SPRAY HEAD 12' .50 30 ® TORO 570 Z-PRX-6P-COM-12H HALF SPRAY HEAD 12' 1.09 30 TORO 570 Z-PRX-6P-COM=12F FULL SPRAY HEAD 12' 2.19 30 TORO 570 Z-PRX-6P-COM-150 QUARTER SPRAY HEAD 15' .85 30 V TORO 570 Z-PRX-6P-COM-15H HALF SPRAY HEAD 15' 1.65 30 v@ TORO 570 Z-PRX-6P-COM-15F FULL SPRAY HEAD 15' 3.6 30 ® TORO 570 Z-PRX-6P-SB-2-180-PC2 STREAM BUBBLER 2X6' .09 30 570 Z-PRX-6P-SB-90-PC2 rl (CONTRACTOR TO DECIDE IN FIELD WHICH BUBBLER TO INSTALL) CONTRACTOR MUST USE TORO 570 ADJUSTABLE ARC NOZZLES OR 570 V-15 NOZZLES TO AVOID OVERSPRAY AND INSURE FULL COVERAGE. THE CONTRACTOR MAY USE STANDARD RISERS IN SHRUB AREAS THAT ARE ADJACENT TO WALLS OR BUILDINGS OR WHERE PEDESTRIAN TRAFFIC WILL NOT OCCUR. THE CONTRACTOR IS REQUIRED TO USE 570Z -COM (CHECK-O-MATIC) POP-UP BODY'S ON ANY HEADS ON A SYSTEM WITH 3' OR GREATER THAN ELEVATION CHANGE- OR AS NEEDED IN FIELD. THE 8' SPRAY HEADS MAY BE SUBSTITUTED WITH 10' NOZZLES AS REQUIRED IN THE FIELD. ANY HEADS THE NEED A REDUCTION OF MORE THAN 50% OF THE LISTED SPRAY PATTERN WILL REQUIRE TORO PCD SCREENS. a 2" DOMESTIC WATER METER - REFER TO CIVIL PLANS. FEBCO 825Y 2" REDUCED PRESSURE BACKFLOW PREVENTER IN LEMUR VANDAL - RESISTANT STEEL MESH ENCLOSURE - SEE DETAILS ►/ NIBCO T-113 GATE VALVE (3" OR SMALLER) - LINE SIZE Locate in a 10" round lockable plastic valve box. THOMPSON HI -FLOW BRASS ELECTRIC PRESSURE REGULATING REMOTE CONTROL VALVE (SIZE INDICATED) Locate in a 12" x18"rectangular lockable plastic valve box per valve. All valves and plastic valve boxes to be numbered. Q GRISWOLD 2230 MASTER VALVE / PRESSURE REGULATOR 21/2". O RAINBIRD QUICK COUPLER 33D - Locate in a 10" round lockable plastic valve box @ 150' o.c. maximum. Support with a sch 40 pvc pipe stake and two house clamps each. 0 AUTOMATIC CONTROLLER LOCATION (SEE CONTROLLER ENCLOSURE DETAIL ON SHEET L-15 FOR MFG. & MODEL) Provide controller charts per City requirements. Contractor to also install a Rainguard moisture sensor @ the controller. Locate in a vandal resistant area free from overhead obstruction and outside of the irrigation spray pattern. _ _ ,_, PVC SCH. 40 MAINLINE -1-1/2" AND SMALLER. PVC CLASS 315,2" AND LARGER. 24" COVER UNDER PAVING, 18" COVER IN PLANTING AREAS, SIZES AS INDICATED. PVC CLASS 200 LATERAL LINE- 12" COVER IN PLANTING AREAS. PVC SCHED. 40- 24" COVER UNDER PAVING PVC SCH 40 MAIN AND LATERAL LINE SLEEVE 2x DIAMETER OF PIPE Pipe , controller wires and communication cable to be 24" deep under paving and 18" below walls. - - - SCH. 40 WIRE SLEEVE - Locate in a seperate trench per UBC and City Specifications. INDICATES VALVE NUMBER a- INDICATES CONTROLLER INDICATES VALVE GPM INDICATES VALVE SIZE i , SHEET L - Q \j%0SC4;* 10 A. P pl HIt 4 q pel ��`� 2782 KGs te" ar PGRATU 1Q- �� DATE WIN �F CA�- SHEET KEY CITY OF FO TA A LANDSCAPE PLANS BMW AUGUSTA DRIVE II DESIGNED IM 004 S CHECKED47�4" • It mrE� CRY ENmlVEt ILM-eSEV EW. DATE )irsl r5z SCMD AS SHOWN DATE, Drys Nu+ 3227 -91TescAP1eT; Landscape Architecture and Planning 19762 MacArthur Blvd., She. 130 IrvTne, CA. 92612 Richard Polho"we. License CA -#2782 (949) 844-9370 (949) 476-1432 FAX DVM CHK DATE 05/14/02 '®B * 01-037 16 of 23 NINC W >� 00 W 0.. 00 L U Q-0 O 51,, tin rl DVM CHK DATE 05/14/02 '®B * 01-037 16 of 23