Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3227-16
IRRIGATION LEGEND SYMBOL MFG. MODEL NO. DESCRiPTON RAD. GPM PSI QTY. 4 TORO 570 Z-PRX-12P-COM-80 QUARTER SPRAY HEAD 8' .25 30 ® TORO 570 Z-PRX-12P-COM-8H HALF SPRAY HEAD 8' .50 30 �rV TORO 570 Z-PRX-12P-COM-8F FULL SPRAY HEAD V 1.0 30 (� TORO 570 Z-PRX-12P-COM-12Q QUARTER SPRAY HEAD 12' .50 30 ® TORO 570 Z-PRX-12P-COM-12H HALF SPRAY HEAD 12' 1.09 30 TORO 570 Z-PRX-12P-COM-12F FULL SPRAY HEAD 12' 2.19 30 TORO 570 Z-PRX-12P-COM-150 QUARTER SPRAY HEAD 15' .85 30 2852 0 TORO 570 Z-PRX-12P-CONI-15H HALF SPRAY HEAD 15' 1.65 30 Q TORO 570 Z-PRX-12P-COM-15F FULL SPRAY HEAD 15' 3.60 30 E7 TORO 570Z-PRX-12P-COM-2SST STRIP SPRAY HEAD 2X6' .09 30 11 TORO 570Z-PRX-12P-COM-4EST END SPRAY HEAD 4X15' .45 30 0 TORO 570Z-PRX-12P-COM-4SST STRIP SPRAY HEAD 4X30' .90 30 i TORO 570 Z-PRX-6P-COM-8Q QUARTER SPRAY HEAD 8' .25 30 ® TORO 570 Z-PRX-6P-COM-8H HALF SPRAY HEAD 8' .50 30 sQ TORO 570 Z-PRX-6P-COM-8F FULL SPRAY HEAD V 1.0 30 �► TORO 570 Z-PRX-6P-COM-12Q QUARTER SPRAY HEAD 12' .50 30 3110 V TORO 570 Z-PRX-6P-COM-12H HALF SPRAY HEAD 12' 1.09 30 TORO 570 Z-PRX-6P-COM-12F FULL SPRAY HEAD 12' 2.19 30 d7 TORO 570 Z-PRX-6P-COM-15Q QUARTER SPRAY HEAD 15' .85 30 O TORO 570 Z-PRX-6P-COM-15H HALF SPRAY HEAD 15' 1.65 30 rJp TORO 570 Z-PRX-6P-COM-15F FULL SPRAY HEAD 15' 3.6 30 ® TORO 570 Z-PRX-6P-SB-2-180-PC2 STREAM BUBBLER 2X6' .09 30 570 Z-PRX-6P-SB-90-PC2 (CONTRACTOR TO DECIDE IN FIELD WHICH BUBBLER TO INSTALL) CONTRACTOR MUST USE TORO 570 ADJUSTABLE ARC NOZZLES OR 570 V-15 NOZZLES TO AVOiD OVERSPRAY AND INSURE FULL COVERAGE. THE CONTRACTOR MAY USE STANDARD RISERS IN SHRUB AREAS THAT ARE ADJACENT TO WALLS OR BUILDINGS OR WHERE PEDESTRIAN TRAFFIC WILL NOT OCCUR. THE CONTRACTOR iS REQUIRED TO USE 5702 -COM (CHECK-O-MATIC) POP-UP BODY'S ON ANY HEADS ON A SYSTEM WITH 3' OR GREATER THAN ELEVATION CHANGE- OR AS NEEDED IN FIELD. THE 8' SPRAY HEADS MAY BE SUBSTITUTED WITH 10' NOZZLES AS REQUIRED IN THE FIELD. ANY HEADS THE NEED A REDUCTION OF MORE THAN 50% OF THE LISTED SPRAY PATTERN WILL REQUIRE TORO PCD SCREENS. 7 2" DOMESTIC WATER METER - REFER TO CIVIL PLANS. 4 FEBCO 825Y 2" REDUCED PRESSURE BACKFLOW PREVENTER IN LEMUR VANDAL- 4 RESISTANT STEEL MESH ENCLOSURE - SEE DETAILS 13 @ 2" NIBCO T-113 GATE VALVE (3" OR SMALLER) - LINE SiZE 23 @ 21/2" Locate in a 10" round lockable plastic valve box. 7 @ 3" THOMPSON HI -FLOW BRASS ELECTRIC PRESSURE REGULATING REMOTE CONTROL VALVE 73 @ V (SIZE INDICATED) 52 @ 11/2" Locate in a 12" x18"rectangular lockable plastic valve box per valve. All valves and plastic valve boxes to be numbered. Q GRISWOLD 2230 MASTER VALVE / PRESSURE REGULATOR 21/2". 4 ® RAINBIRD QUICK COUPLER 33D - Locate in a 10" round lockable plastic valve box 59 @ 150' o.c. maximum. Support with a sch 40 pvc pipe stake and two house clamps each. AUTOMATIC CONTROLLER LOCATION (SEE CONTROLLER ENCLOSURE DETIAL 6 ON SHEET L-15 FOR MFG. & MODEL) Provide controller charts per City requirements. Contractor to also install a Rainguard moisture sensor @ the controller. Locate in a vandal resistant area free from overhead obstruction and outside of the irrigation spray pattern. 4540 LN. FT. @ 2" 2375 LN. FT. @ 21/2" PVC SCH. 40 MAINLINE- 1-1/2" AND SMALLER. PVC CLASS 315, 2" AND LARGER. 2156 LN. FT. @ 3" 24" COVER UNDER PAVING, 18" COVER IN PLANTING AREAS, SIZES AS INDICATED. 19496 LN. FT. @ 3/4" PVC CLASS 200 LATERAL LINE -12" COVER IN PLANTING AREAS. 9855 LN. FT. @ 1" PVC SCHED. 40- 24" COVER UNDER PAVING 3675 LN. FT. @ 11/4" 2027 LN. FT. @ 11/2" -' -_ - - PVC SCH 40 MAIN AND LATERAL LINE SLEEVE 2x DIAMETER OF PIPE - ! Pipe, controller wires and communication cable to be 24" deep under paving and 3010 LN. FT. 18" below walls. --- - -- SCH. 40 WiRE SLEEVE - Locate in a seperate trench per UBC and City Specifications. IN FiELD INDICATES VALVE NUMBER �--- INDICATES CONTROLLER INDICATES VALVE GPM INDICATES VALVE SIZE DIAGRAMMATIC PLAN THIS SYSTEM IS DIAGRAMMATIC. ALL PIPE, VALVES, ETC. SHOWN WITHIN PAVED AREAS ARE FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED IN PLANTING AREAS AND JOINT TRENCHES WHEREVER POSSIBLE. SPRINKLER ADJUSTMENT REQUIRED THE IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLER HEADS FOR OPTIMUM PERFORMANCE AND PREVENT OVERSPRAY ONTO WALKS AND ROADWAYS AS MUCH AS POSSIBLE. THIS SHALL INCLUDE SELECTING THE BEST DEGREE OF ARC TO FIT THE EXISTING SITE CONDITIONS. CONTRACTOR TO USE PRESSURE COMPENSATING SCREENS WHEN RADIUS IS REDUCED MORE THAN FIFTY PERCENT (50%). FIELD CONDITIONS DO NOT WILLFULLY INSTALL THE SPRINKLER SYSTEM AS INDICATED ON THE DRAWINGS WHEN IT IS OBVIOUS IN THE FIELD THAT UNKNOWN OBSTRUCTIONS OR GRADE DIFFERENCES EXIST AND SHOULD BE BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER. IN THE EVENT THAT THIS NOTIFICATION IS NOT PERFORMED, THE CONTRACTOR MUST ASSUME FULL RESPONSIBILITY FOR ANY REVISIONS REQUIRED. SWING JOINTS INSTALL ALL HEADS WITH DOUBLE OR TRIPLE SWING JOINTS, USING STREET ELLS, AS PER DETAIL. MINIMUM PRESSURE AND MAXIMUM GALLONS REQUIRED THE SPRINKLER SYSTEM DESIGN IS BASED ON A MINIMUM OPERATIONAL PRESSURE AND A MAXIMUM DEMAND AT THE POINT OF CONNECTION, AS NOTED ON THE PLAN. BEFORE INSTALLING THE SYSTEM, CHECK POINT OF CONNECTION AND IMMEDIATELY NOTIFY CONTRACTING OFFICER IF PRESSURE IS NOT AS NOTED OR THE REQUIRED GALLONS PER MINUTE IS NOT AVAILABLE. WATER LINE UNDER PAVING ALL MAINLINE UNDER PAVING SHALL BE INSTALLED 24" DEEP. ALL LATERAL LINES UNDER PAVING SHALL BE SCH 40 PVC AND INSTALLED 24" DEEP. SYSTEM COVERAGE THE IRRIGATION CONTRACTOR IS TO ADJUST HEAD LOCATIONS IN THE FIELD IN ORDER TO GUARANTEE 100% COVERAGE. CONTRACTOR TO CONTACT THE CONTRACTING OFFICER PRIOR TO ANY MAJOR CHANGE(S) RESULTING IN ADDITIONAL COST TO THE OWNER. PROVIDE 40 AMP - 2 POLE SWMAKM POR NEW PNI'1P6 WHSRS APPLICADLS 111mid CXNT 80 A &U11 OP owl? -MINI = 46'W X 18"D X 54" HIGH AND 12012419 812]1 OP C.O M BLAS • 82'W X 24'0 X 9" THICK 0 3W W/e4 WMARS AT 12" Off, TYP 12 CHI PAM91. -_, a"D1A.X12"0. L _ _ J W i ICMLE86 6140UND WRILL PINI&HSD d134Us ," WITH PARKWAY COYER, PILL WITH PSA GRAYS{. "{• Ty". 8M"DIA X 1V ORNEN AROUND GROUND POR MACTRiC:AL •;. ,,,. ROD PSR ARTICLE 260-81 OP MW NW 3!4"0, Ppb NOTE: AL1. POW@R WIRER, OROLThM WINM ISTO. BEFALL BE &w,ARAn LY eLQvfD AND eWEPr THRovem W40LONO PAD WITH SCH 40 RIGID CONDUIT IRRIGATION CO*ITROL 1 I i-' II 1 II .I I I I i '- bShISRAL NOTS&, PROVICM 100A METER AND DOA/110 MAIN " WHOM N VICAT" ON DRAWN06 aorre+ere�e eue PROVIDS PANILBOARD WHOM INDICATED ON DRAWING&i. PROVIDE IRRIGATION CONTROLLER CASNST WHOM INDICATED ON ORAWN�IC�&. TSRMINATS AT WWICN HANDHOM RM &.0A COMPANY REQ. VWIPY EXACT LOCATION AND 7SRMNdATION REQ. WITH S4JL CO. 9"ceplIM? on PRIOR TO TRENCHING dMIDUND 111100 NWrA6LATWN CONDUIT AND CONDUCTOR 61=15 ARL DA MD ON NONPVrALLdC CONDUIT -2 EXTRA I" MliMIr i6 AND COPPER CCNDUCTORB WITH TTrR `HHN/THWN" N&ULATION. �--- 24" --�-� EltACT LOCA7fON OP CONTROLLER &HALL 15111 ""M UPON irr imlis J, OITY LAhcec.APC M &PaCTOR AND CONTRACTOR PRIOR TO ANY tRMAICHINGY OR ,4-mll 111 PAG'!& STRONG BOX 811>Sri' CONDUIT Pm lit"& GONTROLU R NT'S MODEL NO. SB- 246e 20Y r!" N mi em eWrRr aormulT roR It0.L0 � W"M FRONT ViEW NTS 12' MAX 4' WRiP WiRBS APPROX "" MWM WD5 step t TWiST CONNECTOR I NTiL WIRE 1N REACHES 90TTCM BTeP 2 MIX CONTENTS OP 8rJ1LiNG PACK, CUT 14 Oi P BIND CP PACK AND I ORWr'C 7NNiiGTOR TO oPPOSiTE eNn i als 3 WRAP OM N ONO OP WALINGPACK WiTH TAP=. ALLOW TO 81sT UNTIL WMIN JELLS EE STEP 4 "SCOTCH" BPALi O PACK I .31-41 MAX - li at&rA*ICE� 111 04" DIAMETER STILL POST CAP SECURE TO PIPE. TIPPING DUCKY HRACKM 11/2" DIA PLEXIBLE ALL WEATHER ELECTRICAL CONDUIT, CONNECT BOX TO BOX 4O41PPING BUCKET RAIN GAUGE, INSTALL PER MANUFACTURERS RECOMMENDATIONS. (a)4" DIA GALVANIZED STEEL PIPE POST. © WEATHER PROOF ELECTRICAL "J"BOX DRILL t" DIA HOLE THROUGH PIPE AND MOUNT BOX TO PIPE. O1 SLOPE TOP OF FOOTING AWAY I -ROM PIPiL ®FINISH SURFACE. ® NATURAL COMPACTED SOIL. © 1" MIA ELECTRICAL PVC RIDGED CONDUIT PROM Pips TO CONTROLLER ii. PROPOSED CONTROLLER ENCLOSURE @ STAINLESS STEEL HOSE CLAMPS C2XACH NOTE: ACID WASH STEEL PiPE POST, STEEL POST CAP AND ELECTRICAL "J" BOX THOROUGHLY. PAINT WITH i COAT RUSTOLEUM PRINTER AND 2 COATS OP POREST ORM EXTERIOR HiGH GI.OSS PAINT. CITY OF FONTANA IRRIGATION CONTROLLER STANDARD FOR COMMUNITY FACILITIES DISTRICTS (CFD`S) 1. Toro Network 8000 Model # 132-86-08, 32 station field satellite controller. 2. Mount in Strong Box Model No. SB-24SS/120V. (Stainless Steel) 3. Provide Rainmaster 32 PC 'Pigtail' for remote controll operation. 4. Provide Cambell Scientific Inc,TE525 tipping bucket (Heavy Duty Model) 5. Provide Sensor Input Board (SIB) Model #995-63 to interface with flow meter and rain shut off device. 6. Provide Radio Link Kit #89-7611 to communicate with central command. All radio equipment shall be compatible with VHF. 7. Provide ground rod and surge protection for each satellite controller. Contact: Curtis Newman California Turf (619) 520-6181 (619) 793-3999 (Pager) (800) 774-8873 (Main Office) Park and Landscape Development Section, Engineering Division Community Development Department, City of Fontana (1/26/98) 2782 ��� CITY OF FONTANA LANDSCAPE PLANS AUGUSTA DRIVE II scmz sxowN nestcaen >nn DATES Dift 9TE Of CA1.��o� BY, PY6BY- WS k& 16 3227 24 LT" ace ewes M. DATE j 1 T L`S C A P IE�' Landscape Architecture and Planning 19762 MacArthur Blvd.. Ste. 130 Irvine. CA. 92612 Richard-Polhomus, License CA -#2782 (949) 644-9370 (949) 476-14.32 FAX z a rJO M CHICTE 05/14/02 B * 01-037 w A-1 N �rV w >� 00 l V -- r--1 W iL 0 w 0.. 00 ��5 -.4� U o 0 rJO M CHICTE 05/14/02 B * 01-037 N w >� 00 r--1 w 0.. 00 ��5 -.4� U o Z rJO M CHICTE 05/14/02 B * 01-037