Loading...
HomeMy WebLinkAbout3197-1CONDUCTOR TABLE CIRCUIT OR RUNS AWG. POLE 1 2 3 4 z2x 6 4 2,k $ 9 0 MAST ARMS POLE (D1 1 1 1 1 1 1 1 1 1 PHASE 3 PHASE 4 FUTURE M PHASE 5 PHASE 6 PHASE 7 PHASE 8 u POLEo 2 1 1 1 1 1 1 1 1 C TYPE HT. SIG. LUM. H. P. S. V. TYPE PHASE QUAD VEHICLE PED, MESSAGE A B a 6A-4-80(129) 135 0 7m POLES 4151 250W 1 1 1 1 1 1 MAS,MAS,SV-1-T SP -1 -CS Sapphire Way 12' 8' F=15' a 1-A 3.054 - - B 4P N TV -1-T SP -1 -CS Q POLE 6' Q 19A-3-80(129) ' 7 5' 250W B 4P cv J POLE SP -1 -CS Beech Ave 10' 4' F=12' FOR TENON 10 4161 Q 1-A u POLEIrf - - B 5P E TV -1-T SP -1 -CS - 10' 4' a POLE Q 26A-4-80(129) 10.7m 13.71 415' 250W B 1 1 1 1 1 1 SP -1 -CS Sapphire Way 9' 5' F=17' 1-A 3.051 - B 8P _D � POLE SP -1 -CS - 10' 4' 1 1 1 1 1 1 1 1 250W B 8P S MAS, SV- 1-T SP -1 -CS Beech Ave 10' 4' F=12' FOR TENON �i 1-A3 0 TOTAL 1 1 2 2 3 3 4 4 4 4 0 0 4 3 3 2 2 1 1 #10 LUMINAIRE 2 2 2 2 - - - 2 2 - VIDEO CABLE 1 1 2 2 - 4 - 1 1 - VIDEO VIDEO SVC, 1 1 2 2 - 4 - 1 1 - DET. OPTICOM CABLE 1 1 2 2 - - 4 1 1 - CONDUIT SIZE mm 3 78 3 78 3.5 91 4 103 3.5 91 3 78 3.5 91 3 78 3 78 3 78 `FUTURE STANDARD MAST ARMS LUMINAIRE PED PUSH BT. SIGNAL MOUNTING S.N.S.* PHASE 1 PHASE 2 PHASE 3 PHASE 4 FUTURE PHASE 5 PHASE 6 PHASE 7 PHASE 8 TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 1999) 2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS. PHONE UNDERGROUND SERVICE ALERT AT (800)227-2600, TWO (2) WORKING DAYS BEFORE DIGGING. 3. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2"(53mm) RIGID METAL UNLESS UNLESS OTHERWISE SHOWN. ALL INTERCONNECT PULLBOXES SHALL BE TYPE P48 48.5" X30.5"X30" DEEP(INSIDE), PRE -CAST CONCRETE, HAVE LOCKING LIDS, AND BE LABLED "COMMUNICATIONS". 4. CONTRACTOR SHALL COORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING WITH THE SOUTHERN CALIFORNIA EDISON COMPANY WELL IN ADVANCE OF NEED, 5. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. 6. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF WORK. 7. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY SPRINKLER SYSTEMS IF NECESSARY. 8. THE ALIGNMENT OF THE INTERCONNECT DUCTS SHALL BE AS STRAIGHT AS POSSIBLE, HOWEVER, WHEN CHANGES IN ALIGNMENT ARE NECESSARY, SWEEPS SHALL HAVE RADII OF AT LEAST 10'. 9. ALL VEHICLE INDICATIONS SHALL BE 12"(300mm) AND HAVE L.E.D. SIGNAL MODULES. ALL PEDESTRIAN HEADS SHALL HAVE L.E.D. PEDESTRIAN MODULES, ALL VEHICLE, PEDESTRIAN HEADS, AND L.E.D. MODULES WILL BE FURNISHED BY THE CITY. 10. ALL UNUSED MAST ARM TENONS SHALL BE CAPPED IN A WEATHERPROOF MANNER AS DIRECTED BY THE ENGINEER. AFA File: 692.001 DEESAP.DWG 8:41 AM 12/05/02 0 11 MOUNTING DETAIL MODEL 711 OPTICAL DETECTOR Curb/Berry or edge of No u Id /P POLE SCHEDULE L STANDARD MAST ARMS LUMINAIRE PED PUSH BT. SIGNAL MOUNTING S.N.S.* PLACEMENT REMARKS 0 C TYPE HT. SIG. LUM. H. P. S. V. TYPE PHASE QUAD VEHICLE PED, MESSAGE A B a 6A-4-80(129) 135 0 7m 13 7m 4151 250W B 2P W MAS,MAS,SV-1-T SP -1 -CS Sapphire Way 12' 8' F=15' a 1-A 3.054 - - B 4P N TV -1-T SP -1 -CS - 12' 6' Q 19A-3-80(129) ' 7 5' 250W B 4P N MAS,SV-1-T SP -1 -CS Beech Ave 10' 4' F=12' FOR TENON 10 4161 Q 1-A 3.107 - - B 5P E TV -1-T SP -1 -CS - 10' 4' Q 26A-4-80(129) 10.7m 13.71 415' 250W B 6P E MAS,MAS,SV-1-T SP -1 -CS Sapphire Way 9' 5' F=17' 1-A 3.051 - B 8P S TV -1-T SP -1 -CS - 10' 4' 19A-3-80(129) 10 �m 5 415' 250W B 8P S MAS, SV- 1-T SP -1 -CS Beech Ave 10' 4' F=12' FOR TENON �i 1-A3 .05m - - - B 2P W TV -1-T 10 4' * S.N.S. SHALL BE INSTALLED ON SHAFT MOUNTED CANTILEVER MAST ARMS. SCALE 1"=20' f0 3 7 TACK 0.03' I HEADER CUT COAT ALL LIP ( 1 f 1 EDGES EXISTING e ' 30" ®¢'' AND/OR NEW MIN ° CURB AND GUTTER A.C. 10' MIN. "EXISTING A. C. SURFACE 6-1.5" SCH 40 HDPE CONDUITS AND 4 -SACK ORANGE PEA GRAVEL BACKFILL NOTE: THE SLURRY BACKFILL IS NOT REQUIRED AT DEPTHS GREATER THAN 6 FEET. DUCT INSTALLATION AND TRENCH REPAIR DETAIL N.T.S. DETAIL "C" INSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING TYPE "R" CABINET, AUTOSCOPE DETECTION, AND APPURTENANT EQUIPMENT. CONTROLLER CABINET AND FOUNDATION SHALL BE INSTALLED PER CITY STANDARD DRAWING 4004. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECT- RONIC EQUIPMENT REQUIRED TO PROVIDE THE SIGNAL OPERATION AS SHOWN ON THE PLAN. ❑2 INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND SOUTHERN CALIFORNIA EDISON COMPANY REQUIREMENTS. F3 INSTALL UNI -DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR, (MODEL 711 OR EQUAL), PER DETAIL THIS SHEET AND AS DIRECTED BY THE ENGINEER. F4 INSTALL CITY FURNISHED IMAGE SENSOR UNIT PER CITY STANDARD DRAWING 133 AND AS DIRECTED BY THE ENGINEER. FURNISH AND INSTALL SIGN AND HARDWARE PER CALTRANS DETAIL "U", ES -7N. 1-61 FURNISH AND INSTALL 6-1 .5"(41 mm) SCHEDULE 40 HDPE CONDUITS PER DETAIL "C", 3 CONDUITS SHALL BE ORANGE AND 3 CONDUITS SHALL BE BLUE. FURNISH AND INSTALL INTERCONNECT CABLE (12PR. #19) PER CALTRANS SEC. 86-2.08E AS INDICATED IN THE BLUE CONDUITS. FURNISH AND INSTALL PULL ROPE IN THE REMAINING CONDUITS FOR FUTURE CABLE. CONDUIT SWEEPS SHALL BE INSTALLED WITH A MINIMUM 10 -FOOT RADIUS. 7 CONNECT INTERCONNECT PER TRAFFIC SIGNAL CONTROLLER MANUFACTURER'S REQUIREMENTS. ❑8 CONSTRUCT 4" THICK PCG PAD ON COMPACTED NATIVE FROM AROUND PROPOSED SIGNAL AND SERVICE CABINETS. ❑g INSTALL SIGN PER DESIGNATION. SEE STATE OF CALIFORNIA, DEPARTMENT OF TRANSPORTATION, (CALTRANS) "UNIFORM SIGN CHART." 10 FURNISH AND INSTALL 3"(78mm) CONDUIT WITH 2 -INTERCONNECT CABLES (12PR. #19) 11 FURNISH AND INSTALL 3"(78mm) PVC CONDUIT WITH 1/4" POLY PULL ROPE PER SCE REQUIREMENTS. COORDINATE SERVICE WITH SCE (DAVID QUEZADA 909-357-6240 & CANERA MILES 909-357-6505).