HomeMy WebLinkAbout3197-1CONDUCTOR TABLE
CIRCUIT OR RUNS
AWG. POLE 1 2 3 4 z2x 6 4 2,k $ 9 0
MAST ARMS
POLE (D1
1
1 1
1 1
1 1
1 1
PHASE 3
PHASE 4
FUTURE
M
PHASE 5
PHASE 6
PHASE 7
PHASE 8
u
POLEo 2
1 1
1 1
1 1
1 1
C
TYPE
HT.
SIG.
LUM.
H. P. S. V.
TYPE
PHASE
QUAD
VEHICLE
PED,
MESSAGE
A
B
a
6A-4-80(129)
135
0 7m
POLES
4151
250W
1 1
1 1
1 1
MAS,MAS,SV-1-T
SP -1 -CS
Sapphire Way
12'
8'
F=15'
a
1-A
3.054
-
-
B
4P
N
TV -1-T
SP -1 -CS
Q
POLE
6'
Q
19A-3-80(129)
'
7 5'
250W
B
4P
cv J
POLE
SP -1 -CS
Beech Ave
10'
4'
F=12' FOR TENON
10
4161
Q
1-A
u
POLEIrf
-
-
B
5P
E
TV -1-T
SP -1 -CS
-
10'
4'
a
POLE Q
26A-4-80(129)
10.7m
13.71
415'
250W
B
1 1
1 1
1 1
SP -1 -CS
Sapphire Way
9'
5'
F=17'
1-A
3.051
-
B
8P
_D
�
POLE
SP -1 -CS
-
10'
4'
1
1
1
1
1
1
1
1
250W
B
8P
S
MAS, SV- 1-T
SP -1 -CS
Beech Ave
10'
4'
F=12' FOR TENON
�i
1-A3
0
TOTAL
1 1
2 2
3 3
4 4
4 4
0
0 4
3 3
2 2
1 1
#10
LUMINAIRE
2
2
2
2
-
-
-
2
2
-
VIDEO CABLE
1
1
2
2
-
4
-
1
1
-
VIDEO
VIDEO SVC,
1
1
2
2
-
4
-
1
1
-
DET.
OPTICOM CABLE
1
1
2
2
-
-
4
1
1
-
CONDUIT SIZE mm
3
78
3
78
3.5
91
4
103
3.5
91
3
78
3.5
91
3
78
3
78
3
78
`FUTURE
STANDARD
MAST ARMS
LUMINAIRE
PED PUSH BT.
SIGNAL MOUNTING
S.N.S.*
PHASE 1
PHASE 2
PHASE 3
PHASE 4
FUTURE
PHASE 5
PHASE 6
PHASE 7
PHASE 8
TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA
STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 1999)
2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR
SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS
ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS.
PHONE UNDERGROUND SERVICE ALERT AT (800)227-2600, TWO (2) WORKING DAYS
BEFORE DIGGING.
3. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2"(53mm) RIGID METAL UNLESS
UNLESS OTHERWISE SHOWN. ALL INTERCONNECT PULLBOXES SHALL BE TYPE P48 48.5"
X30.5"X30" DEEP(INSIDE), PRE -CAST CONCRETE, HAVE LOCKING LIDS, AND BE LABLED
"COMMUNICATIONS".
4. CONTRACTOR SHALL COORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING
WITH THE SOUTHERN CALIFORNIA EDISON COMPANY WELL IN ADVANCE OF NEED,
5. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT
LOCATIONS PRIOR TO FINAL PLACEMENT.
6. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF
FONTANA ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF WORK.
7. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS.
MODIFY SPRINKLER SYSTEMS IF NECESSARY.
8. THE ALIGNMENT OF THE INTERCONNECT DUCTS SHALL BE AS STRAIGHT AS POSSIBLE,
HOWEVER, WHEN CHANGES IN ALIGNMENT ARE NECESSARY, SWEEPS SHALL HAVE
RADII OF AT LEAST 10'.
9. ALL VEHICLE INDICATIONS SHALL BE 12"(300mm) AND HAVE L.E.D. SIGNAL MODULES.
ALL PEDESTRIAN HEADS SHALL HAVE L.E.D. PEDESTRIAN MODULES, ALL VEHICLE,
PEDESTRIAN HEADS, AND L.E.D. MODULES WILL BE FURNISHED BY THE CITY.
10. ALL UNUSED MAST ARM TENONS SHALL BE CAPPED IN A WEATHERPROOF MANNER AS
DIRECTED BY THE ENGINEER.
AFA File: 692.001 DEESAP.DWG 8:41 AM 12/05/02
0
11
MOUNTING DETAIL
MODEL 711 OPTICAL DETECTOR
Curb/Berry
or edge of
No
u
Id
/P
POLE SCHEDULE
L
STANDARD
MAST ARMS
LUMINAIRE
PED PUSH BT.
SIGNAL MOUNTING
S.N.S.*
PLACEMENT
REMARKS
0
C
TYPE
HT.
SIG.
LUM.
H. P. S. V.
TYPE
PHASE
QUAD
VEHICLE
PED,
MESSAGE
A
B
a
6A-4-80(129)
135
0 7m
13 7m
4151
250W
B
2P
W
MAS,MAS,SV-1-T
SP -1 -CS
Sapphire Way
12'
8'
F=15'
a
1-A
3.054
-
-
B
4P
N
TV -1-T
SP -1 -CS
-
12'
6'
Q
19A-3-80(129)
'
7 5'
250W
B
4P
N
MAS,SV-1-T
SP -1 -CS
Beech Ave
10'
4'
F=12' FOR TENON
10
4161
Q
1-A
3.107
-
-
B
5P
E
TV -1-T
SP -1 -CS
-
10'
4'
Q
26A-4-80(129)
10.7m
13.71
415'
250W
B
6P
E
MAS,MAS,SV-1-T
SP -1 -CS
Sapphire Way
9'
5'
F=17'
1-A
3.051
-
B
8P
S
TV -1-T
SP -1 -CS
-
10'
4'
19A-3-80(129)
10 �m
5
415'
250W
B
8P
S
MAS, SV- 1-T
SP -1 -CS
Beech Ave
10'
4'
F=12' FOR TENON
�i
1-A3
.05m
-
-
-
B
2P
W
TV -1-T
10
4'
* S.N.S. SHALL BE INSTALLED ON SHAFT MOUNTED CANTILEVER MAST ARMS.
SCALE 1"=20'
f0
3
7
TACK
0.03' I HEADER CUT COAT ALL
LIP ( 1 f 1 EDGES
EXISTING e '
30" ®¢''
AND/OR NEW MIN °
CURB AND
GUTTER A.C.
10' MIN. "EXISTING
A. C.
SURFACE
6-1.5" SCH 40 HDPE
CONDUITS AND 4 -SACK
ORANGE PEA GRAVEL BACKFILL
NOTE: THE SLURRY BACKFILL IS NOT REQUIRED AT DEPTHS
GREATER THAN 6 FEET.
DUCT INSTALLATION AND
TRENCH REPAIR DETAIL
N.T.S.
DETAIL "C"
INSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING
TYPE "R" CABINET, AUTOSCOPE DETECTION, AND APPURTENANT EQUIPMENT.
CONTROLLER CABINET AND FOUNDATION SHALL BE INSTALLED PER CITY STANDARD
DRAWING 4004. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECT-
RONIC EQUIPMENT REQUIRED TO PROVIDE THE SIGNAL OPERATION AS SHOWN ON
THE PLAN.
❑2 INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND
SOUTHERN CALIFORNIA EDISON COMPANY REQUIREMENTS.
F3 INSTALL UNI -DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR, (MODEL 711 OR
EQUAL), PER DETAIL THIS SHEET AND AS DIRECTED BY THE ENGINEER.
F4 INSTALL CITY FURNISHED IMAGE SENSOR UNIT PER CITY STANDARD DRAWING 133 AND
AS DIRECTED BY THE ENGINEER.
FURNISH AND INSTALL SIGN AND HARDWARE PER CALTRANS DETAIL "U", ES -7N.
1-61 FURNISH AND INSTALL 6-1 .5"(41 mm) SCHEDULE 40 HDPE CONDUITS PER DETAIL "C",
3 CONDUITS SHALL BE ORANGE AND 3 CONDUITS SHALL BE BLUE. FURNISH AND INSTALL
INTERCONNECT CABLE (12PR. #19) PER CALTRANS SEC. 86-2.08E AS INDICATED IN THE
BLUE CONDUITS. FURNISH AND INSTALL PULL ROPE IN THE REMAINING CONDUITS FOR
FUTURE CABLE. CONDUIT SWEEPS SHALL BE INSTALLED WITH A MINIMUM 10 -FOOT RADIUS.
7 CONNECT INTERCONNECT PER TRAFFIC SIGNAL CONTROLLER MANUFACTURER'S
REQUIREMENTS.
❑8 CONSTRUCT 4" THICK PCG PAD ON COMPACTED NATIVE FROM AROUND PROPOSED
SIGNAL AND SERVICE CABINETS.
❑g INSTALL SIGN PER DESIGNATION. SEE STATE OF CALIFORNIA, DEPARTMENT OF
TRANSPORTATION, (CALTRANS) "UNIFORM SIGN CHART."
10 FURNISH AND INSTALL 3"(78mm) CONDUIT WITH 2 -INTERCONNECT CABLES (12PR. #19)
11 FURNISH AND INSTALL 3"(78mm) PVC CONDUIT WITH 1/4" POLY PULL ROPE PER
SCE REQUIREMENTS. COORDINATE SERVICE WITH SCE (DAVID QUEZADA 909-357-6240 &
CANERA MILES 909-357-6505).