INTERCONNECT GENERAL NOTES:
1. TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA
STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 1999)
2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR
SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS
ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS.
PHONE UNDERGROUND SERVICE ALERT AT (800)227-2600, TWO (2)WORKING DAYS
BEFORE DIGGING.
3. ALL INTERCONNECT PULLBOXES SHALL BE 52' X 34" X 34" DEV, PREF—CAST
»
CONCRETE, HAVE LOCKING LIDS, AND LABELS CITY OF FONTANA AND COMMUNICATIONS .
4. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT
LOCATIONS PRIOR TO FINAL PLACEMENT.
5. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF
FONTANA ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF WORK.
6. THE ALIGNMENT OF THE INTERCONNECT DUCTS SHALL BE AS. STRAIGHT AS 10
RE1f11SI0
POSSIBLE, HOWEVER, WHEN CHANGES IN ALIGNMENT ARE NECESSARY,
SWEEPS SHALL HAVE RADII OF AT LEAST 10'. 1 AS 3u 1 wr"
T R A %C- T -1 -08-- 4 -1 - -1
1
I
I
I
toy
SOUTHERN CALIFORNIA
EDISON EASEMENT II
f
i fl
-�-
i i
II
26 IT
r� 25
I }:}F }
24 23 z 1 I} ►
.,► J'-' yl
2-6 PWC SLEEVES
��
N } i I
} � ISI (ll
I'I I I�I
I T CONNECTING NOTE$
I
(D—FURNISH ANO INSTALL 6-1.5" (41mm) SCHEDULE 40 HDPE CONDUITS PER DUCT INSTALLATION DETAIL, c > >
STREET
HERON, 3 CONDUITS SHALL BE ORANGE AND 3 CONDUITS SHALL BE BLUE. FURNISH AND INSTALL I }{}
INTERCONNECT CABLE (12PR. J19) PER CALTRANS STD. SPEC. 86-2.08E FROM 1IHE CONTROLLER PER TRACT 158441-1
0 CURTIS AVE. TO 114E CONTROLLER 0SIERRA LAKES PARKWAY AS INDICATED IN THE BLUE CONDUITS. IMPROVEMENT PLANS I }
FURNISH AND INSTALL PULL ROPE IN THE REMAINING CONDUITS FOR FUTURE CABLE CONDUIT SWEPS I I !
SHALL BE INSTALLED WITH A MINIMUM 100—FOOT RADIUS. CONNECT INTERCONNECT PER TRAFFIC SIGNAL ! i
CONTROLLER MANUFACTURER'S REQUIREMENTS.
—INSTALL 52' X 34' X 34' PIAL BOXES.
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
M DESCRIPIIOM DAIS OM qTY DATE:
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE WITH CONDITIONS AND
STANDARDS IN EFFECT.
EXISTING RBI I I } I
&
}I( I EXISTING SIDIMALK a
F AVE ut:
-
II
li I j II
II I it
oman, Inc.® Civil Engineering • Planning • Surveying - Public Works
No. 31681 1152 N. Mountain Ave. Ste. 100 - Upland, CA 91786-3669.909-982-7777
# Exp. 12/31/04. PREPARED LIND TH SUPERVISION OF:
7-1616 -Z-
�Of- CAI.\ -HAROLD A. GARCELON R.C.E. 31681 DATE -
o�
0
0
.a
1 40 0 40 80
scale feet
i
r
o�
a�
'Y OF FONTANA, CALIFORNIA
SUMMIT HEIGHTS 11
o�
Y
a�
MSM1 44'
8Y: AIS o
MSM TO 20041 08-21-02 7. a
RDC KEN 6
0111Y��.t�: -vrih g/3t� 0 2 i►
W 5T7 ENGINEER R.U.- 311132'
PC# 02-07-009