Loading...
HomeMy WebLinkAbout3994-2MOUNT AUTOMATIC CONTROLLER APPROVED VANDAL RESISTANT LEGEND �.: d °. • ON MOUNTING BRACKETS INSIDE CONTROLLER ENCLOSURE SHRUB SPRAY / BUBBLE HEAD. 6' APPROVED PROTECTIVE ENCLOSURESTRONG BOX SB-24SS - u NDISTURBED SOIL II! 2" TO 2 112" IN SIZE12" RAIN GUARD ` NOTE, INSTALL BACKFLOW PREVENTER AS RECO. BY LOCAL CODES 0 • ° 4 CONCRETE FOOTING: INSTALL 3" AND HEALTH DEPT. VERIFY LOCAL REQS. PRIOR TO INSTALLATION, • EXISTING SOIL I MINIMUM ABOVE GRADE AND SLOPE PVC SCH. 80 NIPPLE. t 8 3 CONCRETE AT 2% TO DRAIN 8' VANDAL PROOF ENCLOSURE _. 1( 5. PVC TxT 90 DEG. ELL. SIZE TO FIT • • 0 :..r;..- .- ..:, :�.'.. 6. REDUCED PRESSURE •. 1111 G LATERAL LINE FITTING. BACKFLOW PREVENTER BRASS NIPPLES (4" MIN. 2 8. REMOTE CONTROL VALVE WIRES: BALL VALVE LENGTH) VERIFY W/ 4 III AWG OF J14 SECURE WIRES TO (2) TOTAL LOCAL CODES 12' ON-OFF SWITCH FINISH GRADE CONTROL UNIT AT TERMINALS PROVIDED IN CONTROL UNT, EXTEND ONE COMMON WIRE TO BRASS "Y STRAINER I 5 TORO ALL R.C.V.'S AND ONE CONTROL / BRASS 90 ELL (TYP.) L LINES LATERA 8" MIN. WIRE TO EACH R.C.V. (TYPICAL) 60 MESH 00 �IIIIIlII---, COMMON WIRE SHALL BE TIED MONEL SCREEN 1 °N .• ••��•'• 3 tN SCH. 40 SLEEVE INSIDE PROTECTIVE ENCLOSURE & BRASS LUG RASS UNION (TYP.) 570 Z-PRX- I2P-COM-15Q QUARTER SPRAY HEAD WHEN REQUIRED. J1 30 . IIlIlI �. TORO 10. QUICK COUPLING VALVE. p , ' • .d ':. • � • 6" MINI. I ll CURB • • • � ° • ' � • � I1I -•�1 4" CONCRETE PAD . 3.60 �II�IIIII FG STREET I -IiII -II4I I I_ IN SCH. 40 SLEEVE IlIll{!-��II PRESSURE MAINLINE, SEE . . TC CITY WATER MAIN 1/2" BY 5 -FOOT MIN. ' A `' --� COPPER GROUND ROD. STAINLESS STEEL BANDS * 1III FLOW CONDUIT AND IRRIGATION ELECTRICAL CONDUIT TO SOURCE INTERCONNECT WHEN REQUIRED CONTROL UNIT REQUIREMENTS PVC SWEEP ELBOW 120 V., 60 Hz, 2 AMP. MAX. SIZE A5 REQUIRED NOTES: 1. COMMON WIRE TO BE WHITE AND CONTROL WIRES TO BE COLOR CODED. 2. No SPLICES SHALL BE MADE BETWEEN CONTROLLER AND R.C.V.. 3. ALL WIRING . CONDUIT OR PLUMBING TO GO THROUGH BOTTOM OF CONCRETE FOOTING. 4. AFTER ESTABLISHMENT OF ALL PLANT MATERIAL %CONTROL.LER SHALL BE PROGRAMMED TO IRRIGATE SOLELY DURING NIGHTTIME (TYPICAL) AUTOMATIC CONTROLLER I��II '. '. . • I�IIIIII ' f :�,• � Illl�ll ` •� • � �IIIIIII llll�ll ` 4*04. ." III�II i2 X12 Xi2" CONCRETE-,,--' FROM P.O.C. THRUST BLOCK PVC MAINLINE USE TEFLON TAPE OR TEFLON PIPE DOPE ON ALL PVC TO PVC OR METAL TO PVC MALE PIPE THREADS REDUCED PRESSURE B. F. NOTE: DRAINAGE OF IRRIGATION WATER THROUGH SPRINKLER HEAD WILL NOT BE ALLOWED. SOME SPRINKLER HEADS WILL REQUIRE THE INSTALLATION OF AN ANTI -DRAIN VALVE IN THE RISER NIPPLE TO PREVENT DRAINAGE. DURING THE COURSE OF CONSTRUCTION THE CONTRACTOR SHALL INSTALL AN ANTI -DRAIN VALVE AS REQ'D. AT ANY SPRINKLER HEAD SHOWING SIGNS OF DRAINING AFTER THE IRRIGATION SYSTEM HAS OPERATED FROM AN ON TO OFF POSITION. INSTALLATION OF ANTI -DRAIN VALVES SHALL BE INCLUDED IN THE BID PRICE WITHOUT ADDITIONAL COST TO THE OWNER. SPRAY HEAD ON RISER iL 0 a � I z- 0 a REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTION ASSEMBLY MIN. 18" CLF. MAX 36" CLR. III " _I I�IIIII i � • NOTES 1. REDUCED PRESSURE BACKFLOW PREVENTION ASSEMBLIES MUST BE CONNECTED TO CITY WATER AND TESTED PRIOR TO BEING PLACED INTO SERVICE. 2. POINT OF SERVICE: A.POINT OF SERVICE IS THE BACK OF CURB FOR ALL CITY STREETS WITH PLANTER STRIPS. B. POINT OF SERVICE IS THE BACK OF SIDEWALK FOR STREETS WITH SIDEWALK CONTIGUOUS WITH CURB AND GUTTER. C.POINT OF SERVICE THE RIGHT-OF-WAY LINE ON ALL ALLEYS AND UNIMPROVED STREETS. D. WHERE THE POINT OF SERVICE IS UNCLEAR THE LOCATION SHALL BE DETERMINED BY THE CROSS CONNECTION CONTROL SPECIALIST OR HIS DESIGNEE. 3, LIST OF APPROVED BACKFLOW PREVENTION ASSEMBLIES AND CERTIFIED BACKFLOW PREVENTION ASSEMBLY TESTERS ARE AVAILABLE AT THE DEPARTMENT OF UTILITIES CUSTOMER SERVICE COUNTER. 4. THE BACKFLOW PREVENTION ASSEMBLIES SHALL BE INSTALLED ABOVE GROUND. IN A HORIZONTAL AND LEVEL POSITION. THE ASSEMBLY SHALL BE LOCATED ON THE CUSTOMER'S SIDE AND NO FURTHER THAN FIVE (5) FEET FROM THE POINT OF SERVICE OR THE METER. 5. NO OUTLET, TAP, TEE, OR CONNECTION BETWEEN THE WATER MAIN AND BACKFLOW PREVENTER IS ALLOWED UNLESS APPROVED BY THE DEPARTMENT OF UTILITIES. 6. CONCRETE PAD IS RECOMMENDED IF ASSEMBLY IS PLACED WITHIN A PROTECTIVE ENCLOSURE. FLOW 7, FREEZE BAGS ARE RECOMMENDED FOR FREEZE PROTECTION. (IF APPLICABLE) 8. BACKFLOW SHALL BE WRAPPED WITH THERMAL "POLAR BARRIER R-19" INSTALL PER MFG. SPECS. (909) 587-2230 COPPER TUBING TYPE L 9. BACKFLOW TO BE MOUNTED ON A CONCRETE PAD AND SHALL BE ENCLOSED IN A COMPOSITE FIBERGLASS BOX MANUFACTURED BY WINTER BOX (800) 942-4705, WITH LOCKING CAPABILITIES NOTES: RA PR T 5T T 0 F VE INSTALLATION OF 2 INCH AND SMALLER REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTION ASSEMBLY W/ WATER METER APPROVED VALVE BOX SIZE AS REQUIRED BRASS OR COPPER NIPPLE & UNION PVC MALE ADAPTER TYP. 2 (TWO) PLACES FINISH GRADE 12" MAX. MASTER VALVE VALVE noaan►�cn lun�-coo�nn� ►. rv.v. v.vv..r. 1" IN TURF AREAS 2" IN SHRUB AREAS hill REDUCED PRESSURE B.F. 2 1 1. SLIP BASE SOCKET OVER ENDS OF WIRES, 6T�P 1 2. STRIP WIRES APPROX. 5/8" FROM ENDS - TWIST TOGETHER. q 3 3. PUT CRIMP SLEEVE OVER WIRE ENDS - CRIMP AND CUT OFF EXCESS WIRE. s3T#=P 3 4. APPLY SEALER TO OUTSIDE OF SEALING - PLUG FILL CAVITY WITH SEALER. 5. PULL BASE SOCKET OVER CRIMPED CON - 6 5 VECTION AS FAR AS POSSIBLE. STEP 3 6. PUSH SEALING PLUG INTO BASE SOCKET. 7. PUSH WIRES TO END OF BASE SOCKET TO ASSURE COMPLETE SEALING OF CONNECTION. 8. RAIN BIRD "SNAP -TITS" WIRE CONNECTOR 6TrmP .4 OR APPROVED EQUAL. WIRE CONNECTOR A LEGEND �.: d °. • E 1. SHRUB SPRAY / BUBBLE HEAD. 6' 18" 30" - u NDISTURBED SOIL II! 2" TO 2 112" IN SIZE12" 1 2. ANTI -DRAIN VALVE. (SEE NOTE BLOW). 0 • ° 4 3. FINISH GRADE. 24" • EXISTING SOIL I 4. PVC SCH. 80 NIPPLE. t 8 3 CLEAN COMPACTED BACKFILL 8' I _. 1( 5. PVC TxT 90 DEG. ELL. ,:- � _-' :;-. • • 0 :..r;..- .- ..:, :�.'.. 6. MARLEX TxT 90 DEC. STREET ELL. •. 1111 7. LATERAL LINE FITTING. 120 VOLT ELECTRICAL °• o '• 0 0 2 8. WALL OR FENCE. 30 •• � ° 4 III 12" ABOVE F.G. FOR SHRUB SPRAY IN SCH. 40 SLEEVE120 _ 12' .50 HEADS, 3" ABOVE F.G. FOR BUBBLER I 5 TORO HEADS AND 6" ABOVE F.G. FOR L LINES LATERA IJI STREAM BUBBLERS. NOTE: DRAINAGE OF IRRIGATION WATER THROUGH SPRINKLER HEAD WILL NOT BE ALLOWED. SOME SPRINKLER HEADS WILL REQUIRE THE INSTALLATION OF AN ANTI -DRAIN VALVE IN THE RISER NIPPLE TO PREVENT DRAINAGE. DURING THE COURSE OF CONSTRUCTION THE CONTRACTOR SHALL INSTALL AN ANTI -DRAIN VALVE AS REQ'D. AT ANY SPRINKLER HEAD SHOWING SIGNS OF DRAINING AFTER THE IRRIGATION SYSTEM HAS OPERATED FROM AN ON TO OFF POSITION. INSTALLATION OF ANTI -DRAIN VALVES SHALL BE INCLUDED IN THE BID PRICE WITHOUT ADDITIONAL COST TO THE OWNER. SPRAY HEAD ON RISER iL 0 a � I z- 0 a REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTION ASSEMBLY MIN. 18" CLF. MAX 36" CLR. III " _I I�IIIII i � • NOTES 1. REDUCED PRESSURE BACKFLOW PREVENTION ASSEMBLIES MUST BE CONNECTED TO CITY WATER AND TESTED PRIOR TO BEING PLACED INTO SERVICE. 2. POINT OF SERVICE: A.POINT OF SERVICE IS THE BACK OF CURB FOR ALL CITY STREETS WITH PLANTER STRIPS. B. POINT OF SERVICE IS THE BACK OF SIDEWALK FOR STREETS WITH SIDEWALK CONTIGUOUS WITH CURB AND GUTTER. C.POINT OF SERVICE THE RIGHT-OF-WAY LINE ON ALL ALLEYS AND UNIMPROVED STREETS. D. WHERE THE POINT OF SERVICE IS UNCLEAR THE LOCATION SHALL BE DETERMINED BY THE CROSS CONNECTION CONTROL SPECIALIST OR HIS DESIGNEE. 3, LIST OF APPROVED BACKFLOW PREVENTION ASSEMBLIES AND CERTIFIED BACKFLOW PREVENTION ASSEMBLY TESTERS ARE AVAILABLE AT THE DEPARTMENT OF UTILITIES CUSTOMER SERVICE COUNTER. 4. THE BACKFLOW PREVENTION ASSEMBLIES SHALL BE INSTALLED ABOVE GROUND. IN A HORIZONTAL AND LEVEL POSITION. THE ASSEMBLY SHALL BE LOCATED ON THE CUSTOMER'S SIDE AND NO FURTHER THAN FIVE (5) FEET FROM THE POINT OF SERVICE OR THE METER. 5. NO OUTLET, TAP, TEE, OR CONNECTION BETWEEN THE WATER MAIN AND BACKFLOW PREVENTER IS ALLOWED UNLESS APPROVED BY THE DEPARTMENT OF UTILITIES. 6. CONCRETE PAD IS RECOMMENDED IF ASSEMBLY IS PLACED WITHIN A PROTECTIVE ENCLOSURE. FLOW 7, FREEZE BAGS ARE RECOMMENDED FOR FREEZE PROTECTION. (IF APPLICABLE) 8. BACKFLOW SHALL BE WRAPPED WITH THERMAL "POLAR BARRIER R-19" INSTALL PER MFG. SPECS. (909) 587-2230 COPPER TUBING TYPE L 9. BACKFLOW TO BE MOUNTED ON A CONCRETE PAD AND SHALL BE ENCLOSED IN A COMPOSITE FIBERGLASS BOX MANUFACTURED BY WINTER BOX (800) 942-4705, WITH LOCKING CAPABILITIES NOTES: RA PR T 5T T 0 F VE INSTALLATION OF 2 INCH AND SMALLER REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTION ASSEMBLY W/ WATER METER APPROVED VALVE BOX SIZE AS REQUIRED BRASS OR COPPER NIPPLE & UNION PVC MALE ADAPTER TYP. 2 (TWO) PLACES FINISH GRADE 12" MAX. MASTER VALVE VALVE noaan►�cn lun�-coo�nn� ►. rv.v. v.vv..r. 1" IN TURF AREAS 2" IN SHRUB AREAS hill REDUCED PRESSURE B.F. 2 1 1. SLIP BASE SOCKET OVER ENDS OF WIRES, 6T�P 1 2. STRIP WIRES APPROX. 5/8" FROM ENDS - TWIST TOGETHER. q 3 3. PUT CRIMP SLEEVE OVER WIRE ENDS - CRIMP AND CUT OFF EXCESS WIRE. s3T#=P 3 4. APPLY SEALER TO OUTSIDE OF SEALING - PLUG FILL CAVITY WITH SEALER. 5. PULL BASE SOCKET OVER CRIMPED CON - 6 5 VECTION AS FAR AS POSSIBLE. STEP 3 6. PUSH SEALING PLUG INTO BASE SOCKET. 7. PUSH WIRES TO END OF BASE SOCKET TO ASSURE COMPLETE SEALING OF CONNECTION. 8. RAIN BIRD "SNAP -TITS" WIRE CONNECTOR 6TrmP .4 OR APPROVED EQUAL. WIRE CONNECTOR DIMENSION A B �.: d PAVING OR D.G. PATH E FINISHED GRADE 112" TO 1 112" SIZE IT - 18" 30" - u NDISTURBED SOIL II! 2" TO 2 112" IN SIZE12" D A � I II SAND BACKFILL COMPACTED TO THE DENSITY OF I II 6" 6" =III I!l 24" 24" EXISTING SOIL I - l l 1- fi" t - 4. CLEAN COMPACTED BACKFILL 8' I _. 1( - I BRASS 90 DEG. ELL. ,:- � _-' :;-. --�,•---4._�- :..r;..- .- ..:, :�.'.. - -VOLT ELECTRICAL III 6. COMMON BRIC1< (2 REQUIRED). .. ........ .... .... I III 120 VOLT ELECTRICAL MAINLINE PIPING. _ 4 ..; - 1.0 30 IN SCH. 40 CONDUIT -III III .- ...- .- .- . .--. III II IN SCH. 40 SLEEVE120 _ 12' .50 7. MAINLINE FITTING. I LATERAL LINES, SEE SPECS. TORO IIIIII .. L LINES LATERA IJI 8. 2" CLEARANCE. 00 �IIIIIlII---, FULL SPRAY HEAD %. • �'°6' 1 °N .• ••��•'• 3 tN SCH. 40 SLEEVE BRASS NIPPLE - 6" LONG, 570 Z-PRX- I2P-COM-15Q QUARTER SPRAY HEAD CLEAN SAND BACKFILL, : 30 . IIlIlI IIII L UNDISTURBED SOI Ii TORO 10. QUICK COUPLING VALVE. I II SPECIFICATIONS I ll .... . . .SEE . .. . d CONTROL WIRES I1I -•�1 � -- ...-. . 3.60 �II�IIIII IIllIIlI�.-. .....-...... I -IiII -II4I I I_ IN SCH. 40 SLEEVE IlIll{!-��II PRESSURE MAINLINE, SEE . . - ' •.........,..t-... -CONTROL SPECIFICATIONS REQUIRE A RMNBIRD SPX -100 FLEXIBLE JOINT ASSEMBLY. STAINLESS STEEL BANDS ................... � 1III E. PRESSURE MAINLN .;.... . . III WIRES, SEE SPECS. NOTES: 1. LOCATE HEADS 5" FROM SIDE WALK, CURB ETC. ib . ... E E�E E.. : II1=1 I I-- IN SCH. 40 SLEEVE GALLONS PER MINUTE IS NOT AVAILABLE. 1=1 INSTALL AT MAINLINE DEPTH 4. WHERE NOTED CHECK VALVE SHALL BE INSTALLED UNDER HEAD 2" IN SHRUB AREAS. USING SCHEDULE 80 NIPPLE. UNDER PAVING SHALL BE SCH 40 PVC AND INSTALLED 24" DEEP. III QUICK III PVC SLEEVES TO BE JI JI :III lII III -III- CONTACT THE CONTRACTING OFFICER PRIOR TO ANY MAJOR CHANGE(S) fI I III SII IIS IIS= TWICETHEDIAMETER PIPE INSTALLATION: :ll III -Ifni OF THE PIPE OR WIRE �- 12" LATERAL LINES BURIED PER SPECIFICATIONS: SECTION VIEW - N.T.S. BUNDLE CARRIED. SECTION VIEW - N.T.S. * ALL LINES LOCATED WITHIN RIGHT-OF-WAY. 1. 10" DIAMETER CIRCULAR VALVE BOX. * ALL LINES LOCATED ADJACENT TO CURB OR SIDEWALK. DIMENSION A B C D E F 112" TO 1 112" SIZE IT 18" 18" 30" 6" 8" 2" TO 2 112" IN SIZE12" PLAN 24" 24" 30" 6" 6" 3" AND LARGER 18" 24" 24" 14 MIS' 6" fi" DIMENSION A B C D E DEPTH BELOW GRADE 24" 36" 36" 36" 6" III:..:..::11= I PVC SC. 40 TIE A 36" LOOP IN ALL WIRING AT I I STREET ELBOW CHANGES OF DIRECTION GREATER THAN I 30 DEGREES, UNTIE AFTER ALL CONECTIONS I HAVE BEEN MADE. PLAN VIEW - N.T.S. NOTE: ALL PVC MAINLINE, PVC LATERAL LINES, AND CONTROL_ WIRES SHALL BE SLEEVED NOTE: BELOW ALL HARDSCAPE ELEMENTS WITH SCH. 40 PVC, 2 TIMES THE DIAMETER OF ALL PLASTIC PIPING SHALL BE SNAKED WITHIN TRENCH. THE PIPE OR WIRE BUNDLE WITHIN. BUNDLE WIRING AND WRAP WITH TAPE AT TEN FOOT INTERVALS. ALL CURBS SHALL BE MARKED WITH A "SCORE" MARK TO DESIGNATE SLEEVE LOCATION. ALL MAINLINE PIPING TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS SLEEVE DETAIL SHALL ALSO BE USED FOR INSTALLATION OF PIPE IN ROCK SOIL. INSTALLATION SPECIFICATIONS. 6ECT101�1 LEGEND FINISH GRADE POP-UP HEAD CURB OR WALK L IR" MIItI.�-- PVC SCH. 80 NIPPLE, SIZE 120 MM, AND LENGTH AS REQUIRED TYPICAL TWO PLACES LATERAL LINE. SIZE PER DRAWINGS TYPICAL TRENCHING SECTION TYPICAL SLEEVING LEGEND 1. ELECTRIC CONTROL VALVE. 2. RECTANGULAR VALVE BOX W/GREEN BOLT DOWN COVER. HEAT BRAND VALVE STATION NO. ON LID IN 2" HIGH CHARACTERS. 3. CHRISTY'S 1,D.TAG - NUMBERED TO MATCH DRAWINGS. 4. FINISH GRADE. 5. PVC. MALE ADAPTER (TYP.) 6. PVC PIPE TO SPRINKLERS - ANGLE PIPE TO SPECIFIED DEPTH WITH 45 DEC. ELLS. 7. COMMON BRICK (4 REQUIRED). 8. COMMON WIRE TO OTHER VALVES ON SAME CONTROLLER. 9. 3/4" CRUSHED ROCK. 8" DEEP. 10. CONTROL/COMMON WIRES FROM CONTROLLER. 11. PVC SCHEDULE 40 PIPE. 12. PVC SxS 90 DEG. ELL. 13. WATER PROOF WIRE CONNECTOR. (SEE DETAIL 6) 14. MAIN LINE FITTING W/SOLVENT WELD OUTLET. 15. COIL WIRES PER SPECIFICATIONS. REMOTE CONTROL VALVE WATERPROOF ALL WIRE CONNECTIONS AS PER STD. RED YELLOW PVC TEE (SXSXT) OR ELBOW PVC SCH. 40 ELBOW PVC SC. 40 STREET ELBOW NOTES: 1. LOCATE HEADS 6" FROM SIDE WALK, CURB ETC. 2. INSTALL HEADS FLUSH WITH TOP OF HARDSCAPE AT INTERSECTIONS AND CORNERS. 3. USE TEFLON TAPE ON ALL MALE THREADED FITTINGS EXCEPT HEAD. 4. WHERE NOTED CHECK VALVE SHALL BE INSTALLED UNDER HEAD USING SCHEDULE 80 NIPPLE. OF 14 WHITE W/STRIPE WIRES (COMMON) BLUE i FLOW SENSOR DIAMETER SAME SIZE AS FLOW METER SIZE MINIMUM DISTANCE UPSTREAM 1OX DIAMETER OF FLOW METER SIZE POP-UP SPRINKLER HEAD MASTER CONTROL VALVE MINIMUM DISTANCE DOWNSTREAM 5X DIAMETER OF FLOW METER SIZE FLOW METER Q o 4S0 'o 0 . . a O 00 ,0 9 OO Q°S°90•( ogO 1 o a o ° 009 APPROVED 0 o a 1. PLACE PEA G VEL I0R 0 IN ALLA i N 0 VAL BOX. 2. PLACE BOXES AT RIGHT ANGLES TO HARDSCAPE OR STRUCTURES. 3. PIPE UPSTREAM OF VALVE ASSEMBLY IS EQUAL IN DIAMETER TO DOWNSTREAM PIPING OF VALVE ASSEMBLY. IF NECESSARY, ADD REDUCE -BUSHING TO BRING PIPING DIAMETER TO VALVE SIZE 4. MASTER VALVES 4" AND LARGER TO BE PROVIDED WITH FLANGED CONNECTIONS IN LIEU OF UNIONS. IRRIGATION MASTER VALVE ROUND VALVE BOX WITH GREEN BOLT - DOWN COVER - HEAT BRAND "GV" ON VALVE BOX COVER IN 2" HIGH LETTERS. 2. "^'s" °re"°E � IRRIGATION LEGEND 3. GATE VALVE WITH BRONZE WHEELHANDLE OR CROSSHANDLE. !]IACi '1'1C: PLAN: SYMBOL MFG. 1. 10" ROUND VALVE BOX WITH GREEN BOLT - RAD. GPM PSI 4. 6" DIA. SCH. 40 PVC PIPE EXTENSION - DOWN COVER - HEAT BRAND "QCV" ON l] 1 570 Z-PRX-12P-COM-5Q QUARTER SPRAY HEAD VALVE BOX COVER IN 2" HIGH LETTERS. PLAN ��ir LENGTH AS REQUIRED. 2. FINISH GRADE. 12" MAx 570 Z-PRX-12P-COM-5H HALF SPRAY HEAD 3. 3/4" CRUSHED ROCK. 6" DEPTH. 14 MIS' 5. 3/4" CRUSHED ROCK - 8" DEPTH. E t Z 4. BRASS NIPPLE. (LENGTH AS REQUIRED). 8' .25 30 5. BRASS 90 DEG. ELL. TORO 570 Z-PRX-12P-COM-8H HALF SPRAY HEAD 8' .50 30 6. COMMON BRIC1< (2 REQUIRED). 6. MAINLINE PIPING. a - 1.0 30 7. PVC MALE ADAPTER (TYPICAL). TCLUDE E SELECTING THE BEST ROADWAYS AS AS POSSIBLE THIS SHALL IN TORO It QUARTER SPRAY HEAD 12' .50 7. MAINLINE FITTING. 13 TORO Im HALF SPRAY HEAD 12' Y ><u 30 8. 2" CLEARANCE. 00 8. BRASS 90 DEG. STREET ELL. FULL SPRAY HEAD %. • �'°6' 1 °N .• ••��•'• 3 9. BRASS NIPPLE - 6" LONG, TORO 570 Z-PRX- I2P-COM-15Q QUARTER SPRAY HEAD 15 .85 30 LATERAL LINE, SIZE PER O TORO 10. QUICK COUPLING VALVE. i 5' 1.65 30 * 1" IN TURF AREAS. d TORO 570 Z-PRX-12P-COM-15F FULL SPRAY HEAD 15' 3.60 30 11. WALK OR CURB. 8 REVISIONS REQUIRED. SWING JOINTS: 12. 24" #3 REBAR W/ 2 ' PVC TEE (SXSXT) AS PER DETAIL. SPRAY OR ROTOR HEADS WITHIN THE TURF BLOCK AREA WILL IZ REQUIRE A RMNBIRD SPX -100 FLEXIBLE JOINT ASSEMBLY. STAINLESS STEEL BANDS PVC sc. STREET ELBOW MINIMUM PRESSURE AND MAXIMUM GALLONS REQUIRED PVC SCH. 40 ELBOW 13. BRICK SUPPORT (3 REQ.) AND A MAXIMUM DEMAND AT THE POINT OF CONNECTION, AS NOTED ON THE PLAN, NOTES: 1. LOCATE HEADS 5" FROM SIDE WALK, CURB ETC. ib 2. INSTALL HEADS FLUSH WITH TOP OF HARDSCAPE AT INTERSECTIONS * 1" IN LAWN AREAS. GALLONS PER MINUTE IS NOT AVAILABLE. 3. USE TEFLON TAPE ON ALL MALE THREADED FITTINGS EXCEPT HEAD. 4. WHERE NOTED CHECK VALVE SHALL BE INSTALLED UNDER HEAD 2" IN SHRUB AREAS. USING SCHEDULE 80 NIPPLE. NOTE: USE TEFLON TAPE ON ALL MALE PIPE UNDER PAVING SHALL BE SCH 40 PVC AND INSTALLED 24" DEEP. THREADS. QUICK COUPLING VALVE FINISH GRADE POP-UP HEAD CURB OR WALK L IR" MIItI.�-- PVC SCH. 80 NIPPLE, SIZE 120 MM, AND LENGTH AS REQUIRED TYPICAL TWO PLACES LATERAL LINE. SIZE PER DRAWINGS TYPICAL TRENCHING SECTION TYPICAL SLEEVING LEGEND 1. ELECTRIC CONTROL VALVE. 2. RECTANGULAR VALVE BOX W/GREEN BOLT DOWN COVER. HEAT BRAND VALVE STATION NO. ON LID IN 2" HIGH CHARACTERS. 3. CHRISTY'S 1,D.TAG - NUMBERED TO MATCH DRAWINGS. 4. FINISH GRADE. 5. PVC. MALE ADAPTER (TYP.) 6. PVC PIPE TO SPRINKLERS - ANGLE PIPE TO SPECIFIED DEPTH WITH 45 DEC. ELLS. 7. COMMON BRICK (4 REQUIRED). 8. COMMON WIRE TO OTHER VALVES ON SAME CONTROLLER. 9. 3/4" CRUSHED ROCK. 8" DEEP. 10. CONTROL/COMMON WIRES FROM CONTROLLER. 11. PVC SCHEDULE 40 PIPE. 12. PVC SxS 90 DEG. ELL. 13. WATER PROOF WIRE CONNECTOR. (SEE DETAIL 6) 14. MAIN LINE FITTING W/SOLVENT WELD OUTLET. 15. COIL WIRES PER SPECIFICATIONS. REMOTE CONTROL VALVE WATERPROOF ALL WIRE CONNECTIONS AS PER STD. RED YELLOW PVC TEE (SXSXT) OR ELBOW PVC SCH. 40 ELBOW PVC SC. 40 STREET ELBOW NOTES: 1. LOCATE HEADS 6" FROM SIDE WALK, CURB ETC. 2. INSTALL HEADS FLUSH WITH TOP OF HARDSCAPE AT INTERSECTIONS AND CORNERS. 3. USE TEFLON TAPE ON ALL MALE THREADED FITTINGS EXCEPT HEAD. 4. WHERE NOTED CHECK VALVE SHALL BE INSTALLED UNDER HEAD USING SCHEDULE 80 NIPPLE. OF 14 WHITE W/STRIPE WIRES (COMMON) BLUE i FLOW SENSOR DIAMETER SAME SIZE AS FLOW METER SIZE MINIMUM DISTANCE UPSTREAM 1OX DIAMETER OF FLOW METER SIZE POP-UP SPRINKLER HEAD MASTER CONTROL VALVE MINIMUM DISTANCE DOWNSTREAM 5X DIAMETER OF FLOW METER SIZE FLOW METER Q o 4S0 'o 0 . . a O 00 ,0 9 OO Q°S°90•( ogO 1 o a o ° 009 APPROVED 0 o a 1. PLACE PEA G VEL I0R 0 IN ALLA i N 0 VAL BOX. 2. PLACE BOXES AT RIGHT ANGLES TO HARDSCAPE OR STRUCTURES. 3. PIPE UPSTREAM OF VALVE ASSEMBLY IS EQUAL IN DIAMETER TO DOWNSTREAM PIPING OF VALVE ASSEMBLY. IF NECESSARY, ADD REDUCE -BUSHING TO BRING PIPING DIAMETER TO VALVE SIZE 4. MASTER VALVES 4" AND LARGER TO BE PROVIDED WITH FLANGED CONNECTIONS IN LIEU OF UNIONS. IRRIGATION MASTER VALVE ROUND VALVE BOX WITH GREEN BOLT - DOWN COVER - HEAT BRAND "GV" ON VALVE BOX COVER IN 2" HIGH LETTERS. 2. "^'s" °re"°E � IRRIGATION LEGEND 3. GATE VALVE WITH BRONZE WHEELHANDLE OR CROSSHANDLE. !]IACi '1'1C: PLAN: SYMBOL MFG. MODEL NO. DESCRIPTON RAD. GPM PSI 4. 6" DIA. SCH. 40 PVC PIPE EXTENSION - AREAS ARE FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED IN l] TORO 570 Z-PRX-12P-COM-5Q QUARTER SPRAY HEAD 5' .10 30 LENGTH AS REQUIRED. Q ❑ TORO 570 Z-PRX-12P-COM-5H HALF SPRAY HEAD 5' .20 30 5. 3/4" CRUSHED ROCK - 8" DEPTH. 8d 46 TORO 570 Z-PRX-12P-COM-8Q QUARTER SPRAY HEAD 8' .25 30 TORO 570 Z-PRX-12P-COM-8H HALF SPRAY HEAD 8' .50 30 6. COMMON BRIC1< (2 REQUIRED). TORO 570 Z-PRX-I2P-COM-8F FULL SPRAY HEAD 81 1.0 30 7. PVC MALE ADAPTER (TYPICAL). TCLUDE E SELECTING THE BEST ROADWAYS AS AS POSSIBLE THIS SHALL IN TORO 570 Z-PRX-12P-COM-12Q QUARTER SPRAY HEAD 12' .50 30 13 TORO 570 Z-PRX-I2P-COM-12H HALF SPRAY HEAD 12' 1.09 30 8. 2" CLEARANCE. 00 TORO 570 Z-PRX-12P-COM-12F FULL SPRAY HEAD 12' 2.19 30 9. PVC MAIN LINE PIPE. TORO 570 Z-PRX- I2P-COM-15Q QUARTER SPRAY HEAD 15 .85 30 LATERAL LINE, SIZE PER O TORO 570 Z-PRX- I2P-COM-15H HALF SPRAY HEAD i 5' 1.65 30 * 1" IN TURF AREAS. d TORO 570 Z-PRX-12P-COM-15F FULL SPRAY HEAD 15' 3.60 30 2" IN SHRUB AREAS. REVISIONS REQUIRED. ° 00 °41 - Tj 1, ° B 1080 - 0. SE �aa p 80 '8 000.8$ °o .°°- o0 Q. ° foo 80 1 o7�IG'Lv�U�1 N •a•o° 8°0 1 a g0. 0Yo 0 0 5 GATE VALVE 11RIDNIGATION NOTES HIGH POP-UP HEAD !]IACi '1'1C: PLAN: FINISH GRADE CURB OR WALK THIS SYSTEM IS DIAGRAMMATIC. ALL PIPE, VALVES, ETC. SHOWN WITHIN PAVED �A AREAS ARE FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED IN H I` MILL 1 Imo' M a PLANTING AREAS AND JOINT TRENCHES WHEREVER POSSIBLE. Q W SPRINKLER ADJUSTMENT REQUIRED: 8d Z �" w THE IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLER HEADS C) FOR OPTIMUM PERFORMANCE AND PREVENT OVERSPRAY ONTO WALKS AND Tm TCLUDE E SELECTING THE BEST ROADWAYS AS AS POSSIBLE THIS SHALL IN DEGREE OF ARC FIT THE EXISTING SITE CONDITIONS. CONTRACTOR TO USE PRESSURE COMPENSATING SCREENS WHEN RADIUS IS REDUCED MORE THAN FIFTY PERCENT (50%). INSTALL NECESSARY CHECK VALVE IN HEADS THAT EXHIBIT TENDENCIES FOR LOW HEAD DRAINAGE. 12" MIN. FIELD CONDITIONS: DO NOT WILLFULLY INSTALL THE SPRINKLER SYSTEM AS INDICATED ON THE LATERAL LINE, SIZE PER DRAWINGS WHEN IT IS OBVIOUS IN THE FIELD THAT UNKNOWN OBSTRUCTIONS OR DRAWINGS PVC SCH. 80 NIPPLE, SIZE GRADE DIFFERENCES EXIST AND SHOULD BE BROUGHT TO THE ATTENTION OF THE AND LENGTH AS REQUIRED CONTRACTING OFFICER. IN THE EVENT THAT THIS NOTIFICATION IS TYPICAL TWO PLACES NOT PERFORMED, THE CONTRACTOR MUST ASSUME FULL RESPONSIBILITY FOR ANY REVISIONS REQUIRED. SWING JOINTS: INSTALL ALL HEADS WITH DOUBLE OR TRIPLE SWING JOINTS, USING STREET ELLS, PVC TEE (SXSXT) AS PER DETAIL. SPRAY OR ROTOR HEADS WITHIN THE TURF BLOCK AREA WILL PVC SC. 40 OR ELBOW REQUIRE A RMNBIRD SPX -100 FLEXIBLE JOINT ASSEMBLY. STREET ELBOW PVC sc. STREET ELBOW MINIMUM PRESSURE AND MAXIMUM GALLONS REQUIRED PVC SCH. 40 ELBOW THE SPRINKLER SYSTEM DESIGN IS BASED ON A MINIMUM OPERATIONAL PRESSURE AND A MAXIMUM DEMAND AT THE POINT OF CONNECTION, AS NOTED ON THE PLAN, NOTES: 1. LOCATE HEADS 5" FROM SIDE WALK, CURB ETC. BEFORE INSTALLING THE SYSTEM, CHECK POINT OF CONNECTION AND IMMEDIATELY 2. INSTALL HEADS FLUSH WITH TOP OF HARDSCAPE AT INTERSECTIONS NOTIFY CONTRACTING OFFICER IF PRESSURE IS NOT AS NOTED OR THE REQUIRED AND CORNERS. GALLONS PER MINUTE IS NOT AVAILABLE. 3. USE TEFLON TAPE ON ALL MALE THREADED FITTINGS EXCEPT HEAD. 4. WHERE NOTED CHECK VALVE SHALL BE INSTALLED UNDER HEAD WATER LINE UNDER PAVING: USING SCHEDULE 80 NIPPLE. ALL MAINLINE UNDER PAVING SHALL BE INSTALLED 24" DEEP. ALL LATERAL LINES UNDER PAVING SHALL BE SCH 40 PVC AND INSTALLED 24" DEEP. SYSTEM COVERAGE: THE IRRIGATION CONTRACTOR IS TO ADJUST HEAD LOCATIONS IN THE FIELD IN HIGH POP-UP SPRINKLER HEAD ORDER TO GUARANTEE 100% HEAD TO HEAD COVERAGE. CONTRACTOR TO CONTACT THE CONTRACTING OFFICER PRIOR TO ANY MAJOR CHANGE(S) RESULTING IN ADDITIONAL COST TO THE OWNER, PIPE INSTALLATION: ALL PRESSURE MAINLINES ARE TO BE BURIED PER THE SPECIFICATIONS HEREIN. ALL LATERAL NON -PRESSURE LINES ARE TO BE INSTALLED AS FOLLOWS: �- 12" LATERAL LINES BURIED PER SPECIFICATIONS: * ALL LINES LOCATED AT THE BOTTOM OF SLOPE WHEN ADJACENT TO LEGEND - USE CARSON VALVE BOXES. A GRADED PAD, BENCH, CURB OR RIGHT-OF-WAY. * ALL LINES LOCATED WITHIN RIGHT-OF-WAY. 1. 10" DIAMETER CIRCULAR VALVE BOX. * ALL LINES LOCATED ADJACENT TO CURB OR SIDEWALK. 2. EDGE OF LAWN, WALK, FENCE, CURB, ETC. 3. 14" x 19" RECTANGULAR VALVE BOX. 4. 20" x 30" RECTANGULAR VALVE BOX. NOTES A. CENTER VALVE BOX OVER VALVE TO FACILITATE SERVICING OF VALVE. B. SET VALVE BOXES 2" MAXIMUM ABOVE GRADE IN MULCH COVER OR GROUNDCOVER/SHRUB AREAS - SET FLUSH WITH FINISH GRADE IN TURF AREAS. C. SET VALVE BOX AND VALVE ASSEMBLY IN GROUND- COVER/SHRUB AREA WHERE POSSIBLE - INSTALL IN TURF ONLY IF THERE IS NO ADJACENT GROUND - COVER. D. SET VALVE BOXES PARALLEL TO ONE ANOTHER AND PERPENDICULAR TO EDGE. E. AVOID HEAVY COMPACTION OF SOIL AROUND VALVE BOXES TO PREVENT THEIR DEFORMATION/COLLAPSE. VALVE BOX INSTALLATION HEAD LAYOUT FOR SHRUB HEDGE CONDITIONS ONLY. r SPRAY HEAD @ BUXUS HEDGE S TORO 570Z-PRX 12P-COM-2SST STRIP SPRAY HEAD 2X6' .09 30 11 TORO 5702-PRX-12P-COM-4EST END SPRAY HEAD 4X15' .45 30 9 TORO 570Z-PRX-12P-COM-4SST STRIP SPRAY HEAD 4X30' .90 30 TORO 570 Z-PRX-6P-COM-8Q QUARTER SPRAY HEAD 8' .25 30 ® TORO 570 Z-PRX-6P-COM-8H HALF SPRAY HEAD 8' .50 30 Q TORO 570 Z-PRX-6P-COM-8F FULL SPRAY HEAD 8' 1.0 30 �► TORO 570 Z-PRX-6P-COM-12Q QUARTER SPRAY HEAD 12' .50 30 ❑ TORO 570 Z-PRX-6P-COM-12H HALF SPRAY HEAD 12' 1.09 30 Q TORO 570 Z-PRX-6P-COM-12F FULL SPRAY HEAD 12' 2.19 30 TORO 570 Z-PRX-6P-COM-15Q QUARTER SPRAY HEAD 15' .85 30 ❑ TORO 570 Z-PRX-6P-COM-15H HALF SPRAY HEAD 151 1.65 30 TORO 570 Z-PRX-6P-COM-15F FULL SPRAY HEAD 15' 3.6 30 B TORO 570 Z-PRX-6P-SB-2-180-PC2 STREAM BUBBLER 2X6' .09 30 570 Z-PRX-6P-SB-90-PC2 CONTRACTOR TO DETERMIND QUARTER OR HALF BUBBLERS IN FIELD. CONTRACTOR MUST USE TORO 570 ADJUSTABLE ARC NOZZLES OR 570 V-15 NOZZLES TO AVOID OVERSPRAY AND INSURE FULL COVERAGE. THE CONTRACTOR MAY USE STANDARD RISERS IN SHRUB AREAS THAT ARE ADJACENT TO WALLS OR BUILDINGS UNLESS WHERE LOCATED A MINIMUM OF 3' FROM LAWN OR WALKWAY. THE CONTRACTOR IS REQUIRED TO USE 5702 -COM (CHECK-O-MATIC) ANY HEADS ON A SYSTEM WITH TOR GREATER ELEVATION CHANGE - or TO AVOID LOW READ DRAINAGE. THE 8' SPRAY HEADS MAY BE SUBSTITUTED WITH IO' NOZZLES AS REQUIRED IN THE FIELD. ANY HEADS THE NEED A REDUCTION OF MORE THAN 25/ OF THE LISTED SPRAY PATTERN WILL REQUIRE TORO PCD SCREENS. (CONTRACTOR TO INSURE 100% HEAD TO HEAD COVERAGE) 1 - F TURF 304 -00 -02 -COM TR STREAM PRAY TORO S S 21 .72 35 Q SHRUB 304 -12 -02 -COM TORO TURF 308 -00 -02 -COM FULL STREAM SPRAY 21' 1.44 35 SHRUB 308 -12 -02 -COM TORO TURF 316 -00 -02 -COM FULL STREAM SPRAY 21' 2.88 35 SHRUB 316 -12 -02 -COM TORO TURF 304 -00 -02 -COM QTR STREAM SPRAY 28' .68 35 SHRUB 304 -12 -02 -COM TORO TURF 308 -00 -02 -COM FULL STREAM SPRAY 28' 1.36 35 SHRUB 308 -12 -02 -COM TORO TURF 316 -00 -02 -COM FULL STREAM SPRAY 28' 2.72 35 SHRUB 316 -12 -02 -COM * USE A HIGH POP FOR SHRUB STREAM SPRAYS ADJACENT TO WALKS OR WHERE PEDESTRIAN TRAFFIC MAY OCCUR. RAINBIRD 33 DLRC LOCKING W/ RUBBER CAP, QUICK COUPLER. NIBCO T-113 GATE VALVE - LINE SIZE. RAINBIRD PESB-PRS-D SERIES REMOTE CONTROL VALVE - SIZES INDICATED. 0 WATER METER - REFER TO CIVIL PLAN ® BACKFLOW DEVICE - SEE P.O.C. NOTE 0 AUTOMATIC CONTROLLER LOCATION - SEE NOTE. 2" RAINBIRD 200-PESB-PRSD MASTER VALVE - PROVIDE MASTER VALVE RELAY TO CONTROLLER. DATA INDUSTRIAL HI -FLOW SHUT OFF SENSOR AND RELAY TO CONTROLLER PVC SCH 40 LATERAL LINE- 12" COVER IN PLANTING AREAS, 2411 COVER UNDER PAVING. - SIZES INDICATED. PVC SCH 40 MAINLINE 2" AND SMALLER, CLASS 315 21/2" OR LARGER - 1811 COVER IN PLANTING AREAS, 241' COVER UNDER PAVING - SIZES INDICATED. - - -- - PVC CLASS 200 WIRE SLEEVE - SIZE AND LOCATION PER CONTRACTOR PVC SCH 40 MAIN AND LATERAL LINE SLEEVE 2X DIA. OF PIPE. - PROVIDE SLEEVES UNDER ANY PAVING THAT EXCEEDS 4' WIDE. INDICATES STATION NUMBER x x= INDICATES CONTROLLER X a INDICATES GPM - IRRIGATION DESIGN CRITERIA Name of Water Supplier: West Valley Water Dlstdct 3/04/05 Pressure Given By: Lon Tsai @ Engineering (909) 875-1804 HGL - 1884 HIGH -32 LOW ZONE 6 HIGHEST ELEVATION ON THIS SYSTEM 1654 LOWEST ELEVATION ON THIS SYSTEM 1595 WATER METER ELEVATION 1635 Contractor shall verify the static water pressure with supplier prior to installation. If different from PSI noted above, Contractor to notify Owner for instructions. Failure to do so will result in contractor being responsible for changes that might occur. yve CITY OF FONTANA LANDSCAPE PLANS P OUSE DRIVE As SHOWN m IMM, MM 11-03-05 Cwx= ft t-�-v�i�G 1 �� �•t� �� vs- ice. to.: � �� CRY E)IIGIlrimi R.C.E 5tS5Z E7�. W1E sire%c,wPes Landscape Architecture and Planning 3195-B Airport Loop 0 ve Coe#a LwIeea, CA 92626 Richard Polhamus, License CA -#2762 (949) 644-9370 (714) 210-3140 FAX NO. REVISION 11-03-05 - RECGRDDRAWINGS CITY VAULT SUBMITTAL A N-00 S C4 p I` PO[y4 0 27$2 CIA �k e '���• 090w-OQ� Of CA��� DWN CHK DATE 6/08/05 JOB* 05-017 ON �A H W W Q W 8d Z �" w C) N-00 S C4 p I` PO[y4 0 27$2 CIA �k e '���• 090w-OQ� Of CA��� DWN CHK DATE 6/08/05 JOB* 05-017