IRRIGATION LEGEND
SYMBOL MFG. MODEL NO. DESCRIPTON RAD. GPM PSI
6
TORO 570 Z-PRX-12P-COM-5Q QUARTER SPRAY HEAD 5' .10
30
❑
TORO 570 Z-PRX-12P-COM-5H HALF SPRAY HEAD 5' .20
30
TORO 570 Z-PRX-12P-COM-8Q QUARTER SPRAY HEAD 8' .25
30
TORO 570 Z PRX-I2P-COM-8H HALF SPRAY HEAD 8' .50
30
TORO 570 Z-PRX-12P-COM-8F FULL SPRAY HEAD 8' 1.0
30
TORO 570 Z-PRX-12P-COM-12Q QUARTER SPRAY HEAD 12' .50
30
(b
TORO 570 Z-PRX-12P-COM-12H HALF SPRAY HEAD 12' 1.09
30
TORO 570 Z-PRX-12P-COM-12F FULL SPRAY HEAD 12' 2.19
30
TORO 570 Z-PRX-12P-COM-15Q QUARTER SPRAY HEAD 15' .85
30
Q
TORO 570 Z-PRX-12P-COM-15H HALF SPRAY HEAD 15' 1.65
30
TORO 5 70 Z-PRX- 12P -COM -15F FULL SPRAY HEAD 15' 3.60
30
❑
TORO 570Z-PRX-12P-COM-2SST STRIP SPRAY HEAD 2X6' .09
30
®
0
30
0
TORO 570Z-PRX- I2P-COM-4SST STRIP SPRAY HEAD 4X30' .90
30
+
TORO 570 Z-PRX-6P-COM-8Q QUARTER SPRAY HEAD 8' .25
30
®
TORO 570 Z-PRX-6P-COM-8H HALF SPRAY HEAD 8' .50
30
� iii tsl�i
IRRIGATION LEGEND
SYMBOL MFG. MODEL NO. DESCRIPTON RAD. GPM PSI
6
TORO 570 Z-PRX-12P-COM-5Q QUARTER SPRAY HEAD 5' .10
30
❑
TORO 570 Z-PRX-12P-COM-5H HALF SPRAY HEAD 5' .20
30
TORO 570 Z-PRX-12P-COM-8Q QUARTER SPRAY HEAD 8' .25
30
TORO 570 Z PRX-I2P-COM-8H HALF SPRAY HEAD 8' .50
30
TORO 570 Z-PRX-12P-COM-8F FULL SPRAY HEAD 8' 1.0
30
TORO 570 Z-PRX-12P-COM-12Q QUARTER SPRAY HEAD 12' .50
30
(b
TORO 570 Z-PRX-12P-COM-12H HALF SPRAY HEAD 12' 1.09
30
TORO 570 Z-PRX-12P-COM-12F FULL SPRAY HEAD 12' 2.19
30
TORO 570 Z-PRX-12P-COM-15Q QUARTER SPRAY HEAD 15' .85
30
Q
TORO 570 Z-PRX-12P-COM-15H HALF SPRAY HEAD 15' 1.65
30
TORO 5 70 Z-PRX- 12P -COM -15F FULL SPRAY HEAD 15' 3.60
30
❑
TORO 570Z-PRX-12P-COM-2SST STRIP SPRAY HEAD 2X6' .09
30
®
TORO 5702-PRX- I2P-COM-4EST END SPRAY HEAD 4X15' .45
30
0
TORO 570Z-PRX- I2P-COM-4SST STRIP SPRAY HEAD 4X30' .90
30
+
TORO 570 Z-PRX-6P-COM-8Q QUARTER SPRAY HEAD 8' .25
30
®
TORO 570 Z-PRX-6P-COM-8H HALF SPRAY HEAD 8' .50
30
TORO 570 Z-PRX-6P-COM-8F FULL SPRAY BEAD 8' 1.0
30
�►
TORO 570 Z-PRX-6P-COM-12Q QUARTER SPRAY HEAD 12' .50
30
TORO 570 Z-PRX-6P-COM-12H HALF SPRAY HEAD 12' 1.09
30
TORO 570 Z-PRX-6P-COM-12F FULL SPRAY HEAD 12' 2.19
30
TORO 570 Z-PRX-6P-COM-15Q QUARTER SPRAY HEAD 151 .85
30
V
TORO 570 Z-PRX-6P-COM-15H HALF SPRAY HEAD 15' 1.65
30
TORO 570 Z-PRX-6P-COM-15F FULL SPRAY HEAD 15' 3.6
30
®
TORO 570 Z-PRX-6P-SB-2-180-PC2 STREAM BUBBLER 2X6' .09
30
570 Z-PRX-6P-SB-90-PC2
CONTRACTOR TO DETERMIND QUARTER OR HALF BUBBLERS IN FIELD.
CONTRACTOR MUST USE TORO 570 ADJUSTABLE ARC NOZZLES OR 570 V-15
NOZZLES TO AVOID OVERSPRAY AND INSURE FULL COVERAGE.
THE CONTRACTOR MAY USE STANDARD RISERS IN SHRUB AREAS THAT ARE ADJACENT TO
WALLS OR BUILDINGS UNLESS WHERE LOCATED A MINIMUM OF 3' FROM LAWN OR WALKWAY.
THE CONTRACTOR IS REQUIRED TO USE 5702 -COM (CHECK-O-MATIC) ANY HEADS ON A SYSTEM
WITH 3' OR GREATER ELEVATION CHANGE - or TO AVOID LOW HEAD DRAINAGE.
THE 8' SPRAY HEADS MAY BE SUBSTITUTED WITH 10' NOZZLES AS REQUIRED IN THE FIELD.
ANY HEADS THE NEED A REDUCTION OF MORE THAN 25% OF THE LISTED SPRAY PATTERN
WILL REQUIRE TORO PCD SCREENS. ( CONTRACTOR TO INSURE 100% HEAD TO HEAD COVERAGE)
Q
TORO TURF 304 -00 -02 -COM QTR STREAM SPRAY 21'
.72 35
SHRUB 304 -12 -02 -COM
Q
TORO TURF 308 -00 -02 -COM FULL STREAM SPRAY 21'
1.44 35
SHRUB 308 -12 -02 -COM
TORO TURF 316 -00 -02 -COM FULL STREAM SPRAY 21'
2.88 35
SHRUB 316 -12 -02 -COM
TORO TURF 304 -00 -02 -COM QTR STREAM SPRAY 28'
.68 35
SHRUB 304 -12 -02 -COM
Q
TORO TURF 308 -00 -02 -COM FULL STREAM SPRAY 28'
1.36 35
SHRUB 308 -12 -02 -COM
TORO TURF 316 -00 -02 -COM FULL STREAM SPRAY 28'
2.72 35
SHRUB 316 -12 -02 -COM
* USE A HIGH POP FOR SHRUB STREAM SPRAYS ADJACENT TO WALKS OR WHERE
PEDESTRIAN TRAFFIC MAY OCCUR.
RAINBIRD 33 DLRC LOCKING W/ RUBBER CAP, QUICK COUPLER.
NIBCO T-113 GATE VALVE - LINE SIZE.
RAINBIRD PESB-PRS-D SERIES REMOTE CONTROL VALVE - SIZES INDICATED.
Q
WATER METER - REFER TO CIVIL PLAN
Ej
BACKFLOW DEVICE - SEE P.O.C. NOTE
0
AUTOMATIC CONTROLLER LOCATION - SEE NOTE.
l:J
2" RAINBIRD 200-PESB-PRSD MASTER VALVE - PROVIDE MASTER VALVE RELAY TO CONTROLLER.
O
DATA INDUSTRIAL HI -FLOW SHUT OFF SENSOR AND RELAY TO CONTROLLER
PVC SCH 40 LATERAL LINE- 12" COVER IN PLANTING AREAS,
24" COVER UNDER PAVING. - SIZES INDICATED.
PVC SCH 40 MAINLINE 2" AND SMALLER, CLASS 315 21/2" OR LARGER -18" COVER
IN PLANTING AREAS, 24" COVER UNDER PAVING - SIZES INDICATED.
- -
PVC CLASS 200 WIRE SLEEVE - SIZE AND LOCATION PER CONTRACTOR
PVC SCH 40 MAIN AND LATERAL LINE SLEEVE 2X DIA. OF PIPE. -
PROVIDE SLEEVES UNDER ANY PAVING THAT EXCEEDS 4' WIDE.
INDICATES STATION NUMBER
X X'
INDICATES CONTROLLER
x �----
INDICATES GPM
INDICATES VALVE SIZE
■lLZ�S*1iY\
K LANE
I I
t I �■
�ll1AIT 0 WOR
yy
S ��a•�■ SiS�i� �
J �•
! �1
�' ■ ��� ,
�1
I I 2o4
�%
Sol
M
1�
M
s j
44
Nl`
1
84` 1 2.
+0`
44"
MIT OF WO
00 627.7
LU
w
I 1
LSI
II to
!
26.7
____... Y Y
POINT OF CONNECTION: 'C'
INSTALL A 11/2" (DOMESTIC) WATER METER - SEE CIVIL PLAN FOR LOCATION.
INSTALL A 11/2" FEBCO 825YA REDUCED PRESSURE TYPE BACKFLOW DEVICE.
INSTALL IN PLANTER AREAS AWAY FROM PEDESTRIAN TRAFFIC.
MASTER VALVE / PRESSURE REGULATOR TO BE SET 0 85 PSI
COORDINATE THESE LOCATIONS WITH OWNER/ DEVELOPER.
AVAILABLE PRESSURE : 69.71 PSI
DESIGN PRESSURE 68.13 PSI
MAXIMUM !DEMAND 26 GPM
F46 ZONE NGL (LOW 1786 TO HIGH 1812)
INA TER METER : 1625
HIGHEST HEAD SERVED 1650
WATER METER - FONTANA WATER DISTRICT (626) 448-6183 JACK SWE
RUSSELL OR CARLOS IN ENGINEERING DEPT.
P.O.C. DIAGRAM
METER -
BACKFLOW DEVICE -
FLOW SENSOR
MASTER VALVE
PIPE SLING 1 SLEEVING
THIS LEGEND TO BE USED FOR LATERAL LINE PIPE
INSTALLATION. ALL MAINLINE TO BE SIZED AS
INDICATED ON PLAN
PIPE SIZE GPM's APPROX. 4 HEADS
314" 1-8 1-10
1" 9-14 11-14
11/411 14-23 15-20
11/211 24-34 21-30
2" 35-45 31-35+
NOTE: LATERAL SIZE IS SHOWN AT EACH VALVE EXIT.
NOTE: CONTRACTOR IS REQUIRED TO PROVIDE
SLEEVING FOR ALL LATERAL LINE AND MAINLINE
UNDER ALL PAVING SURFACES THAT EXCEED 4' WIDE.
CONTROLLER ASSEMBLY: 'C'
CA 1 -RB l -40/MVR/EIFS-150/RSEIEMP-16 / PAIGE P7162D FLOW SENSING
CABLE. OR MATCHED APPROVED EQUAL PER OWNER.
ASSEMBLY AVAILABLE THROUGH UNITED GREEN TECH (800) 427-0779
CONTRACTOR TO PROVIDE 1 10 CONTINUOUS POWER AND MAKE FINAL HOOK UP.
LOCATE IN AN AREA FREE FROM OVERHEAD OBSTRUCTION. COORDINATE
THESE LOCATIONS WITH DEVELOPER.
4 1/ C A/ / / C SCALE
7"20'
FOR IRRIGATION NOTES. LEGEND & DETAILS SEE SHEETS L-8 & L-9