HomeMy WebLinkAbout3971-2Is
N
I
. ........ . .... ...... . .............. ...... .............. . ..
IRRIeATION EGUIPMENT LEOENP
0
5ym
VE-50Rlizm0t4
=to *9ZATY", -m" JkA��mmwtz.
MANUF.
IPA;
MODEL
P51
OFM
RAV.
NOTE5
J-1 IffiP 41t 111'=*064
B1 I 2S It 011110,1PI
v
POP-UP SPRA"( SPRIWQER
RAIN BIRD
1,512-SAWFRS-20
50
052
ba
ADJJST AS REWIRM, SEE DUAIL A SKEET 4
v
POP4JP 5FRA*f SPRINKLER
RAIN BIRD
012-SAM-PR54VAern,
50
VARIES
V
ADJL6T A5 REWIRED, SEE MAIL A 5HEET 4
(5
O" "^ 5FRAr 5FRINKLER
RAIN BIW
1612-5AM-FR5-100
50
0.5q
101
AV46T A5 REGUIREPo SEE 12ETAIL A 5HEET 4
NOTE: PRE55URE T9 5E RE64)LATEV T070 AFTER RP DEVISE
FOP -UP 5FRA"r SPRINKLER
RAIN 51RD
1612-5AM-FR-5-10H
50
01IR
101
AVJr5T AS REWIRED, SEE VETAIL A 5HEET 4
FOF-W 5FRAY 5PRINKILER
RAIN 51W
1612-SAM-PR.5-U-150
so
OA5
is,
AWLST AS REOUIRED, SEE PETAIL A SHEET 4
15
POP -W 5FRA"r S?RIWLER
RAIN BIRD
Ib12-5AM-FR5-U-I5H
50
126
151
ADWST AS REOUIREI;� -SEE 12ETAIL A SHEET 4
m
POP-iP SPRAY SFRINKLER
RAIN BIRD
1612-5AM-FRS-15VAN
50
VARIES
15,
ADJUST AS REQUIRED, -SEE VETAIL A SHEET 4
C)
POP -W 5MA"r SPRINKLER
RAIN 51RD
I&76-5AM-fR5-50
50
026
ADJJ5T AS REGAREIP, 50 PETAIL A SHEET 4
POP4P SPRAY SPRINKLER
RAIN BIRD
50
052
.r %,M AS REOUIVin, ED, SEE DETAIL A SHEET 4
FOF-W 5FRA"r 5FRINKLER
RAIN BIRD
1Wb--5AM-FRS-WAN
50
VARIES
�5
ADJJ5T AS REMIRM, 5= DETAIL A SHEET 4
ED
[D
ELWTRIC CONTROLLER
ELr;k,`TRI0 METER
TORO
omeR
TOW INAL *; 55AK24F516W 24 STA.
__FJELp_5A_TF.LLLTIE I ;LM
INSTALLED IN CONTROLLER ENCLOSLRE
SEE DETAIL 5 SHEET 4
PROVIPED BY on4m
Z 1150
....... ....
�9
IR96ATION CONTROL VALVE
SWERIOR
q5,CVkq SMIES-51ZE AS SHOM
SEE DETAIL E SHEET 4
'rot v
I Ewer,
All
"t v
102
FRICMON (PS1 LOSS) VALVE NO. 1 50
C7PM
211 5LEEVE
CT -15 FIRES
2" BACKFLON PREVENTER
1250
M-EVATION CHANCES:
-
LATERAL LINM
2.0
MAIN LINE (600 LF)
15.1
PIN65 (20% OF MAIN LINE)
2b
1-1/2's VALVE
I.
misc.
2.0
TOTAL ni L055
551DO
k4ATER FRE-55LIRE
110 F.51
LESS TOTAL F51 L055
74.20
EQUALS
MINIMUM TO FARTHEST HEAD
-1420
SPRINKLER OFERATINC-7 PRESWIRE
50.00
RESIDUAL tqATM PRESSURE
44.2o
NOTE: PRE55URE T9 5E RE64)LATEV T070 AFTER RP DEVISE
INFORMATION 05TNEP FWM KMTH
FONTANA PiATER CO. - 10/1104, (626) 44&-6155
SCH 40 PVC SUMVIN67 CHART
1-1/2" SLEEVE 4-& HIRES
3/41, FIFE
211 5LEEVE
CT -15 FIRES
I" PIPE
2-1/2" 5LEEVE
16-24 IIRE-5
1-1/4" FIFE
5" SLEEVE
25-55 V41RE5
1-1/2" FIFE
41, SLEEVE
56-50 v4II
2 2-1/2" PIPE
61, SLEEVE
51-100 NiRE5
5" 4" FIFE
CONTRACTOR TO
CONFIRM LOCATION
OF CONTROLLER
K/ CITY PRIOR TO
INSTALLATION.
CONTROLLER 5HOAN
INSIDE OF MALL
FOR. GRAPH15 CLARITY
ONLY'. ACTUAL CONTROLLER
TO BE PLACED IN OFD AREA
MIMOSA j 15j 'I''
COURT - I �I
I-RR16ATION SPECIFICATION'S
ALL NORK SHALL BE IN AC ' CORDANCE V41TH THE C,17'� OF FONTANA'S LANDSCAPE DEVELOPMENT
STANDARD LANDSCAPE SPECIFICATION MANUAL FOR 5TREET5CAPE-5 AND PARKS.
VURIF)'ALL CONPITION5 AND PIMEN51ON5 PRIOR To GOMMENOINO AN --r NORK, NOTIFY THE
LAND50APE ARCHITECT IMMEDIATELr IF ANY DISCREPANCY 15 FOUNP.', CONTRACTOR SHALL
THoF,oU6HL',r FAMILIARIZE HIMSELF KITH ALL SITE GONPITION5 PRIOR TO BIDDING OR
COMMENCIN5 VqORK.
EXTREME CARE SHALL BE EXER,05ED YiHEN NORKINO ADJACENT TO ANY5TRUOTURE5 OR
UTILITIES. CONTRACTOR SHALL BE RE5PON51BLE FOR LOCATING, ALL EXISTIN5 UTILITIE5 ARD
REPAIRIN5, ANY DAMAOE5 CAUSED B'YHI5 NORK AT NO COST TO THE OMER.
IRRIGATION DESIGN IS BASED ON AN AVAILABLE DATER FRE55URE OF 110 P.5.1. KITH A
MAXI1vUM5Y5TEM DEMAND OF 50 5.P.M. CONTRACTOR SHALL VERIFY" DATA PRIOR TO
OOMMENC,INO V4ORK. MATER AVAILABILITY INFORMATION M5 05TAINEP FROM FONTANA WATER
COMPANY'.
MAKE POINT OFCONNECTIONAT THE ?qATER METER AS 5HONN ON THE PLANS AND RUN A
1-1/2" 500 40 MAINLINE Ib" DEEP TO AREAS NHERE VALVE5 ARE LOCATED.
IN5TALL LINE SIZE GATE VAL'v`E5 IN ROUND PLASTIC BOXES NHERE INDICATED.
THE LANDSCAPE AROHITEGT SHALL BE RESPONSIBLE FOR THE INTERPRETATION OF THE
PRANIN55 SHOULD A QUESTION AR15E.
PIPING 5HONN ON THE PLANS IS E55ENTIALLY DIAGRAMMATIC, ROUTE PIPING AND LOCATE
VALVES TO AVOID CONFLICT Y41TH STATIONARY ELEMENTS. kiHEN VERTICAL 005T'RUOTION5
(FIRE HYDRANTS, LIGHTS, TREES ETC) INTERFERE PTTH THE SPRAY PATTERN OF THE HEADS,
THE IRR15ATION CONTRACTOR SHALL FIELD ADJUST THE SPRINKLER 5Y.5TEM AT NO ADDITIONAL
r.,05T TO THE OWNER, BY INSTALLING A QUARTER OR HALF HEAD SPRINKLER ON EACH 511E OF
THE OBSTRUCTION 50 AS TO PROVIDE PROPER COVERAGE. LOCATE ALL VALVES AND 5AGKFLON
DEVIGE IN 5HRJJB BEDS AHERE POSSIBLE.
NIRIN 67 FROM THE CONTROLLER TO THE VALVES SHALL BE DIRECT BURIAL A.FA,, MINIMUM
14 GAUGE. PROVIDE CONTINUOUS SPARE NIRE5 TO VALVE(S) FURTHEST FROM THE
CONTROLLER. LOOP DIRE INTO EACH VALVE BOX ALONG THE MAINLINE KITH A MIN. 500
EXPANSION COIL. SPARE WIRE 15 TO BE A DIFFERENT COLOR FROM OTHER CONTROL YqIRES.
LABEL P41RE 5PARE IN CONTROLLER.
PROVIDE CHECK VALVE -5 AS NEEDED TO ELIMINATE ALL LOBI HEAP PRAINA6E.
ALL EQUIPMENT SHALL BE AS LISTED IN THE LE6ENP. SUBSTITUTIONS MILL. NOT BE
PERMITTED NITHOUT PRIOR APPROVAL OF THE LANDSCAPE ARCHITECT,
CONTRAOTOR SMALL PROVIDE COMPLETE AND ACCURATE RECORD PRAV41NGS TO THE CITY UPON
COMPLETION OF THE PROJECT. PRANIN05 SHALL INDICATE ANY CHANGES FROM THE ORIGINAL
PLANS AND DIMEN51ON5 OF VALVES, OU10K COUPLERS, CONTROLLERS AND ALL,OTHER
EQUIPMENT FROM STATIONARY POINTS OF REFERENCE.
DESIGN INTENT S TO PROVIDE COMPLETE IRRIGATION COVERAGE TO ALL PLANTED AREAS, AS
FIELD CHAN 6E MAY OCCUR, CONTRACTOR 15 REQUIRED TO PROVIDE I,qo' COVERAGE TO ALL
AREAS. IN NO INSTANCE SHALL HEAD SPACING EXCEED 55% OF MANUFACTURERS RECOMMENDED
SPAOIN6 FOR, COVERAGE CONTRACTOR SHALL NOT KNONINOLY INSTALL A SPRINKLER 5Y5TEM
1 LAN SC PE ARCHITECT SHALL RESULT IN
THE CONTRACTOR REPAIRIN5/REP AOIN5 SAID 5Y5TEM AT 1 15 OR HER EXFEN5E.
ALL SPRINKLER HEAP5 IN5TALLEE? ,ADJACENT TO rUR55 AND KALK5 SHALL BE POP-UP TYPE.
IN NO INSTANCE SHALL RISER TYPE SPRINKLERS BE INSTALLED ADJACENT TO PEDESTRIAN
AREA5.
THE CON7`RACTORSHALL FLU5H AND ADJUST ALL SPRINKLER HEADS FOR, OPTIMUM PERFORMANCE
AND 70 MINIMIZE OVERSFRAY ONTO WALKS, ROAPKAY5 ANP/OR BUILDINGS. THIS SHALL
INCLUDE SELECTING THE BEST DEGREE OF ARO TO FIT THE EXISTING SITE CONDITIONS AND
TO THROTTLE THE FLOV4 CONTROL AT EACH VALVE TO OBTAIN THE OPTIMUM PRESSURE FOR EACH
5Y5TEM.
ALL PIPING AND P41RINO UNDER PAVING SHALL BE SLE -E=- IN A 50H. 40 PVC FIFE, 51ZE
AS RE-aUIRED AND KITH A MINIMUM COVER TO FIN15HED PAVEMENT GRADE OF 24°f.
ALL EOUIPI'�NT SHALL BE INSTALLED PER DETAILS, IN THE A55ENCE OF DETAIL5,
INSTAL LATIONSHALL BE IN AGGORDANCE KITH THE 5TANPARE) PRAOTiOE OF THE TRADE.
CONTRACTOR SHALL OUARANTEE ALL MATERIAL AND NORKMANSHIF FOR A PERIOD OF ONE YEAR
FROM DATE OF FINAL ACCEPTANCE BY THE ONNER,
PROVIDE A COLOR GODED LAMINATED CONTROLLER CHART IN THE GONTROLLER SHOWING THE
VALVES AND AREAS SERVED BY EACH VALVE.
BEFORE 5EOINNIN15 C ?NST UGTION, THE CONTRACTOR MUST OBTAIN ALL NECE55ARY PERMITS
FROM THE G17Y.
THE IRRIGATION SYSTEM PqILL BE TESTED BY THE OMER5 REFRE-551TATIVE IN THE FIELD
BEFORE FINAL AFFROVAL.
INSTALL ALL GOMFONENT5 PER CURRENT U.P.C. AND LOCAL CODES.
CONTRACTOR SHALL MAINTAIN A CLEAN AND SAFE NORKIN 6, ENVIRONMENT. DAY AND NI5HT
BARRICADES MUST BE PROVIDED FOR ALL OPEN TRENCHES.
THE CONTRACTOR SHALL BE RE5FON515LE FOR CONTACTING THE UNDERGROUND SERVICE ALERT
AT I-,_500-221-2-600 AT LEAST 45 HOURS PRIOR TO TRENCHIN5 FOR EXACT UNDERGROUND
UTILITY LOGATION5. THE GONTRACTOR ASSUMES ALL RESPONSIBILITY FOR THE REPAIR OR
REPLACEMENT OF,UNDERGROUND UTILITIES OR 5TRUCTURZ-5 ViHIGH ARE DAMAGED DURIN5 THE
COURSE OF COMFLETIN6 THIS INORK.
20 0 20 40 60
Scale 1
�tCITY OF FONTANA, CALIFORNIA
TRACT NO. 16346 CFD AREAS
DRAWN BY:
SCALE:
CAD 1. =20'