HomeMy WebLinkAbout3930-5IRRIGATION LEGEND
IRRIGATION NOTES
DIAGRAMMATIC PLAN
THIS SYSTEM IS DIAGRAMMATIC. ALL PIPE, VALVES, ETC. SHOWN WITHIN PAVED
AREAS ARE FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED IN
PLANTING AREAS AND JOINT TRENCHES WHEREVER POSSIBLE.
SPRINKLER ADJUSTMENT REQUIRED
THE IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLER HEADS
FOR OPTIMUM PERFORMANCE AND PREVENT OVERSPRAY ONTO WALKS AND
ROADWAYS AS MUCH AS POSSIBLE. THIS SHALL INCLUDE SELECTING THE BEST
DEGREE OF ARC TO FIT THE EXISTING SITE CONDITIONS. CONTRACTOR TO USE
PRESSURE COMPENSATING SCREENS WHEN RADIUS IS REDUCED MORE THAN FIFTY
PERCENT (50%).
FIELD CONDITIONS
DO NOT WILLFULLY INSTALL THE SPRINKLER SYSTEM AS INDICATED ON THE
DRAWINGS WHEN IT 1S OBVIOUS IN THE FIELD THAT UNKNOWN OBSTRUCTIONS OR
GRADE DIFFERENCES EXIST AND SHOULD BE BROUGHT TO THE ATTENTION OF THE
CONTRACTING OFFICER. IN THE EVENT THAT THIS NOTIFICATION IS
NOT PERFORMED, THE CONTRACTOR MUST ASSUME FULL RESPONSIBILITY FOR ANY
REVISIONS REQUIRED.
SWING JOINTS.
INSTALL ALL HEADS WITH DOUBLE OR TRIPLE SUITING JOINTS, USING STREET ELLS,
AS PER DETAIL.
MINIMUM PRESSURE AND MAXIMUM GALLONS REQUIRED
THE SPRINKLER SYSTEM DESIGN IS BASED ON A MINIMUM OPERATIONAL PRESSURE
AND A MAXIMUM DEMAND AT THE POINT OF CONNECTION, AS NOTED ON THE PLAN.
BEFORE INSTALLING THE SYSTEM, CHECK POINT OF CONNECTION AND IMMEDIATELY
NOTIFY CONTRACTING OFFICER IF PRESSURE IS NOT AS NOTED OR THE REQUIRED
GALLONS PER MINUTE IS NOT AVAILABLE.
WATER LINE UNDER PAVING
ALL MAINLINE UNDER PAVING SHALL BE INSTALLED 24" DEEP. ALL LATERAL LINES
UNDER PAVING SHALL BE SCH 40 PVC AND INSTALLED 24" DEEP.
SYSTEM COVERAGE
THE IRRIGATION CONTRACTOR IS TO ADJUST HEAD LOCATIONS IN THE FIELD IN
ORDER TO GUARANTEE 100% COVERAGE. CONTRACTOR TO CONTACT THE
CONTRACTING OFFICER PRIOR TO ANY MAJOR CHANGE(S) RESULTING IN
ADDITIONAL COST TO THE OWNER.
IRRIGATION DESIGN CRITERIA
Name of Water Supplier: West Valley Water District 3104105
Pressure Given By: Lon Tsai @ Engineering (909) 875-1804
HGL - 1884 HIGH -32' LOIN
ZONE 6
HIGHEST ELEVATION ON THIS SYSTEM 1648
LOWEST ELEVATION ON THIS SYSTEM 1595
(NATER METER ELEVATION 1635
Contractor shall verify the static water pressure with supplier
prior to installation. if different from PSI noted above, Contractor
to notify Owner for instructions. Failure to do so will result
in contractor being responsible for changes that might occur.
Underground Service Alert
F o y�
Calk TOLL FREE
GY
1-800
422-4133
1W0 WORKING DAYS BEFORE YOU DIG
SYMBOL DESCRIPTON
'DATA INDUSTRIAL'- HFSM-1.5 FLOW SENSOR
RAINBIRD QUICK COUPLER 33 DLRC - Locate in a 10" round lockable plastic valve box
@ 150' o.c. maximum. Support with a rebar stake and two house clamps
each.
AUTOMATIC CONTROLLER LOCATION - SEE CONTROLLER NOTE ON PLAN.
Provide controller charts per City requirements.
Contractor to also install a Rainguard moisture sensor @ the controller. Locate
in a vandal resistant area free from overhead obstruction and outside of the
irrigation spray pattern.
MAINLINE - SEE DETAIL FOR INSTALLATION DEPTHS. - SIZES INDICATED.
Mainlines (pressurized) 1112 inch and smaller shall be Schedule 40 solvent -weld P.V.C.
Mainlines (pressurized) 2 inch through 3 inch shall be Class 315 solvent -weld P.V.C.
CONTRACTOR TO USE INSTALL THRUST BLOCKS TO 2" MAINLINE,
PVC SCH 40 LATERAL LINE- 12" COVER IN PLANTING AREAS.
PVC SCHED. 40- 24" COVER UNDER PAVING
- - WIRE SLEEVES - WIRE CONDUIT TO BE SCH 40 GRAY PVC PIPE. ( LATERAL AND
MAINLINE PIPE RUNS TO BE INSTALLED IN SEPERATE SLEEVES.)
- WIRE SLEEVES, MUST BE OVERSIZED LEAVING AMPLE ROOM FOR FOR
FUTURE WIRE ADDITIONS OR REPAIRS, 2X THE DIA OF THE SLEEVE CONTENTS
PVC SCH 40 MAIN AND LATERAL LINE SLEEVE 2x DIA. OF PIPE ENCASED. - PROVIDE
- - - - _ - - - SLEEVES UNDER HARDSCAPE (CONCRETE /ASPHALT IN EXCESS OF 4' WIDE).
INDICATES STATION NUMBER
X XINDICATES CONTROLLER
x INDICATES GPM
INDICATES VALVE SIZE
QTY
1
26
1
50'@3"
1995'@ 2 112"
450' @ 1 114"
520` @ 1 "
6442' @ 314"
400'
400'
FLAN VIE
TYP. CONCRETE TO REST
AGAINST UNDISTURBED
SOIL
ELEVAI1ON
f
i
TYP. CONCRETE
THRUST BLOCKS
NOTE: THRUST BLOCKS SHALL BE INSTALLED IN ACCORDANCE WITH PIPE j
MANUFACTURER'S RECOMMENDATION FOR SIZE OF PIPING REQUIRED.
UTILIZED IN ALL (2 1/2- AND LARGEI1 MAINUNE PIPE)
#3 RESAR TO 4E PLACED AROUND PIPE INTO THRUST BLOCK TYR
FUP APPROVED BY: CI'T'Y OF FONTANA
CrIY ENGINEDATE: TN IVT BLOK
ER
'25126 ROBERT W. W EDDL E A55EMIXY
EW. 12/31/01 DRAWN BY: 11MOTHY KASTEOT.
OWL
`F DATE OF LAST REVISION: STD. PLAN NA. r,')n ANT I ncl
TH-R-U-ST BLOCK DETAIL
POINT OF CONNECTION : 'A'
INSTALL A 11/2- (DOMESTIC) WATER METER - SEE CIVIL PLAN FOR LOCATION.
INSTALL A 11/2 FEBCO 825YA REDUCED PRESSURE TYPE BACKFLOW DEVICE.
INSTALL IN PLANTER AREAS AWAY FROM PEDESTRIAN TRAFFIC.
MASTER VALVE / PRESSURE REGULATOR TO BE SET @ 85 PSI
COORDINATE THESE LOCATIONS WITH OWNER/ DEVELOPER.
AVAILABLE PRESSURE 69.71 PSI
DESIGN PRESSURE 67 8 PSI
MAXIMUM DEMAND 25 GPM
F46 ZONE HGL (LOW 1786 TO HIGH 1812)
WA TER METER 1625
WATER METER - FONTANA WATER DISTRICT (626) 448-6183 JACK SWE
RUSSELL OR CARLOS IN ENGINEERING DEPT.
IRRIOATION I�IORST CONDITION
SYMBOL
MFG. MODEL NO.
DESCRIPTON RAD.
GPM
PSI QTY
8
TORO
570Z-PRX-12P-COM-2SST
TREE BUBBLER
2X6'
A9
30 17
Ih
RAINBIRD
1812 -SAM -PRS -MPR -NP -50
QUARTER SPRAY HEAD
5''
.10
30 55
❑
RAINBIRD
1812 -SAM -PRS -MPR -NP -5H
HALF SPRAY HEAD
5'
2.0
30 75
4
RAINBIRD
1812 -SAM -PRS -MPR -NP -8Q
QUARTER SPRAY HEAD
8'
.26
30 7
0
RAINBIRD
1812 -SAM -PRS -MPR -NP -8H
HALF SPRAY HEAD
8'
.52
30 248
TOTAL SYSTEM LOSS
RAINBIRD
1812 -SAM -PRS -MPR -NP -8F
FULL SPRAY HEAD
8'
1.05
30 4
dl
RAINBIRD
1812 -SAM -PRS -MPR -NP -12Q
QUARTER SPRAY HEAD
12'
.65
30 8
m
RAINBIRD
1812 -SAM -PRS -MPR -NP -12H
HALF SPRAY HEAD
12'
1.3
30 73
RAINBIRD
1812 -SAM -PRS -MPR -NP -12F
FULL SPRAY HEAD
12'
2.6
30 0
d)
RAINBIRD
1812 -SAM -PRS -MPR -NP -15Q
QUARTER SPRAY HEAD
15'
.92
30 7
O
RAINBIRD
1812 -SAM -PRS -MPR -NP -15H
HALF SPRAY HEAD
15'
1.85
30 51
G
RAINBIRD
1812 -SAM -PRS -MPR -NP -15F
FULL SPRAY HEAD
15'
3.7
30 0
RAINBIRD
1806 -SAM -PRS -MPR -NP -8Q
QUARTER SPRAY HEAD
8'
.26
30 16
RAINBIRD
1806 -SAM -PRS -MPR -NP -8H
HALF SPRAY HEAD
8'
.52
30 101
RAINBIRD
1806 -SAM -PRS -MPR -NP -8F
FULL SPRAY HEAD
8'
1.05
30 0
RAIN BIRD
1806 -SAM -PRS -MPR -NP -12Q
QUARTER SPRAY HEAD
12'
.65
30 5
RAIN BIRD
1806 -SAM -PRS -MPR -NP -12H
HALF SPRAY HEAD
12'
1.3
30 0
RAIN BIRD
1806 -SAM -PRS -MPR -NP -12F
FULL SPRAY HEAD
12'
2.6
30 0
�]
RAIN BIRD
1806 -SAM -PRS -MPR -NP -150
QUARTER SPRAY HEAD
15'
.92
30 6
D
RAIN BIRD
1806 -SAM -PRS -MPR -NP -15H
HALF SPRAY HEAD
15'
1.85
30 2
D
RAIN BIRD
1806 -SAM -PRS -MPR -NP -15F
FULL SPRAY HEAD
15'
3.7
30 0
®
RAINBIRD
1806-SAM-PRS-MPR-NP-I5RCS/15LCS
END SPRAY HEAD
4X15'
.61
30 24
®
RAINBIRD
1806 -SAM -PRS -MPR -NP -15 SST
STRIP SPRAY HEAD
4x30'
1.21
30 86
RAINBIRD
5006 -PL -PC -SAM -MPR -25Q
QTR ROTOR HEAD
23'
.74
25 0
�2
RAINBIRD
5006 -PL -PC -SAM -MPR -25H
HALF ROTOR HEAD
23'
1.44
25 0
RAINBIRD
5006 -PL -FC -SAM -MPR -25F
FULL ROTOR HEAD
23'
2.78
25 0
(CONTRACTOR TO DECIDE IN FIELD WHICH
BUBBLER TO INSTALL)
CONTRACTOR MUST USE TORO 570 ADJUSTABLE ARC NOZZLES
OR 570 V-15
NOZZLES TO AVOID OVERSPRAY AND
INSURE FULL COVERAGE.
THE CONTRACTOR IS REQUIRED TO USE 570Z -CONI (CHECK-O-MATIC)
POP-UP BODYS ON ANY HEADS ON A SYSTEM WITH 3' OR GREATER THAN
ELEVATION CHANGE- OR AS NEEDED IN FIELD.
THE 8' SPRAY HEADS MAY BE SUBSTITUTED WITH 10' NOZZLES AS REQUIRED
IN
THE FIELD. ANY HEADS THE NEED A REDUCTION
OF MORE THAN 50% OF THE
LISTED SPRAY PATTERN WILL REQUIRE TORO PCD SCREENS.
FRI 1 112" WATER METER - REFER TO CIVIL PLAN
1
® 1 112" FEBCO 825Y REDUCED PRESSURE BACKFLOW PREVENTER WI 2"
WYE -STRAINER 1
- SEE DETAILS
NIBCO BRASS BALL VALVE (LINE SIZE) T-585-70 (314"-2")1 T-580-70-66 (2-314"-3")
4
SUPERIOR 950 DW SERIES REMOTE CONTROL VALVE - SIZES INDICATED
32
IRRIGATION NOTES
DIAGRAMMATIC PLAN
THIS SYSTEM IS DIAGRAMMATIC. ALL PIPE, VALVES, ETC. SHOWN WITHIN PAVED
AREAS ARE FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED IN
PLANTING AREAS AND JOINT TRENCHES WHEREVER POSSIBLE.
SPRINKLER ADJUSTMENT REQUIRED
THE IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLER HEADS
FOR OPTIMUM PERFORMANCE AND PREVENT OVERSPRAY ONTO WALKS AND
ROADWAYS AS MUCH AS POSSIBLE. THIS SHALL INCLUDE SELECTING THE BEST
DEGREE OF ARC TO FIT THE EXISTING SITE CONDITIONS. CONTRACTOR TO USE
PRESSURE COMPENSATING SCREENS WHEN RADIUS IS REDUCED MORE THAN FIFTY
PERCENT (50%).
FIELD CONDITIONS
DO NOT WILLFULLY INSTALL THE SPRINKLER SYSTEM AS INDICATED ON THE
DRAWINGS WHEN IT 1S OBVIOUS IN THE FIELD THAT UNKNOWN OBSTRUCTIONS OR
GRADE DIFFERENCES EXIST AND SHOULD BE BROUGHT TO THE ATTENTION OF THE
CONTRACTING OFFICER. IN THE EVENT THAT THIS NOTIFICATION IS
NOT PERFORMED, THE CONTRACTOR MUST ASSUME FULL RESPONSIBILITY FOR ANY
REVISIONS REQUIRED.
SWING JOINTS.
INSTALL ALL HEADS WITH DOUBLE OR TRIPLE SUITING JOINTS, USING STREET ELLS,
AS PER DETAIL.
MINIMUM PRESSURE AND MAXIMUM GALLONS REQUIRED
THE SPRINKLER SYSTEM DESIGN IS BASED ON A MINIMUM OPERATIONAL PRESSURE
AND A MAXIMUM DEMAND AT THE POINT OF CONNECTION, AS NOTED ON THE PLAN.
BEFORE INSTALLING THE SYSTEM, CHECK POINT OF CONNECTION AND IMMEDIATELY
NOTIFY CONTRACTING OFFICER IF PRESSURE IS NOT AS NOTED OR THE REQUIRED
GALLONS PER MINUTE IS NOT AVAILABLE.
WATER LINE UNDER PAVING
ALL MAINLINE UNDER PAVING SHALL BE INSTALLED 24" DEEP. ALL LATERAL LINES
UNDER PAVING SHALL BE SCH 40 PVC AND INSTALLED 24" DEEP.
SYSTEM COVERAGE
THE IRRIGATION CONTRACTOR IS TO ADJUST HEAD LOCATIONS IN THE FIELD IN
ORDER TO GUARANTEE 100% COVERAGE. CONTRACTOR TO CONTACT THE
CONTRACTING OFFICER PRIOR TO ANY MAJOR CHANGE(S) RESULTING IN
ADDITIONAL COST TO THE OWNER.
IRRIGATION DESIGN CRITERIA
Name of Water Supplier: West Valley Water District 3104105
Pressure Given By: Lon Tsai @ Engineering (909) 875-1804
HGL - 1884 HIGH -32' LOIN
ZONE 6
HIGHEST ELEVATION ON THIS SYSTEM 1648
LOWEST ELEVATION ON THIS SYSTEM 1595
(NATER METER ELEVATION 1635
Contractor shall verify the static water pressure with supplier
prior to installation. if different from PSI noted above, Contractor
to notify Owner for instructions. Failure to do so will result
in contractor being responsible for changes that might occur.
Underground Service Alert
F o y�
Calk TOLL FREE
GY
1-800
422-4133
1W0 WORKING DAYS BEFORE YOU DIG
SYMBOL DESCRIPTON
'DATA INDUSTRIAL'- HFSM-1.5 FLOW SENSOR
RAINBIRD QUICK COUPLER 33 DLRC - Locate in a 10" round lockable plastic valve box
@ 150' o.c. maximum. Support with a rebar stake and two house clamps
each.
AUTOMATIC CONTROLLER LOCATION - SEE CONTROLLER NOTE ON PLAN.
Provide controller charts per City requirements.
Contractor to also install a Rainguard moisture sensor @ the controller. Locate
in a vandal resistant area free from overhead obstruction and outside of the
irrigation spray pattern.
MAINLINE - SEE DETAIL FOR INSTALLATION DEPTHS. - SIZES INDICATED.
Mainlines (pressurized) 1112 inch and smaller shall be Schedule 40 solvent -weld P.V.C.
Mainlines (pressurized) 2 inch through 3 inch shall be Class 315 solvent -weld P.V.C.
CONTRACTOR TO USE INSTALL THRUST BLOCKS TO 2" MAINLINE,
PVC SCH 40 LATERAL LINE- 12" COVER IN PLANTING AREAS.
PVC SCHED. 40- 24" COVER UNDER PAVING
- - WIRE SLEEVES - WIRE CONDUIT TO BE SCH 40 GRAY PVC PIPE. ( LATERAL AND
MAINLINE PIPE RUNS TO BE INSTALLED IN SEPERATE SLEEVES.)
- WIRE SLEEVES, MUST BE OVERSIZED LEAVING AMPLE ROOM FOR FOR
FUTURE WIRE ADDITIONS OR REPAIRS, 2X THE DIA OF THE SLEEVE CONTENTS
PVC SCH 40 MAIN AND LATERAL LINE SLEEVE 2x DIA. OF PIPE ENCASED. - PROVIDE
- - - - _ - - - SLEEVES UNDER HARDSCAPE (CONCRETE /ASPHALT IN EXCESS OF 4' WIDE).
INDICATES STATION NUMBER
X XINDICATES CONTROLLER
x INDICATES GPM
INDICATES VALVE SIZE
QTY
1
26
1
50'@3"
1995'@ 2 112"
450' @ 1 114"
520` @ 1 "
6442' @ 314"
400'
400'
FLAN VIE
TYP. CONCRETE TO REST
AGAINST UNDISTURBED
SOIL
ELEVAI1ON
f
i
TYP. CONCRETE
THRUST BLOCKS
NOTE: THRUST BLOCKS SHALL BE INSTALLED IN ACCORDANCE WITH PIPE j
MANUFACTURER'S RECOMMENDATION FOR SIZE OF PIPING REQUIRED.
UTILIZED IN ALL (2 1/2- AND LARGEI1 MAINUNE PIPE)
#3 RESAR TO 4E PLACED AROUND PIPE INTO THRUST BLOCK TYR
FUP APPROVED BY: CI'T'Y OF FONTANA
CrIY ENGINEDATE: TN IVT BLOK
ER
'25126 ROBERT W. W EDDL E A55EMIXY
EW. 12/31/01 DRAWN BY: 11MOTHY KASTEOT.
OWL
`F DATE OF LAST REVISION: STD. PLAN NA. r,')n ANT I ncl
TH-R-U-ST BLOCK DETAIL
POINT OF CONNECTION : 'A'
INSTALL A 11/2- (DOMESTIC) WATER METER - SEE CIVIL PLAN FOR LOCATION.
INSTALL A 11/2 FEBCO 825YA REDUCED PRESSURE TYPE BACKFLOW DEVICE.
INSTALL IN PLANTER AREAS AWAY FROM PEDESTRIAN TRAFFIC.
MASTER VALVE / PRESSURE REGULATOR TO BE SET @ 85 PSI
COORDINATE THESE LOCATIONS WITH OWNER/ DEVELOPER.
AVAILABLE PRESSURE 69.71 PSI
DESIGN PRESSURE 67 8 PSI
MAXIMUM DEMAND 25 GPM
F46 ZONE HGL (LOW 1786 TO HIGH 1812)
WA TER METER 1625
WATER METER - FONTANA WATER DISTRICT (626) 448-6183 JACK SWE
RUSSELL OR CARLOS IN ENGINEERING DEPT.
IRRIOATION I�IORST CONDITION
'A'
STATIC PRESSURE.- 69.77 PSI 0 1608
ELEV.
VALVE.• A/74 GPM: 26
Z
>Cd
SIZE ITEM
PS!
�z
1 1/2WATER METER
7.4
Qw
1 1/2" BACKFLOW DEVICE
72.0
Za
2" GATE VALVE
1.2
0,,�
2 1/2" CLASS 315 MAINLINE 2600'
6.0
�h
7" 1/2" REMOTE CONTROL VALVE
3.6
PVC LATERAL LINES
4.8
�
ELEVATION LOSS +28'
5.8
TOTAL SYSTEM LOSS
34.8
109' RESIDUAL PSI
3.4
IRRIGATION HEAD PRESSURE
30.00
�QO�
TOTAL SYSTEM LOSS
67.8
a
AVAILABLE PRESSURE
69.71
PSI
RESIDUAL PSI
+1.97
PSI
/_ STRIP WIRES APPROX. 5/8- FROM ENDS
STEP 1
TWIST CONNECTOR UNTIL WIRE END REACHES BOTTOM
STEP 2
MIX CONTENTS OF SEALING PACK, CUT 1/2 OFF
END OF PACK AND INSERT CONNECTOR TO
OPPOSITE END
STEP 3
WRAP OPEN END OF SEALINGPACK WITH
TAPE. ALLOW TO SET UNTIL RESIN JELLS
STEP 4
"SCOTCH" SEALING PACK
WIRE CONNECTION
CITY OF FONTANA
IRRIGATION CONTROLLER STANDARD
FOR COMMUNITY FACILITIES DISTRICTS
(CFD'S)
1. Toro Sentinel Model #SSAK48PS 16NS 113 48 station
field satellite controller,
2. Mount in Strong Box Model No. SB-24SS/ 120V.
(Stainless Steel)
3. Provide ground rod and surge protection for each
satellite controller.
Contact: MIKE DOB IS
TURF STAR
(619) 520-6181
(619) 793-3999 (Pager)
(800) 774-8573 (Main Office)
Park and Landscape Development Section, Engineering Division
Community Development Department, City of Fontana (6/26/04)
PROVIDE 20 AMP -
2 POLE BREAKER
FOR NEW PUMPS
WHERE APPLICABLE
iRRIG.
CONT
50 A
2P
120/240
0 3W
12 CIR
PANEL
r---1
FINISHED GRADE
•• •�4C-
#4
�..:r..
a
REBS
iYP.
GROUND FORELECTRICAL
IRRIGATION CONTROL
BOARD
M ETER
NOTE:
ALL POWER WIRES, GROUND WIRES ETC. SHALL BE
SEPARATELY SLEEVED AND SWEPT THROUGH
INCLOSED PAD WITH SCH 40 RIGID CONDUIT
SIZE OF EQUIPMENT = 46"W X 18"0 X 54" HIGH
AND
SIZE OF CONC. SLAB = 52'W X 24"D X 8" THICK
W/J4 REBARS AT 12. O.C. TYP
8' DIA. X 12- D.
BOTTOMLESS GROUND WELL
WITH PARKWAY COVER,
FILL WITH PEA GRAVEL
5/8 -DIA X 10` DRIVEN GROUND
ROD PER ARTICLE 250-81
OF 1990 NEC
GENERAL NOTES:
FLOW SENSOR MASTER VALVE
CONTROL PROVIDE 100A METER AND 5QA/2P MAIN C/B WHERE INDICATED
PUMP CONDUCTORS CONCRETE ON DRAWINGS
TEMP LA EXTRA MOUNTING PROVIDE PANELBOARD WHERE INDICATED ON DRAWINGS.
SIGNAL
POWER PROVIDE IRRIGATION CONTROLLER CABINET WHERE INDICATED
ON DRAWINGS.
TERMINATE AT EXISTiON HANDHOLE PER S.C.E. COMPANY REQ.
VERIFY ENACT LOCATION AND TERMINATION REQ. WITH S.C.E. CO.
CONDUIT FOR PRIOR TO TRENCHING
GROUND ROD
INSTALLATION CONDUIT AND CONDUCTOR SIZES ARE BASED ON NONMETALLEC CONDUIT
2 EXTRA 1" CONDUITS AND COPPER CONDUCTORS WITH TYPE-THHN/THWN- INSULATION.
EXTRA
24- l i EXACT LOCKnON OF CONTROLLER SHALL BE AGREED
UPON BY EDISON, C11Y LANDSCAPE INSPECTOR AND
�- i F's
❑ CONTRACTOR PRIOR TO ANY TRENCHING OR
iMETER FACESWIRE PLACEMENT
I I I I STREET
1 I
I r-'
e I
I
I
I
12N
STRONG eOX
MODEL NO. S8- 24SS/120V
RAIN SKUTOFF
DEVICE -
SEE LEGEND
a
$cr SWEEP CONDUIT FOR
SWEEP CONDUIT FOR E� CONS OLLER
CONTROLLER
WARES
END VIEW FRONT VIEW
NTS NTS
CONTROLLER
ENCLOSURE
!C4o0sco
$2 CITY OF FONTANA
t 2 j4 Vol
�� LANDSCAPE PLANS
� 27y�
BE/NG/LH SUMMIT AVENUE(NORTH SIDE} As SHOWN
rccrr n BVi DAM
° h b o ` �Q' RP 07/13/05
WE
�%�• k, o�z CHEM]) BYl AWOVU BY,� DWG. Mi 5
of CA�-RP -�-�.�. � UATE, r393,
r-eir2 my mwzm r:.C.E. 511 EXP BATE 14
O
DNM CHK
DATE 07-13-05
JOB * 05-028
H
Z
>Cd
�
W
�z
w
Z
Qw
Za
Z
0,,�
�h
o
C)
�
o0
�QO�
a
O
DNM CHK
DATE 07-13-05
JOB * 05-028
W
�z
w
Z
Qw
Za
Z
0,,�
�h
o
O
DNM CHK
DATE 07-13-05
JOB * 05-028