Loading...
HomeMy WebLinkAbout3929-173" BACK FILL COMPACTED TO j // UIN. COVER 90% WITH CLEAN \\/\ SOIL WITHOUT REQUIREMENTS. OERIS. ` SEE TABLE CABLE OR CONDUIT CLEANSAND \� LIGHTING FIXTURE SCHEDULE DIRECT BURIAL NONMETALLIC RACEWAYS WIRING METHOD CABLES OR LISTED FOR DIRECT BURIAL ND WATT8 TYPE WITHOUT CONCRETE 'ENCASEMENT X 1.25 WATT. OR OTHER APPROVED RACEWAYS ALL LOCATIONS NOT TREE UPUGHT 36 1 32 PL AT GRADE TABLE 300-5 UL WET LISTED . 1711 IN TRENCH BELOW 2' 'I8 12 THICK CONCREET OR 875 EQUIVALENT cALCb -AMPERES UNDER A BUILDING ORGATECH OMEGALUX # 12-132TR-SGA-NFU . 0. UNDER STREETS, HIGHWAYS 24 24 ROADS. ALLEYS, DRIVEWAYS, DECORATIVE PILASTER UGHT 120 1 100 MH TALL 'PILASTER ` D UL WET LISTED VERIFY fm-i HEIGHT w'� WfARCHIIECT NERI MENSOLA 4083,001 O STREET UGHT A LIGHT FIXTURE CALL OUT. "A" INDICATES FIXTURE TYPE, "1007' INDICATES WATTAGE A-1,3,5 HOME RUN TO PANEL LETTER DESIGNATES PANEL, NUMERALS DESIGNATE CIRCUITS. WIRING RUN CONCEALED IN WALL OR ABOVE FINISHED CEILING OR AS NOTED. -- WIRING RUN UNDER FLOOR, OR UNDERGROUND. MINIMUM COVER'. REQUIREMENTS JUN CTIO OX OR PULL OX (IN. INCHES) .X. - 0-600 VOLTS, NEC TABLE 3U0.-5 (PARTIAL) ELECTRICAL SERVICE PEDESTAL LOCATION OF DIRECT BURIAL NONMETALLIC RACEWAYS WIRING METHOD CABLES OR LISTED FOR DIRECT BURIAL OR CIRCUIT CONDUCTORS WITHOUT CONCRETE 'ENCASEMENT X 1.25 0 OR OTHER APPROVED RACEWAYS ALL LOCATIONS NOT 24 18 SPECIFIED IN NEC 0 NG TYPE LOADS 1.00 TABLE 300-5 -0 . 1711 IN TRENCH BELOW 2' 'I8 12 THICK CONCREET OR 875 EQUIVALENT cALCb -AMPERES UNDER A BUILDING 0 . 0. UNDER STREETS, HIGHWAYS 24 24 ROADS. ALLEYS, DRIVEWAYS, AND PARKING LOTS �WWW 1. COORDINATE ELECTRICAL INSPECTIONS WITH SENIOR INSPECTOR, ERIC CARREON, WHEN REQUESTING INSPECTIONS ON THE INSPECTION REQUEST LINE- AT 591-9898_ 2. PROVIDE WORKING CLEARANCES AT ALL EQUIPMENT. -NEC ART. 110•-26. 3. GROUNDING ELECTRODE SYSTEM SHALL COMPLY WITH NEC 250-50. 4. GROUNDING ELECTRODE CONDUCTOR INSTALLATION SHALL COMPLY WITH NEC 250-64. 5. GROUNDING ELECTRODE CONDUCTOR ENCLOSURE SHALL COMPLY WITH NEC 250-64(E). G. GROUNDING ELECTRODE CONDUCTOR -CONNECTION TO THE ELECTRODE SHALL COMPLY WITH NEC 250-70. E-0.1 SYMBOL UST, FIXTURE SCHEDULE, SINGLE LINE DIAGRAM & DETAILS E-1 ELECTRICAL LIGHTING PLAN 7. GROUNDING EL:ECTROD E SYSTEM EOR SEPARATE STRUCTURES SHAH HE IN STALLED PER NEC 250- 32(D}. TOTS 8. EQUIPMENT TO BE FULLY OR SERIES RATED FOR THE AVAILABLE FAULT CURRENT. NEC 110-9. 9. TORQUING OF TERMINATIONS SHALL BE IN ACCORDANCE WITH THE EQUIPMENT LABEL AND PROOF OF TORQUE IS REQUIRED PRIOR TO FINAL. NEC ART. 110-3(8). LOAD BREiQDOWN - -- - VA ICONTINUOU$ LOAD X 1.25 675 700 LARGEST MOTOR X 1.25 0 0 CEPTACLE LOAD e. 1 . • . 4 rl- .,11 Z71N Ir • �' 0 NG TYPE LOADS 1.00 0 -0 . 1711 • '' • 0 0 sw 875 700 cALCb -AMPERES 3,6 Now �WWW D v, fm-i w'� � � 1� � m a - �7 � 01 m Ill�■i� Ilio IIIA I� E-0.1 SYMBOL UST, FIXTURE SCHEDULE, SINGLE LINE DIAGRAM & DETAILS E-1 ELECTRICAL LIGHTING PLAN 7. GROUNDING EL:ECTROD E SYSTEM EOR SEPARATE STRUCTURES SHAH HE IN STALLED PER NEC 250- 32(D}. TOTS 8. EQUIPMENT TO BE FULLY OR SERIES RATED FOR THE AVAILABLE FAULT CURRENT. NEC 110-9. 9. TORQUING OF TERMINATIONS SHALL BE IN ACCORDANCE WITH THE EQUIPMENT LABEL AND PROOF OF TORQUE IS REQUIRED PRIOR TO FINAL. NEC ART. 110-3(8). LOAD BREiQDOWN OF VA4F VA ICONTINUOU$ LOAD X 1.25 675 700 LARGEST MOTOR X 1.25 0 0 CEPTACLE LOAD X NEC 0 0 0 NG TYPE LOADS 1.00 0 -0 OTHER LOADS 1.00 0 0 sw 875 700 cALCb -AMPERES 3,6 NOTES L -1 Trim VIA TIME VIA LIGHYING CONDWILERL UGHMNG it]RECEPTACLELOAD .4 IrlLARGEST MOTOR 0 N 1 _ - N -1 10. A NEUTRAL FAULT TEST IS REQUIRED PRIOR TO FINAL. NEC ART. 250-24(A)(5). 11. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY AN APPROVED TESTING :AGENCY. 12. PROVIDE AN EQUIPMENT GROUNDING CONDUCTOR FOR ALL CIRCUITS PER NEC 250-110 AND 250-118. 13. BONDING SHALL COMPLY WITH NEC 250, PART E. 14. SEPARATE PERMITS REQUIRED FOR ELECTRIC SIGNS AND FIRE ALARM SYSTEMS. 15. METAL CABLE SLEEVES SHALL HAVE FITTINGS OR BUSHINGS TO PROTECT THE CABLE. NEC 300-4. 16. CONDUIT BURIAL DEPTH SHALL BE PER NEC TABLE 300-5. STRONG BOX ELECTRICAL PEDESTAL - MODEL ,SSB-24SS-120/24OV-100AMP LOAD PER CITY STANDARDS PHOTO -CELL 24s' 25" FRONT MIN. 36" FRONT CLEARANCE _ MIN. 36 FRONT & BACK r I CLEARANCE SCALE: OF METER I I FRONT & METER PEDESTAL - - BACK OF NOTES N.T.S. I METER I PEDESTAL I ELECTRIC SERVICE PEDESTAL t; M 1 So - - - - - - 120/24OV.9 10, 3W 100 AMPS MAIN STRONG BOX SB- 24SS-120 240 VOLT 48' PHOTOCELL _j GFI RECEPACLE i L J G.F.I. tj CONVENIENCE M 1 ODAe RECEPTACLE # 2P NOTES. 1. SERIES CONNECTED RATING OF I BREAKERS MAY BE USED. ALL I 1 DDA BREAKERS MUST BE SAME I PANEL ES :: : '• ; •' .,. i. 'f •:•:� a•4. •.' : B�M[,LG lA. LCTR1CALUG MANUFACTURER AND U.L. LISTED, C;1w PROVIDE CONCRETE SERIES CONNECTED SHORT CIRCUIT Ri .•.` ._ •" '� •.. „ :' FOUNDATION(2800-28 DAYS) AND • RATING FOR THAT VOLTAGE` ..Y• •-`•: _ .-.• • :y : - •r° .''`:;�... A CAUFOi�itA CORPORAVON Mi ': ;Y''•. •;"'::• •.. • .:. ';. , + . 4', ' ~'- ' . PER REQUIREMENTS OF MFR VERIFY r 125 E e strep, SuRe 150 �., ',�,. •';•- .. R ,:� EXACT SIZE OF FOUNDATION WITH ° � Cato kiim. CA 92M2. -FIELD MARKED ON ALL EQUIPMENT, � MANUFACTURER AND STRUCTURAL F7144� ��' SHALL READ CAUTION SERIES RATED CHRIS BMSKOR�� sss-3z� 11 ENGINEER PRIOR TO ROUGH -IN. 'MM RECMD DOCIUK9is ARE C FLES As ss�mEv (1) 2 C. TO SYSTEM 42,ODOA AVAILABLE PROVIDE PAD MOUNTED BASE WITH �T��W OF � �T AN U6 ELECTRIC PULL BOX INDENTIFIED REPLACEMENT SERVICE CONDUIT 1 C. FUTURE -REFER TOINSCOWIM BE ANCHOR BOLTS EMBEDDED IN � CM� � IS � COMPONENT REQUIRED, AS REQUIRED PLANS FOR QTY. ��TANr AAFTER THE � +� � � � PART � � CONSULTANT'S CONCRETE SUPPLIED BY PEDESTAL FOR �� � PG" �` BE°°`��"�'D --� TTED MANUFACTURER. B �+,+' Mair Fir ocm+r Pa�r LAW, TO rroa94FY AND HOLD THE OOliS[�TAIiT KAMUSS FROM ANY MWAM uANUTY OR COST. R CLUMG REAS0NA8LE ATTORNEYS FEES AND CSS OF WDIS& AWS04 FROM ANY REUSE OR HODI"MON OF M PLANS AND SPECIF"T" FROM OR 7MMM •nom CLIENT VATIOUT 1W PIMOR *RMEN AUTHOR¢AYM OF W CONSULTA1114r. 1W 001114SULTANT MMMS NO WMMMIM STS" S'INGLE SCALE: �� SCALE: P °R .°IN NO�T� BEs�R�UM" FOR ANY LM OF PRWT OR MY DMA & M1 PEDESTAL ELEVATION N.T.S. N.T.S. I T -r- A P IE Landscape Architecture and Planning 319.5-8 Airport Loop Drive Costa Mesa, CA 92626 RIchond P*Nmmv^ Lk m CA -#7M (949) 644-9370 (714) 210-3140 FAX REVISION IT FIXTURES 8-16-0 VD/ 14,. o W � H zau vii W A Z 0 U Now �WWW D v, fm-i w'�