HomeMy WebLinkAbout3929-7IRRIGATION LEGEND
(CONTRACTOR TO DECIDE IN FIELD WHICH BUBBLER TO INSTALL)
CONTRACTOR MUST USE TORO 570 ADJUSTABLE ARC NOZZLES OR 570 V-15
NOZZLES TO AVOID OVERSPRAY AND INSURE FULL COVERAGE,
THE CONTRACTOR IS REQUIRED TO USE 57OZ-COM (CHECK-O-MATIC)
POP-UP BODY'S ON ANY HEADS ON A SYSTEM WITH Y OR GREATER THAN
ELEVATION CHANGE- OR AS NEEDED IN FIELD.
THE 8' SPRAY HEADS MAY BE SUBSTITUTED WITH 10' NOZZLES AS REQUIRED IN
THE FIELD. ANY HEADS THE NEED A REDUCTION OF MORE THAN 50% OF THE
LISTED SPRAY PATTERN WILL REQUIRE TORO PCD SCREENS.
1 112" WATER METER - REFER TO CIVIL PLAN 1
® 1 112" FEBCO 825Y REDUCED PRESSURE BACKFLOW PREVENTER W12" WYE -STRAINER 1
- SEE DETAILS
NIBCO BRASS BALL VALVE (LINE SIZE) T-585-70 (3/4"-2") / T-580-70-66 (2-314"-3") 5
SUPERIOR 950 DW SERIES REMOTE CONTROL VALVE - SIZES INDICATED 25
IRRIGATION NOTES
DIAGRAMMATIC PLAN
THIS SYSTEM IS DIAGRAMMATIC. ALL PIPE, VALVES, ETC. SHOWN WITHIN PAVED
AREAS ARE FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED IN
PLANTING AREAS AND JOINT TRENCHES WHEREVER POSSIBLE.
SPRINKLER ADJUSTMENT REQUIRED
THE IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLER HEADS
FOR OPTIMUM PERFORMANCE AND PREVENT OVERSPRAY ONTO WALKS AND
ROADWAYS AS MUCH AS POSSIBLE. THIS SHALL INCLUDE SELECTING THE BEST
DEGREE OF ARC TO FIT THE EXISTING SITE CONDITIONS. CONTRACTOR TO USE
PRESSURE COMPENSATING SCREENS WHEN RADIUS IS REDUCED MORE THAN FIFTY
PERCENT (50%).
FIELD CONDITIONS
DO NOT WILLFULLY INSTALL THE SPRINKLER SYSTEM AS INDICATED ON THE
DRAWINGS WHEN IT IS OBVIOUS IN THE FIELD THAT UNKNOWN OBSTRUCTIONS OR
GRADE DIFFERENCES EXIST AND SHOULD BE BROUGHT TO THE ATTENTION OF THE
CONTRACTING OFFICER. IN THE EVENT THAT THIS NOTIFICATION IS
NOT PERFORMED, THE CONTRACTOR MUST ASSUME FULL RESPONSIBILITY FOR ANY
REVISIONS REQUIRED.
SWING JOINTS
INSTALL ALL HEADS WITH DOUBLE OR TRIPLE SWING .POINTS, USING STREET ELLS,
AS PER DETAII.,.
MINIMUM PRESSURE AND MAXIMUM GALLONS REQUIRED
THE SPRINKLER SYSTEM DESIGN IS BASED ON A MINIMUM OPERATIONAL PRESSURE
AND A MAXIMUM DEMAND AT THE POINT OF CONNECTION, AS NOTED ON THE PLAN,
BEFORE INSTALLING THE SYSTEM, CHECK POINT OF CONNECTION AND IMMEDIATELY
NOTIFY CONTRACTING OFFICER IF PRESSURE IS NOT AS NOTED OR THE REQUIRED
GALLONS PER MINUTE IS NOT AVAILABLE.
WATER LINE UNDER PAVING
ALL MAINLINE UNDER PAVING SHALL BE INSTALLED 24" DEEP. ALL LATERAL LINES
UNDER PAVING SHALL BE SCH 40 PVC AND INSTALLED 24" DEEP.
SYSTEM COVERAGE
THE IRRIGATION CONTRACTOR IS TO ADJUST HEAD LOCATIONS IN THE FIELD IN
ORDER TO GUARANTEE 100% COVERAGE, CONTRACTOR TO CONTACT THE
CONTRACTING OFFICER PRIOR TO ANY MAJOR CHANGE(S) RESULTING IN
ADDITIONAL COST TO THE OWNER.
IRRIGATION DESIGN CRITERIA
Name of Water Supplier: Fontana Water District 3/04105
Pressure Given By: Jack Swe @ Fontana Water Distract (626) 448-6183
HGL - 1812 HIGH -361 LOW
ZONE: Tank F46
HIGHEST ELEVATION ON THIS SYSTEM 1647.69
LOWEST ELEVATION ON THIS SYSTEM 1610.6
WATER METER ELEVATION 1632.44
Contractor shall verify the static water pressure with supplier
prior to installation. If different from PSI noted above, Contractor
to notify Owner for instructions. Failure to do so will result
in contractor being responsible for changes that might occur.
Underground Service Alert
SYMBOL DESCRIPTON
'DATA INDUSTRIAL'- HFSM-1.5 FLOW SENSOR
RAINBIRD QUICK COUPLER 33 DLRC - Locate in a 10" round lockable plastic valve box
@ 150' o.c. maximum. Support with a rebar stake and two house clamps
each.
AUTOMATIC CONTROLLER LOCATION - SEE CONTROLLER NOTE ON PLAN.
Provide controller charts per City requirements.
Contractor to also install a Rainguard moisture sensor @ the controller. Locate
in a vandal resistant area free from overhead obstruction and outside of the
irrigation spray pattern.
-- - - MAINLINE - SEE DETAIL FOR INSTALLATION DEPTHS. - SIZES INDICATED.
Mainlines (pressurized) 1112 inch and smaller shall be Schedule 40 solvent -weld P.V.G.
Mainlines (pressurized) 2 inch through 3 inch shall be Class 315 solvent -weld P.V.C.
CONTRACTOR TO USE INSTALL THRUST BLOCKS TO 2" MAINLINE,
PVC SCH 40 LATERAL LINE- 12" COVER IN PLANTING AREAS.
PVC SCHED. 40- 24" COVER UNDER PAVING
- -- WIRE SLEEVES - WIRE CONDUIT TO BE SCH 40 GRAY PVC PIPE, ( LATERAL AND
MAINLINE PIPE RUNS TO BE INSTALLED IN SEPERATE SLEEVES.)
- WIRE SLEEVES, MUST BE OVERSIZED LEAVING AMPLE ROOM FOR FOR
FUTURE VIVRE ADDITIONS OR REPAIRS, 2X THE DIA OF THE SLEEVE CONTENTS
- - - - - - - - PVC SCH 40 MAIN AND LATERAL LINE SLEEVE 2x DIA. OF PIPE ENCASED. - PROVIDE
- - - - - - - - SLEEVES UNDER HARDSCAPE (CONCRETE / ASPHALT IN EXCESS OF 4' WIDE).
INDICATES STATION NUMBER
/-X-*K x INDICATES CONTROLLER
INDICATES GPM
INDICATES VALVE SIZE
PRESSURE LOSS CALCULATIONS
SYMBOL
MFG. MODEL NO.
DESCRIPTON RAD.
GPM
PSI
QTY
iR
TORO
5702-PRX-12P-COM-2SST
TREE BUBBLER
2X6'
.09
30
11
di
RAINBIRD
1812 -SAM -PRS -MPR -NP -5Q
QUARTER SPRAY HEAD
5'
.10
30
ELEVATION CHANGE (UP GRADE -15')
❑
RAINBIRD
1812 -SAM -PRS -MPR -NP -5H
HALF SPRAY HEAD
5'
2.0
30
DESIGN PRESSURE REQUIRED
4
RAINBIRD
1812 -SAM -PRS -MPR -NP -8Q
QUARTER SPRAY HEAD
8'
.26
30
PRIOR TO TRENCHING
®
RAiNBIRD
1812 -SAM -PRS -MPR -NP -8H
HALF SPRAY HEAD
8'
.52
30
2 EXTRA 1" CONDUITS
Q
RAINBIRD
1812 -SAM -PRS -MPR -NP -8F
FULL SPRAY HEAD
8'
1.05
30
z 4"
6
RAINBIRD
1812 -SAM -PRS -MPR -NP -12Q
QUARTER SPRAY HEAD
12'
.65
30
549
%
RAINBIRD
1812 -SAM -PRS -MPR -NP -12H
HALF SPRAY HEAD
12'
1.3
30
r�
Q�
RAINBIRD
1812 -SAM -PRS -MPR -NP -12F
FULL SPRAY HEAD
12'
2.6
30
+�
RAINBIRD
1812 -SAM -PRS -MPR -NP -15Q
QUARTER SPRAY HEAD
15'
,92
30
O
RAINBIRD
1812 -SAM -PRS -MPR -NP -15H
HALF SPRAY HEAD
15'
1.85
30
G
RAINBIRD
1812 -SAM -PRS -MPR -NP -15F
FULL SPRAY HEAD
15'
3.7
30
RAINBIRD
1806 -SAM -PRS -MPR -NP -8Q
QUARTER SPRAY HEAD
8'
.26
30
RAINBIRD
1806 -SAM -PRS -MPR -NP -8H
HALF SPRAY HEAD
8'
.52
30
�I
RAINBIRD
1806 -SAM -PRS -MPR -NP -8F
FULL SPRAY HEAD
8'
1.05
30
'�►
RAIN BIRD
1806 -SAM -PRS -MPR -NP -12Q
QUARTER SPRAY HEAD
12'
.65
30
v
RAIN BIRD
1806 -SAM -PRS -MPR -NP -12H
HALF SPRAY HEAD
12'
1.3
30
RAIN BIRD
1806 -SAM -PRS -MPR -NP -12F
FULL SPRAY HEAD
12'
2.6
30
236
J
RAIN BIRD
1806 -SAM -PRS -MPR NP -15Q
QUARTER SPRAY HEAD
15'
.92
30
V
RAIN BIRD
1806 -SAM -PRS -MPR -NP -15H
HALF SPRAY HEAD
15'
1.85
30
RAIN BIRD
1806 -SAM -PRS -MPR -NP -15F
FULL SPRAY HEAD
15'
3.7
30
®
RAINBIRD
1806-SAM-PRS-MPR-NP-I5RCS115LCS
END SPRAY HEAD
4X15'
.61
30
0
RAINBIRD
1806 -SAM -PRS -MPR -NP -15 SST
STRIP SPRAY HEAD
430'
1.21
30
(CONTRACTOR TO DECIDE IN FIELD WHICH BUBBLER TO INSTALL)
CONTRACTOR MUST USE TORO 570 ADJUSTABLE ARC NOZZLES OR 570 V-15
NOZZLES TO AVOID OVERSPRAY AND INSURE FULL COVERAGE,
THE CONTRACTOR IS REQUIRED TO USE 57OZ-COM (CHECK-O-MATIC)
POP-UP BODY'S ON ANY HEADS ON A SYSTEM WITH Y OR GREATER THAN
ELEVATION CHANGE- OR AS NEEDED IN FIELD.
THE 8' SPRAY HEADS MAY BE SUBSTITUTED WITH 10' NOZZLES AS REQUIRED IN
THE FIELD. ANY HEADS THE NEED A REDUCTION OF MORE THAN 50% OF THE
LISTED SPRAY PATTERN WILL REQUIRE TORO PCD SCREENS.
1 112" WATER METER - REFER TO CIVIL PLAN 1
® 1 112" FEBCO 825Y REDUCED PRESSURE BACKFLOW PREVENTER W12" WYE -STRAINER 1
- SEE DETAILS
NIBCO BRASS BALL VALVE (LINE SIZE) T-585-70 (3/4"-2") / T-580-70-66 (2-314"-3") 5
SUPERIOR 950 DW SERIES REMOTE CONTROL VALVE - SIZES INDICATED 25
IRRIGATION NOTES
DIAGRAMMATIC PLAN
THIS SYSTEM IS DIAGRAMMATIC. ALL PIPE, VALVES, ETC. SHOWN WITHIN PAVED
AREAS ARE FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED IN
PLANTING AREAS AND JOINT TRENCHES WHEREVER POSSIBLE.
SPRINKLER ADJUSTMENT REQUIRED
THE IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLER HEADS
FOR OPTIMUM PERFORMANCE AND PREVENT OVERSPRAY ONTO WALKS AND
ROADWAYS AS MUCH AS POSSIBLE. THIS SHALL INCLUDE SELECTING THE BEST
DEGREE OF ARC TO FIT THE EXISTING SITE CONDITIONS. CONTRACTOR TO USE
PRESSURE COMPENSATING SCREENS WHEN RADIUS IS REDUCED MORE THAN FIFTY
PERCENT (50%).
FIELD CONDITIONS
DO NOT WILLFULLY INSTALL THE SPRINKLER SYSTEM AS INDICATED ON THE
DRAWINGS WHEN IT IS OBVIOUS IN THE FIELD THAT UNKNOWN OBSTRUCTIONS OR
GRADE DIFFERENCES EXIST AND SHOULD BE BROUGHT TO THE ATTENTION OF THE
CONTRACTING OFFICER. IN THE EVENT THAT THIS NOTIFICATION IS
NOT PERFORMED, THE CONTRACTOR MUST ASSUME FULL RESPONSIBILITY FOR ANY
REVISIONS REQUIRED.
SWING JOINTS
INSTALL ALL HEADS WITH DOUBLE OR TRIPLE SWING .POINTS, USING STREET ELLS,
AS PER DETAII.,.
MINIMUM PRESSURE AND MAXIMUM GALLONS REQUIRED
THE SPRINKLER SYSTEM DESIGN IS BASED ON A MINIMUM OPERATIONAL PRESSURE
AND A MAXIMUM DEMAND AT THE POINT OF CONNECTION, AS NOTED ON THE PLAN,
BEFORE INSTALLING THE SYSTEM, CHECK POINT OF CONNECTION AND IMMEDIATELY
NOTIFY CONTRACTING OFFICER IF PRESSURE IS NOT AS NOTED OR THE REQUIRED
GALLONS PER MINUTE IS NOT AVAILABLE.
WATER LINE UNDER PAVING
ALL MAINLINE UNDER PAVING SHALL BE INSTALLED 24" DEEP. ALL LATERAL LINES
UNDER PAVING SHALL BE SCH 40 PVC AND INSTALLED 24" DEEP.
SYSTEM COVERAGE
THE IRRIGATION CONTRACTOR IS TO ADJUST HEAD LOCATIONS IN THE FIELD IN
ORDER TO GUARANTEE 100% COVERAGE, CONTRACTOR TO CONTACT THE
CONTRACTING OFFICER PRIOR TO ANY MAJOR CHANGE(S) RESULTING IN
ADDITIONAL COST TO THE OWNER.
IRRIGATION DESIGN CRITERIA
Name of Water Supplier: Fontana Water District 3/04105
Pressure Given By: Jack Swe @ Fontana Water Distract (626) 448-6183
HGL - 1812 HIGH -361 LOW
ZONE: Tank F46
HIGHEST ELEVATION ON THIS SYSTEM 1647.69
LOWEST ELEVATION ON THIS SYSTEM 1610.6
WATER METER ELEVATION 1632.44
Contractor shall verify the static water pressure with supplier
prior to installation. If different from PSI noted above, Contractor
to notify Owner for instructions. Failure to do so will result
in contractor being responsible for changes that might occur.
Underground Service Alert
SYMBOL DESCRIPTON
'DATA INDUSTRIAL'- HFSM-1.5 FLOW SENSOR
RAINBIRD QUICK COUPLER 33 DLRC - Locate in a 10" round lockable plastic valve box
@ 150' o.c. maximum. Support with a rebar stake and two house clamps
each.
AUTOMATIC CONTROLLER LOCATION - SEE CONTROLLER NOTE ON PLAN.
Provide controller charts per City requirements.
Contractor to also install a Rainguard moisture sensor @ the controller. Locate
in a vandal resistant area free from overhead obstruction and outside of the
irrigation spray pattern.
-- - - MAINLINE - SEE DETAIL FOR INSTALLATION DEPTHS. - SIZES INDICATED.
Mainlines (pressurized) 1112 inch and smaller shall be Schedule 40 solvent -weld P.V.G.
Mainlines (pressurized) 2 inch through 3 inch shall be Class 315 solvent -weld P.V.C.
CONTRACTOR TO USE INSTALL THRUST BLOCKS TO 2" MAINLINE,
PVC SCH 40 LATERAL LINE- 12" COVER IN PLANTING AREAS.
PVC SCHED. 40- 24" COVER UNDER PAVING
- -- WIRE SLEEVES - WIRE CONDUIT TO BE SCH 40 GRAY PVC PIPE, ( LATERAL AND
MAINLINE PIPE RUNS TO BE INSTALLED IN SEPERATE SLEEVES.)
- WIRE SLEEVES, MUST BE OVERSIZED LEAVING AMPLE ROOM FOR FOR
FUTURE VIVRE ADDITIONS OR REPAIRS, 2X THE DIA OF THE SLEEVE CONTENTS
- - - - - - - - PVC SCH 40 MAIN AND LATERAL LINE SLEEVE 2x DIA. OF PIPE ENCASED. - PROVIDE
- - - - - - - - SLEEVES UNDER HARDSCAPE (CONCRETE / ASPHALT IN EXCESS OF 4' WIDE).
INDICATES STATION NUMBER
/-X-*K x INDICATES CONTROLLER
INDICATES GPM
INDICATES VALVE SIZE
PRESSURE LOSS CALCULATIONS
��"�' � ��
VALVE #
D11
GPM
24
WATER METER (1 11211)
1.2
SERVICE LINE
-
GATE VALVES
1.2
BACKFLOW PREVENTER
12.0
MASTER VALVE
1.3
VALVE
3.84
MAINLINE (600' @ 211
)
3.0
LATERAL LINE
4.2
ELEVATION CHANGE (UP GRADE -15')
-6.49
TOTAL PRESSURE LOSS
33.23
10 % RESIDUAL PRESSURE REQUIRED
3.3
MINIMUM OPERATING PRESSURE
30
DESIGN PRESSURE REQUIRED
66.53
AVAILABLE PRESSURE (P.O.C.)
77.9
RESIDUAL PRESSURE REMAINING
+11.37
QTY
1
12
PLAN VIE
1
TYP.. CONCRETE TO REST
AGAINST UNDISTURBED
SOIL
1780' @ 2„
600'@ 1 112"
360'@ 1 1/4"
1000' @ 1"
7000' @ 314"
120'
240'
ELEVATION
TYR. CONCREXE
THRUST BLOCKS
NOTE: THRUST .BLOCKS SHALL 8E INSTALLED IN ACCORDANCE WITH PIPE.
MANUFACTURER'S RECOMMENDATION FOR SIZE OF PIPING REQUIRED:
UTILIZED IN ALL (2 1/2" AND LARGER MAINLINE PIPE)
#3 REBAR TO eE -PLACED AROUND PIPE INTO THRUST BLOCK TYP.
�pflasr � APPROVED 11Y: C" OF FONTANA
C1W ENGINEER DATE: THRUvr BLOCK
RaWAr K WED= ASS EMKY -
1Z/;'10' 9 DAWN 11y.. *IMOMY IZnSTEOr.
�t Cal DATE OF LAST Ii,E'IrlStON: M. PLAN tim San r%WT i nV I
f OF
THRUST BLOCK DETAIL
STRIP WIRES APPROX. 5/8- FROM ENDS
STEP 1
TWIST CONNECTOR UNTIL WIRE END REACHES BOTTOM
STEP 2
MIX CONTENTS OF SEALING PACK, CUT 1/2 OFF
END OF PACK AND INSERT CONNECTOR TO
OPPOSITE END
STEP 3
WRAP OPEN END OF SEALINGPACK WITH
TAPE. ALLOW TO SET UNTIL RESIN JELLS
STEP 4
'SCOTCH" SEALING PACK
WIRE CONNECTION
CITY OF FONTANA
IRRIGATION CONTROLLER STANDARD
FOR COMMUNITY FACILITIES DISTRICTS
(CFD' S)
1. Toro Sentinel Model #SSAK48PS16NS1, 48 station
field satellite controller.
2. Mount in Strong Box Model No. SB-24SS/ 120V.
(Stainless Steel)
3. Provide ground rod and surge protection for each
satellite controller.
Contact: MIKE DOBIS
TURF STAR
(619) 524-6181
(619) 793-3999 (Pager)
(800) 774-8873 (Main Office)
Park and Landscape Development Section, Engineering Division
Community Development Department, City of Fontana (6/26/04)
PROVIDE 20 AIBP
2 POLE BREAKER
FOR NEW PUMPS
WHERE APPLICABLE
IRRIG.
CONT.
50 A
2P
120/240
O 3W
12 CIR
PANEL
r ---i
L --J
FINISHED GRADE 9"
4 REN
- 4u.
GROUND FOR ELECTRICAL k%,=- �==_zp_
IRRIGATION CONTROL
NOTE:
ALL POWER WIRES. GROUND WIRES ETC. SHALL BE
SEPARATELY SLEEVED AND SWEPT THROUGH
ENCLOSED PAD WITH SCH 40 RIGID CONDUIT
SIZE OF EQUIPMENT 4B"W X 18"D X 54" HIGH
AND
SIZE OF CONC. SLAB -• 52V X 24"D X 8' THICK
W/#4 REBARS AT 12. O.C. TYP
s"DAX12"D.
BOTTOMLESS GROUND WELL
WITH PARKWAY COVER,
FILL WITH PEA GRAVEL
5/8"DUI X 10' DRIVEN GROUND
ROD PER ARTICLE 250-81
OF 1990 NEC
METER
I
I I I
I I
� I
I
I
I
I
I
I
SWEEP
��"�' � ��
µ'Vi -+ e•
FOR
CONTROLLER
a
GENERAL NOTES:
FLOW SENSOR
MASTER VALVE
NTS
W
CONTROL
PROVIDE 100A METER AND 50A/2P MAIN C/B WHERE INDICATED
PUMCONDUCTORS
A
ON DRAWINGS
o
CONCRETE
TEMPLATE
MOUNTING
EXTRA SLAB
PROVIDE PANELBOARD WHERE INDICATED ON DRAWINGS,
SIG
�
d
w
POWER
U
PROVIDE IRRIGATION CONTROLLER CABINET WHERE INDICATED
y
ON DRAWINGS.
QU
�z
TERMINATE AT EAS710N HANDHOLE. PER S.C.E. COMPANY REQ.
VERIFY EXACT LOCATION AND TERMINATION REQ. WITH S.C.E. CO.
CONDUIT FOR
PRIOR TO TRENCHING
GROUND ROD
INSTALLATION
CONDUIT AND CONDUCTOR SIZES ARE BASED ON NONMETALLEC CONDUIT
2 EXTRA 1" CONDUITS
AND COPPER CONDUCTORS WITH TYPE `THHN/THWN- INSULATION.
EXTRA
to-
I
z 4"
EXACT LOCAT10N OF CONTROLLER SHALL BE AGREED
I
UPON BY EDISON, CITY LANDSCAPE INSPECTOR AND
r�
CONTRACTOR PRIOR TO ANY TRENCHING OR
j i jEiER
FACES
❑
WIRE PLACEMENT
I
STREET
METER
I
I I I
I I
� I
I
I
I
I
I
I
SWEEP
'CONDUIT
ELLS
FOR
CONTROLLER
a
WIRES
END
VIEW
NTS
W
STRONG Box
MODEL NO. SB- 24SS/120V
RAIN SHUTOFF
DEVICE -
SEE LEGEND
12" w �
SWEEP
'fGONDUT FOR
ELLS
OER
�R�LL
a
JOB #
OS -019
FRONT
VIEW
NTs
W
CONTROLLER AND ENCLOSUfVL�
obb
FARE �,� DRAVN BYE
a Call: TOLL FREE
0
1-800 DESUMD Jay,
422-4133
cHEacen BY -
7W WORKING DAYS BEFORE YOU DIG
CITY OF FONTANA
LANDS CAPE FLANS
KNOX AVENUE - PHASE 1 �s SHOWN
DATEi
VEnn - r� I nw�. Noj 7 QQ
CITY ENGINEER R.C.E. 51152 ESD'. DATE 3929 10
�0 %tkDSCApf
y4 G�
2782 vs
DATE
9��• DO*
dF CAS-��((
DWN
CHK
a�U
a
JOB #
OS -019
N
¢'
of 18
W
zr�"j
A
W
W
o
za
Z
0o
a
�
d
w
U
>
QU
�z
�0 %tkDSCApf
y4 G�
2782 vs
DATE
9��• DO*
dF CAS-��((
DWN
CHK
a
JOB #
OS -019
N
¢'
of 18
W
zr�"j
A
W
W
o
za
Z
o�
a
�
d
w
�z
�0 %tkDSCApf
y4 G�
2782 vs
DATE
9��• DO*
dF CAS-��((
DWN
CHK
DATE 07I05/05
JOB #
OS -019
L 6
of 18