Loading...
HomeMy WebLinkAbout3860-7�__j'TRUCTURAL GENERAL NOTES w s POST W U W w 11 1$-oJ> 11 W U W 5034 J.F. 6-06-2005 1"=iP-C V16r. A.*, 319 G 1, WORK PERFORMED SHALL COMPLY WITH THE FOLLOWING: 1.1 ALL STRUCTURAL NOTES, DRAWINGS, AND SPECIFICATIONS, 1.2 CALIFORNIA BUILDING CODE, 2001. 1.3 ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES, ORDINANCES, LAWS, REGULATIONS AND PROTECTIVE COVENANTS GOVERNING THE SITE OF WORK. 1.4 STANDARD SPECIFICATIONS OF ASTM AS NOTED HEREIN AND REQUIRED BY C.B.C. 2001. 2. NOTES AND DETAILS ON STRUCTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES, SPECIFICATIONS, AND TYPICAL DETAILS PROVIDED ON THIS SHEET AND/OR OR SHEET SDT. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT, TYPICAL DETAIL AND GENERAL NOTES ARE MINIMUM REQUIREMENT TO BE USED WHEN CONDITIONS ARE NOT SHOWN OTHERWISE. 3. IN CASE OF CONFLICT , THE MORE STRINGENT REQUIREMENT SHALL GOVERN. 4. ON SITE VERIFICATION OF ALL DIMENSIONS AND COND111ONS SHALL BE RESPONSIBILITY OF THE CONTRACTORS, NOTED DIMENSIONS TAKE PRECEDENT OVER SCALE OF DRAWINGS. ANY DISCREPANCIES SHALL BE REPORTED TO THE OWNER IMMEDIATELY, 5, WE] PEI STRUCTURAL ENGINEERS, INC. (WPSE) OR ARCHITECT OF RECORD IS TO BE NOTIFIED IMMEDIATELY" BY THE CONTRACTOR SHOULD ANY QUESTION OR DISCREPENCY ARISE PERTAINING THE WORKING DRAWINGS AND/OR SPECIFICATIONS. . NO DEVIATIONS FROM THESE REQUIREMENTS AND STRUCTURAL DETAILS SHALL BE MADE WITHOUT THE WRITTEN APPROVAL OF WPSE. APPROVAL BY THE INSPECTOR DOES NOT CONSTITUTE AUTHORITY TO DEVIATE FROM FLANS OR SPECIFICATIONS. 7. THE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION, THE DESIGN, ADEQUACY, AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC., IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR, AND HAS NOT BEEN CONSIDERED BY THE ARCHITECT OR WPSE. OBSERVATION VISITS TO THE SITE BY THE ARCHITECT OR STRUCTURAL ENGINEER SHALL NOT IMPLY THE ASSUMPTION OF ANY RESPONSIBILITY IN THIS REGARD. S. MERE REFERENCE IS MADE TO VARIOUS TEST STANDARDS FOR MATERIALS, SUCH STANDARDS SHALL BE THE LATEST EDITION AND/OR ADDENDUM. 9. CONSTRUCTION MATERIAL SHALL BE SPREAD OUT 1F PLACED ON ROOF. LOAD SHALL NOT EXCEED THE DESIGN DEAD LOAD PER SQUARE FOOT. PROVIDE ADEQUATE SHORING AND/OR BRACING. 10, OWNER SHALL PAY STRUCTURAL ENGINEER FOR STRUCTURAL OBSERVATIONS DURING CONSTRUCTION AS REQUIRED BY BUILDING DEPT. CONCRETE 1„ ALL CONCRETE MATERIALS AND CONSTRUCTION SHALL CONFORM TO CHAPTER 19, C.B.C. 2, ALL CEMENT SHALL CONFORM TO A.S.T.M. C--150, TYPE I OR It, LOW ALKALI. 3. FINE AND COARSE AGGREGATE SHALL CONFORM TO A.S.T.M. C-33 FOR STANDARD WEIGHT CONCRETE, WITH THE AVERAGE DRYING SHRINKAGE AT 26 -DAY'S OF DRYING NOT EXCEEDING 0.047 MAX AGGREGATE SIZE SHALL BE 3/4. OF MINIMUM CLEAR SPACING BETWEEN BARS. 4, USE TYPE V CEMENT FOR CONCRETE IN CONTACT WITH SOILS. 5. CONCRETE SHALL BE PROPORTIONED TO PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF .2300 PSI 0 28 DAYS, UNLESS NOTED OTHERWISE, 6. ALL REINFORCING, ANCHOR BOLTS, DOWELS, HOLDOWNS, AND OTHER INSERTS SHALL BE SECURED IN POSITION AND APPROVED BY THE LOCAL BUILDING OFFICAL PRIOR TO POURING CONCRETE. 7. CONCRETE SHALL BE CURED BY KEEPING CONTINOUSLY WET FOR 10 -DAYS OR BY AN APPROVED CURING COMPOUND. 3. REFER TO ARCHITECTURAL MECHANICAL,,ELECTRICAL AND PLUMBING DRAWINGS FOR MISCELLANEOUS ITEMS TO BE CAST IN CONCRETE, AND FOR LOCATIONS OF FLOOR FINISHES, DEPRESSION, PITS, ITC, 9. MINIMUM COVER ON NON --PRESTRESSED STEEL. CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH EXPOSED TO EARTH OR WEATHER BARS OR SMALLER ............................... . . .....1 1/2- /2 - BARS OR LARGER ........................ .........2 - #6 BARS NOT EXPOSED TO WEATHER OR GROUND CONTACT SLABS, WALLS, OR JOISTS 11 BARS ORSMALLER ..................................... 3/4- 14 AND #18 BARS.........................................1 1/2 - BEAMS, GIRDERS, OR COLUMNS ... . .......................... 1 1/2" 10. MINIMUM HORIZONTAL CLEAR DISTANCE BETWEEN BARS IN A LAYER BEAMS; THE MAXIMUM OF ONE BARS DIAMETER OR .........110 WALLS: THE MAXIMUM OF ONE BARS DIAMETER OR ........1- 11. MINIMUM HORIZONTAL CLEAR DISTANCE BETWEEN BARS IN ADJACENT LAYER BEAMS: .................................................. REINFORCING STEEL 1. ALL REINFORCING STEEL BARS SHALL BE A.S.T.M. A--615, GRADE 40 FOR 3 & #4, AND GRACIE 60 FOR LARGER, U.N.O. 2. ALL REINFORCING TO BE WELDED SHALL BE OFA WELDABI E GRADE SUCH AS ASTM A706. 3. USE LOW HYDROGEN ELECTRODES, GRADE E-70 FOR WELDED REINFORCING BARS. 4. ALL REINFORCING SHALL BE SECURELY TIED AND BRACED IN PLACE PRIOR TO POURING CONCRETE OR PLACING MASONRY. 5. REINFORCING MARS MARKED CONTINOUS SHALL BE SPLICED WITH A MINIMUM LAP OF 46 BAR DIAMETERS IN MASONRY AND PER SCHEDULE FOLLOWING FOR CONCRETE. MIN. LAP SPLICE LENGTH FOR REBAR IN CONCRETE (INCH) 1. FOR ALL DEFORMED BARS EXCEPT TOP BARS. CONCRETE STRENGTH (PSI) BAR NO. 2000 2500 3000 3500 4000 5000 #3 20 16 16 16 16 16 27 24 22 20 19 17 33 30 27 25 24 21 40 36 32 30 26 25 46 41 38 35 33 29 55 49 45 42 39 35 9 70 62 57 53 49 4.4 10 86 77 70 65 61 55 11 104 93 65 79 74 66 2. FOR ALL DEFORMED TOP BARS ONLY: CONCRETE STRENGTH (PSI) BAR NO. 2000 2500 3000 3500 4000 5000 3 26 23 21 21 21 21 4 34 31 26 26 24 22 43 36 35 33 31 27 6 51 46 42 39 37 33 .7 60 54 49 45 43 36 S 72 54 59 54 51 46 9 91 61 74 69 64 57 10 114 100 91 65 79 71 11 135 1.21 110 102 96 66 TOP REINF. REFERS TO REINF. STEEL SO PLACED THAT MORE THAN 12" OF FRESH CONC. IS CAST IN THE MEMBER BELOW THE REINFORCEMENT w s POST W U W w 11 1$-oJ> 11 W U W 5034 J.F. 6-06-2005 1"=iP-C V16r. A.*, 319 G