PLAN 245.
3683 AR
P,0,C,
21/2 2" 11/21411/211
m ®
ti
M
POINT OF CONNECTION: 'A'
1 1/2" WATER METER, REFER TO CIVIL PLANS. CONTRACTOR
TO INSTALL A 1 1/2" FEBCO 825Y REDUCED PRESSURE TYPE
BACKFLOW PREVENTER AND LOCATE IN A LEMEUR VANDAL -
RESISTANT STEEL MESH ENCLOSURE.
COORDINATE LOCATION WITH CITY INSPECTOR. (SCREEN WITH SHRUBS)
STATIC PRESSURE:
36
PSI
PRESSURE AFTER BOOSTER PUMP:
90.4
PSI
DESIGN PRESSURE:
72.4
PSI
MAXIMUM DEMAND:
36
GPM
CONTROLLER: 'A' (STREETSCAPE)
CONTRACTOR TO INSTALL TORO SSA -K 36 -PSI -6 -N -S-4 CONTROLLER.
CONTROLLER TO BE MUST INCLUDE A RADIO CONTROL AND PHONE
MODEM. COORDINATE LOCATION WITH CITY INSPECTOR.
(VERIFY WITH FIELD INSPECTOR PRIOR TO PURCHASE OR INSTALLATION.)
SEE SITE ELECTRICAL PLANS.
PRESSURE LOSS CALCULATIONS
O
N
VALVE #
A/26
GPM
28
WATER METER (1 1 /2")
1.6
SERVICE LINE
0.02
GATE VALVES
1.4
BACKFLOW PREVENTER
12.0
MASTER VALVE
1.1
VALVE
1.0
MAINLINE (2160' @ 2 1/2")
5.62
LATERAL LINE
4.2
ELEVATION CHANGE (UP GRADE -2T)
11.6
TOTAL PRESSURE LOSS
38.5
10 % RESIDUAL PRESSURE REQUIRED
3.9
MINIMUM OPERATING PRESSURE
30
DESIGN PRESSURE REQUIRED
72.4
AVAILABLE PRESSURE (P.O.C.) (AFTER PUMP)
90.4
(TOTAL BOOST)
54.4
RESIDUAL PRESSURE REMAINING
+18
I
T�
1
IRRIGATION DESIGN CRITERIA
Name of Water Supplier: Fontana Water District 08/18/04
Pressure Given By: MIKE MC GAW (909) 822-2201 - (JOSE)
Pressure Given By: KIETH HOUSTON (626) 448-6183
Static Pressure: 36 PSI @ CURTIS AVE / CATAWBA AVE
( 1561.8 ELEV. )
Contractor shall verify the static water pressure with supplier
prior to installation. If different from PSI noted above, Contractor
to notify Owner for instructions. Failure to do so will result
in contractor being responsible for changes that might occur.
CONTACT: SCOTT CARINGELLA WITH RAIN BIRD@(949) 294-3083 FOR PRICE QUOTATION AND DISTRIBUTION INFORMATION
QUOTE NUMBER & JOB NAME: PS500401178A - Fontana Tract 16539
RAIN BIRD MODEL: GRE10 2
MAXIMUM SYSTEM DEMAND (GPM): 36 gpm
INLET PRESSURE (PSUFEET OF HEAD): 35 psi
PRESSURE SET POINT -DISCHARGE PRESSURE (PSUFEET OF HEAD): 70 psi
PRESSURE BOOST (PSIIFEET OF HEAD): 35 psi
MOTOR HORSE POWER(HP): 1.5hp
MOTOR POWER REQUIRED (PHASENOLTAGE): Single phase/230v
JOB SITE POWER AVAILABLE: Single phase, 230v
CURRENT DRAWN: 11 amps
TRNSFORMER REQUIRED: None
PHASE CONVERTER REQUIRED: None
ENCLOSURE: Aluminum
OPTIONS: Pump Fault Light, Lightning Protection, Larger Switch Panel, Pressure Tank
IRRIGATION DETAILS, NOTES & LEGEND SEE SHEET L-8 & L-9
SCALE
1"-20'
Th. IPo.S�9
w
¢Q�
z
LU
'o UWgE-'d
daUZ
CL QO
�DU
�
O
N
DATE 09/23/04
JOB # 04-042
�
�
00
CIO
Z
^�
rr
O
Qd
�
N
00
rrc�3
V
c-,
W
Cd
W
U
o
c�
00
�.� Vlk-NDSCApf
2782
QW ac CIO
03
q�F Dow
OF Ca��F
D1MN
CHK
DATE 09/23/04
JOB # 04-042
L1 2
OF 14