Loading...
HomeMy WebLinkAbout3758-121 AV 4 2 A 5 ENUEz36 2S 2u T -H 72' MATCH"LINE SEE BELOW LEFT 2416 OF. tT4 PRESSURE LOSS CALCULATIONS V{-lyl VALVE # A/26 GPM 28 WATER METER (1 10) 1.6 SERVICE LINE 0.02 GATE VALVES 1.4 BACKFLOW PREVENTER 12.0 MASTER VALVE 1.1 VALVE 1.0 MAINLINE (2160' @ 2 1/2") 5.62 LATERAL LINE 4.2 ELEVATION CHANGE (UP GRADE -2T) 11.6 TOTAL PRESSURE LOSS 38.5 10 % RESIDUAL PRESSURE REQUIRED 3.9 MINIMUM OPERATING PRESSURE 30 DESIGN PRESSURE REQUIRED 72.4 AVAILABLE PRESSURE (P.O.C.) (AFTER PUMP) 90.4 (TOTAL BOOST) 54.4 RESIDUAL PRESSURE REMAINING +18 i77r : • . u� IRRIGATION DESIGN CRITERIA Name of Water Supplier: Fontana Water District Pressure Given By: MIKE MC GAW (909) 822-2201 - (JOSE) Pressure Given By: KIETH HOUSTON (626) 448-6183 Static Pressure : 36 PSI @ CURTIS AVE / CATAWBA AVE ( 1561.8 ELEV. ) Contractor shall verify the static water pressure with supplier prior to installation. If different from PSI noted above, Contractor to notify Owner for instructions. Failure to do so will result in nnntrar_tnr hainn racr►nncihlrm fnr nhnnnoc +hn+ mink+ ne+e►11r UUM I AU r: scvTT GAKINULL ..A WITN RAIN BIRDL(949) 294-3083 FOR PRICE QUOTATION AND DISTRIBUTION INFORMATION QUOTE NUMBER 81 JOB NAME: PS500401178A - Fontana Tract 16539 RAIN BIRD MODEL: CRE 10 2 MAXIMUM SYSTEM DEMAND (GPM): 36 gpm INLET PRESSURE (PSIIFEET OF HEAD): 35 psi PRESSURE SET POINT -DISCHARGE PRESSURE (PSIIFEET OF HEAD): 70 psi PRESSURE BOOST (PSIIFEET OF HEAD): 35 psi MOTOR HORSE POWER(HP). 1.5hp MOTOR POWER REQUIRED (PHASE/VOLTAGE): Single phase/230v JOB SITE POWER AVAILABLE: Single phase, 230v CURRENT DRAWN: 11 amps TRNSFORMER REQUIRED: None PHASE CONVERTER REQUIRED: None ENCLOSURE: Aluminum OPTIONS: Pump Fault Light, Lightning Protection, Larger Switch Panel, Pressure Tank v • ..rvr ■M.. y. 116V. V1.-VVI\II' 1 V114 IV'►►,%. V{-lyl i -Q1 @ 150' o.c. maximum. Support with a sch 40 pvc pipe stake and two house clamps TORO 570 Z-PRX-I2P-COM-8Q QUARTER SPRAY HEAD 8' .25 30 40 TORO 570 Z-PRX- 1 2P -COM -8H HALF SPRAY HEAD 8' .50 30 ® TORO 570 Z-PRX- I 2P -COM -8F FULL SPRAY HEAD 8' 1.0 30 (i TORO 570 Z-PRX-12P-COM-12Q QUARTER SPRAY HEAD 12' .50 30 O TORO 570 Z-PRX-12P-COM-12H HALF SPRAY HEAD 12' 1.09 30 Q TORO 570 Z-PRX- 1 2P -COM -1 2F FULL SPRAY HEAD 12' 2.19 30 PVC CLASS 200 LATERAL LINE- 12" COVER IN PLANTING AREAS. TORO 570 Z-PRX-12P-COM-15Q QUARTER SPRAY HEAD 15' .85 30 O TORO 570 Z-PRX-12P-COM-15H HALF SPRAY HEAD 15' 1.65 30 @ TORO 570 Z-PRX-12P-COM-15F FULL SPRAY HEAD 15' 3.60 30 C] TORO 570Z-PRX-12P-COM-2SST STRIP SPRAY HEAD 2X6' .09 30 01 TORO 570Z-PRX-12P-COM-4EST END SPRAY HEAD 4X15' .45 30 0 TORO 570Z-PRX-12P-COM-4SST STRIP SPRAY HEAD 4X30' .90 30 TORO 570 Z-PRX-6P-COM-8Q QUARTER SPRAY HEAD 8' .25 30 V TORO 570 Z-PRX-6P-COM-8H HALF SPRAY HEAD 8' .50 30 Q TORO 570 Z-PRX-6P-COM-8F FULL SPRAY HEAD 8' 1.0 30 �I TORO 570 Z-PRX-6P-COM-12Q QUARTER SPRAY HEAD 12' .50 30 TORO 570 Z-PRX 6P -COM -12H HALF SPRAY HEAD 12' 1.09 30 Q TORO 570 Z-PRX-6P-COM-12F FULL SPRAY HEAD 12' 2.19 30 d7 TORO 570 Z-PRX-6P-COM-15Q QUARTER SPRAY HEAD 15' .85 30 �? TORO 570 Z-PRX-6P-COM-15H HALF SPRAY HEAD 15' 1.65 30 @ TORO 570 Z-PRX-6P-COM-15F FULL SPRAY HEAD 15' 3.6 30 ® TORO 570 Z-PRX-6P-SB-2-180-PC2 STREAM BUBBLER 2X6' .09 30 570 Z-PRX-6P-SB-90-PC2 (CONTRACTOR TO DECIDE IN FIELD WHICH BUBBLER TO INSTALL) CONTRACTOR MUST USE TORO 570 ADJUSTABLE ARC NOZZLES OR 570 V-15 NOZZLES TO AVOID OVERSPRAY AND INSURE FULL COVERAGE. THE CONTRACTOR MAY USE STANDARD RISERS IN SHRUB AREAS THAT ARE ADJACENT TO WALLS OR BUILDINGS OR WHERE PEDESTRIAN TRAFFIC WILL NOT OCCUR. THE CONTRACTOR IS REQUIRED TO USE 57OZ-COM (CHECK-O-MATIC) POP-UP BODY'S ON ANY HEADS ON A SYSTEM WITH T OR GREATER THAN ELEVATION CHANGE- OR AS NEEDED IN FIELD. THE 8' SPRAY HEADS MAY BE SUBSTITUTED WITH 10' NOZZLES AS REQUIRED IN THE FIELD. ANY HEADS THE NEED A REDUCTION OF MORE THAN 50% OF THE LISTED SPRAY PATTERN WILL REQUIRE TORO PCD SCREENS. WATER METER - REFER TO CIVIL PLAN 2" FEBCO 825Y REDUCED PRESSURE BACKFLOW PREVENTER W/ 2" WYE -STRAINER - SEE DETAILS IRRIGATION BOOSTER PUMP - SEE PLAN FOR LOCATION SEE DETAIL SHEET FOR NOTES. NIBCO BRASS BALL VALVE (LINE SIZE) T-585-70 (3/4"-2") /T-580-70-66 (2-3/4"-3") SUPERIOR 950 DW SERIES REMOTE CONTROL VALVE - SIZES INDICATED IRRIGATION DETAILS,, NOTES & LEGEND SEE SHEET L-8 & L-9 VLVV1.41 SWIM 1 1/2" GRISWORLD 2230 ( NORMALLY OPEN ) MASTER VALVE. INSTALL DOWNSTREAM FROM FLOW SENSOR. 'DATA INDUSTRIAL'- HFSM-1.5 FLOW SENSOR (� RAINBIRD QUICK COUPLER 33 DLRC - Locate in a 10" round lockable plastic valve box Di47E 09/23/04 @ 150' o.c. maximum. Support with a sch 40 pvc pipe stake and two house clamps L11 each. AUTOMATIC CONTROLLER LOCATION - SEE CONTROLLER NOTE ON PLAN. Provide controller charts per City requirements. Contractor to also install a Rainguard moisture sensor @ the controller. Locate in a vandal resistant area free from overhead obstruction and outside of the irrigation spray pattem. - - -. MAINLINE - SEE DETAIL FOR INSTALLATION DEPTHS. - SIZES INDICATED. d1 O Mainlines (pressurized) 11 /2 inch and smaller shall be Schedule 40 solvent, weld P.V.C. Mainlines (pressurized) 2 inch through 3 inch shall be Class 315 solvent -weld P.V.C. CONTRACTOR TO USE INSTALL THRUST BLOCKS TO 2" MAINLINE, PVC CLASS 200 LATERAL LINE- 12" COVER IN PLANTING AREAS. PVC SCHED. 40- 24" COVER UNDER PAVING r= PVC SCH 40 WIRE SLEEVE. Cn PVC SCH 40 MAIN AND LATERAL LINE SLEEVE 2x DIA. OF PIPE ENCASED. - PROVIDE SLEEVES UNDER HARDSCAPE (CONCRETE / ASPHALT IN EXCESS OF 4' WIDE). NOTE: a * ALL CONTROL WIRE, LATERAL AND MAINLINE PIPE RUNS � TO BE INSTALLED IN SEPERATE SLEEVES. * ALL SLEEVING TO BE SCH. 40 PVC. ° '' SIZING : - WIRE SLEEVES, MUST BE OVERSIZED LEAVING AMPLE ROOM 0 FOR FUTURE WIRE ADDITIONS OR REPAIRS. - PIPE SLEEVING TO BE 2 x DIAMETER OF PIPE ENCASED. 00 INDICATES STATION NUMBER kX INDICATES CONTROLLER INDICATES GPM INDICATES VALVE SIZE SCALE 1'=20" I, 10 1� ® L. 10 ............ I� 1 e 1 1 1 1 1 1 1 1 1 1 1 LANDSCApf 2782 4�G cli WE 9lF Of' CA��F�Q� DWN MmllaRDJ N Di47E 09/23/04 '1OB # 04-042 L11 OF 14 s� d1 O C)cn r= 00 Cn a � � O W ° 0 00 LANDSCApf 2782 4�G cli WE 9lF Of' CA��F�Q� DWN MmllaRDJ CHK Di47E 09/23/04 '1OB # 04-042 L11 OF 14