Loading...
HomeMy WebLinkAbout3134-4BOX TO BE PLACED AT RIGHT ANGLE TO HARDSCAPE EDGE W/ VALVE # ETCHED IN LID 12"X18" PLASTIC BOX AND COVER WITH O PRESSURE REGULATOR IF LOCK TOP REQUIRED. SET AS SHOWN REDUCE PRESSURE CURL TYPE EXPANSION LOOP (MIN.24") ON SITE DRAWING BACKFLOW PREVENTER STRAINER #40 BRASS NIPPLE WATERPROOF WIRE CONNECTION 1 2>>OR MESH MODEL (4 PLACES) HARDSCAPE BRASS ELBOW BRASS ELBOW CHRISTY'S LD TAG (STANDARD) A S ISI O TE D BRASS UNION 1 Q'� VALVE BOX W%LOCK SECURE TO SOLENOID PIGTAIL RELIEF PORT BRASS PIPE (C� FINISH- GRADE 3 BRASS BALL ® BRASS BALL VALVE os�E K Y %18,. VALVE FINISH GRADE 4 RED BLACK BLUE I BRASS PIPE LOCK Box1I-- OF 14 a IRRIGATION CONTROLLER WHITE WIRES• #4 REBAR m (COMMON) 18" 18• r! � - --�-- J'���u - _ BLUE ,.: 4. FOOTING/FOUNDATION Ell 'I 2" MAX. T(� WATERPROOF ALL BRASSSOL N D WIRE CONNECTIONS PRESSURE CONC. STABILIZER PRESSURE GATE VALVE PVC MALE ADAPTOR O F VALVE PVC LI PIPE 1. AS PER STD. SUPPLY LINE (TRUST BLOCK) FRONT SUPPLY LINE (INTAKE) (DISCHARGE) I��N- RESSURE MAINLINE 18 M I UNION CONNECT101 LIN ITTING BLACK MASTER CONTROL _ _ ' �' PEA GRAVEL VALVE BACKFLOW ENCLOSURE , -- 3/4" GRAVEL (SEE NOTE BELOW) p' ,,�, a� (M1N.3 CU. FT.) BRASS ELBOW FLOW SENSOR 6n PVC LINE PIPE PVC SCH. 40 MALE ADAPTOR DIAMETER SAME SIZE :�" :�.,°�•' °•' �''•� :'° °:: 4°` .: BRASS UNION PVC ELBOW (TYP. 2 PLACES) D AS FLOW METER SIZE _ BRASS BALL 1 CU. FT. PEA GRAVEL PVC LINE PIPE S."±; :!`•*'�•a s�'�;�o:• '•`•�•°,••' VALVE 2" x 4" RWD BLOCK COMMON WIRE PVC SUPPLY LINE FITTINGS(SXSXS) MINIMUM DI TANCE DOWNSTREAMP EAN 12„ _i' . #4 REBAR CONTROL WIRE --� 5X DIAMETER OF FLOW METER SIZE 12 MINIMUM DISTANCE UPSTREAM 1OX DIAMETER OF FLOW NOTES: METER SIZE NOTE: BACKFLOW ENCLOSURE,LE MEUR ENI] 1. VALVES ARE TO BE INSTALLED IN SHRUB AREAS UNLESS OTHERWISE NOTED OR EQUAL 24 X60 X36 HIGH 2. WHEN MORE THAN ONE VALVE IS LOCATED IN THE SAME AREA. PROVIDE A SPACE A MIN. OF 3 FT. APART. HINGED AT ONE END SECURE TO 6"X8" FOOTING W/4" J BOLTS 3. USE TEFLON TAPE ON ALL THREADED FITTINGS, (EQUIPMENT TO BE CENTERED INSIDE HOUSING) 4. ONE VALVE PER VALVE BOX uj t�m co)1MOTE K LO) 55A FLOW MET STVALVE 5 5ACKFLO26' 4 CONT L VAL VE a --mh"r= GAT' VAL Ytmm �t FINISHED GRADE NOTE: 6" MIN FROM HARDSCAPES �9 � y 2 4 ALL POWER WIRES, GROUND WIRES ETC. SHALL BE '4.r,: • ZCLEAN BACK FILL SATURATE AND COMPACT TO 90% EXACT LOCATION OF CONTROLLER SHALL BE AGREED SEPARATELY SLEEVED AND SWEPT THROUGH NON PRESSURE LATERAL LINE UPON BY EDISON, CITY LANDSCAPE INSPECTOR AND ENCLOSED PAD WITH SCH 40 RIGID CONDUIT z HA AIN LATERAL LINE CONTRACTOR PRIOR TO ANY TRENCHING OR ALL SLEEVING SHALL BE A MINIMUM OF 18 BELOW � � •,,,�e..., ,� •, � •-• = • •,. ,.::•.p ,:. WIRE PLACEMENT FINISHED GRADE. ALL SLEEVING IS A GRAPHIC 00 NATIVE BACKFILL 2°' MINUS REPRESENTATION OF A TYP. INSTALLATION. �- PRESSURE SUPPLY LINE I I I I IRRIG. NON PRESSURE LATERAL LINE W/SLEEVE 36" CONT, CONTROLL WIRES _ I " -•,':: '�• •'•,� • CLEAN BACKFILL N PRESSURE SUPPLY LINE W/SLEEVE SIZE OF EQUIPMENT 46 W X 18 D X 54 HIGH , - AND `;• .i.;• -* -s .`�. •�.• CONTROL WIRE SLEEVE SIZE OF CONC. SLAB - 52"W X 24"D X 8" THICK - ` '•'s �`:'���` W/#4 KEBABS AT 12" O.C. TYP t•x;••-?•;•• ` `� SAND BACK FILL � i i i �� � i� jai (�iE ;�;... :� •-`•• GENERAL NOTES: 2" MIN PROVIDE 100A METER AND 50A/2P MAIN C/B WHERE INDICATED 6"MIN 6„ FINE GRANULAR MATERIAL WILL BE PLACED ON ALL LINES NO ON DRAWINGS MIN LARGER THAN 1/2" INCH IN SIZE. THIS WILL BE PERMITTED IN THE NOTES: PROVIDE PANELBOARD WHERE INDICATED ON DRAWINGS. 8" DIA, X 12" D. INITIAL BACKFILL MEASURED 6" FROM THE TOP OF PIPE. THE REMAINDER BOTTOMLESS GROUND WELL OF TRENCH CAN BE FILL WITH ROCK SCREENED 2" MINUS. INSTALL CONTROL WIRE SLEEVE ADJACENT TO THE PRESSURE SUPPLY LINE, SIZE PER • ,�_ : •._:�::.== = PROVIDE IRRIGATION CONTROLLER CABINET WHERE INDICATED 99 WITH PARKWAY COVER, SPEC. ALL BACK FILL IS TQ BE SATURATED AND COMPACTED TO 90% • �• • •"`' ON DRAWINGS. FILL WITH PEA GRAVEL ALL SLEEVES TO BE SCH. 40 PVC AND TO BE 2X THE DIAMETER OF THE LINE TO BE INSTALL ALL PVC PIPE WITH LABEL UP. TERMINATE AT EXISTION HANDHOLE. PER S.C.E. COMPANY REQ. _ SLEEVED, � °�`� SNAKE ALL PIPE IN TRENCH. VERIFY EXACT LOCATION AND TERMINATION REQ. WITH S.C.E. CO. • '• a ,'•-"�• ° ; : ; •"�4�s:4 * INCREASE THIS DISTANCE TO 36" WHEN SLEEVING UNDER ROADWAYS AND COMMERCIAL SWEEP CONDUIT FOR PRIOR TO TRENCHING a #4 REBARS BUNDLE AND TAPE ALL CONTROL WIRES AT 10' O.C. TO PRESSURE TRAFFIC WAYS WHEN INSTRUCTED BY INSPECTOR. ELLS CONTROLLER TYP. 5/8"DIA X 10' DRIVEN GROUND SUPPLY LINE AND PROVIDE A SERVICE LOOP AT ALL 90 DEGREE SLEEVES SHALL BE EXTENDED BEYOND HARDSCAPE TO POINTS AS REQUESTED BY WIRES CONDUIT AND CONDUCTOR SIZES ARE BASED ON NONMETALLEC CONDUIT CHANGES IN DIRECTION. INSPECTOR COPPER CONDUCTORS WITH TYPE "THHN/THWN" INSULATION. ROD PER ARTICLE 250-81 "`••?•"' OF 1990 NEC PRESSURE MAIN 2" AND LARGER SHALL BE P.V.C. CLASS 315 4" �•��� ��' IF SLEEVES ARE TO BE USED AT A LATER DATE CONTRACTOR SHALL TAPE ENDS AND �;+�,' 1:; SMALLER THAN 2" SHALL BE P.V.C. SCHEDULE 40, PROVIDE A VERTICAL MARK AT ENDS OF SLEEVING VISIBLE AT GROUND LEVEL. FRONT VIEW --�' CONTRACTOR SHALL PROVIDE SLEEVES OR CONDUIT LINES WHEN TS MAINLINE INSTALLATION IS UNDER ASPHALT OR CONCRETE. CONTRACTOR SHALL PROVIDE 24" INCHES OF COVER OVER PIPE 10 SERVING A DRINKING FOUNTAIN OR PRESSURE MAINLINE 3" AND LARGER. IRRIGATION CONTROL BOARD METER FACES PROVIDE 20 AMP E T RENCH ING F %SLEEVINC STREET 2 POLE BREAKER M FOR NEW PUMPS METER 3 36 WHERE APPLICABLE POP—UP TURF HEAD 1 1/2" STRONG BOX 50 A MODEL N0. SB— 24SS 1 SOV 2P FINISH GRADE WALK OR CURB CONC. WALK 120/240 OR CURB 0 3W 1 1/2" Y2„ 4 a 12 CIR FINISH GRADE I -- '' 1—III III Ili [ I PANEL •; , � . • .III=1 I I ...11 ISI 11 Ill =1 l I ... 111--1 I I ...III^I l lel I �� 10" VALVE BOX MARKED W/ 2" QUICK COUPLER VALVE - HI POP SHRUB HEAD LETTERS READING Q.C. FINISHED GRADE W/ LOCKING BOLT LID { •°;. r :`.; 12" MIN. FROM HARDSCAPE MATERIALS �, _ •�- '• -' FINISH GRADE ... •� , s goo•' ~ - SCH 80 PVC NIPPLE PVC STREET ELLS SWEEP PVC STREET ELL THREADED BOTH ENDS CONDUIT FOR 6„ MIN PEA GRAVEL ELLS CONTROLLER GROUND FOR ELECTRICAL x 4 RWD OR BRICK LATERAL LINE WITH NOTE: BRASS STREET ELL TYP. PVC TEE OR ELL 0 INSTALL 12” SHRUB POP-UP HEAD 1/2" WIRES BASS NIPPLE 6" MIN END VIEW DOUBLE SWING JOINT ABOVE F.G. �: --- 2 EA. PVC STEET ELLS 0 F.G. ---1/2" BELOW WALK OR CURB NTS 3/4 �' 1 #� PVC SHC 40 TEE OR ELL PUMP CONCRETE LATERAL LINE SIZE TO BE NOTED ON PLAN o CHECK VALVE FOR LOW HEAD DRAINAGE TEMPLAT XTRA MOUNTING SIGNAL SLAB 24" MIN. #4 REBAR, ATTACH POWER W/(2) STAINLESS STEEL BANDS NOTE: J TURF POP , UP INSTALL HI -POP IRR. HEAD 1 1/2 ABOVE F.G. NOTE: F.G. 1 1/2" BELOW HARDSCAPE USE TEFLON TAPE ON ALL THREADED FITTINGS INSTALL CHECK VALVES FOR LOW HEAD DRAINAGE ' CONDUIT FOR GROUND ROD INSTALLATION 2 EXTRA 1" CONDUITS _ ra a_ . I i amWmkf mdM. I I 0� a... / •a• /WI&.vs A#ft . �— "1II I /1 4W=%l..00 1 1 r I I 1 I I I ®. 1 I gm CITY OF FONTANA llit. DRAWN ' IRRIGATION PLAN SCALE: Z TRACT N0.J� 1•=2o' DESIGNED °A GPZ (,/ 1�2 � CHECKED BY: APPROV 51152 Mo' N0' 4 1 M., ENGOM 0.cE 3134 7 LANDSCAPE ARCHItIECTURS GOLF DE1/IELOPMEN7 PLANNING SHEEP LIRE IRRIGATION DETAILS \lp,NDSCgp�,� ©F CI��- DESIGNED 'eft DRAWN DATE 10AS/01 SCALE MOT 0ATE: 3/13/02 n