Loading...
HomeMy WebLinkAbout3110-3PRINTED: 11-01-0I 10000 2" DIA LODGEPOLE PINE TREE / STAKE COPPER NA TH NATE / TREATED AND DRIVEN IN GROUND TO 2FT. MIN. DEPTH. 2 REQ'D 6''CINCH TIE' (4) REQ'D SHINGLE NAIL AR50R GUARD IN TURF AREAS LODGE POLE � � PREPARED BACKFILL MIX, SEE SPECIFICATIONS PERMANENT BASIN 3" BERM TO FORM WATERE3ASIN PERMANENT BASIN / TREE TRUNK TAPER 1:1 MAX. CUT oll 3" HIGH WATER 5A51N, CINCH TfE — - 4. � � � � � FEfi�TILIZER TABLETS EXISTING / � � � � � SLOPE Q PLANT PIT AT TIME OF PLANTING (DO NOT TWIST)SLOPE _I II, I I ( a' a : FERTILIZER TABLETS ~_FI1�l(SH GRADEa PREVAILING WINDIII — - P'OOTB,4LL -I I I III (SEE SPECS.) / I,.-� ((( Ed II III- ���-0I 1 11 I III DIRECTION I. TABLET5 TO BE 1 1/ " MIN. ROOTB LL DEPTHAGRIFORM BACKFILL MIX. I I ROOTBAL L ADDED PER MFG. RECOM D5. 2X THE WIDTH OF ROOTBALL -� I —) I I I I PUDDLE AND SETTLE BACKFIL , A 11/2 X MIN. ROOTBALL DEPTH � � � BACKFILL MIX. (SEE SPECS. PRIOR TO PLACEMENT OF SHRUB 2X THE WIDTH OF ROOTBLL 2X DIA. OF PUDDLE AND SETTLE BACKFIL - PRIOR TO PLACEMENT OF SHRUB ROOT 5ALL A STREET TREE PLANTING B SHRUB PLANTING C SHRUB PLANTING (SLOPE) PLANTING � g,T TREES SHALL BE PLANTED WITH THE BALL OF EARTH SURROUNDING THE ROOTS INTACT. STAKING AND TYING OF STRUT TR=S RADIUS EDGES 1/211 STREET TREE QUANTITIES ARE ESTIMATED AS ONE TREE FOR EVERY 40 L.F. OF TREES IN CONTAINERS SHALL HAVE THE CONTAINERS REMOVED PRIOR TO PLANTING. PROPERTY ADJACENT TO THE STREET. STREET TREE SPAGINS SHALL BE BETWEEN CONTAINERS SHALL BE REMOVED WITHOUT INJURY TO ROOTS OR BREAKING THE BALL OF ALL TREES, UNLESS OTHERWISE SPECIFIED, SHALL BE HELD VERTICALLY WITH 2 -INCH 30 AND 40 FEET ON CENTER WITH ACTUAL 5PACING AND LOCATION AS EARTH SURROUNDING THE ROOTS. POT-BOUND TREES WILL BE REJECTED. BACKFILL AFTER ROUND BY 8 FEET TREATED LODGE POLE PINE STAKES PLACED 36 INCHES IN THE DETERMINED BY THE PARKS, RECREATION AND COMMUNITY SERVICES PLANTING OF THE TREES SHALL BE TAMPED FIRMLY INTO PLACE WITHOUT INJURING THE GROUND IN A MANNER TO AVOID INJURY TO THE ROOTS OR THE BREAKING OF THE FIN15H GRADE DEPARTMENT FOLLOWING INSTALLATION OF PUBLIC, IMPROVEMENTS PRIOR TO ROOTS OF THE TREES OR BREAKING UP THE BALL OF EARTH SURROUNDING THE ROOTS. BALLS OF EARTH SURROUNDING THE ROOTS. THE STAKES SHALL BE PLACED AT RIGHT ANGLES PREVAILING WIND. (TURF SIDE) 155UANCE OF CERTIFICATE OF OCCUPANCY. TREES MAY BE GROUPED FOR DESIGN AL PLANTING .SHALL BE IN ACCORDANCE WITH CITY OF COLTON STREET PLANTING TO THE PURP05ES AT DISCRETION OF CITY. DETAIL. TRUNKS OF TREES SHALL BE SECURED TO HOLD THE TREES UPRIGHT WITHOUT INJURY HOLES FOR PLANTING TREES SHALL BE EXCAVATED A MINIMUM OF TWICE AS WIDE 121M CONDITION OE $TREET AND 8=112E1EN'Ps3 POR PLANT'S FOR A PERIOD OF SIX MONTHS. THE METHOD OF STAKING AND TYING SHALL BE A5 THE ROOT BALL WIDTH AND TWICE A5 DEEP AS THE ROOT BALL DEPTH. APPROVED BY THE PARKS DIRECTOR. UNLESS OTHERWISE SPECIFIED, ALL TREES SHALL BE FURNISHED IN CONTAINERS OF NOT USE THE FOLLOWING BACKFILL MIX FOR AVERASE SOIL CONDITIONS AND WHEN NO LESS THAN 15 GALLON CAPACITY IN ACCORDANCE WITH STANDARD NURSERY PRACTICE. TRIMMINS AND' PRUNING O1' ST'IMET TREES I" ORGANIC 501L REPORTS ARE AVAILABLE. TO OBTAIN ONE CUBIC YARD OF 4„ BACKFILL MIX: TREES SHALL BE 3/4 TO I INCH IN DIAMETER AND FROM 5-1/2 TO -7 FEET TALL. DIAMETERS PRUNING SHALL BE LIMITED TO THE MINIMUM NECESSARY TO REMOVE INJURED TWIGS AND SHALL BE MEASURED 48 INCHES ABOVE THE GROWN ROOTS. BRANCHES, AND TO COMPENSATE FOR LOSS OF ROOTS DURING TRANSPLANTING, BUT NEVER TO EXCEED ONE-HALF OF THE BRANCHING STRUCTURE. UPON APPROVAL OF THE 1/2 GUBIG YARD 50REENED SITE TOPSOIL 1/2 CUBIC, YARD NITROLIZED 5HAVIN65 PALM TREES SHALL BE HEALTHY, HAVE A NORMAL CONFIGURATION AND BE WELL ROOTED. PARKS DIRECTOR, PRUNING MAY BE DONE BEFORE DELIVERY OF PLANTS, BUT NOT LBS. IRON SULFATE THE ROOTS SHALL SHOW NO EVIDENCE OF HAVING BEEN RESTRICTED, DEFORMED, OR BEFORE PLANTS HAVE BEEN INSPECTED AND APPROVED. GUTS OVER THREE-OUARTERS M'' Mi2 El I I II I I I I- 10 LBS. ORGANIC GYPSUM ROOT -BOUND AT ANY TIME. ALL PLANTS SHALL BE WELL GROWN, FREE FROM INSECT OF AN INCH IN DIAMETER SHALL BE PAINTED WITH AN APPROVED TREE WOUND PAINT. I III I ( I I I I III III III I A6RIFORM PLANTING TABLETS PER MANUFACTURERS RECOMMENDED PESTS, GROWN IN NURSERIES WHICH HAVE BEEN INSPECTED BY THE STATE DEPARTMENT OF I — RATE AGRICULTURE, AND BE DELIVERED WITH A PINTO TAG. ALL PLANTS SHALL BE NO. I GRADE WATERING Of STRC-ETI— AAHI THEY HALL HAVE 1ED OR VARIETY THE TREE SHALL BE PLACED WITHIN THE EXCAVATION 50 THAT ITS ROOT GROWN �ORMALR, W®LRLMDEVE OPAL LAN S S 5 SMS �ND7VISOROUS ROOT SYSTEMS.PLANTS. AFTER ALL OTHER YVORK, APPURTENANT TO PLANTING HAS BEEN COMPLETED, EACH TREE BEARS THE SAME RELATIVE POSITION TO FINISHED GRADE A5 IT DID TO THE 501L SHALL BE FREE FROM D15FI6URIN6 KNOTS, INJURIES, ABRASIONS OF THE BARK, SUN SHALL BE WATERED IMMEDIATELY WITH A MINIMUM OF 20 GALLONS OF WATER AND SURFACE WHERE THE TREE WAS GROWN. ANY TREES WHICH SETTLE DEEPER THAN 50ALDIN6 OR OTHER OBJECTIONABLE D1596UREMENT5. PLANTS NOT CONFORMING TO THE IRRIGATED TO APPROVAL OF PARKS, DIRECTOR. AFTER TH15 WATER HAS SETTLED AND SPECIFIED ABOVE SHALL BE RAISED BACK TO THE CORRECT LEVEL, OR REOUIREMENT5 HEREIN SHALL BE CONSIDERED A5 DEFECTIVE, AND SUCH PLANTS, WHETHER THE 501L 15 SUFFICIENTLY DRY, BASINS SHALL BE CULTIVATED TO PREVENT CRUSTING REPLACED, AT THE OPTION OF THE CONTRACTOR. AFTER THE TREE HAS BEEN IN PLACE OR NOT, WILL BE MARKED AS REJECTED AND SHALL BE REMOVED IMMEDIATELY AND EVAPORATION. PLACED, ADDITIONAL BACKFILL SHALL BE ADDED TO THE HOLE TO COVER FROM THE SITE OF WORK AND REPLACED WITH SUITABLE PLANTS. 03 REBAR, CONTINUOUS APPROXIMATELY ONE-HALF THE HEIGHT OF THE ROOT BALL. WATER SHALL BE ADDED TO THE TOP OF THE PARTLY FILLED HOLE TO THOROUGHLY 5ATURATE THE ROOT BALL AND ADJACENT SOIL. ALL TREES PLACED WITHIN A PERIMETER OF PAVING SHALL BE SURROUNDED WITH BRICKS OR GRATES ACCEPTABLE TO THE PARKS DIRECTOR. NATIVE SOIL S09o, COMPACTED NOTE: D STREET TREE (PLANTING NOTES 71RJANIISULAR SPACED PLANTIN& DIA6RAM MOW CURB SHALL BE PLACED BETWEEN ALL GRA55 AND PLANTER AREAS UNLESS OTHERW15E NOTED. B EDGE of PLANTER AREA A A PLANT E CONCRETE MOWCURB G A = I/2 OF SPAM I NCS o 36.. y� o B = SPAG I NG —� G = -75516" OF SPAO I NG DIAL TIM TWO WORKING BEFORE ti DAYS BEFORE YOU DIG YOU DIG 8-30-03 EXPiRAT[Qi DATE TOLL FREE 1-800-422-4133 A PUBLIC SERVICE BY FSHRUB P DETAIL UNDERGROUND SERVICE ALERT OF,� G�- SE"C" MAS` CITY OF FONTANA ® r SLA INC. Z DRAUJN BY: SCALE= Landscape Architecture and Site Planning and PLANS F =PARED LMER WPERVISI[ON OF Date Date DLA PLANTING DETAILS N.T.S. Reference Plans For� DESIGNED BY.- STS DATE: ® ® 119 N. Maple St. Suite N, Cord CA. 928$ $,q�`ER MILLER Parks JA2 15 9 4 1 Date 89 !Q E Y 16 i O N 8 ,4pp d l909)131-1124 FAX (W13) 131-6.061se 51 11-@�-01 theImprovements CHECKED 8Y: 011* NO. � _ 13AX CITY ENGINEER 51152 R.C.E. 3110 PRINTED: 11-01-0I