Loading...
HomeMy WebLinkAbout2960-1GENERAL C NOTES: (INLAND EMPIRE UTILITY AGENCY) 1. ALL WORK SHALL BE DONE IN STRICT CONFORMANCE WITH THE PROJECT SPECIFICATIONS AS APPROVED BY THE INLAND EMPIRE UTILITY AGENCY (IEUA), THE CITY OF FONTANA AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (LATEST EDITION) AND THE IEUA STANDARD DETAIL SHEET OF THIS PLAN SET (SHEET No.'S 2 AND 3) AS APPROPRIATE. 2. ANY CONTRACTOR PERFORMING WORK ON THIS PROJECT SHALL FAMILIARIZE HIMSELF WITH THE SITE AND SHALL BE SOLELY RESPONSIBLE FOR ANY DAMAGE TO EXISTING FACILITIES RESULTING DIRECTLY OR INDIRECTLY FROM HIS OPERATIONS, WHETHER OR NOT SHOWN ON THESE PLANS. 3. ALL OBSTRUCTIONS WITHIN THE AREA TO BE IMPROVED ARE TO BE REMOVED OR RELOCATED AT THE DIRECTION OF THE ENGINEER. UTILITIES ARE TO BE RELOCATED BY THEIR RESPECTIVE OWNERS. THE CONTRACTOR IS REFERRED TO SECTION 5 OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION. 4. UTILITY LINE LOCATIONS WERE TAKEN FROM THE RECORD AND WERE NOT LOCATED IN THE FIELD UNLESS OTHERWISE NOTED ON THE PLAN. THE CONTRACTOR IS REFERRED TO SECTION 5 OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION. 5. IN CASE OF ANY ACCIDENTS INVOLVING SAFETY MATTERS COVERED BY SECTION 6424 OF THE CALIFORNIA LABOR CODE, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE STATE DIVISION OF INDUSTRIAL SAFETY. 6. CALL UNDERGROUND SERVICE ALERT (800) 227-2600 FOR UNDERGROUND LOCATIONS 48 HOURS BEFORE DIG. 7. THE CONTRACTOR SHALL OBTAIN A TRAFFIC CONTROL PERMIT 48 HOURS PRIOR TO THE TIME OF CONSTRUCTION WITHIN THE PUBLIC RIGHT-OF-WAY. TFC ONTRACTOR IS REFERRED TO SECTION 7-10.3 OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS 'CO STRUCTION. 8. THE CONTRACTOR SHALL RENEW OR REPLACE ANY EXISTING TRAFFIC STRIPING AND/OR PAVEMENT MARKINGS WHICH DURING HIS OPERATIONS HAVE BEEN EITHER REMOVED OR THE EFFECTIVENESS OF WHICH HAS BEEN REDUCED. RENEWAL OF PAVEMENT STRIPING & MARKINGS SHALL BE DONE IN CONFORMANCE WITH SECTION 310-5.6 OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION. 9. ALL SEWER MAINS SHALL BE BELL AND SPIGOT EXTRA STRENGTH VITRIFIED CLAY PIPE (VCP) SEWER PIPE UNLESS OTHERWISE NOTED ON THE PLANS. 10. PRIOR TO STARTING CONSTRUCTION, THE CONTRACTOR SHALL VERIFY LOCATION AND ELEVATION OF EXISTING SEWER MAIN(S) AND NOTIFY AND OBTAIN APPROVAL OF THE DESIGN ENGINEER AND IEUA OF ANY VARIATION FROM DESIGN. 11. CONSTRUCTION SHALL NOT BEGIN ON FACILITIES TO BE OWNED BY IEUA UNTIL AFTER ISSUANCE OF A PERMIT BY IEUA TO ALLOW THE CONSTRUCTION AND ALSO AFTER A PRE -CONSTRUCTION CONFERENCE TO BE HELD AT LEAST 1 WEEK PRIOR TO BEGINNING CONSTRUCTION. 12. IN ADDITION, IEUA AND THE CITY OF FONTANA SHALL BE NOTIFIED A MINIMUM OF 48 HOURS PRIOR TO ANY CONSTRUCTION IN THE VICINITY OF THE TRUNK SEWER OR ANY FACILITIES OWNED AND OPERATED BY IEUA AND/OR THE CITY OF FONTANA. 13. ALL TRENCHING AND/OR SHORING SHALL MEET REQUIREMENTS OF CAL -OSHA. 14. THE CONTRACTOR SHALL SUBMIT COPIES OF HIS DEPARTMENT OF INDUSTRIAL SAFETY PERMIT TO IEUA AND TO THE CITY OF FONTANA. 15. SHOP DRAWINGS AS REQUIRED BY THE PERMIT SHALL BE APPROVED BY IEUA PRIOR TO BEGINNING THE CONSTRUCTION. 16. UNLESS OTHERWISE APPROVED, LOW PRESSURE WATER TEST FOR THE GRAVITY SEWER LINES AND PRESSURE WATER TEST FOR THE PRESSURIZED PIPELINES SHALL BE PERFORMED IN CONFORMANCE WITH SECTION 306-1.4. OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION. ENGINEER'S NOTICE TO CONTRACTOR THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS, TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS. THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OR CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. A.P.N.: 23B -091 -SB PROPERTY ADDRESS: 10661 ETIWANDA AVENUE FONTANA, CALIFORNIA 92337 I MAI 0 THE LAND REFERRED TO IN THIS SURVEY IS DESCRIBED AS FOLLOWS: THAT PORTION OF THE NORTHWEST 1/4 OF SECTION 28, TOWNSHIP 1 SOUTH, RANGE 6 WEST, SAN BERNARDINO BASE AND MERIDIAN, IN THE COUNTY OF SAN BERNARDINO, STATE OF CALIFORNIA, ACCORDING TO UNITED STATES GOVERNMENT PLAT THEREOF, DESCRIBED AS FOLLOWS: BEGINNING AT A POINT IN THE EAST LINE OF ETIWANDA AVENUE, 60 FEET WIDE, THAT IS 974.05 FEET SOUTH FROM THE SOUTH LINE OF SLOVER AVENUE, 60 FEET WIDE, SAID POINT BEING THE POINT OF BEGINNING, THENCE NORTH 89' 18'55" EAST 780.67 FEET; THENCE SOUTH 72'32'30" EAST 115.18 FEET TO THE BEGINNING OF A TANGENT CURVE CONCAVE SOUTHWESTERLY WITH A RADIUS OF 468.34 FEET; THENCE SOUTHERLY ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 72045'55" A DISTANCE OF 594.79 FEET; THENCE SOUTH 00'13'25" WEST 465.81 FEET TO A POINT ON THE SOUTH LINE OF THE NORTH 118 ACRES OF SAID NORTHWEST 1/4 OF SAID SECTION 28; THENCE WESTERLY ALONG SAID SOUTH LINE 1233.99 FEET, MORE OR LESS, TO THE EAST LINE OF ETIWANDA AVENUE, 60 FEET IN WIDTH; THENCE NORTH ALONG THE EAST LINE OF ETIWANDA AVENUE TO THE POINT OF BEGINNING. QFLOFESS j t No. C45935 � X Exp. 12/31 SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT r� SLOVER AVENUE IEUA DWG. No. D4597-8 STATION 65+00.00 EXISTING 24" IEUA VCP (SEWER) STATION 10+00.00= CENTERLINE INTERSECTION OF ETIWANDA & SANTA ANA il/ SANTA ANA AVENUE LOCKWOOD ENGINEERING CO. 380 W. FOOTHILL BOULEVARD STE. F RIALTO, CALIFORNIA 92376 (909) 875-5015 FAX (909) 875-4567 MARK I DESCRIPTION REVISIONS LOCATION MAP: 1"=100'N APPR. I DATE I CITY APPR. I DATE ►safe r - tell. 7-� eog�-o.t�.�v�. CIVIL ENGINEER FOR INLAND EMPIRE UTILITY AGENCY LEGEND: TC INTERSTATE 10 INV W LF z w SITE a W t-- INDICATES CURB AND GUTTER VCP AIRPORT DRIVE a w z z 3 W SANTA ANA STATION 10+00.00= CENTERLINE INTERSECTION OF ETIWANDA & SANTA ANA il/ SANTA ANA AVENUE LOCKWOOD ENGINEERING CO. 380 W. FOOTHILL BOULEVARD STE. F RIALTO, CALIFORNIA 92376 (909) 875-5015 FAX (909) 875-4567 MARK I DESCRIPTION REVISIONS LOCATION MAP: 1"=100'N APPR. I DATE I CITY APPR. I DATE ►safe r - tell. 7-� eog�-o.t�.�v�. CIVIL ENGINEER FOR INLAND EMPIRE UTILITY AGENCY LEGEND: TC INDICATES TOP OF CURB INV INDICATES INVERT OF PIPE LF INDICATES LINEAL FEET C&G INDICATES CURB AND GUTTER VCP INDICATES VITRIFIED CLAY PIPE FL INDICATES FLOWLINE FF INDICATES FINISH FLOOR SLOVER AVENUE A N AVENUE VICINITY MAP INLAND EMPIRE UTILITIES AGENCY* p *A Municipal Water District Date �a LOCATION MAILING ADDRESS 9400 Cherry Avenue, Building A Post Office Box 697 Fontana, California 92335 Rancho Cucamonga, California 91730 Telephone (909) 357-0241 GENERAL NOTES: (CITY OF FONTANA) 1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BE REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN THE PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA DIVISION OF INDUSTRIAL SAFETY 8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT-OF-WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 111111-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 13. STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED. 14. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 15. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION OF THE CITY ENGINEER. 16. REMOVAL AND REPLACEMENT OF SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 17. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 18. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 19. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT-OF-WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 20. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 21. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 22. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 23. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 24. IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT. 25. SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700 FOR V.C.P. 26. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. 27. SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT. 28. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 29. ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. 30. TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT-OF-WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT. 31. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF CURB AT THE LOCATION OF THE SEWER LATERAL. 32. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 33. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 34. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 35. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 36. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 37. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 38. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. SHEET INDEX: SHEET 1 OF 5 COVER SHEET SHEET 2 OF 5 PLAN & PROFILE SHEET 3 OF 5 MANHOLE DETAILS SHEET 4 OF 5 BEDDING DETAILS SHEET 5 OF 5 I.E.U.A. SPECIFICATIONS UNDERGROUND SERVICE ALERT c CALL:TOLL FREE 1-800 227-2600 TWO WORKING DAYS BEFORE YOU DIG "CAUTION": REMEMBER THAT THE USA CENTER NOTIFIES ONLY THOSE UTILITIES BELONGING TO THE CENTER. THERE COULD BE OTHER UTILITIES PRESENT AT THE WORK SITE. THE CENTER WILL INFORM YOU OF WHOM THEY WILL NOTIFY. FONTANA IZE&IOWAL CONN. ;:-ZV PROJECT NO CWO t S0 8 CITY OF FONTANA, CALIFORNIA PUBLIC WORKS DEPARTMENT DRAWN BY: SEWER IMPROVEMENT PLANS SCALE: HORIZ.-- 1 "=40' DWH USF BESTWAY, INC. VERT. -I"=4' DESIGNED BY:ETIW A AVENUE DATED: DWH WEE SLS R & SANTA ANA AVE 06/13/01 CHECKED BY: RO , . ` 71a Q DR. No. SHEET CWL ` frI1 o OF a9� 1 5 04G24 --I