HomeMy WebLinkAbout2955-1CITY OF FONTANA
GENERAL NOTES
FO R
STREET IMPROVEMENT PLANS
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD
PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS
CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE
LATEST EDITION UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN
NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE
CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR
RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL AL OF THE CITY ENGINEER.
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY
DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK.
INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DA YS PRIOR TO THE
STARTOFANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND
PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST
NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES,
DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES ATALL TIMES.
7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR
TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL
SAFETY.
8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE
GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANTTO THE
REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES
LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND
MOVEMENT.
9. NO MATERIAL OR EQUIPMENTSHALL BE STORED IN THE PUBLIC RIGHT-OF-WAY WITHOUT
OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE.
10, THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE
INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE,
IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE
PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT
UNDERGROUND SERVICEALERTATI-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION.
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES
INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING,
LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD
CONTROLAND CAL -TRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS
NOTICE PRIOR TO WORKAROUND THEIR FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES
WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE
APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
13. CURVE DATA REFERS TO THE FACE OF CURB.
14. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE NOTED.
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BESET BY THE ENGINEER TO ENABLE THE
CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING
DURING CONSTRUCTION.
PRIVATE ENGINEER'S NOTICE TO CONTRACTOR
ALL CONTRACTORS AND SUBCONTRACTORS PERFORMING WORK SHOWN ON OR RELATED TO THESE
PLANS SHALL CONDUCT THEIR OPERATIONS SO THAT EMPLOYEES ARE PROVIDED A SAFE PLACE
TO WORK AND THE PUBLIC IS PROTECTED. ALL CONTRACTORS AND SUBCONTRACTORS SHALL
COMPLY WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS" OF THE U.S.
DEPARTMENT OF LABOR, AND WITH THE STATE OF CALIFORNIA DEPARTMENT OF
INDUSTRIAL RELATIONS " CONSTRUCTION SAFETY ORDERS". THE CIVIL ENGINEER SHALL NOT
BE RESPONSIBLE IN ANY WAY FOR THE CONTRACTOR OR SUBCONTRACTOR'S COMPLIANCE
WITH SAID REGULATIONS AND ORDERS. CONTRACTOR FURTHER AGREES THAT HE SHALL
ASSUME SOLE COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE
COURSE OF CONSTRUCTION ON THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS
AND PROPERTY. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO
NORMAL WORKING HOURS, AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND
HOLD THE OWNER, THE CITY AND CIVIL ENGINEER HARMLESS FROM ANY AND
ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON
THIS PROJECT, EXCEPTING LIABILITY ARISING FROM SOLE NEGLIGENCE OF THE OWNER OR ENGINEER.
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENTTIES OR
BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
17. REMOVALAND REPLACEMENTOF EXISTING SURVEY CONTROL, INCLUDING SURVEY
MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BYA REGISTERED CIVIL
ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A
RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE
ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE
ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES ATALL
TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED ATALL TIMES IN THE CONSTRUCTION
AREA FOR RESIDENTS AND EMERGENCY VEHICLES.
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUSTCONTROL,
INCLUDING ADEQUATE WATERING, ATALL TIMES.
20. ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND VELOCITIES
EXCEED 25 MILES PER HOUR.
21. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE
DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY AD)ACENTTO THE RIGHT-OF-WAY DURING
CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
22. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
23, A GEOTECHNICAL ENGINEER SHALL CERTIFYALL BACKFILL COMPACTION. FAILURE TO OBTAIN
THE REQUIRED DENSITY SHALL REQUIRE REWORKING OF THATT PORTION OF THE WORK UNTIL
THE SPECIFIED DENSITY IS OBTAINED.
24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING
STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MA Y REQUIRE
TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEA LEAVING IMPROVEMENTS.
25, THE FINAL LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE APPROVED A
THE TIME OF CONSTRUCTION AND SHALL CONFORM TO THE CITY OF FONTANA STANDARD
DETAILS.
26. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLORAND FINISH TO MATCH
EXIST] NG CONCRETE.
27, THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB ATTHE LGCATION
OF THE SEWER LA LATERAL
28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN
PLACED, INSPECTED AND APPROVED.
29, ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING
OF STREETS.
30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO
PLACEMENT.
31. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUB)ECTTO REVISION AND
APPROVAL OF THE CITY ENGINEER AS DETERMINED BY SOILS TESTS TAKEN AFTER COMPLETION OF
ROUGH GRADING.
32. ACTUAL THICKNESS OF A.C. PAVEMENT ANWOR BASE COURSE MATERIAL FOR STRUCTURAL
STREET SECTIONS SHALL BE RECOMMENDED BY GEOTECHNICAL REPO RTAND SUBMITTED TO THE
CITY OF FONTANA FOR APPROVAL UPON COMPLETION OF ROUGH GRADING.
33. ALL MANHOLES, CLEAN --OUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO
FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
34. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING,
BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC
ENGINEER.
35. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALKS
AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE CITY ENGINEER.
36. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD,
WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
UNDERGROUND UTILITIES & STRUCTURES
THE EXISTENCE AND APPROXIMATE LOCATION OF ANY UNDERGROUND UTILITIES OR
STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE
RECORDS. TO THE BEST OF OUR KNOWLEDGE , THERE ARE NO EXISTING (UTILITIES OR
STRUCTURES EXCEPT AS SHOWN ON THESE PLANS. THE ENGINEER ASSUMES NO
LIABILITY AS TO THE EXACT LOCATION OF SAID SUBSTRUCTURES NOR FOR UTILITIES OR
IRRIGATION SUBSTRUCTURES WHOSE LOCATIONS ARE NOT SHOWN. THE CONTRACTOR SHALL
BE RESPONSIBLE FOR NOTIFYING ALL UTILITY AND IRRIGATION COMPANIES PRIOR TO WORK
ON EXCAVATION TO DETERMINE EXACT LOCATION OF ALL SUBSTRUCTURES AFFECTING THIS
WORK, WHETHER OR NOT SHOWN HEREON, AND FOR ANY DAMAGE OR PROTECTION TO
THESE SUBSTRUCTURES.
CONSTRUCTION NOTES
CONSTRUCT0.1' MIN. OVERLAY, GRIND EXISTING PAVEMENT
0.1' TO ACCEPT OVERLAY.
CONSTRUCT 0.3' A,C. PAVEMENT ON 4" A.B.
O
O CONSTRUCT 61/2" A.C. ON COMPACTED NATIVE MATERIALS.
a CONSTRUCTS" P.C.C. CURB AND 18" GUTTER PER CITY STD. No.1003.
O CONSTRUCT P.C.C. DRIVEWAY PER CITY STD. No. 102-C.
® CONSTRUCT P.C.C. SIDEWALK PER CITY STD. No. 1015, SEE PLAN FOR WIDTH.
(�) AD)USTTO GRADE.
�$ CONSTRUCT P.C.C. RIBBON GUTTER TO MATCH EXISTING.
REMOVE EXISTING GUARD POST.
1p REMOVE EXISTING POWER POLE BY OTHERS.
REMOVE EXISTING ANCHOR BY OTHERS.
1 .
1 CONSTRUCT SIDEWALK DRAIN PERA.P.W.A
STR 151--1, S=4''SEE DETAIL HERON.
13 PROTECT EXISTING ABOVE GROUND WATER LINE IN PLACE.
PROTECT IN PLACE.
RELOCATE EXISTING SIGN.
RELOCATE EXISTING TRAFFIC SIGNAL BOX - SEE PLAN.
RELOCATE EXISTING WATER METER.
10 RELOCATE EXISTING FIRE HYDRANT.
1 REMOVE EXISTING P C C SLAB
A.P.W.A. STANDARD 151-T
?7. 600 MM.
� C24"1 z
I N LET INLET
;a
SEE NOTE B
TYPE 2 TYPE I
cp I
SECTION
INLET TYPE 2
16MM.
(5/8") ml
6 MM (1/4") V
ETA1--1
ILOFANCHOR1
Q
�p REMOVE EXISTING DELINEATORS.�-
-�
O21 PROTECT EXISTING 4" DRAIN IN PLACE. 25 INSTftL.L STKEE? Li 614T P1=R CITE( 5Tb 1016
O I6 TO Fib 2W Vel � 2 000 H rsv
• STKE E7 L ELT , ,
22 CONSTRUCTS"A.C. DIKE PER CITY STD. No -136. '9j0' 1110H W/4' LMrb MAST AKM
23 BACKFILL WITH CLEAN SAND AND CAP WITH 2° fNTUK6: WM19 94AU at44441 Of LOt HEW
E•
A.C. TO THE SATISFACTION OF THE CITY ENGINEER. �\9 NC
4 DEPRESS LIP OF GUTTER TO ACCOMMODATE DRAINAGE
TO THE SATISFACTION OF THE CITY ENGINEER.
BASIS OF BEARINGS:
BASIS OF BEARING TAKING FROM THE NORTH LINE OF VALLEY
BOULEVARD, BEING NORTH 89037143"' EAST PER DIVISION OF
HIGHWAYS R/W MAP NO. 842600 DATED )ULY 19,1937 AND ON
FILE IN THE SAN BERNARDINO COUNTY ROAD DEPARTMENT.
hf nTP,
RESTRI PE PAVEMENT SURFACE TO THE
SATISFACTION OF THE CITY OF FONTANA
FORUM CAPITAL MANAGEMENT
1601 WEST MISSION BOULEVARD
POMONA, CALIFORNIA 91766
(909) 623-2070
PROJECT MANAGER: MR. JOHN COELHO
VICINITY MAP
N.T.S.
SAN BERNARDINO AVENUE
HINGE COVER AT
TOP OF FRAME
RECTANGULAR
FRAME AND
COVER PER -
5TD. PLAN
152.
_ _1_. L
BAR
SPACING MM.
300 (12")
- -
450 (18")
240 (71
I
I
R/W
�
240 (7)
900 (36")
z r.
1050 (42")
210 (61
00
180 (5")
1350 (54")
225 (6-1/2")
I
I
180 (5")
1650 (66")
I
I
1
f
1800 (72")
120 (3-1/2")
I
�- ANCHOR I
7 (311)
CURBFACE �n %
FL _----lz FL
POINT M POINT N POINT P
A
3000 MM. (101)
TC GRADE LINE AS
SHOWN ON PROFILE -
TOP OF CURB
FL
POINT N
POINTM
FOR S = 750 MM. (301 AND LESS, USE 2
ANCHORS. OTHERWISE, USE 3 ANCHORDS,
FOR S =1200 MM. (481 AND LESS,
B= 75 MM. (3")
USE 64X51X9.5 (2-1/2"X2„X3/8")
GALVANIZED STEEL ANGLE.
OTHERWISE, B=100 MM. (4"). USE 89X76X12.7
(3-1/2"X3"XI/21 GALVANIZED STEEL ANGLE.
BAR ARE #10M. (6).
NOTES
1. FLOOR OF BOX SHALL BE TROWLED SMOOTH.
PLAN
PROFILE
600 MM
x(24")
`6
I 0
i
SEE
NOTE 8
PIPE PER
IMPROVEMENT
OR GRADING
PLAN
75 MM
(3") MIN
a \11 a10
150 MM
Y C6")
SECTION
INLET TYPE I
CURB FACE
3000 MM. (101)
TOP OF CURB
r- FL
POINT Q
�- POINT P POINT Q -�
GALVANIZED STEEL SIDEWALK
o ANGLE FINISH
0'--, m
BATTER 3:12. - SEE NOTE 8 1
I
200 MM 150 MM
(8") (6")
GUTTER TO
MATCH EXISTING SECTION A�A
150 MM
(6")
2. IF THE TOE OF SLOPE IS ALLOWED WITHIN THE R/W, INLET TYPE 1
BEGINS AT THE TOE RA THEIR THAN AT THE R/W LINE.
3. FOR OPEN DITCH (TYPE 2), THE 600 mm (24") EXTENSION BEYOND
THE R/W LINE IS NOT REQUIRED WHEN BACK OF WALK IS 600 mm
(24") OR MORE FROM THE R/W LINE; HOWEVER, THE PIPE SHALL
EXTEND TO THE R/W LINE IN ANY EVENT.
4. TOP OF INLET STRUCTURE (TYPE 1 & 2) SHALL BE FLUSH WITH
ADJACENT SURFACE WHERE PRACTICAL.
5. A HEADED STEEL STUD 16 mm x 160 mm WITH A 25 mm HEAD
(5/8" x 6-3/8", 1" HEAD) ATTACHED BY A FULL PENETRATION BUTT
WELD MAY BE USED AS AN ALTERNATE ANCHOR.
6. NORMAL CURB FACE AT POINT M AND Q. CURB FACE IS B + 125
mm (5") AT POINT N AND P.
7. THE 75 mm (3") LEG OF THE 16 mm (5/8") DIA ANCHORS SHALL
BE PARALLEL TO THE TOP OF SIDEWALK.
8. SLOPE = 2.0%.
9. DIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS
ARE NOT EXACTL Y EQUAL VALUES. IF METRIC UNITS ARE USED, ALL
VALUES USED FOR CONSTRUCTION SHALL BE METRIC VALUES. IF
ENGLISH UNITS ARE USED, ALL VALUES USED FOR CONSTRUCTION SHALL
BE ENGLISH VALUES. HOWEVER, ASTM 615 REINFORCING STEEL MAY BE
SUBSTITUTED FOR ASTM 615M STEEL.
L
N
150 MM
(61 IOM 0 420 MM
0�3 012") MAX OC
SECTION B -B -
JN28�1
0
0
c6
0
V
0
N
m
N
S2
00
ti
v
O
C54r
n
Z
-r
BAR
SPACING MM.
300 (12")
240 (79
450 (18")
240 (71
600 (24")
240 (7)
750 (30")
240 (7)
900 (36")
240 (79
1050 (42")
210 (61
1200 (48")
180 (5")
1350 (54")
225 (6-1/2")
1500 (60")
180 (5")
1650 (66")
180419
1800 (72")
120 (3-1/2")
3000 MM. (101)
TC GRADE LINE AS
SHOWN ON PROFILE -
TOP OF CURB
FL
POINT N
POINTM
FOR S = 750 MM. (301 AND LESS, USE 2
ANCHORS. OTHERWISE, USE 3 ANCHORDS,
FOR S =1200 MM. (481 AND LESS,
B= 75 MM. (3")
USE 64X51X9.5 (2-1/2"X2„X3/8")
GALVANIZED STEEL ANGLE.
OTHERWISE, B=100 MM. (4"). USE 89X76X12.7
(3-1/2"X3"XI/21 GALVANIZED STEEL ANGLE.
BAR ARE #10M. (6).
NOTES
1. FLOOR OF BOX SHALL BE TROWLED SMOOTH.
PLAN
PROFILE
600 MM
x(24")
`6
I 0
i
SEE
NOTE 8
PIPE PER
IMPROVEMENT
OR GRADING
PLAN
75 MM
(3") MIN
a \11 a10
150 MM
Y C6")
SECTION
INLET TYPE I
CURB FACE
3000 MM. (101)
TOP OF CURB
r- FL
POINT Q
�- POINT P POINT Q -�
GALVANIZED STEEL SIDEWALK
o ANGLE FINISH
0'--, m
BATTER 3:12. - SEE NOTE 8 1
I
200 MM 150 MM
(8") (6")
GUTTER TO
MATCH EXISTING SECTION A�A
150 MM
(6")
2. IF THE TOE OF SLOPE IS ALLOWED WITHIN THE R/W, INLET TYPE 1
BEGINS AT THE TOE RA THEIR THAN AT THE R/W LINE.
3. FOR OPEN DITCH (TYPE 2), THE 600 mm (24") EXTENSION BEYOND
THE R/W LINE IS NOT REQUIRED WHEN BACK OF WALK IS 600 mm
(24") OR MORE FROM THE R/W LINE; HOWEVER, THE PIPE SHALL
EXTEND TO THE R/W LINE IN ANY EVENT.
4. TOP OF INLET STRUCTURE (TYPE 1 & 2) SHALL BE FLUSH WITH
ADJACENT SURFACE WHERE PRACTICAL.
5. A HEADED STEEL STUD 16 mm x 160 mm WITH A 25 mm HEAD
(5/8" x 6-3/8", 1" HEAD) ATTACHED BY A FULL PENETRATION BUTT
WELD MAY BE USED AS AN ALTERNATE ANCHOR.
6. NORMAL CURB FACE AT POINT M AND Q. CURB FACE IS B + 125
mm (5") AT POINT N AND P.
7. THE 75 mm (3") LEG OF THE 16 mm (5/8") DIA ANCHORS SHALL
BE PARALLEL TO THE TOP OF SIDEWALK.
8. SLOPE = 2.0%.
9. DIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS
ARE NOT EXACTL Y EQUAL VALUES. IF METRIC UNITS ARE USED, ALL
VALUES USED FOR CONSTRUCTION SHALL BE METRIC VALUES. IF
ENGLISH UNITS ARE USED, ALL VALUES USED FOR CONSTRUCTION SHALL
BE ENGLISH VALUES. HOWEVER, ASTM 615 REINFORCING STEEL MAY BE
SUBSTITUTED FOR ASTM 615M STEEL.
L
N
150 MM
(61 IOM 0 420 MM
0�3 012") MAX OC
SECTION B -B -
JN28�1
0
0
c6
0
V
0
N
m
N
S2
00
ti
v
O
C54r
n
Z
-r