HomeMy WebLinkAbout2949-2EXISTING CURB
ONLY
OVERLA T
THICKNESS
EXISTING CURB
ONLY
/EXISTING CURB
AND GUTTER
F 0' - C
__ -0 -
EXISTING CURB EXISTING CURB
ONLY AND GUTTER
6 X3/8" LIPS
m
SECTION A -A
EXISTING A.C. PAVEMENT
SURFACE
12'
M$
01
I n�.niv�SS
SECTION B -B
X0.00'
OVERLAY
THICKNESS
SECTION C -C
6'
SECONDARY
STR2 ET
3/8" LIP PRIMARY
STREE
OVERLAY �- x•00'
THICKNESS � •00' OVERLAY
THICKNESS J
TYP. COLD PLANE AREA TYP. COLD PLANE AREA
AT EXISTING STREETS W/0 CROSS GUTTERS AT EXISTING STREETS WITH CROSS GUTTERS
*18' ON MAJOR INTERSECTIONS
TYPICAL COLD PLANE DETAILS.
N.T.S.
CONSTRUCTION NOTES:
1O
CONSTRUCT 0.30' (B -AR 4000) ASPHALT CONCRETE
(AC) OVER 1.0' OF
2�
NATIVE SOIL COMPACTED TO 95% R.C.
RELOCATE FIRE HYDRANT PER SAN GABRIEL VALLEY
WATER COMPANY
APPLY
STD. DWG. NO. 2-A.
03ADJUST
VALVE TO GRADE PER CITY OF FONTANA STD. DETAIL 130.
O
ADJUST MANHOLE TO GRADE.
2]APPLY
556,,
PROTECT EXISTING INLET GRATE.
REMOVE EXISTING 8" A.C. DIKE, REPLACE WITH 8" AC DIKE PER CITY
22.
OF FONTANA STD. DETAIL 136
77.
CONSTRUCT 0.17' A.C. OVERLAY (C2 -AR 4000).
M
CONSTRUCT 0.12' A.C. OVERLAY (C2 -AR 4000).
ARROW MARKING PER CALTRANS STD. PLAN A24A TYPE IV
9�
CONSTRUCT 0.20' (B -AR 4000) ASPHALT CONCRETE
(AC) OVER
(R).
NATIVE SOIL COMPACTED TO 95% R.C.
10
FILL CRACKS IN EXISTING A.C. PAVEMENT PRIOR TO
OVERLAY
LEGEND:
17227 STREET ADDRESS
HEADER CUT PER DETAIL ON SHEET 2
HEATER REMIX
REMOVE EXISTING PAVING AND/OR SUBGRADE,
REPLACE WITH A.C. (B2-AR4000). THICKNESS
AS NOTED
OVERLAY WITH AC (C2 -AR 4000) THICKNESS AS
NOTED, FILL CRACKS PRIOR TO OVERLAY EXCEPT IN
HEATER REMIX AREAS
0 EXISTING MANHOLE
® EXISTING UTILITY VALVE
EXISTING FIRE HYDRANT
STREET IMPROVEMENT GENERAL NOTES:
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT
PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK'). ALL REFERENCE
SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY
REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID
CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA PUBLIC SERVICES DEPARTMENT, ENGINEERING
DIVISION, PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING
DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE
STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION, UNLESS OTHERWISE DIRECTED BY THE
CITY TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC
CONTROL DEVICES AT ALL TIMES.
7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR
GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING,
SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO T; HE REQUIREMENTS OF THE DIVISION OF
INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN
THE POTENTIAL EXISTS FOR GROUND MOVEMENT.
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT
FOR THAT PURPOSE.
10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE
THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY
EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL
CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION.
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO,
GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED
WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING
DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY
AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND
WATER REQUIREMENTS.
13. CURVE DATA REFERS TO THE FACE OF CURB.
14. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE NOTED
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO
CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF
BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION.
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT
PRIOR NOTIFICATION TO THE CITY ENGINEER.
17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND
BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS
THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY
THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER
REPLACEMENT OF THE MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12
FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES.
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE
WATERING, AT ALL TIMES.
20. ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND VELOCITIES EXCEED 25 MILES PER HOUR
21. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC
OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
22. NO TRENCH BACK FILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
23. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACK FILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY
SHALL REQUIRE REWORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS.
UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR
LEAVING IMPROVEMENTS.
25. THE FINAL LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE APPROVED AT THE TIME OF
CONSTRUCTION AND SHALL CONFORM TO THE CITY OF FONTANA STANDARD DETAILS.
26. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE.
27. THE CONTRACTOR SHALL REPLACE THE "S" IN THE FACE OF THE CURB AT ANY SEWER LATERAL, IF CURB REMOVED
AND REPLACED AT THAT LOCATION.
28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND
APPROVED.
29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS.,
00
30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. I`�
31. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL OF THE CITY co
ENGINEER AS DETERMINED BY SOILS TESTS TAKEN AFTER COMPLETION OF ROUGH GRADING.
32. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR STRUCTURAL STREET SECTIONS SHALL C)
BE RECOMMENDED BY A GEOTECHNICAL REPORT AND SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL UPON
COMPLETION OF ROUGH GRADING.
0)
CD
33. ALL MANHOLES, CLEAN OUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE
PAVING CONTRACTOR UPON COMPLETION OF PAVING.
34. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADE'S, AND OTHER
TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. REPLACE ALL EXISTING STRIPE AND
PAVEMENT MARKINGS WITH THERMOPLASTIC UNLESS OTHERWISE DIRECTED.
IN
35. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALKS AFFECTED BY THE
CONSTRUCTION TO THE SATISFACTION OF THE CITY ENGINEER
36. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE
RECORD DRAWINGS TO THE CITY ENGINEER.
E
a
Under round Service Alert CITY OF FONTANA,CALIFORNIA
Esse SUBMITTED BY: DATE: Jv Leo ZOb�
SECTION 4216/4217 OF THE GOVERNMENT F -� SHOULD CONSTRUCTION OF THE REQUIRED PAVEMENT REHABILITATION PROJECT
FORE CODE REQUIRES A DIG ALERT IDENTIFICATION RF IMPROVEMENTS NOT COMMENCE WITHIN TWO
NUMBER BE ISSUED BEFORE A PERMIT TO `_'' c L.D. KING, INC. YEARS OF THE DATE OF APPROVAL SHOWN DRAWN BY GENERAL NOTES SCA
EXCAVATE WILL BE VALID No. 16434 2 Lr)4cin 2151 CONVENTION CENTER WAY HEREON AND CARRIED FORTH IN A DILIGENT MSM LE: N.T.S. 04
EXP. 6/30/05 SUITE 1008 MANNER THE CITY ENGINEER MAY REQUIRE DESIGNED BY ONSTRUCTION NOTES DATE:
FOR YOUR DIG ALERT I.D. NUMBER CALL �, �. ONTARIO, CA 91764
UNDERGROUND SERVICE ALERT '9 ��� (909) 937-0200 REVISIONS TO THE PLANS TO BRING THEM � ANU 7/16/01
TOLL FREE 1-800-227-2600 ca�-�F INTO CONFORMANCE WITH CONDITIONS AND CHECKED BY APP 0 BY: DATE. DRAWING NO.. 2
CARL J. FREEMA R.C.E. No. 16434 STANDARDS fN EFFECT.4-1
TWO WORKING DAYS BEFORE YOU DIG REV. REVISION DESCRIPTION DATE ENGR. CITY DATE EXPIRES: 6/30/05 DEW 294912
TY ENGINEER R.C.E. No. 115
124-09-506
1135-R
STRIPING CONSTRUCTION NOTES
1
APPLY
4" YELLOW CENTERLINE STRIPE PER CALTRANS STD. PLAN A20A
DETAIL
1.
2]APPLY
4" DOUBLE YELLOW STRIPE PER CALTRANS STD. PLAN A20A
DETAIL
22.
APPLY
12" SOLID WHITE CROSSWALK MARKING/STOP BAR AS SHOWN.
M
APPLY
ARROW MARKING PER CALTRANS STD. PLAN A24A TYPE IV
(L) &
(R).
APPLY
8" WHITE CHANNELIZATION STRIPE PER CALTRANS STD. PLAN A20D
DETAIL
38.
6
APPLY
4" SOLID WHITE STRIPE AS SHOWN.
❑7
APPLY
8" WHITE CHEVRON STRIPES CSD 30' O.C.
Fil
APPLY
8 DASHED WHITE LANE DROP STRIPE PER CALTRANS STD. PLAN
A20C DETAIL 37B.
APPLY
4" DASHED WHITE STRIPES PER CALTRANS STD. PLAN A20A
10
DETAIL 9.
NOT USED.
11
APPLY
RAILROAD CROSSING SYMBOL PER CALTRANS STD. PLAN A24C.
F21APPLY
4" SOLID WHITE OR DETAIL 27B EDGELINE PER CALTRANS STD.
PLAN A24B.
Fil
NOT USED.
14
APPLY
NUMERALS PER CALTRANS STD. PLAN A24C.
15
APPLY
"STOP" PER CALTRANS STD. PLAN A24D.
16
APPLY
"SIGNAL" PER CALTRANS STD. PLAN A24D.
17
APPLY
"AHEAD" PER CALTRANS STD. PLAN A24D.
18
NOT USED.
Fiq
APPLY
4" YELLOW CENTERLINE STRIPE PER CALTRANS STD. PLAN A20A
DETAIL
5.
LEGEND:
17227 STREET ADDRESS
HEADER CUT PER DETAIL ON SHEET 2
HEATER REMIX
REMOVE EXISTING PAVING AND/OR SUBGRADE,
REPLACE WITH A.C. (B2-AR4000). THICKNESS
AS NOTED
OVERLAY WITH AC (C2 -AR 4000) THICKNESS AS
NOTED, FILL CRACKS PRIOR TO OVERLAY EXCEPT IN
HEATER REMIX AREAS
0 EXISTING MANHOLE
® EXISTING UTILITY VALVE
EXISTING FIRE HYDRANT
STREET IMPROVEMENT GENERAL NOTES:
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT
PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK'). ALL REFERENCE
SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY
REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID
CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA PUBLIC SERVICES DEPARTMENT, ENGINEERING
DIVISION, PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING
DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE
STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION, UNLESS OTHERWISE DIRECTED BY THE
CITY TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC
CONTROL DEVICES AT ALL TIMES.
7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR
GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING,
SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO T; HE REQUIREMENTS OF THE DIVISION OF
INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN
THE POTENTIAL EXISTS FOR GROUND MOVEMENT.
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT
FOR THAT PURPOSE.
10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE
THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY
EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL
CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION.
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO,
GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED
WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING
DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY
AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND
WATER REQUIREMENTS.
13. CURVE DATA REFERS TO THE FACE OF CURB.
14. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE NOTED
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO
CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF
BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION.
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT
PRIOR NOTIFICATION TO THE CITY ENGINEER.
17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND
BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS
THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY
THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER
REPLACEMENT OF THE MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12
FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES.
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE
WATERING, AT ALL TIMES.
20. ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND VELOCITIES EXCEED 25 MILES PER HOUR
21. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC
OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
22. NO TRENCH BACK FILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
23. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACK FILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY
SHALL REQUIRE REWORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS.
UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR
LEAVING IMPROVEMENTS.
25. THE FINAL LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE APPROVED AT THE TIME OF
CONSTRUCTION AND SHALL CONFORM TO THE CITY OF FONTANA STANDARD DETAILS.
26. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE.
27. THE CONTRACTOR SHALL REPLACE THE "S" IN THE FACE OF THE CURB AT ANY SEWER LATERAL, IF CURB REMOVED
AND REPLACED AT THAT LOCATION.
28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND
APPROVED.
29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS.,
00
30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. I`�
31. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL OF THE CITY co
ENGINEER AS DETERMINED BY SOILS TESTS TAKEN AFTER COMPLETION OF ROUGH GRADING.
32. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR STRUCTURAL STREET SECTIONS SHALL C)
BE RECOMMENDED BY A GEOTECHNICAL REPORT AND SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL UPON
COMPLETION OF ROUGH GRADING.
0)
CD
33. ALL MANHOLES, CLEAN OUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE
PAVING CONTRACTOR UPON COMPLETION OF PAVING.
34. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADE'S, AND OTHER
TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. REPLACE ALL EXISTING STRIPE AND
PAVEMENT MARKINGS WITH THERMOPLASTIC UNLESS OTHERWISE DIRECTED.
IN
35. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALKS AFFECTED BY THE
CONSTRUCTION TO THE SATISFACTION OF THE CITY ENGINEER
36. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE
RECORD DRAWINGS TO THE CITY ENGINEER.
E
a
Under round Service Alert CITY OF FONTANA,CALIFORNIA
Esse SUBMITTED BY: DATE: Jv Leo ZOb�
SECTION 4216/4217 OF THE GOVERNMENT F -� SHOULD CONSTRUCTION OF THE REQUIRED PAVEMENT REHABILITATION PROJECT
FORE CODE REQUIRES A DIG ALERT IDENTIFICATION RF IMPROVEMENTS NOT COMMENCE WITHIN TWO
NUMBER BE ISSUED BEFORE A PERMIT TO `_'' c L.D. KING, INC. YEARS OF THE DATE OF APPROVAL SHOWN DRAWN BY GENERAL NOTES SCA
EXCAVATE WILL BE VALID No. 16434 2 Lr)4cin 2151 CONVENTION CENTER WAY HEREON AND CARRIED FORTH IN A DILIGENT MSM LE: N.T.S. 04
EXP. 6/30/05 SUITE 1008 MANNER THE CITY ENGINEER MAY REQUIRE DESIGNED BY ONSTRUCTION NOTES DATE:
FOR YOUR DIG ALERT I.D. NUMBER CALL �, �. ONTARIO, CA 91764
UNDERGROUND SERVICE ALERT '9 ��� (909) 937-0200 REVISIONS TO THE PLANS TO BRING THEM � ANU 7/16/01
TOLL FREE 1-800-227-2600 ca�-�F INTO CONFORMANCE WITH CONDITIONS AND CHECKED BY APP 0 BY: DATE. DRAWING NO.. 2
CARL J. FREEMA R.C.E. No. 16434 STANDARDS fN EFFECT.4-1
TWO WORKING DAYS BEFORE YOU DIG REV. REVISION DESCRIPTION DATE ENGR. CITY DATE EXPIRES: 6/30/05 DEW 294912
TY ENGINEER R.C.E. No. 115
124-09-506
1135-R