HomeMy WebLinkAbout2939-1GENERAL NOTES -STORM DRAIN
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF
FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD
SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL
REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION
UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT
DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE
PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY
REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE
CITY ENGINEER.
4. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL
BE IN PLACE ONE WEEK PRIOR TO IMPLEMENTING DETOURS.
5. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA
COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE
START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT
LEAST TWO WORKING DAYS PRIOR TO THE STARt OF ANY WORK IN PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
6. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES,
METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL
OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE
DIRECTED BY THE CITY TRAFFIC ENGINEER.
7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN
BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL
TIMES.
8. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR
TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE
CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
9. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET
IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR
OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION
OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN
FIVE (5) FEET SHALL ALSO BE GRADED WHEN THE POTENTIAL EXISTS FOR
GROUND MOVEMENT.
10. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF
WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE.
11. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM
AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND
ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION
TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND
SERVICE ALERT AT 1-800-226-2700 TWO WORKING DAYS BEFORE
EXCAVATION.
12. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY
COMPANIES INCLUDING, BUT NOT LIMITED TO GAS, TELEPHONE, ELECTRIC,
CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER,
RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS.
ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR
TO WORK AROUND THEIR FACILITIES.
13. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER
MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR
SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE
OPERATION AND WATER REQUIREMENTS.
14. STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE
OTHERWISE NOTED.
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE
ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE
PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE
PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING
CONSTRUCTION.
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS,
MONUMENT TIES OR BENCHMARKS WITHOUT PRIOR NOTIFICATION TO THE CITY
ENGINEER.
17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING
SURVEY MONUMENTS, MONUMENT TIES AND BENCHMARKS, SHALL BE DONE BY
A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY
MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION
SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE
WEEK PRIOR TO CONSTRUCTION ST THAT TIES TO MONUMENTS CAN BE
ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND
BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED
AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY
VEHICLES.
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF
DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES.
20. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT
OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT
TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN
APPROVAL.
21. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF
THE CITY INSPECTOR.
22. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION.
FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF
THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
23. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES
FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE,
THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES
ENTERING OR LEAVING IMPROVEMENTS.
24. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR
Q AND FINISH TO MATCH EXISTING CONCRETE.
- 25. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT
D PRIOR APPROVAL OF THE CITY ENGINEER.
V
UndergroUnd Service Alert SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS
NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF
.. o Y° o Call TOLL FREE APPROVAL SHOWN HEREON AND CARRIED FORTH IN A
DILIGENT MANNER THE CITY ENGINEER MAY REQUIRE
1-800 REVISIONS TO THE PLANS TO BRING THEM INTO
LCONFORMANCE WITH CONDITIONS AND STANDARDS
'' �
227-2600 IN EFFECT.
TWO WORKING DAYS BEFORE YOU DIG
CITY OF FONTANA
STORM DRAIN PLANS
I m 11 0
1 1000 11
I a _YMAX" W m [oil WA f4o-
.OJWI�zlS PREPARED FOR
26. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING
FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY
APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY
CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
27. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE
PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER
AND ALL AFFECTED AGENCIES IMMEDIATELY.
28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING
STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED.
29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED
PRIOR TO PAVING OF STREETS.
30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT
PAVEMENT PRIOR TO PLACEMENT.
31. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE
RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION
OF PAVING.
32. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESORE ALL
SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO
THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
33. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE
ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY
ENGINEER.
FORECAST HOMES ��
10670 CIVIC CENTER DRIVE
RANCHO CUCAMONGA, CA 91730
(909) 987-7788
(909) 987-1169
BU/C % "
REVISIONS
Engineer City
Approval Date: Approval Date:
SCALE: 1 "=100'
BENCHMARK
60 ! Le .I i& L111 :4 ► Lei 101 a WA
BRASS CAP IN CONCRETE S.C.E. TOWER LEG.
343' N/0 HIGHLAND AVE., 0.2 MI. W/O SAN
SEVAINE RD., IN SOUTH CONCRETE BASE OF
S.C.E. TOWER 19.5; 2.65 MI. W. ALONG
HIGHLAND AVE. FROM SIERRA AVE.
ELEVATION 1428.6090
E
VICINITY MAP
N.T.S.
'ROJECT
_OCATION
CITY OF FONTANA
PACIFIC BELL CO.
ATTN: CARLOS NAVARRO
ATTN: VIRGINIA BECKER
8353 SIERRA AVENUE
3939 E. CORONADO STREET
FONTANA, CA. 92335
ANAHEIM, CA. 92807
(909) 350-6632
(714) 666-5467
SO. CALIF. GAS COMPANY
UNDERGROUND SERVICE ALERT
ATTN: DENNIS FREEMAN
(800) 227-2600
1981 W. LUGONIA AVENUE
LF
REDLANDS, CA. 92374
COMCAST ( CABLE TV )
(909) 335-7547
ATTN: JACK HAYES
EMERGENCIES: (800) 427-2200
1205 DUPONT AVE.
3
ONTARIO, CA. 91761
SO. CALIF. EDISON COMPANY
(909) 390-4738
300 N. PEPPER AVENUE
EA.
RIALTO, CA. 92376
GENERAL TELEPHONE COMPANY
909 820-5598 - UNDERGROUND
ATTN: STEVE HOCK
909 875-5100 - TRANSMISSION
1400 E. PHILIPS BLVD.
213 637-1233 - PIPELINES
ONTARIO, CA. 91766
909 357-6223 - DISTRIBUTION
(800) 422-4133
800 227-2600
EA.
11
FONTANA WATER COMPANY
CRAWFORD CANYON MUTUAL WATER CO.
ATTN: MICHAEL J. McGRAW
ATTN: BILL VANDERKIEFT, JR.
8440 NUEVO AVENUE
(619) 868-6040
FONTANA CA. 92235
(909) 822-2201
150
FAX: (909) 823-5046
STORM DRAIN CONSTRUC11ON NOTES ESTIMATE OF OUAN Trl
1
INSTALL 42" RCP, 1350-D
216.27
LF
2
INSTALL 36" RCP, 1350-D
464.88
LF
3
INSTALL 24" RCP, 1350-D
261.12
LF
4
INSTALL 18" RCP, 1350-D
55.59
LF
5
CONSTRUCT MANHOLE PER APWA STD. DWG. NO. 320-1, AS SHOWN ON SHEET 4
2
EA.
6
CONSTRUCT JUNCTION STRUCTURE PER APWA STD. DWG. NO. 331-2, AS SHOWN ON SHEET 3
3
EA.
7
REMOVE EXISTING TEMPORARY BULKHEAD
1
EA.
8
CONSTRUCT BRICK AND MORTAR BULKHEAD
2
EA.
9
INSTALL 18" CMP
22.7
LF
10
CONSTRUCT TEMPORARY CMP RISER PER CALTRANS STD. D93C, TYPE B, AS SHOWN ON SHEET 3
2
EA.
11
REMOVE EXISTING A.C. PAVEMENT AND REPLACE WITH 6.5" A.C.
2,800
S.F.
@-CONSTRUCT
PAVEMENT OVER 12" OF 95% COMPACTED NATIVE PER CITY STD. DWG. N0. 131.
3" A.C. PAVEMENT
150
S.F.
I? Of ESS / pN
No. 36052 m
m
Exp. 6/30/2004
F pF CAO
BEARINGS SHOWN ON THESE PLANS ARE BASED
ON THE WEST LINE OF THE NORTHWEST QUARTER
OF SECTION 35, T1 N, R6W, SBM, AS SHOWN ON
TRACT NO. 16046-1, M.B. 278/45, O.R.
BEING: N 0012'46" E
Prepared By:
ALLARD ENGINEERING
Civil Engineering - Land Surveying - Land Planning
8253 Sierra Avenue
Fontana, California 92335
(909) 356-1815 Fax (909) 356-1795
ggj 4 1- �4� �-Z5-V!
Raymond J. Allard, A.C.E. 36052 Date
(expires 6/30/2004)
CITY OF FONTANA, CALIFORNIA
STORM DRAIN PLANS
Drawn By: TRACT NO. 16078 Scale:
AS NOTED
Designed By: TITLE SHEET Date:
DBW�(' - 2001
Checked By0-7
Approved:Fall"� �"LO�"`� 4'0964 Dwg. No. �
RD R�CIN ENGINEER R.C.E..ralaa2 ZM 4
Filename: M:\DWG\16001 \STORM DRAIN\SHTI.DWG