Loading...
HomeMy WebLinkAbout2939-1GENERAL NOTES -STORM DRAIN 1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE WEEK PRIOR TO IMPLEMENTING DETOURS. 5. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE STARt OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 6. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 8. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 9. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GRADED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 10. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 11. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-226-2700 TWO WORKING DAYS BEFORE EXCAVATION. 12. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 13. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 14. STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED. 15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCHMARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCHMARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION ST THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 20. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 21. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 22. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 23. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 24. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR Q AND FINISH TO MATCH EXISTING CONCRETE. - 25. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT D PRIOR APPROVAL OF THE CITY ENGINEER. V UndergroUnd Service Alert SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF .. o Y° o Call TOLL FREE APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER THE CITY ENGINEER MAY REQUIRE 1-800 REVISIONS TO THE PLANS TO BRING THEM INTO LCONFORMANCE WITH CONDITIONS AND STANDARDS '' � 227-2600 IN EFFECT. TWO WORKING DAYS BEFORE YOU DIG CITY OF FONTANA STORM DRAIN PLANS I m 11 0 1 1000 11 I a _YMAX" W m [oil WA f4o- .OJWI�zlS PREPARED FOR 26. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 27. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 31. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 32. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 33. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. FORECAST HOMES �� 10670 CIVIC CENTER DRIVE RANCHO CUCAMONGA, CA 91730 (909) 987-7788 (909) 987-1169 BU/C % " REVISIONS Engineer City Approval Date: Approval Date: SCALE: 1 "=100' BENCHMARK 60 ! Le .I i& L111 :4 ► Lei 101 a WA BRASS CAP IN CONCRETE S.C.E. TOWER LEG. 343' N/0 HIGHLAND AVE., 0.2 MI. W/O SAN SEVAINE RD., IN SOUTH CONCRETE BASE OF S.C.E. TOWER 19.5; 2.65 MI. W. ALONG HIGHLAND AVE. FROM SIERRA AVE. ELEVATION 1428.6090 E VICINITY MAP N.T.S. 'ROJECT _OCATION CITY OF FONTANA PACIFIC BELL CO. ATTN: CARLOS NAVARRO ATTN: VIRGINIA BECKER 8353 SIERRA AVENUE 3939 E. CORONADO STREET FONTANA, CA. 92335 ANAHEIM, CA. 92807 (909) 350-6632 (714) 666-5467 SO. CALIF. GAS COMPANY UNDERGROUND SERVICE ALERT ATTN: DENNIS FREEMAN (800) 227-2600 1981 W. LUGONIA AVENUE LF REDLANDS, CA. 92374 COMCAST ( CABLE TV ) (909) 335-7547 ATTN: JACK HAYES EMERGENCIES: (800) 427-2200 1205 DUPONT AVE. 3 ONTARIO, CA. 91761 SO. CALIF. EDISON COMPANY (909) 390-4738 300 N. PEPPER AVENUE EA. RIALTO, CA. 92376 GENERAL TELEPHONE COMPANY 909 820-5598 - UNDERGROUND ATTN: STEVE HOCK 909 875-5100 - TRANSMISSION 1400 E. PHILIPS BLVD. 213 637-1233 - PIPELINES ONTARIO, CA. 91766 909 357-6223 - DISTRIBUTION (800) 422-4133 800 227-2600 EA. 11 FONTANA WATER COMPANY CRAWFORD CANYON MUTUAL WATER CO. ATTN: MICHAEL J. McGRAW ATTN: BILL VANDERKIEFT, JR. 8440 NUEVO AVENUE (619) 868-6040 FONTANA CA. 92235 (909) 822-2201 150 FAX: (909) 823-5046 STORM DRAIN CONSTRUC11ON NOTES ESTIMATE OF OUAN Trl 1 INSTALL 42" RCP, 1350-D 216.27 LF 2 INSTALL 36" RCP, 1350-D 464.88 LF 3 INSTALL 24" RCP, 1350-D 261.12 LF 4 INSTALL 18" RCP, 1350-D 55.59 LF 5 CONSTRUCT MANHOLE PER APWA STD. DWG. NO. 320-1, AS SHOWN ON SHEET 4 2 EA. 6 CONSTRUCT JUNCTION STRUCTURE PER APWA STD. DWG. NO. 331-2, AS SHOWN ON SHEET 3 3 EA. 7 REMOVE EXISTING TEMPORARY BULKHEAD 1 EA. 8 CONSTRUCT BRICK AND MORTAR BULKHEAD 2 EA. 9 INSTALL 18" CMP 22.7 LF 10 CONSTRUCT TEMPORARY CMP RISER PER CALTRANS STD. D93C, TYPE B, AS SHOWN ON SHEET 3 2 EA. 11 REMOVE EXISTING A.C. PAVEMENT AND REPLACE WITH 6.5" A.C. 2,800 S.F. @-CONSTRUCT PAVEMENT OVER 12" OF 95% COMPACTED NATIVE PER CITY STD. DWG. N0. 131. 3" A.C. PAVEMENT 150 S.F. I? Of ESS / pN No. 36052 m m Exp. 6/30/2004 F pF CAO BEARINGS SHOWN ON THESE PLANS ARE BASED ON THE WEST LINE OF THE NORTHWEST QUARTER OF SECTION 35, T1 N, R6W, SBM, AS SHOWN ON TRACT NO. 16046-1, M.B. 278/45, O.R. BEING: N 0012'46" E Prepared By: ALLARD ENGINEERING Civil Engineering - Land Surveying - Land Planning 8253 Sierra Avenue Fontana, California 92335 (909) 356-1815 Fax (909) 356-1795 ggj 4 1- �4� �-Z5-V! Raymond J. Allard, A.C.E. 36052 Date (expires 6/30/2004) CITY OF FONTANA, CALIFORNIA STORM DRAIN PLANS Drawn By: TRACT NO. 16078 Scale: AS NOTED Designed By: TITLE SHEET Date: DBW�(' - 2001 Checked By0-7 Approved:Fall"� �"LO�"`� 4'0964 Dwg. No. � RD R�CIN ENGINEER R.C.E..ralaa2 ZM 4 Filename: M:\DWG\16001 \STORM DRAIN\SHTI.DWG