HomeMy WebLinkAbout2826-1CONDUCTOR TABLE DIAGRAM CIRCUIT OR RUNS 1 2 3 4 5 6 7 8 C rr PHASE 5 AWG. POLE PHASE 8 POLE PHASE QUAD VEHICLE PED. PHASE MESSAGE A B A 19-2-80 1 30' POLE OB 15' 250 W 2 B 6 8 1-1 1-1 1-1 1-1 3 Beech Ave, 17' 4' W POLE 1 10' — — — B 8 S TV -1— T SP-1—CS 8 — 30 4' C 19-4-80 1 30' 1 25' 15' 250 W B 8 S M Q POLE OD — 1-1 1-1 1-1 D 26-4-80 1 30' 45' 15 250 W U 2 W MAS, MAS, SV -1—T SP-1—CS 3 Baseline Ave. 4 48' 4' o POLE �E F— -10 — — — — — — — — — — — U N POLE OF i � POLE �G CH z O — — POLE 0 TOTAL 1-1 2-2 3-3 3-3 1-1 1-1 1-1 1-1 #10 LUMINAIRE 1 2 1 2 2 1 1 1 2 = VIDEO CABLE 1 1 2 2 VIDEO SVC 1 1 2 2 04 DLC 06 DLC oc� 07 DLC OPTICOM CABLE 1 1 2 2 CONDUIT SIZE 3" 1 3" 3" 1 3" 1 3" 3" 3"(E) 3" NOTE: ALL CONDUITS ARE NEW UNLESS SHOWN OTHERWISE (E) = EXISTING BASELINE BARRIER PHASE DIAGRAM STANDARD ARMS LUMINAIRE PED PUSH PHASE 1 PHASE 2 PHASE 3 PHASE 4 PLACEMENT REMARKS C rr PHASE 5 PHASE 6 PHASE 7 PHASE 8 2" C., 2 #6 2" C., 2 #10 LIGHTING. — — — — — — — — FUT. 66' R/W — — — — FUT. CBcG @ 54' EXISTING R/W SERVICE POINT PER S.C.E. 15 2' W I ,I 31' f I — 44'I 4 W I I��h I I Ilh I I I 7 I { I II 1 II I P 0 L E S C H E D U L E L STANDARD ARMS LUMINAIRE PED PUSH BT. SIGNAL MOUNTING PED. S.N.S. PLACEMENT REMARKS C TYPE HT. SIG. LUM. H.P.S.V. TYPE PHASE QUAD VEHICLE PED. PHASE MESSAGE A B A 19-2-80 1 30' 25 15' 250 W 2 B 6 8 E N MAS, SV -1-T SP -2 -CS 6/8 3 Beech Ave, 17' 4' B1—A 1 10' — — — B 8 S TV -1— T SP-1—CS 8 — 30 4' C 19-4-80 1 30' 1 25' 15' 250 W B 8 S MAS, MAS, SV -1—T — — 3 Beech Ave. 4 20' 4' D 26-4-80 1 30' 45' 15 250 W B 2 W MAS, MAS, SV -1—T SP-1—CS 3 Baseline Ave. 4 48' 4' F— -10 — — — — — — — — — — — — — CH — — I ( (1) = CITY PROVIDED POLES (2) 2 EACH (3) Pale shaft mounted (4) Distance as noted on Plan � I I I I II II - � I I I I I I c~n X Wo' w I D SCA L E• 1 "= 20' INSTALL TRAFFIC COVER I , 20 10 0 20 40 60 "'I I I a 6E �{ I fi i� ], AVEN U E BC CB e 4 IISIII FUT. 66 R/W CB Ln �` `,� ; II 11 6T 1?11 1 / OA , i �. �, , 11 11 B i II II 3 08 MH � I I .01 08— 07 — EXISTING R/W EXIST. DRAIN AP r 6 �' �-----------------------„_----,.,_�_�1_, - -- LD 31' 1 18 L--------------------------------- 1 1 1 — — 21” s M H r2 1 07 — ----------------------------------------- --— — � 6 21" S — — — 21" S — — 21" S — — 21" S — — 21" S 20.5' 1 1 t06 5 WV 106P 1 WVez 4 1 20"W 2011w 20"W 20"W — — — _ 4„G 4„G-04 G = _ _ _ _ 1- 4"G 17 ST&C"W 17 STg 17 ST&C"W HEADER CUT 1' 1' EXISTING 0.10' MIN. AC SURFACING TACK COAT COMPLETE SURFACE BEING PAVED NEW A. C. 3—SACK CONCRETE BACKFILL (CLSM) (INITIAL POUR TO BE FLUSH �.- WITH SURROUNDING SURFACE) RIGID METAL CONDUIT (INSTALLED WITH 18" MIN. COVER) TRENCH REPAIR DETAIL N.T.S. EXISTING R/W 4"G 4"G C 12"W 12"W 12"W _ 11®&C , ® 26„W 26"W 26"W 26"W D WV 48' EXISTING R/W CAUTION!!! POSSIBLE UTILITY CONFLICT CONTRACTOR SHALL HAND—DIG TO DETERMINE PRECISE LOCATION PRIOR TO DRILLING SIGNAL._ CONSTRUCTION NOTES F1 INSTALL CITY FURNISHED TYPE 90 CONTROLLER ASSEMBLY, INCLUDING TYPE "P" CABINET, AUTOSCOPE DETECTION, AND APPURTENANT EQUIPMENT (SEE SPECIAL PROVISIONS). CONTROLLER CABINET AND FOUNDATION TO BE INSTALLED PER CITY STANDARD 134. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECTRONIC EQUIPMENT REQUIRED TO PROVIDE THE DESIRED SIGNAL OPERATION AS SHOWN ON THE PLAN. F2 INSTALL CITY FURNISHED TYPE III—BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND SOUTHERN CALIFORNIA EDISON REQUIRMENTS (SEE SPECIAL PROVISIONS). 30 FURNISH AND INSTALL 3” PVC CONDUIT WITH 2 #2, 1 #4 AND 36" PVC SCHEDULE 80 SWEEP FROM ELECTRICAL SERVICE POINT TO SERVICE ENCLOSURE PER EDISON REQUIREMENTS. [_4] INSTALL POLE AS NOTED ON POLE SCHEDULE ON EXISTING FOUNDATION. a5 INSTALL IMAGE SENSOR UNIT PER CITY STANDARD DRAWING 133 AND AS DIRECTED BY ENGINEER. © FURNISH AND INSTALL R96/R9613 SIGN AND HARDWARE ON SIGNAL POLE AS SHOWN. ❑7 NOT USED ® EXISTING LUMINAIRE AND UTILITY POLE (LP #4132757E) TO BE REMOVED (BY SCE). [�]NOT USED idly .c�. TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT 20' SIGNAL GENERAL NOTES: 1. TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 1992) 2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS. PHONE UNDERGROUND SERVICE ALERT AT 800/227-2600, TWO (2) WORKING DAYS BEFORE DIGGING. 3. ALL PULL BOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID METAL EXCEPT WHERE NOTED OTHERWISE. ALL VEHICLE HEADS SHALL BE PER SPECIAL PROVISIONS. 4. CONTRACTOR SHALL COORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING WITH THE SOUTHERN CALIFORNIA EDISON COMPANY WELL IN ADVANCE OF NEED. 5. EXISTING LIGHTING SHALL REMAIN IN OPERATION UNTIL NEW SIGNAL AND LIGHTING IS OPERATIONAL PER SPECIFICATIONS. 6. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. 7. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALK AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER. 8. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY SPRINKLER SYSTEMS IF NECESSARY. 9. CONTRACTOR SHALL REFER TO THE CITY TRAFFIC ENGINEER IN THE EVENT OF A CONFLICT OR POTENTIAL CONFLICT WITH THESE PLANS AND/OR SPECIFICATIONS FOR THIS PROJECT. 10. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF WORK. 11. WHERE TRAFFIC SIGNAL STREET CROSSING CONDUITS ARE NOT INSTALLED USING THE BORING METHOD, TRENCH REPAIRS SHALL BE PER DETAIL THIS SHEET, AND SPECIAL PROVISIONS, SECTION E. Curb/Berm flow lir or edge of shouldi Typical signal placement unless dimensions noted on plans. NOTE: 1. For "A"8c"B" dimensions refer to Pole Schedule, or as directed by the Engineer. Negative "A" dimensions refer to a distance departing intersection away from BC or EC. SIGNAL STANDARD PLACEMENT DIMENSIONS 8c EQUIPMENT LOCATIONS mom No Q z rD; W' LL LL_ Q AUTOCAD FILENAME: Baseline and Beech—TS—VIDEO—FINAL—PLOT4-19—OO.dw