HomeMy WebLinkAbout2823-1CONDUCTOR TABLE ■ o CIRCUIT OR RUNS 1 2 3 4 5 6 7 8 AWG. POLE H.P.S.V. POLE OA HEADS (2), PPB, VIDEO IMAGE DETECTOR, Q 2. LOCATIONS OF ALL UNDERGROUND UTILITITES ARE APPROXIMATE. THE CONTRACTOR SHALL QUAD VEHICLE PED. MESSAGE A 1-1 A DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE. AND SNS TO LOCO W POLE OB 45' 15' 250 W B[R] 1-1 1-1 MAS -2, SV -1—T SP-1—CS Sierra Ave[R] POLE OC 5.5' B 1—A 1-1 1-1 1-1 — B[R] w J S TV -1—T SP -1 -CS - 11.5' 5.5' C 26-4-80 30' 45' POLE OD 250 W B[R] 1-1 1-1 1-1 1-1 Merrill Ave[R] — 0.5' 9.0' D 1—A[R] 10' — — — B[R] 2P W o POLE OE — 1-1 1-1 1-i 1-1 1-1 45' 15' 250 W B[R] 2P W MAS -2, SV -1—T SP-1—CS Sierra Ave[R] 0.0' 10.5' F U POLE OF 1-1 1-1 1-1 1-1 1-1 1-1 TV-2—TA SP-1—CS N —0.5' 7.0' G29-5-80 30' 50' 15' 250 W B[R] z POLE MAS -2, SV -1—T SP-1—CS Merrill Ave[R] —1.5' 11.5' H 1—A[R] 0 10' — — — B[R] 6P E TV -1—T POLE — — 2.0' 5.5' TOTAL 1-1 2-2 3-3 4-4 5-5 5-5 3-3 2-2 #10 LUMINAIRE 2 2 2 2 2 VIDEO VIDEO CABLE 1 1 2 2 2 2 1 DET. VIDEO SVC 1 1 2 2 2 2 1 OPTICOM CABLE 1 1 2 2 2 2 1 CONDUIT SIZE 2" 3" 3" 3" 3" 3" 3" 3" ■ - ALL CONDUIT, CABLE, AND CONDUCTORS ARE NEW. SCALE: 1"=20' 20 10 0 20 40 60 JJ4:4:4111111114 AC PARKING I I I II I ulII I I II I LU II I d IN02 I li v RC POLE AND BASE COMPLETE EXCEPT RL PPB TO LOC © 70' I 12' ' 28 i II RS POLE COMPLETE EXCEPT FRL] 12" VEH 1 HEADS(2),PPB VIDEO IMAGE DETECTOR ' AND SNS TO LOCO B ❑ i i I JI I PB(2) RC 5" PROPOSED SERVICE FEED POINT Ly RC EX. TYPE I SERVICE 6 4 6 l ON N QUAD OF UP A zl A EX. R W 708P ��\,--------- -� 6E ST BACK OF WALKAir \ t� - J - EOO�I -- -- L SOH - 08 05 05 CURB & GUTTER 2"C, INSTALL 2#6(SIG) " 2"C, INSTALL 2#10(LUM) CURB E X . 1.5" C, 1 SIC - -- ---- -- - T - ------ " - - - - - - (TO T.S. CONTROLLER 5 CB AT JUNIPER/MERRILL) LO P13 RC ----------------- -------------- 08 _ -� 2 c+ I� c i - , w 7 w r - 2"G 2„G ----- -- ZG-- ' ' -------------------------------- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ----- - - - - -- ----------- ---- L ra } ra I �/ -------------------------------------- -------------------------- + 12"W -- "12"W -- - _ -- - ---- 12-W ------------- i - -- 12"W_ 0L LO RL POLE COMPLETE TO LOC OH , I CURB & GUTTER PROTECT EX. FH IN PLACES , CF 5CP� 04 25"W 25"W - 25 r 00 A06 C-------- --- - - -- ------ --1-- \, 04P 06 EX. R/W & BACK OF WALK R20 � I PB RC � I II I- I II I II I I I I TRAFFIC SIGNAL GENERAL NOTES o STANDARD v 2 111� LUMINAIRE PED PUSH BT. SIGNAL MOUNTING S.N.S. 1. TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA STANDARD [RL]12" VEH RSPOLE COMPLETE EXCEPT PHASE 4 TYPE HT. SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 1992) LUM. H.P.S.V. HEADS (2), PPB, VIDEO IMAGE DETECTOR, Q 2. LOCATIONS OF ALL UNDERGROUND UTILITITES ARE APPROXIMATE. THE CONTRACTOR SHALL QUAD VEHICLE PED. MESSAGE A B A DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE. AND SNS TO LOCO W I 45' 15' HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS. PHONE UNDERGROUND SERVICE ALERT AT (800) 227-2600, 48 HOURS BEFORE DIGGING. 3. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID METAL EXCEPT AS SHOWN. ALL VEHICLE HEADS SHALL BE METALLIC WITH ALL 12" LENSES, AND METALLIC LOUVERED BACKPLATES. 4. CONTRACTOR SHALL COORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING WITH THE SOUTHERN CALIFORNIA EDISON COMPANY WELL IN ADVANCE OF NEED. 5. EXISTING LIGHTING TO BE REMOVED SHALL REMAIN IN OPERATION UNTIL NEW LIGHTING IS OPERATIONAL, SEE SPECIAL PROVISIONS. 6. EXACT LOCATION OF EQUIPMENT IS SUBJECT TO APPROVAL OF THE ENGINEER. 7. THE CONTRACTOR SHALL RELOCATE OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALK AFFECTED BY CONSTRUCTION PER SPECIAL PROVISIONS AND TO THE SATISFACTION OF THE ENGINEER. 8. CONTROLLER SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY SPRINKLER SYSTEMS, IF NECESSARY, PER SPECIAL PROVISIONS. 9. ALL CONDUITS NOT SHOWN FOR RE -USE SHALL BE PROTECTED IN PLACE. 10. CONTROLLER FOUNDATION AND ALL EXISTING TRAFFIC SIGNAL POLE FOUNDATIONS SHALL BE REMOVED PER SPECIAL PROVISIONS. T_ 0 w POLE SCHEDULE ■ o STANDARD MASTARMS LUMINAIRE PED PUSH BT. SIGNAL MOUNTING S.N.S. PLACEMENT PER DETAIL A PHASE 4 TYPE HT. SIG. LUM. H.P.S.V. TYPE PHASE QUAD VEHICLE PED. MESSAGE A B A 26-4-80 30' 45' 15' 250 W B[R] 6P E MAS -2, SV -1—T SP-1—CS Sierra Ave[R] 7.5' 5.5' B 1—A 10 — — — B[R] 8P S TV -1—T SP -1 -CS - 11.5' 5.5' C 26-4-80 30' 45' 15' 250 W B[R] 8P S MRS -2, SV -1—T SP-1—CS Merrill Ave[R] — 0.5' 9.0' D 1—A[R] 10' — — — B[R] 2P W TV -1—T SP-1—CS — 0.5' 6.0' E 26-4-80 30' 45' 15' 250 W B[R] 2P W MAS -2, SV -1—T SP-1—CS Sierra Ave[R] 0.0' 10.5' F 1—A[R] 10' — — — B[R] 4P N TV-2—TA SP-1—CS — —0.5' 7.0' G29-5-80 30' 50' 15' 250 W B[R] 4P N MAS -2, SV -1—T SP-1—CS Merrill Ave[R] —1.5' 11.5' H 1—A[R] 10' — — — B[R] 6P E TV -1—T SP-1—CS — — 2.0' 5.5' ■ - ALL EQUIPMENT IS NEW UNLESS OTHERWISE NOTED: [R] - RELOCATED F POLE COMPLETE EXCEPT FRL] 12" VEH HEADS (2), PPB, VIDEO IMAGE DETECTOR, AND SNS TO LOC E POLE COMPLETE TO LOC O BARRIER PHASE DIAGRAM I III 1 I 1 I I PHASE 1 PHASE 2 PHASE 3 PHASE 4 I I 1 m PHASE 5 PHASE 6 PHASE 7 PHASE 8 �8P © EX. R/W i c b 171- �, � BACK OF WALK CURB & GUT TER I 0 I � G --- 12"w 0 [RS]POLE COMPLETE EXCEPT RL 12" VEH HEADS (2), PPB, VIDEO IMAGE DETECTOR, AND SNS TO LOC O POLE COMPLETE TO LOC FO AVENUE Curb return, flow or edge of should( INS1611011 w DETAIL "A" 77 O 3"G 25,.,E CURB & GUTTER BACK OF WALK EX. R/W O I III I I I m II I LEGEND ii i i1 � ;; 39' 15'35 IX 10' Q 0-0. PROPOSED OPTICOM DETECTOR INSTALLED PER DETAIL "B" 1 1 I I I I � � 74' , , ` I �n _KI ' -' RELOCATED VIDEO IMAGE DETECTOR Ly cb I � � � IIi EXISTING RED CURB "QD\ m V ULTIMATE CURB RETURN 'U U II I m CONSTRUCTION NOTES 11 MAST -ARM MOUNTING CLAMP FOR MODEL 711 OPTICAL DETECTOR DETAIL 991) ❑1 REPLACE ALL EXISTING BALL LENSES IN RELOCATED VEH HEAD WITH LEFT -ARROW LENSES. [RSEXISTING TRAFFIC SIGNAL CONTROLLER CABINET COMPLETE. INSTALL CITY FURNISHED TYPE 90 CONTROLLER PACKAGE INCLUDING TYPE "P" CABINET, AUTOSCOPE DETECTION, AND APPURTENANT EQUIPMENT (SEE SPECIAL PROVISIONS). CONTRACTOR SHALL COORDINATE WITH PACIFIC BELL TO DETERMINE EXISTING TELEPHONE SERVICE FEED POINT. ❑3 SAWCUT AND REMOVE HERRINGBONE PATTERN (4' x 8') IN EXISTING CURB ACCESS RAMP (INCLUDING TRAFFIC SIGNAL PULL BOX.) INSTALL CONCRETE TO RECONSTRUCT THE RAMP TO THE SATISFACTION OF THE ENGINEER IN THE FIELD. F4] INSTALL CITY -FURNISHED TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND EDISON REQUIREMENTS. (SEE SPECIAL PROVISIONS) 0 REMOVE SIC CONDUCTORS FROM THE EXISTING CONDUIT TO THE EXISTING CONTROLLER CABINET AND REPULL INTO PROPOSED SIGNAL CONTROLLER CABINET THROUGH NEW CONDUIT AS SHOWN. CONNECT PER TRAFFIC SIGNAL CONTROLLER MANUFACTURER'S REQUIREMENTS. © INSTALL 3” SCH. 80 PVC CONDUIT, PULLROPE, AND RISER PER SOUTHERN CALIFORNIA EDISON REQUIREMENTS. [7] FURNISH AND INSTALL MODEL 711 UNI -DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR PER DETAIL "B" THIS SHEET, AND AS DIRECTED BY THE ENGINEER (SEE SPECIAL PROVISIONS). Sierra_Merri11Signa12. dwq