Loading...
HomeMy WebLinkAbout2814-1CONDUCTOR SCHEDULE A.W.G. size p4L.E OR RUNS NON -ILLUMINATED STREET NAME SIO CABERSIZE CIRCUITz�p 10' ap 4' 4' �,�OppAp TV- 1-T SP -1 -CS 8 ---•- -S -- - POLE UA 1 1 1 1 1 MAS - SV -1-T SP -1 -CS 6 •-1----- E 250W Cherry Ave 1 1 1 1 1 D 29A-5-80 35 50 15' 2' 4' 0 3 POLE OB SP -1 -CS 1 1 1 1 Heritage iii ctr E 1-A 10 -_ 7' C - TV- 1-T 1 1 1 1 - - F 19A-4-80 35 _30' 15' POLE OC1 4' MAS SV -1-T 1 1p -m*— --- W 250W Cherry Ave G 1-A N 0 Nt 6' 4' - TV- 1-T � � W -- - F9_1 29A--5-80 35' 50' 15' 5' 4' 3/MAS SV -1-T SP -1 -CS 8 S 25OW Bar Harbor Rd U p POLE T c POLE R12 0 1 t 1 POLE S R S POLE POLE OH , Xi , , , TOTAL CABLES 3C/12C � 1 2 2 3 3 4 4 4 4 1 1 2 2 3 3 4 4 4 4 4 4 'T8—= LUMINAIRES - 2 2 2 - 2 2 2 2 2 - VIDEO COAXIAL CABLE - 1 1 2 2 1 1 2 2 2 2 VIDEO POWER CABLE - 1 1 2 2 1 1 2 2 2 2 OPTICOM CABLE - 1 1 2 2 1 1 1 2 2 2 2 CONDUIT SIZE {in.) 2� 3 3 3. 3 3 3 3 3 3 1 3 EMERGENCY VEHICLE, PREEMPTION DETECTOR 1 1/200 TO 3/4" REDUCER ASTRO Nlini-Brae MOUNT PELCO AB -121 0 r OR APPROVED EQUAL MAST -ARM MOUNTING CLAMP FOR MODEL 711 OPTICAL DETECTOR A S11111111 1 C LE 1. p 10 0 5 10 20 40 NEW C&G NEW C&G REVISED SOUTHWEST CCR ER OF ::";: BASELINE AVE. & CHERRY AVE. A tea _L ____► EXISTING" SCE ---� SERVICE POINT EXISTING CONTROLLER P.B. @ 200 0 , g N N� Ti LJ Z I I 1 2"C, SIC TO CONTROLLER J @ S/W CORNER OF i w BASELINE AVE, & CHERRY AVE, 3 SCHED. 40 PVC & PULL ROPE TO SCE SERVICE ON SW CORNER OF BASELINE AVE, 8c CHERRY AVE. rl r r� 08 I 1 RIO I � I^ I 1 L2- awl 08 I I I _T11 J GENERAL NOTES 1. All work and material shown on this plan shall conform to the State of California, Department of Transportation (CALTRANS) Standard Specifications and Standard Plans dated July 1992. 2. The city right -of way shall be kept clear of debris, with dust and other nuisances being controlled at all times. The Contractor shall be responsible for any clean up on city right-of-way affected by his consruction. The method of street cleaning shall be by dry sweeping ofall paved areas. There shallbe no stockpiling. of construction materials within the city right-of-way without permission on the Engineer. 3. The Contractor shall determine the exact location of all underground facilities and provide protection prior to and durin trenching, jacking or boring. Contact UNDERGROUND SERVICE ALERT (USA) at (80{ 227-2600, and all utility companies involved at least 48 hours before excavating. 4, The Contractor shall obtain a[l necessary permits. It shall be the Contractor's responsibility to coordinate all phases of construction with the various utility companies involved. 5. Final approval of poles, pull boxes, cabinet foundations and handicapped ramps shall be approved by the Engineer. 6. All pull boxes shall be No. 6 unless otherwise noted on the plan. 7. All vehicle heads shall be cast aluminum with 12" indications. All backplates shall be metallic and louvered. 8. Striping shall be by others. Mast arm signs shown on the plan shall be furnished by the Contractor. 9. All red vvehicle signal face sections shall be LED'S. AND GRF-F-N POLE NO- DESCRIPTION POLE AND EQUIPMENT PUSH PLACEMENT SIGNAL MOUNTING BUTTONS SIGNAL STANDARD DIMENSIONS BUTTONS POLE SIGNAL LUMINAIRE MAST ARM POLE POLE ARROW t�UAD HEIGHT MAST ARM MAST ARM "A'# "B" VEHICLE VEHICLE PEDESTRIAN 0 HPSV LUMINAIRE NON -ILLUMINATED STREET NAME SIO (A1 ­A 10' - - 4' 4' - TV- 1-T SP -1 -CS 8 ---•- -S -- - B C `19A-4-80 1-A 35' 10 25 15' 2' 2' 4' 4' MAS - SV -1-T SP -1 -CS 6 •-1----- E 250W Cherry Ave TV- 1-T SP -1 -CS 6 E -- - D 29A-5-80 35 50 15' 2' 4' 3/MAS SV -1-T SP -1 -CS 4-- N 250W Heritage iii ctr E 1-A 10 -_ 7' 4' - TV- 1-T SP -1 -CS 4 ----- N - - F 19A-4-80 35 _30' 15' 6' 4' MAS SV -1-T SP -1 -CS 2 -m*— --- W 250W Cherry Ave G 1-A 10 -~ --R 6' 4' - TV- 1-T SP -1 -CS 2 W -- - F9_1 29A--5-80 35' 50' 15' 5' 4' 3/MAS SV -1-T SP -1 -CS 8 S 25OW Bar Harbor Rd _ Curb/Berm flow lin 65 ; 601 or edge of shoulde I I _59'" 38'CY- r I i x 1! SIGNAL STANDARD PLACEMENT DIMENSIONS kA ;_ , AND EQUIPMENT LOCATIONS I i 52 02 i2 SWAM $5 [4� 4 4 )INT TRENCH yelp ?f'i y_``~.'`' 904'0 E 1_5 f ' jj !1Ak ' 3 ESC. PRIVATE SIGN- .0 16 06Alp Irl 01 I 1 (� i 1 !J/ 1 IF E - _ I I 7' o CONSTRUCTION NOTES Install TYPE 90 Controller equipment package including TYPE P Cabinet, Autoscope ' Detection, and appurtenant a uipment (See S ecial Provisions Controller cabinet and foundation to be installed per Cit Standard Drawing134. Contractor shall furnish and install any additional electronic equipment reuired to provide the desired o ` I signal operation as shown on the plan. ca r 0 c� 2 Furnish and install TYPE Ill -BF Service Equipment Enclosure per City of Fontana and I:. Southern California Edison Company requirements (See Special Provisions). Of 1 I 1 i I: z .6z r3� -- Install Image Sensor Unit per City Standard Drawing 133 and as directed by the z N ;�, 1 •-- I Z Engineer (See Special Provisions). �i X ; ; ' , ; ; :: I � ® Furnish and install unidirectional, single channel O ticom Detector, (Model 711 or X �' , , , 47 , �`' w equal), per detail this sheet and as directed by the Engineer (See Special Provisions), 6 � i 60' Furnish and install R73-3 sign per CALTRANS Standard ES -6T, Detail U. © Furnish and install R34 sign per CALTRANS Standard ES -6T, Detail U. Q7 Existing street light to be removed by others. NOT USED J� NOT ;USED �r o CONSTRUCTION NOTES Install TYPE 90 Controller equipment package including TYPE P Cabinet, Autoscope ' Detection, and appurtenant a uipment (See S ecial Provisions Controller cabinet and foundation to be installed per Cit Standard Drawing134. Contractor shall furnish and install any additional electronic equipment reuired to provide the desired o ` I signal operation as shown on the plan. ca r 0 c� 2 Furnish and install TYPE Ill -BF Service Equipment Enclosure per City of Fontana and I:. Southern California Edison Company requirements (See Special Provisions). Of 1 I 1 i I: z .6z r3� -- Install Image Sensor Unit per City Standard Drawing 133 and as directed by the z N ;�, 1 •-- I Z Engineer (See Special Provisions). �i X ; ; ' , ; ; :: I � ® Furnish and install unidirectional, single channel O ticom Detector, (Model 711 or X �' , , , 47 , �`' w equal), per detail this sheet and as directed by the Engineer (See Special Provisions), 6 � i 60' Furnish and install R73-3 sign per CALTRANS Standard ES -6T, Detail U. © Furnish and install R34 sign per CALTRANS Standard ES -6T, Detail U. Q7 Existing street light to be removed by others.