HomeMy WebLinkAbout2805-1A.W.G_ SIZE
CABLE SIZE
CIRCUIT OR
POLE NUMBER
1
1 1
1 1
1 -
-
-
TYPE B
04 DETECTOR
-
- -
- -
- 1
1
-
DETECTOR
LEAD—IN
06 DETECTOR
cnPOLE
2 2
2 -
-
-
08 DETEC OR
-
POLE
1 -
-
-
CABLE
2
2
2
00
N
U)
POLE
1
TOTAL
1
2 2 14
1 4
4
-/-/-
N
POLE/
B
N
4 N , 6(E)
MAS, SV-2—TAN
SP -2—T
-
n
POLE/
3
19-2-80*
30'
30'
15'
-
U
M
TOTAL
-/-/1
1 /1 /1 2/2/1
2/2/1
2/2/2
2/2/2 -/-/1
-/-/1
**
#10
02 DETECTOR
1
1 1
1 1
1 -
-
-
TYPE B
04 DETECTOR
-
- -
- -
- 1
1
-
DETECTOR
LEAD—IN
06 DETECTOR
-
- -
2 2
2 -
-
-
08 DETEC OR
-
1 1
1 1
1 -
-
-
CABLE
2
2
2
3
3 1
1
1
TOTAL
1
2 2 14
1 4
4
IU 30'
15'
#10
LUMINAIRE
2
2
2
2
2
- -
2
2
c
TYPE
HT.
SIG.
LU M.
H.P.S.V.
TYPE
E5
VEHICLE
PED.
°D
A
<
,l]-
19-3-80
30'
30'
15'
250 W
OPTICOM
1
2
2
2
3
3 1
1
1
CONDUIT SIZE 3" 3" 3" 4" 4" 4" 3" 3" 3"
- ALL CONDUCTORS AND CONDUIT ARE NEW.
ELECTRIC SERVICE FEED POINT
(NW QUAD UP 598267H)
TELEPHONE SERVICE FEED POINT
(TELEPHONE PEDESTAL)
D Ilk
H03
2" W
R28(S)(LT)
1
I
�I
0
w
32' 12'
R18-2 Tr
II-, - ' II
Il m
I I IIII �I I i
IIIA zl
8 VEH II I I o
HEADS (2) RC LOOPS (2) AB O
Li
4 II I I IA I I I�' �)
W
0Z
W
Q
POLE SCHEDULE ■
L
z
MASTARMS
LUMINAIRE
PED PUSH BT.
SIGNAL MOUNTING
S.N.S.
0
REMARKS
c
TYPE
HT.
SIG.
LU M.
H.P.S.V.
TYPE
E5
VEHICLE
PED.
°D
A
<
,l]-
19-3-80
30'
30'
15'
250 W
B
6 E , 8 S
MAS, SV-2—TAN
SP -2—T
Locust Avenue
N
IZ I^
5.0'
2
44
U
IU 30'
�I
0
w
32' 12'
R18-2 Tr
II-, - ' II
Il m
I I IIII �I I i
IIIA zl
8 VEH II I I o
HEADS (2) RC LOOPS (2) AB O
Li
4 II I I IA I I I�' �)
W
0Z
W
Q
POLE SCHEDULE ■
L
STANDARD
MASTARMS
LUMINAIRE
PED PUSH BT.
SIGNAL MOUNTING
S.N.S.
PLACEMENT
REMARKS
c
TYPE
HT.
SIG.
LU M.
H.P.S.V.
TYPE
PHASE QUAD
VEHICLE
PED.
MESSAGE
A
B
,l]-
19-3-80
30'
30'
15'
250 W
B
6 E , 8 S
MAS, SV-2—TAN
SP -2—T
Locust Avenue
N
10.7'
5.0'
2
17D-1-70*
30'
18
15'
250 W
B
N
4 N , 6(E)
MAS, SV-2—TAN
SP -2—T
—
15.8'
3.5'
3
19-2-80*
30'
30'
15'
250 W
B
2(W), 4 N
MAS, SV-2—TAN
SP -2—T
Locust Avenue
N
**
11.6'
3.0'
4
1 A
N
10'
—
—
—
B[R]
2(W)
TV -1—T
N
SP-1—CSN
—
As Dimensioned
5
17-2-70
N
30'20'
N
15'
N
250 W
R
B
R
8(s)
MAS
R,
SV-1—T[N]
SP-1—CS[N]_.Merrill
Avenue
[N]**
As Dimensioned
■ - ALL EQUIPMENT IS EXISTING UNLESS OTHERWISE NOTED:
[N] - NEW
[R] - RELOCATED
* EXISTING POLE STANDARD TYPE WAS ESTABLISHED FROM FIELD MEASUREMENTS
OF POLE AND MASTARM EQUIPMENT.
** STREET NAME SIGN TO BE FURNISHED BY THE COUNTY OF SAN BERNARDINO.
BARRIER
PHASE
DIAGRAM
NOT
USED
i
NOT
USED
PHASE 1
PHASE 2
PHASE 3
PHASE 4
NOT
USED
+
NOT
USED
PHASE 5
PHASE 6
PHASE 7
PHASE 8
4 2
3 C13 I I �I I I I I I I R2(40) [RC]POLE & BASE COMPLETE EXCEPT RS MAST
I I �I � I I' I
I I I ARMS & RL LUMINAIRE, 12" VEH HEAD, MAS MTG
1 I ( I I I I 3 2 PED HEADS, & PPB'S TO LOC O.
—
1 4.5'
RC PB
6 / I 0 12 4.0
M — — — — — 5 o RC SIGN 1 & POST POLE
8P a- O O
6E
- - - —E 1 2" C., 2 DLC i I f — EOH EOH
N
3"G
_ -- - EOH — — FH - L 285' TO BACK OF XWALK
_ �0 02
I �_ _ _ T --
�2
T
—2 C., 4#10(LUM) I I EX. II
2 C., 2#6(SIG) 0 -tiPOLE
I I I ��
INSTALL CONDUIT I I I CONDUIT A -I- �' I L 2" C., 1 DLC
�� �N
UNDER EW. SD I I W T w 2" w 5T
�8 — — — — — — — — — — — — — — — — —
3"G _ (3..G /3..G
8 10, I y I� 8F1 ir) o
TYP I �' I � 1-E-8 N N 2-E-8
a, I F —1I 2' TYP �
04
1-W 4I ^ 06 06 — v I il 1
14 1/2' W
2" C. 1 DLC —f 6T
m�
1 3/4" W
EX. CHAIN LINK FENCE
EX
R/w
-- -
4 LOOPS AB
1230' ro BACK OF xwnLK
MERRILL
GENERAL NOTES:
1. TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA STANDARD
SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 1992)
2. LOCATION OF ALL UNDERGROUND UTILITITES ARE APPROXIMATE. THE CONTRACTOR SHALL
DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE.
HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS. PHONE UNDERGROUND SERVICE
ALERT AT 800/227-2600, 48 HOURS BEFORE DIGGING.
3. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID METAL EXCEPT AS SHOWN.
ALL VEHICLE HEADS SHALL BE METALLIC WITH 12" GLASS LENSES, AND METALLIC LOUVERED
BACKPLATES.
4. COORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING WITH THE SOUTHERN CALIFORNIA
EDISON COMPANY WELL IN ADVANCE OF NEED.
5. EXISTING LIGHTING TO BE REMOVED SHALL REMAIN IN OPERATION UNTIL NEW LIGHTING
IS OPERATIONAL.
6. OBTAIN APPROVAL FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT.
7. RELOCATE OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALK AFFECTED BY
CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER.
8. CONTROLLER SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY
SPRINKLER SYSTEMS IF NECESSARY.
9. ALL LOOPS NOT SHOWN TO BE ABANDONED SHALL BE RECONNECTED AS DIRECTED BY
THE ENGINEER IN THE FIELD.
8" VEH HEADS (2)
& 04P PPB
MW
I N 6 W 6 W
08 ITI ( I I O
I
- ,� -- AB 6 f, I I� I
AB CONDUIT EX. CURB do GUTTER
2 4P— _ LOH LOH
P RC PBLO
EXR W
12' r
3 cc
RC 8., VEH HEADS (2)
II i
AB CONDUIT "ENUE
= 25' 11'8;
0
Ld
I I I I II
I
R2(40)I I I I I)
I w
RS EX. CONTROLLER &
II I I BASE COMPLETE
CONSTRUCTION NOTES
W n SIJ
II w
AB CONDUIT cc ❑1 INSTALL CITY -FURNISHED TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA
AND EDISON REQUIREMENTS.
� 44' 30'
20 FURNISH AND INSTALL PULLBOX, 2" C., AND PULLROPE FOR COMMUNICATION CONDUCTORS PER
Curb/Berm flow line
or edge of shoulder
30'
Q z
Z
ac
ii j o
30' I
RS EX. TYPE to SERVICE
y� (SCE METER N0. 3-115990)
PACIFIC BELL REQUIREMENTS.
F3] INSTALL TYPE 90 CONTROLLER ASSEMBLY (CONTROLLER EQUIPMENT PACKAGE) COMPLETE WITH
TYPE "P" CABINET AND AUXILLIARY EQUIPMENT NECESSARY TO PROVIDE THE INTENDED
OPERATION.
74 INSTALL 3" SCH. 80 PVC CONDUIT, PULLROPE, AND RISER PER SOUTHERN CALIFORNIA EDISON
REQUIREMENTS.
:4
U
Li
Z
Q
J
QLZ
O
U
D
O
J
Z
c�
U
Q
W
W
Q
J
W
W
W
Q
U
O
L o cMerr. d w