HomeMy WebLinkAbout2811-1TRAFFIC SIGNAL GENERAL NOTES:
1. TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA
STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 1992)
2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR
SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS
ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS.
PHONE UNDERGROUND SERVICE ALERT AT (800)227-2600, TWO (2) WORKING DAYS
BEFORE DIGGING.
3. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID METAL EXCEPT
WHERE NOTED OTHERWISE. ALL VEHICLE HEADS SHALL BE PER SPECIAL PROVISIONS.
4. CONTRACTOR SHALL COORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING
WITH THE SOUTHERN CALIFORNIA EDISON COMPANY WELL IN ADVANCE OF NEED.
5. EXISTING LIGHTING SHALL REMAIN IN OPERATION UNTIL NEW SIGNAL AND LIGHTING
IS OPERATIONAL PER SPECIFICATIONS.
6. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT
LOCATIONS PRIOR TO FINAL PLACEMENT.
7. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND -
SIDEWALK AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER.
8. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS.
MODIFY SPRINKLER SYSTEMS IF NECESSARY.
9. CONTRACTOR SHALL REFER TO THE CITY TRAFFIC ENGINEER IN THE EVENT OF A
CONFLICT OR POTENTIAL CONFLICT WITH THESE PLANS AND/OR SPECIFICATIONS FOR
THIS PROJECT.
10. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM CALTRANS,
SAN BERNARDINO COUNTY AND THE CITY OF FONTANA ENGINEERING DIVISION
PRIOR TO COMMENCEMENT OF WORK.
11 ALL TRAFFIC CONTROL, WORK ZONES AND LANE CLOSURES SHALL BE COMPLETELY
DELINEATED BY CHANNELIZATION DEVICES AND SHIELDED BY BARRIERS TO EXCLUDE
VEHICLE AND/OR PEDESTRIAN TRAFFIC. CONTRACTOR SHALL FOLLOW THE MANUAL
OF TRAFFIC CONTROL DEVICES FOR CONSTRUCTION AND MAINTENANCE WORK ZONES,
CALTRANS STANDARD SPECIFICATIONS AND STANDARD PLANS, LATEST EDITION. EXACT
LOCATION OF ALL TRAFFIC CONTROL TO BE DETERMINED BY THE ENGINEER AND
ADDITIONAL WARNING AND/OR CONSTRUCTION SIGNING MAY BE REQUIRED.
12 PULLBOXES TO BE INSTALLED BE AT 200' MAXIMUM SPACING UNLESS OTHERWISE
DIRECTED BY THE ENGINEER.
TOLL FREE
A PUBLIC SERVICE BY
r
COUNTY OF SAN BERNARDINO
"COUNTY JURISDICTION ONLY
zeal'
TRAFFIC DIVISION DATE:
14
SON TAN A AUTO
A�� C S GNAT
M
PA\S
PARCEL MAP 14518
N THE C _ -TY 0� SON TAN A
SHEET N0. 2/5 -
TRAFFIC SIGNAL DESIGN )
SAN BERNARDINO
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN. A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
REV. PLANS TO BRING THEM INTO CONFORMANCE WITH
REVISION DESCRIPTION DATE ENGR. CITY DATE STANDARDS IN EFFECT.
,---SHEET N0. 3/5
( TRAFFIC SIGNAL MODIFICATION )
®
SHEET N0. 4/5----,
( TRAFFIC SIGNAL MODIFICATION )
FREEWAY
N.T.S.
0'R0URKE E'NGINE'E'R1NG
415 N. VINEYARD AVE. SUITE 200
ONTARIO, CA 91764 (909) 937-0221
REGISTERED CIVIL ENGINES
7-y7--o�
PLAN APPROVAL DATE
UNDERGROUND UTILITIES & STRUCTURES
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR
STRUCTURES SHOWN IN THESE PLANS WERE OBTAINED BY A SEARCH OF
AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO
EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE
CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO
PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION
OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES.
"CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE
RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF
THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND
MUST BE APPROVED BY THE PREPARER OF THESE PLANS."
SERVICE ADDRESS:
O QRpF ESS/09
E O'ROG �2
G)
No. rn
r
Cz C055985 r+�
12/00
s
�9 �•Q
TF OF CAI -IFS¢
AUTOCAD FILENAME 1 -5. DWG
CITY OF FCALIFORNIA
TRAFFIC SIGNAL, LIGHTING AND INTERCONNECT P LAN
DRAWN BY: TITLE SHEET SCALE:
GM F0� NONE
DESIGNED BY: DATE:
CR FONTANA AUTO MALL 7/14/00
CHECKED BY: APP VED BMX; DRAWING NO.: 1
�l A DATE: '� "2 x'06
SO' R CI FIC ENGINEERS R.C.E. 26690 .2811 5