Loading...
HomeMy WebLinkAbout2817-2CD CD m 0) EXISTING CURB ONLY OVERLA r THICKNESS EXISTING CURB EXISTING CURB ONLY\ B B AND GUTTER ,tea 1 n n �c 0 >- A PLAN VIEW L� C ONILY STING CURB � ANDTGUTTEING R B SECTION A -A EXISTING A.C. PAVEMENT SURFACE \ I 12,* i� OVERLAY THICKNESS 6' I -3/8" LIP---- OVERLAY OVERLAY THICKNESS THICKNESS SECTION B -B SECTION C -C 6' SECONDARY STREET 12' on 3/8" LIP PRIMARY STREE TYP. COLD PLANE AREA AT EXISTING STREETS W/O GUTTERS *18' ON MAJOR INTERSECTIONS [of MIL I qlq�j OVERLAY THICKNESS TYP. COLD PLANE AREA AT EXISTING STREETS W/O GUTTERS CROSSWALK DETAIL ZB FACE rS FOR WHEEL CHAIR RAMPS VED BY THE ENGINEER 0 ION IS TO THE F THE LINE CONSTRUCTION NOTES: �1 ADJUST EXISTING MANHOLE TO GRADE PER CITY STD. 109. ADJUST EXISTING UTILITY VALVE TO GRADE. 33 PROTECT EXISTING INLET GRATE. CONSTRUCT H.C. RAMP PER APWA STD, 111-2. 5OREMOVE AND REPLACE X -GUTTER PER CITY STD. 104. REMOVE AND REPLACE EXISTING CURB AND GUTTER PER CITY STD. 101. O REMOVE AND REPLACE 4" SIDEWALK AND/OR PCC DRIVEWAY APPROACH PER CITY STANDARDS. O CONSTRUCT 8" CURB AND GUTTER PER CITY STD. 101. 99 CONSTRUCT 4" P.C.C. SIDEWALK. 10 ADJUSTMENT BY OTHERS, CONTRACTOR WILL MARK LOCATION. 011REMOVE EXISTING SUBGRADE AND PLACE 0.30' AC AND 0.17' AC OVERLAY. 12 6' X 6" P.C.C. RIBBON GUTTER. 13 EXTEND 3 - 36" RCP AND CONSTRUCT HEADWALL (SEE DETAIL SHEET 2) 148 REMOVE EXISTING SUBGRADE AND PLACE 0.30' AC AND 0.15' AC OVERLAY 15 THE CITY RESERVES THE RIGHT TO DELETE CERTAIN WIDENING CURB & GUTTER AND SIDEWALK IMPROVEMENTS DUE TO UNSUCCESSFUL RIGHT-OF-WAY ACQUISITION. 16 REMOVE EXISTING DRAINAGE STRUCTURE AND CONSTRUCT TYPE G-1 DRAINAGE INLET PER CALTRANS STD. D73. LEGEND: 17227 STREET ADDRESS HEADER CUT PER DETAIL ON SHEET 2 Underground Service Alert SECTION 4216/4217 OF THE GOVERNMENT ORE Y CODE REQUIRES A DIG ALERT IDENTIFICATION NUMBER BE ISSUED BEFORE A PERMIT TO EXCAVATE WILL BE VALID FOR YOUR DIG ALERT I.D. NUMBER CALL UNDERGROUND SERVICE ALERT TOLL FREE 1-800-227-2600 TWO WORKING DAYS BEFORE YOU DIG GLIENI: UIT OF FONTANA 124-09 MODIFY AND11 1 RELOCATE ' EXISTING RAIL I II END EXISTING WARPED WING WALL EMBEDMENT DEPTH TO MATCH EXISTING Z�lll 11 - ,NEW 6' S/W REMOVAL LIMIT FOR • EXISTING LINING ( II_ _ REMOVAL=1 6 f5'11" AND WINGWALLS I I3»I RADIUS EXISTING h EXTEND CHANNEL I II I , I EXISTING RCP LINING I II I --, E - SECTION AmA �. SCALE: 1"=4' TOP OF EXISTING CHANNEL LINING R/W i.Q.a „ .:..:. SAW CUT EXISTING CHANNEL AND WING WALLS D 89* AND CONSTRUCT HEADWALL PER CALTRANS STD a EXTEND 3--36" RECONSTRUCT ! RCP (1350 D),,,,C,HANNEL LINING i 6 THICK / / 8 l S DGA KLj R/W i \\X\`\ • , . • 1 ' 136" RCP 1 136' RCPI 136" RCP I I I I I NOTES ALL STRUCTURAL CONCRETE WITHIN SBCFC DISTRICT RIGHT-OF-WAY SHALL BE 650-A-4000 IN ALL INVERTS AND 650-B-4000 FOR ALL WALLS. NEW CONCRETE SHALL BE JOINED TO EXISTING CONCRETE WITH #4 BARS x 18" CSD 12" C -C. BARS SHALL 6E EPDXY GROUTED INTO EXISTING CONCRETE 9" MIN. TEMPORARY RAILING TO BE INSTALLED WHILE UNDER CONSTRUCTION. Q FINISH 36" R.C.P. WITH 3" RADIUS AT FACE OF HEADWALL. R/W p 6" FACE OF CURB ------ REMOVE PARAPET AND WING WALLS TO SUBGRADE OF NEW SIDEWALK REMOVE AND RELOCATE HAND RAILING TO NEW HEADWALL MODIFY RAIL TO FIT NEW LOCATION HEADWALL DETAIL AT RAILROAD. (SEE SHEET 8) SCALE: 1•=4• y R TBM=BCR S E CORNER OWEN ST. '? 6 5 LF AND PALMETTO AVE. ''' ` N FD. L&T EL.=100.00 i • '�. JOIN EXISTING a ' �'' CURB AND GUTTER EXISTING -1• •.,. BLOCK WALL" •'� �Or, N/07 4•a:' a6 FIRE HYDRANT9� • a R/W ,� a ROLLED CURB ��' ' AND GUTTER • ' • '� ' of 11 A F JOIN EXIST 4 ° ' d ' s • ; ' • g 5 1.56% "'a• •. .ge 4 OWEN STREET 4• a in 16' 9' ' 8' 3.5' v M f- '4 a a aT. •. ' •i v. A. 2.31%Y •. JOIN EXIST-­'�' ' �• ' `C .a G v .. R/W a qlb a a • .� ROLLED CURB °b�� AND GUTTER a� 6" CURB a0" ' C.F.., 4 .A v cb ' ° e co R /W • Olt A 9:4■ H. G i OpJ N N0. C 21062 EXP. 9-30-01 J,�gTc� C IV OF CALF SUBMITTED BY: SCALE: 1"=l 0' 1 REMOVAL LIMIT FOR EXISTING LINING AND WINGWALLS R/W SEA (1) CONSTRUCT 8' WIDE X -GUTTER AS SHOWN 'E 3 PER CITY STD. DETAIL 104 (2) SAW CUT EXISTING AC AND MATCH X -GUTTER TO EXISTING GRADES ON PALMETTO. COLD PLANE OWEN STREET TO MEET LIP OF NEW X -GUTTER (3) REMOVE EXISTING SIDEWALK AND CONSTRUCT H.C. RAMP, CASE A TYPE 3. (4) GRADES SHOWN ARE EXISTING ASE A YPE 3 JOIN EXISTING CURB AND GUTTER DATE: ?z/. Z do DOUGLAS 'H. MAYS R.C.E. No. 21062 EXPIRES: 9-30-01 CITY OF FONTANA GENERAL NOTES FOR STREET IMPROVEMENT PLANS 1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION, PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF -METRIC EDITION, UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO T; HE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 13. CURVE DATA REFERS TO THE FACE OF CURB. 14. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE NOTED 15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 20. ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND VELOCITIES EXCEED 25 MILES PER HOUR 21. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 22. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 23. 23 A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE REWORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 25. THE FINAL LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE APPROVED AT THE TIME OF CONSTRUCTION AND SHALL CONFORM TO THE CITY OF FONTANA STANDARD DETAILS. 26. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 27. THE CONTRACTOR SHALL REPLACE THE "S" IN THE FACE OF THE CURB AT ANY SEWER LATERAL, IF CURB REMOVED AND REPLACED AT THAT LOCATION. 28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 31. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL OF THE CITY ENGINEER AS DETERMINED BY SOILS TESTS TAKEN AFTER COMPLETION OF ROUGH GRADING. 32. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR STRUCTURAL STREET SECTIONS SHALL BE RECOMMENDED BY A GEOTECHNICAL REPORT AND SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL UPON COMPLETION OF ROUGH GRADING. 33. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 34. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADE'S, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER 35. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALKS AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE CITY ENGINEER 36. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. CITY CF FONTANA, CALIFORNIA SHOULD CONSTRUCTION OF THE REQUIRED PAVEMENT REHABILITATION PROJECT IMPROVEMENTS NOT COMMENCE WITHIN TWO L.D. KING, INC. YEARS OF THE DATE OF APPROVAL SHOWN DRAWN BY: DETAIL SHEET SCALE l)lcinr; 2151 CONVENTION CENTER WAY HEREON AND CARRIED FORTH IN A DILIGENT MSM LSUITE 1008 MANNER, THE CITY ENGINEER MAY REQUIRE DESIGNED BY: DETAILS, CONSTRUCTION NOTES, DATE: ONTARIO, CA 91764 REVISIONS TO THE PLANS TO BRING THEM GENERAL NOTES, LEGEND 02/08/00 (909) 937-0200 INTO CONFORMANCE WITH CONDITIONS AND CHECKED BY: APPROVED BY: DATE: DRAWING NO.: 2 STANDARDS IN EFFECT. 1.�:`t-c" /h, 7-12-00 2817 18 FoeCITY ENGINEER R.C.E. No. 25126-" 11 08- R 1 REVISED HEADWALL & RAILING PER FCD. 7/11 /00 DEW M • 7-12-w REV. REVISION DESCRIPTION DATE ENGR. CITY DATE H. G i OpJ N N0. C 21062 EXP. 9-30-01 J,�gTc� C IV OF CALF SUBMITTED BY: SCALE: 1"=l 0' 1 REMOVAL LIMIT FOR EXISTING LINING AND WINGWALLS R/W SEA (1) CONSTRUCT 8' WIDE X -GUTTER AS SHOWN 'E 3 PER CITY STD. DETAIL 104 (2) SAW CUT EXISTING AC AND MATCH X -GUTTER TO EXISTING GRADES ON PALMETTO. COLD PLANE OWEN STREET TO MEET LIP OF NEW X -GUTTER (3) REMOVE EXISTING SIDEWALK AND CONSTRUCT H.C. RAMP, CASE A TYPE 3. (4) GRADES SHOWN ARE EXISTING ASE A YPE 3 JOIN EXISTING CURB AND GUTTER DATE: ?z/. Z do DOUGLAS 'H. MAYS R.C.E. No. 21062 EXPIRES: 9-30-01 CITY OF FONTANA GENERAL NOTES FOR STREET IMPROVEMENT PLANS 1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION, PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF -METRIC EDITION, UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO T; HE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 13. CURVE DATA REFERS TO THE FACE OF CURB. 14. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE NOTED 15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 20. ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND VELOCITIES EXCEED 25 MILES PER HOUR 21. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 22. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 23. 23 A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE REWORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 25. THE FINAL LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE APPROVED AT THE TIME OF CONSTRUCTION AND SHALL CONFORM TO THE CITY OF FONTANA STANDARD DETAILS. 26. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 27. THE CONTRACTOR SHALL REPLACE THE "S" IN THE FACE OF THE CURB AT ANY SEWER LATERAL, IF CURB REMOVED AND REPLACED AT THAT LOCATION. 28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 31. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL OF THE CITY ENGINEER AS DETERMINED BY SOILS TESTS TAKEN AFTER COMPLETION OF ROUGH GRADING. 32. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR STRUCTURAL STREET SECTIONS SHALL BE RECOMMENDED BY A GEOTECHNICAL REPORT AND SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL UPON COMPLETION OF ROUGH GRADING. 33. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 34. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADE'S, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER 35. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALKS AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE CITY ENGINEER 36. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. CITY CF FONTANA, CALIFORNIA SHOULD CONSTRUCTION OF THE REQUIRED PAVEMENT REHABILITATION PROJECT IMPROVEMENTS NOT COMMENCE WITHIN TWO L.D. KING, INC. YEARS OF THE DATE OF APPROVAL SHOWN DRAWN BY: DETAIL SHEET SCALE l)lcinr; 2151 CONVENTION CENTER WAY HEREON AND CARRIED FORTH IN A DILIGENT MSM LSUITE 1008 MANNER, THE CITY ENGINEER MAY REQUIRE DESIGNED BY: DETAILS, CONSTRUCTION NOTES, DATE: ONTARIO, CA 91764 REVISIONS TO THE PLANS TO BRING THEM GENERAL NOTES, LEGEND 02/08/00 (909) 937-0200 INTO CONFORMANCE WITH CONDITIONS AND CHECKED BY: APPROVED BY: DATE: DRAWING NO.: 2 STANDARDS IN EFFECT. 1.�:`t-c" /h, 7-12-00 2817 18 FoeCITY ENGINEER R.C.E. No. 25126-" 11 08- R