HomeMy WebLinkAbout2809-1GENERAL NOTES: 1 . ELEVATIONS ARE IN FEET ABOVE U.S.C. & G.C. MEAN SEA LEVEL DATUM OF 1929 2. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN SET, INSPECTED AND APPROVED. 3. ALL CONCRETE SHALL BE PORTLAND CEMENT CONCRETE WITH AN ULTIMATE 28 -DAY COMPRESSIVE STRENGTH OF 3250 P.S.I. UNLESS DIFFERENTLY SPECIFIED. 4. ALL EXPOSED EDGES SHALL BE FINISHED WITH A 3/4" CHAMFER. 5. ALL STEEL ADJACENT TO FACE OF CONCRETE SHALL HAVE A 2 1/2" CLEARANCE UNLESS OTHERWISE SPECIFIED. 6. REINFORCEMENT SHALL BE DEFORMED BARS OF INTERMEDIATE GRADE STEEL AS PER A.S.T.M. A-615 GRADE 60. 7. ALL BAR BENDS AND HOOKS SHALL CONFORM TO THE AMERICAN CONCRETE INSTITUTE "MANUAL OF STANDARD PRACTICE". 8. DIMENSIONS FROM FACE OF CONCRETE TO STEEL ARE TO CENTER LINE OF STEEL UNLESS OTHERWISE NOTED. 9. ALL BACKFILLS AND FILLS TO BE USED AS SUBGRADES SHALL BE COMPACTED TO A RELATIVE DENSITY OF 90% UNLESS OTHERWISE SPECIFIED. TOP 12" OF SUBGRADE TO BE 95%. ANY A.B. THICKNESS SHALL BE CONSIDERED AS INCLUDED IN THE 12" DIMENSION. 10. ALL STEEL THAT IS TO BE CONTINUOUS SHALL HAVE A MINIMUM LAP OF 30 BAR DIAMETERS OR 18" WHICHEVER IS GREATER. 11. PIPE SHALL BE EMBEDDED 5" INTO ALL STRUCTURES INCLUDING INLET AND HEADWALLS, UNLESS OTHERWISE SPECIFIED. 12. ALL BACKFILL AND FILL AROUND CLOSED CONDUIT IN STREET RIGHT-OF-WAY SHALL BE BROUGHT UP TO SUBGRADE OF THE ROAD. THE PUBLIC WORKS INSPECTOR AND THE SOILS ENGINEER SHALL INSPECT ALL BACKFILL AND FILL ABOVE AFOREMENTIONED LIMIT. APPLICATIONS FOR AN ENGINEER OR INSPECTOR IN CONNECTION WITH THE WORK SHALL BE MADE BY THE CONTRACTOR AT LEAST 1 WORKING DAY BEFORE HIS SERVICE IS REQUIRED. 13. ALL REINFORCED CONCRETE PIPE SHALL BE BEDDED IN ACCORDANCE WITH LOS ANGELES COUNTY FLOOD CONTROL DISTRICT STD. DWG. NO. 2-D177, CASE III. (SEE BELOW). 14. THIS STORM DRAIN WILL NOT BE ACCEPTED FOR MAINTENANCE UNTIL THE STREETS HAVE BEEN PAVED, MANHOLES BROUGHT TO GRADE, AND THE SYSTEM IS CLEANED TO THE SATISFACTION OF THE CITY OF FONTANA AND COUNTY OF SAN BERNARDINO ENGINEERING DIVISIONS. 15. THE CONTRACTOR ATTENTION IS DIRECTED TO SECTION 7-10.4.1 OF THE STD. SPECIFICATIONS FOR PUBLIC WORK CONSTRUCTION IN REGARD TO SAFETY ORDERS. 16. THE CONTRACTOR SHALL CONFORM TO THE "MINIMUM PUBLIC SAFETY REQUIREMENTS" AS SHOWN ON LOS ANGELES COUNTY ENGINEER STD. 5-2. 17. A PERMIT SHALL BE OBTAINED FROM THE CITY OF FONTANA AND COUNTY OF SAN BERNARDINO PRIOR TO COMMENCING ANY CONSTRUCTION WORK UNDER THIS CONTRACT. CONTACT THE COUNTY OF SAN BERNARDINO AND THE CITY BY TELEPHONE AT (909) 350-7610 TO OBTAIN INSPECTION PERMIT. CALTRANS PERMIT NO. 08 -99 -N -MC -1464 TO CITY HAS BEEN OBTAINED FOR CONNECTION TO CALTRANS CHANNEL. CONTRACTOR TO APPLY FOR DUAL PERMIT. 18. THE CONTRACTOR SHALL PROVIDE FOR CONTRIBUTARY DRAINAGE AT ALL TIMES UNTIL THIS STORM DRAIN SYSTEM IS OPERABLE. 19. THE CONTRACTOR SHALL NOTIFY THE CITY OF FONTANA AT (909) 350-7610 AT LEAST 24 HOURS BEFORE BEGINING CONSTRUCTION. 20. PRIOR TO START OF ANY CONSTRUCTION, THE CONTRACTOR SHALL OBTAIN A PU13LIC WORKS CONSTRUCTION PERMIT FROM THE CITY OF FONTANA ENGINEERING DIVISION AND THE COUNTY OF SAN BERNARDINO. 21. THE PRIVATE ENGINEER SIGNING THESE PLANS IS RESPONSIBLE FOR ASSURING THE ACCURACY AND ACCEPTABILITY OF THE WORK HEREON, IN THE EVENT OF DISCREPANCIES ARISING DURING CONSTRUCTION, THE PRIVATE ENGINEER SHALL BE RESPONSIBLE FOR DETERMINING AN ACCEPTABLE SOLUTION AND REVISING THE PLANS FOR APPROVAL BY THE CITY. 22. ALL STATE AND LOCAL TRENCH SAFETY RULES WILL BE RIGIDLY ENFORCED. 23. CONTRACTOR SHALL FURNISH A LETTER OF CERTIFICATION FROM PIPE MANUFACTURER AS TO TEST RESULTS OF PIPE INSTALLED. (MIN. D -LOAD SHALL BE 1350-D). 24. R.C.P. SHALL BE MANUFACTURED AND INSPECTED IN ACCORDANCE WITH SECTION 207-2.7, 2.8 & 2.9 OF THE STD. SPECS. FOR PUBLIC WORKS. 25. ALL RESURFACING, CURBS, GUTTERS, SIDEWALKS, DRIVEWAYS AND ALL OTHER EXISTING IMPROVEMENTS TO BE RECONSTRUCTED SHALL BE CONSTRUCTED AT THE SAME ELEVATION AND LOCATION AS THE EXISTING IMPROVEMENTS, UNLESS OTHERWISE SHOWN ON THE PLANS. 26. ALL PIPES SHALL BE CERTIFIED BY MANUFACTURER AND MARKED WITH D -LOAD, DATE AND TEE'S LOCATIONS, MARKED FOR PUBLIC WORKS INSPECTOR ACCEPTANCE. 27. ALL PIPE WITH VELOCITIES EXCEEDING 20 F.P.S. WILL HAVE 1/2" THICKENED INVERTS. (SPECIAL COVER PIPE). 28. PIPES TO BE PLUGGED W/BRICK AND MORTAR SEE DETAIL SHEET 2 29. THE CONSTRUCTION OF ALL PUBLIC IMPROVEMENTS SHALL CONFORM TO THESE PLANS AND TO THE REQUIREMENTS OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (GREEN BOOK) AND THE COUNTY OF SAN BERNARDINO. 30. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM FONTANA ENGINEERING DIVISION, COUNTY OF SAN BERNARDINO AND CALTRANS PRIOR TO START OF ANY WORK WITHIN THE RESPECTIVE JURISDICTIONAL LIMITS. 31. STATIONING REFERS TO THE CENTERLINES OF STORM DRAINS EXCEPT WHERE OTHERWISE NOTED. 32. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO ALL ADJOINING CURBS AND SIDEWALKS. 33. UNDERGROUND SERVICE ALERT SHALL BE NOTIFIED 2 WORKING DAYS PRIOR TO START OF WORK (1-800-227-2600) 34. ALL UNDERGROUND WORK SHALL BE COMPLETED PRIOR TO PAVING OF STREETS. 35. EXISTING UNDERGROUND UTILITIES ARE AS PER THE AVAILABLE RECORDS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE ACTUAL LOCATION AND ELEVATION IN THE FIELD. 36. THE WALLS AND FACES OF ALL EXCAVATIONS GRATER THAN FIVE (5) FEET IN DEPTH SHALL BE EFFECTIVELY GUARDED BY A SHORING SYSTEM, SLOPING OF THE GROUND OR OTHER EQUIVALENT MEANS. TRENCHES LESS THAN FIVE (5) FEET IN DEPTH SHALL ALSO BE GUARDED WHEN EXAMINATION INDICATES HAZARDOUS GROUND MOVEMENT MAY BE EXPECTED. 37. THE CONTRACTOR'S SHALL ALSO OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK AS DESCRIBED IN NOTE 18 ABOVE FROM CAL/OSHA. 38. ALL MANHOLES SHALL BE CONSTRUCTED 6" BELOW PAVEMENT GRADE AND BROUGHT TO FINISH GRADE BY THE PAVING CONTRACTOR AFTER PAVEMENT IS IN PLACE. 39. IMMEDIATELY FOLLOWING REMOVAL OF EXISTING PAVEMENT OR DIKE OR CURB AND/OR GUTTER THE CONTRACTOR SHALL DILIGENTLY PURSUE THAT PORTION OF WORK TO COMPLETION. 40. ALL C.M.P. INSTALLATIONS AND CONNECTIONS SHALL BE MADE PER MANUFACTURER'S SUGGESTED METHOD UNLESS OTHERWISE SPECIFIED ON THE PLANS. 41. IF DURING CONSTRUCTION, GROUND WATER IS ENCOUNTERED, A SYSTEM APPROVED BY THE CITY ENGINEER SHALL BE INSTALLED TO DEWATER SAID AREA AT THE DIRECTION OF THE SOILS ENGINEER. 42. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY'S INSPECTOR. 43. ALL EXPOSED METAL SURFACES SHALL BE GALVANIZED IN ACCORDANCE WITH THE CITY STANDARD SPECIFICATIONS. 44. AS -BUILT PLANS SHALL BE PROVIDED TO THE CITY BY THE CONTRACTOR. 45. ALL POTHOLING SHALL BE PREAPPROVED IN WRITING BY THE CITY ENGINEER PRIOR TO COMMENCEMENT OF ANY WORK. 46. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AN EFFECTIVE MEANS OF DUST CONTROL WHICH SHALL INCLUDE PROVISIONS FOR ADEQUATE WATERING DURING THE PROCESS AND PROVISIONS FOR CONTINUANCE OF DUST CONTROL UNTIL SUCH TIME THAT THE GRADED SURFACE PRESENTS EFFICIENT PROTECTIVE COVER AGAINST WIND AND WATER EROSION THAT SPECIAL DUST CONTROL MEASURES ARE NO LONGER NECESSARY. I= FONTANA AUTO MALL STORM DRAIN PLANS CATAWBA AVENUE IN THE CITY OF FONTANA 47. LOCATIONS OF FIELD DENSITY TEST SHALL BE DETERMINED BY THE SOILS ENGINEER OR APPROVED TESTING AGENY AND SHALL BE SUFFICIENT IN BOTH HORIZONTAL AND VERTICAL PLACEMENT TO PROVIDE REPRESENTATIVE TESTING OF ALL FILL PLACED. TESTING IN AREAS OF A CRITICAL NATURE OF SPECIAL EMPHASIS SHALL BE IN ADDITION TO THE NORMAL REPRESENTATIVE SAMPLINGS. 48. ALL TRAVELED WAYS MUST BE CLEANED DAILY OF DIRT, MUD AND DEBRIS DEPOSITED ON THEM AS A RESULT OF THE GRADING OPERATION. CLEANING IS TO BE DONE TO THE SATISFACTION OF THE CITY ENGINEER. 49. ALL CONSTRUCTION AREAS SHALL BE PROPERLY POSTED AND LIGHTED IN CONFORMANCE WITH THE STATE MANUAL OF WARNING SIGN, LIGHTS AND DEVICES FOR USE IN THE PERFORMANCE OF WORK UPON HIGHWAYS, IN ORDER TO ELIMINATE ANY HAZARDS. 50. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS OR BENCHMARKS NOTED IN THE SPECIFICATIONS OR ON THE PLANS OR FOUND DURING CONSTRUCTION WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. MONUMENT REPLACEMENT SHALL BE DONE BY A REGISTERED CIVIL ENGINEER WITH RCE NUMBER 33965 OR LOWER OR A LICENSED LAND SURVEYOR ONLY. THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER ONE (1) WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED. NOTICE TO CONTRACTORS 1. CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD HARMLESS AGENCY AND THE CITY, THEIR ENGINEERS ( HEREINAFTER ASL CONSULTING ENGINEERS), THEIR OFFICERS, OFFICIALS, AGENTS, EMPLOYEES, AND CONTRACTORS FROM AND AGAINST ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES INCLUDING ATTORNEY'S FEES, ARISING OUT OF OR RESULTING FROM PERFORMANCE OF WORK UNDER THIS CONTRACT AND WHICH ARE ATTRIBUTABLE TO BODILY INJURY, SICKNESS, DISEASE OR DEATH, OR TO INJURY TO DESTRUCTION OF PROPERTY, INCLUDING THE LOSS OF USE RESULTING THEREFROM, CAUSED -1N WHOLE OR IN PART BY ANY ACT OR OMISSION OF THE CONTRACTOR OR ANYONE DIRECTLY OR INDIRECTLY EMPLOYED OR ENGAGED BY IT OR FOR WHOSE ACTS IT MAY BE LIABLE. 2. WITHOUT LIMITING THE GENERALITY OF FOREGOING NOTE NUMBER ONE, CONTRACTOR SPECIFICALLY AGREES TO INDEMNIFY AND HOLD HARMLESS AGENCY AND THE CITY, THEIR ENGINEERS (HEREINAFTER ASL CONSULTING ENGINEERS), THEIR OFFICERS, OFFICIALS, AGENTS, EMPLOYEES, AND CONTRACTORS FROM AND AGAINST ALL CLAIMS, DAMAGES, LOSSES, PENALTIES, FINES AND EXPENSES(INCLUDING ATTORNEY'S FEES AND LITIGATION COSTS) ARISING OUT OF OR IN ANY WAY RESULTING FROM CONTRACTOR'S FAILURE TO PERFORM THE WORK REQUIRED BY THIS CONTRACT AND APPLICABLE PROVISIONS OF FEDERAL AND STATE LAW. SUCH INDEMNIFICATION SHALL EXTEND TO ALL CLAIMS, DEMANDS, ACTIONS, OR LIABILITY FOR INJURIES, DEATH OR DAMAGES OCCURING AFTER COMPLETION OF THE PROJECT, AS WELL AS DURING THE WORK'S PROGRESS. CONTRACTOR FURTHER AGREES THAT IT SHALL ACCOMPLISH THE ABOVE AT ITS OWN COST, EXPENSE AND RISK EXCLUSIVE OF AND REGARDLESS OF ANY APPLICABLE INSURANCE POLICY OR POSITION TAKEN BY ANY INSURANCE COMPANY REGARDING COVERAGE. 3. THE LOCATION OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN AN APPROXIMATE WAY ONLY. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK. HE AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED BY HIS FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. 4. AB 73 REQUIRES EVERY PERSON PLANNING TO CONDUCT EXCAVATION TO NOTIFY A REGIONAL NOTIFICATION CENTER AT LEAST TWO DAYS PRIOR TO COMMENCING WORK. A VERIFICATION NUMBER WILL BE GIVEN UPON SUCH NOTIFICATION WITHOUT WHICH ANY PERMIT OR DIRECTIVE GIVING PERMISSION TO EXCAVATE SHALL BE INVALID. VERIFICATION NUMBERS EXPIRE WITHIN 14 DAYS. FOR BEST COMMUNICATION, PERSONS PERFORMING EXCAVATION SHOULD MEET THE UTILITY COMPANIES AT THE JOB SITE. FOR MORE INFORMATION, YOU CAN CONTACT THE LOCAL REGIONAL INFORMATION CENTER. UNDERGROUND SERVICE ALERT 3030 SATURN STREET, SUITE 200 BREA, CA. 92621 (800) 270-2600 5. THE EXISTENCE AND APPROXIMATE LOCATION OF UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS WERE DETERMINED BY A SEARCH OF THE AVAILABLE PUBLIC RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UNDERGROUND UTILITIES OR STRUCTURES EXCEPT AS SHOWN ON THE MAP. 6. THE CONTRACTOR IS REQUIRED TO TAKE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES OR STRUCTURES SHOWN AND ANY OTHER UTILITIES OR STRUCTURES AT THE SITE. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTILITIES OR STRUCTURES CONCERNED BEFORE STARTING WORK. BASIS OF BEARINGS BASIS OF BEARINGS: THE CENTERLINE OF IMPROVEMENTS FOR VALLEY BOULEVARD PER R.S. 70/39 BEING N 89'23'4799E SCHEDULE OF DRAWINGS SHEET DESCRIPTION 1 . . . . . . . . TITLE SHEET 29 39 4 . . . . DETAIL SHEETS 51 6 . . . . . . . CATAWBA AVENUE 7 . . . . . . . . LATERAL PROFILES 8 . . . . . . . . CATCH BASIN DETAILS UTLITY NOTIFICATIONS SEWER CITY OF FONTANA 8353 SIERRA AVENUE FONTANA, CA 92335 (909) 350-7610 POWER SOUTHERN CALIFORNIA EDISON 7951 REDWOOD AVENUE FONTANA, CA 92336 ATTN: JAIME AMEZCUA (909) 357-6581 GA& SOUTHERN CALIFORNIA GAS COMPANY TRANSMISSION DIVISION 2191 E. BIRCH STREET BREA, CA 92621 (714) 529-2889 SOUTHM CALFOFNA GAS COL P.O. BOX 3003 REDLANDS, CA 92373 MR. ALAN KESELOFF (909) 335-7781 WATER FONTANA WATER COMPANY (OWNED BY SGVWD) SAN GABRIEL VALLEY WATER COMPANY (SGVWD) 11142 GARVEY AVENUE EL MONTE, CA 91734 (626) 448-6183 EXT. 252 ATTN: LUIS MONTENEGRO CABLE COMCAST 1205 DUPONT AVENUE ONTARIO, CA 91761 (909) 390-4777 EXT. 3055 MR. JACK HAYES TELEPHONE: PACIFIC BELL 3939 E. CORONADO STREET ANAHEIM, CA 92807 (714) 666-5534 MR. JOEL B. DINNAUER,JR. 09349RAL TELE PHO E ENGINEERING DEPT. ONE GTE PLACE THOUSAND OAKS, CA (805) 372-6000 LNGXRGFIOLM ALERT 1-804.422-4133 CITY OF FONTANA FUTURE EXTENTION FOR THE CITY OF FONTANA'S MASTER PLAN FOR STORM DRAIN NOTE: 1. SEE SHEET 4 FOR TRENCH SECTION DETAIL 2. ALL LATERALS ARE CALCULATED TO THE CENTER OF CATCH BASIN UNLESS OTHERWISE NOTED. CONTRACTOR TO CONSTRUCT CATCH BASIN FLOORS TO DRAIN TO LATERAL PIPES. 3. SEE SHEET 3 FOR NOTES RELATED TO WORK WITHIN CALTRANS R/W 4. SEE SHEET 2 FOR CONSTRUCTION NOTES. AND QUANTITY ESTIMATES A RECORD DRAWING FREEWAY 10 THIS PROJECT DISCLAIMER � AUTO wD W MALL W QSITE BOULEVARD m Q Q � I U FREEWAY 10 5 MILES TO 9 MILES TO RANCHO CUCAMONGA SAN BERNARDINO INTERSTATE 15 1 INTERSTATE 215 VICINITY MAP N.T.S. COUNTY OF SAN BERNARDINO COUNTY OF SAN BERNARDINO VALLEY B.VM CITY OF FONTANA 00 EXISTING N.� CALTRANS CHANNEL INDEX MAP N.T.S. DINO COUNTY Of N BERNARDINO TING FACILITY CALTRANS R/W These documents have been prepared for a specific project and shall neither be altered nor reused for any other purpose. Also, these documents do not represent as -built conditions. If these documents are altered intentionally or unintentionally, or reused without the design engineer's written approval, it will be at the sole risk and responsibility of the user. The act of altering or reusing is construed as indemnifying and holding the design engineering firm and its employees harmless from all claims, damages, and expenses, including attorney fees, arising out of such act. CALTRANS PERMIT NO. 08 -99 -N -MC -1464 (SEE SHEETS 3 & 5 LSB] N:\2050\006\CAD\SDTLOl.DWG PLOT SCALE 1"=1