Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2889-3
CITY OF FONTANA IRRIGATION CONTROLLER STANDARD FOR COMMUNITY FACILITIES DISTRICTS (CFD'S) 1. Toro Network 8000 Model # 132-86-08, 32 station field satellite controller. 2. Mount in Strong Box Model No. SB-24SS/120V. (Stainless Steel) 3. Provide Rainmaster 32 PC 'Pigtail' for remote controll operation. 4. Provide Cambell Scientific Inc,TE525 tipping bucket (Heavy Duty Model) 5. Provide Sensor Input Board (SIB) Model #995-63 to interface with flow meter and rain shut off device. 6. Provide Radio Link Kit #89-7611 to communicate with central command. All radio equipment shall be compatible with VHF. 7. Provide ground rod and surge protection for each satellite controller. Contact: Curtis Newman California Turf (619) 520-6181 (619) 793-3999 (Pager) (800) 774-8873 (Main Office) Park and Landscape Development Section, Engineering Division Community Development Department,, City of Fontana (1/26/98) EXACT LOCATION OF CONTROLLER SHALL BE AGREED UPON BY EDISON, CITY LANDSCAPE INSPECTOR AND ❑ CONTRACTOR PRIOR TO ANY TRENCHING OR WIRE PLACEMENT GENERAL Nona: 36"PROVIDE 100A I1QIM AM SMA/V MAIN CS W VGXrATW 12" ON DRAWINGS PROVIDE PANELBOAILD WHERE INDICATED ON DRAWINGS. 1 : ;•:7 PROVIDE IRRIGATION CONTROLLER CABINET WHERE INDICATED ON DRAWR*409. TERMINATE AT EXrSTTaK RANDRME. PER S.C.E. COMPANY REQ. 90 VERIFY EXACT LOCATION AND TERMINATION REQ. WITH S.C.E. CO. SWEEP CONDUIT FOIL PRIOR TO TRENCHM ELLS CONTROLLER WIRER CONDUIT AND CONDUCTOR SIZES ARE BASED ON NONMETALLEC CONDUIT FRONT VIEW AND COPPER CONDUCTORS WITH TYPE "THHNM-IWN" INSULATION. NTS 10" 16" IRMATKIN CONTROL BOARD I H I I VMETERFACES UEET METER I I I I STRONG BOX I MODEL NO. SB- 24M20V rJ I I I 136" 12" I i � 0 SWEET CONDUIT FOR ELLS CONTROLLER WIRES END VIEW AUTOMATIC CONTROLLER FINISHED GRADE 6" MIN FROM HARDSCAPES 6"MIN SLEEVING II Lj%J %JI�I1%a `I I L/1� SERVICING ASSEMBLY PRESSURE REGULATOR IF RE UIRED. SET AS SHOWN ON�TTE DRAWINN(i MA OWS ♦� n r.� 11nuu1�.1111111111i.■=miITE 1111 ' � IJ • r 1 i� PRESMME IZER SUP ('TORUST B OC�'K) � FRONT (INTAKE) 3/4" GRAVEL 6" �� •� .. ♦:•• ♦' Vit. � � . 1 12" 1 PLAN 112" REDUCE PRESSURE BACKFLOW PREVENTER BRASS NIPPLE (4 PLACES) BRASS ELBOW 0-1 BRASS UNION BRASS PIPE 004 BRASS BALL VALVE LOCK BOX #•4 REBAR 18". PRESSURE— SUPPLY LINE (Di9CHARGE) FOOTING/FOUNDATION BACKFLOW ENCLOSURE (SEE NOTE BELOW) BRASS ELBOW BRASS UNION BRASS BALL VALVE #4 REBAR NOTE: BACKFLOW ENCLOSURE,LE MEUR OR EQUAL 24"X60"X36" HIGH END HINGED AT ONE END SECURE TO END 6"X8" FOOTING W/4" J BOLTS (EQUIPMENT TO BE CENTERED INSIDE HOUSING) GENERAL NOTES 1. CONTRACTOR SHALL FORM ENCLOSURE AND REQUEST INSPECTION PRIOR TO POURING FOOTING/FOUNDATION 2. CONTRACTOR SHALL USE 520—C-2500 CONCRETE. N.T.S. 161 BACKFLOW PREVENTER 30—INCH LINEAR LENGTH OF WIRE, COILED WATER PROOF CONNECTION (1 OF 2) ID TAG VALVE BOX WITH COVER: 12 X 18 FINISH GRADE/TOP OF MULCH REMOTE CONTROL VALVE: PVC SCH 80 NIPPLE (CLOSE) PVC SCH 40 ELL PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) BRICK (1 OF 4) SCH 80 NIPPLE (2—INCH LENGTH, HIDDEN) AND SCH 40 ELL PVC MAINLINE PIPE PVC SCH 40 TEE OR ELL PVC SCH 40 MALE ADAPTER PVC LATERAL PIPE 3.0—INCH MINIMUM DEPTH OF 3/4—INCH WASHED GRAVEL N.T.S. 19 I REMOTE CONTROL VALVE VON PRESSURE LATERAL LINE LATERAL LINE PRESSURE SUPPLY LINE CONTROLL WIRES LEAN BACKFILL FINE GRANULAR MATERIAL WELL BE PLACED ON ALL LINES, NO LARGER THAN 1/2" INCH IN SIZE. THIS WILL BE PERMITTED IN THE INITIAL BACKFILL MEASURED 6" FROM THE TOP OF PIPE. THE REMAINDER OF TRENCH CAN BE FILL WITH ROCK SCREENED 2" MINUS. ALL BACK FILL IS TO BE SATURATED AND COMPACTED TO 90'X. INSTALL ALL PVC PIPE WITH LABEL UP. SNAKE ALL PIPE IN TRENCH. BUNDLE AND TAPE ALL CONTROL WIRES AT 10' O.C. TO PRESSURE SUPPLY LINE AND PROVIDE A SERVICE LOOP AT ALL 90 DEGREE CHANGES IN DIRECTION. PRESSURE MAIN 2" AND LARGER SHALL BE P.V.C. CLASS 315 SMALLER THAN 2" SHALL BE P.V.C. SCHEDULE 40. CONTRACTOR SHALL PROVIDE SLEEVES OR COND'Utt LINES WHEN MAINLINE INSTALLATION IS UNDER ASPHALT OR CONCRETE. CONTRACTOR SHALL PROVIDE 24" INCHES OF COVER OVER PIPE SERVING A DRINKING FOUNTAIN OR PRESSURE hLkRdLIISM 3" AND LARGER. TRENCHING ANT MATERIAL EQUIPMENT SYMBOL MANUFACTURE MODEL DESCRIPTION DETAIL 8-Q BY OTHERS 0.24 WATER METER: 1-1/2" WITH SERVICE 900 8-T FEBCO 825Y BACKFLOW PREVENTER: 1 1/4" 3 1350 NIBCO T-113 GATE VALVE: LINE SIZE 4 — — — — 1800 12-Q MAINLINE PVC. SCH. 40 UP TO 1 1/2", CLASS 315 2" & UP 6 CY 1 900 LATERAL LINE PVC. CLASS 200 1/2" THRU 1 1/2" 6 _ - - - - - — 4 IRRIGATION SLEEVE PVC. SCH. 40 2 1/2 X DIA. OF PIPE 6 12' SUPERIOR 950—DW REMOTE CONTROL VALVE: 1-1 /4" '] 15-Q RAIN—BIRD 33—DRC QUICK COUPLER: LINE SIZE 5 © TORO N.W. 8000 132-8608 AUTOMATIC IRRIGATION CONTROLLER: 32 STATION 9 SUPERIOR 950 REMOTE CONTROL MASTER VALVE: 2" 7 SPRINKLER HEADS SYMBOL MANUFACTURE MODEL DESCRIPTION C� TORO 570-Z 12" SHRUB POP-UP AND D N.T.S. 3 ❑ FINISH GRADE VALVE BOX (LAWN) 7TADE COVER) WATER SERVICE LINE (if awl) 2X4 REDWOOD BLOCK CONTINUOUS AROUND N.T.S. 17 I GATE VALVE DISH GRADE/TOP OF MULCH )P—UP SPRAY SPRINKLER: 'C SCH 80 NIPPLE (LENGTH AS REQUIRED) 'C SCH 40 ELL 'C SCH 40 STREET ELL 'C SCH 80 NIPPLE (LENGTH AS REQUIRED) 'C SCH 40 STREET ELL IC SCH 40 TEE OR ELL . X LATERAL PIPE N.T. S. 1 10 1 POP-UP SPRAY SPRINKLER LINE SITE IIIRA.W GATE VALVE PVC MALE ADAPTOR r r r r PVC IRRIGATION MAIN I CUBIC FOOT GRAVEL FILL I ♦V N.T.S. 141 IRRIGATION LEGEND FINISH GRADE/TOP OF MULCH QUICK—COUPLING VALVE: RAIN BIRD MODEL 33DRC VALVE BOX WITH COVER: 6—INCH SIZE BRASS NIPPLE (LENGTH AS REQUIRED) 3—INCH MINIMUM DEPTH OF 3/4—INCH WASHED GRAVEL BRASS STREET ELL BRICK (1 OF 2) BRASS NIPPLE (LENGTH AS REQUIRED) BRASS STREET ELL PVC SCH 40 TEE OR ELL PVC MAINLINE PIPE BRASS ELL 2" x 2" REDWOOD STAKE W/ STAINLESS STEEL GEAR CLAMPS OR EQUIVALENT NOTE: SUPPORT SYSTEM 1. FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL TO NOMINAL QUICK COUPLING VALVE INLET SIZE. N.T.S. 18 1 QUICK -COUPLING VALVE NOZZLE RADIUS G.P.M. P.S.I. PATTERN 8-Q 8' 0.24 30 900 8-T 8' 0.30 1350 8-H 8' 0.50 1800 12-Q 12' 0.50 CY 1 900 12-T 12' 0.72 4 1350 12-H 12' 1.09 g 1800 15-Q 15' 0.85 l� 90° 15-T 15' 1.10 1 1350 15-H 15' 1.65 1 1800 4 -SST 4X30 0.90 SIDE 4 -EST 4X15 0.45 *O END N.T.S. I I SPRINKLER HEADS SHALL BE AS INDICATED ON THE DRAWINGS. SIX INCH (611) POP-UP TYPE SPRAY HEADS SHALL BE INSTALLED IN ALL LAWN AREAS. TWELVE INCH (12") POP-UP TYPE SPARY HEADS SHALL BE INSTALLED IN ALL GROUND COVER/SHRUB AREAS. MAINLINE AND LATERAL LINES TO BE SLEEVED UNDER ALL DRIVEWAYS AND WALKWAYS. CITY OF FONTANA CALIFORNIA Drawn By: L.K.D. Designed By: R.J.P. APPROVED: , Acn N.T.7s.5 IRRIGATION NOTES Scale: C.F.D. LANDSCAPE IMPROVEMENT PLANS 1 "= 20' for Date: CT No. 16046-1 7/17/2000 /TPA 11/1 Dwg. No. 3 CIN � ENGINEER RCE5752�°z88g 6 N.T.S.1 2 " .«" C A 0 jo,� CY �. 4� 4 Ua 0 g p"+ br l� UAW � ENO 000 DATE: 7/17/2004 JOB NO.: 99-36 DRAWN BY: L.K.D. REVISIONS: SHEET NUMBER: SHEET 3 oF: 6 A jo,� Ua g p"+ l� UAW � ENO 000 *O U rT, O 0 Z U U A U o w O P4 I� a DATE: 7/17/2004 JOB NO.: 99-36 DRAWN BY: L.K.D. REVISIONS: SHEET NUMBER: SHEET 3 oF: 6