HomeMy WebLinkAbout2883-15SCALE: N.T.S.
LEGEND:
1. HI -POP SHRUB HEAD BODY SET 114" ABOVE
FINISH GRADE.
2. FINISH GRADE.
3. SCH. 40 PVC 90 DEGREE STREET ELL.
4. MARLEX 90 DEGREE STREET ELL,
5. SCH. 80 PVC NIPPLE TYPICAL (2) PLACES.
6. MARLEX 90 DEGREE STREET ELL.
7. NON -PRESSURE LATERAL FITTING,
8. NON -PRESSURE LATERAL LINE.
NOTES:
1. LOCATE BEAD 2" TO 6" FROM WALKS, CURBS
HARDSCAPING, MOW STRIPS, AND EDGES OF
LAWN,
2. USE TEFLON TAPE ON ALL MALE THREADS.
3. INSTALL HEADS WITH INTERNAL CHECK VALVE
AND PRESSURE COMPENSATING FEATURE AS
PER THE IRRIGATION PLAN.
4, HEAD CONNECTION AT BOTTOM INLET ONLY.
SCALE: N.T. S. 3211
24" '
10
V V.
8
4 .#
to
5
9 13 11 12 FOOTING
LEGEND:
4" 1. RADIO ANTENNA - LOCATION PER CITY OR MANUFACTURERS
° RECOMMENDATIONS.
10
2. 24" FRONT ENTRY SATELLITE ASSEMBLY NEMA 313 STAINLESS
�- 11 STEEL RAINPROOF ENCLOSURE (UL LISTED).
3, MASTER VALVE RELAY OR PUMP START RELAY.
14
4. RADIO REMOTE ACCESS.
11
13 6, 1 112" PVC CONDUIT FOR 234 VAC, 1 -PHASE FROM METERED POWER
SUPPLY OR PER LOCAL ELECTRICAL CODES.
6. POWER SWITCH1GFI RECEPTACLE.
7. SATELLITE.
I L JUU 8"MIN. 8. 1 114" PVC CONDUIT FOR COMMUNICATION CABLE.
32' 9. PVC CONDUIT FOR CONTROL MIRES, SIZE AS REQUIRED.
12 10.1" PVC CONDUIT FOR FLOW SENSOR CABLE.
11. 11/4" PVC CONDUIT FOR COMMUNICATION CABLE TO OTHER
FRONT VIEW SATELLITES (IF APPLICABLE).
12.518" DIA. X V GROUND ROD WI#10 GROUND WIRE & CLAMP.
NOTE: SEE MATERIALS LIST DETAIL M, SHEET 1-- .
13. POURED CONCRETE I=QOTEAEG,
NOTES: 14. FILL VOIDS WITH CONCRETE.
NETWORK 8000 CONTROLLER, RADIO, RADIO LINK, POWER SUPPLY, & SENSOR INPUT BOARD INSTALLED ON BACKBOARD.
-CONTRACTOR TO THROW AWAY PEDESTAL TEMPLATE AFTER USE. DO NOT LEAVE UNDER CABINET.
IRRIGATION CONTROLLER FRONT VIEW
SCALE: N.T.S.
I. FUMF QVINI I1-{QL H€JV:$INU.
2. LOW SUCTION SWITCH
3. FLOW SWITCH
4. SKIES
5. BUTTERFLY VALVE (3)
6. PUMP HOUSING.
7. CHECK VALVE
8, FLANGED CONNECTION'T'
9. CONCRETE PAID.
10. ENCLSOURE
-IR
ZI *Wq I jo 01 viWo
SCALE. N.T.S.
L........1PWHITE
■ i r° Y �
r r
FLOW METER SIZE
TRACT! #15732
MINIMUM DISTANCE DOWNSTREAM OF
SNAP -TITS WATERPROOF
IRRIGATION CONTROLLH
RED
DESIGNED BY:
CONNECTOR OR EQUAL
BLACK
OAK
PIG TAIL EXPANSION
11/17/97
BLUE
LOOP (MIN. 24" LONG)
NOTE: WATERPROOF ALL WIRE CONNECTIONS.
WHITE
RK
PLASTIC VALVE BOK (CARSON OR(COMMON)
2883
�l
.�ILION.
►
lT f ENGINEER R.C.&: 6 EXP. DATE
WW
LOCKING LID. PLACE AT GRADE IN
TURF AREAS AND V ABOVE IN
x
I
10 Z
PLANT BEE),
Z
RED BLACK
W
LO
x
C)
0
W
x
•
x
x
PIG TAIL EXPANSION
LOOP (MIN. 24" LONG)
UF 1
nmmv
})VIRES
CONTROLLER
PEDESTAL
MASTERVALVECONTROL
.�
At •ir
SCALE: N.T.S.
LEGEND:
1. HI -POP SHRUB HEAD BODY SET 114" ABOVE
FINISH GRADE.
2. FINISH GRADE.
3. SCH. 40 PVC 90 DEGREE STREET ELL.
4. MARLEX 90 DEGREE STREET ELL,
5. SCH. 80 PVC NIPPLE TYPICAL (2) PLACES.
6. MARLEX 90 DEGREE STREET ELL.
7. NON -PRESSURE LATERAL FITTING,
8. NON -PRESSURE LATERAL LINE.
NOTES:
1. LOCATE BEAD 2" TO 6" FROM WALKS, CURBS
HARDSCAPING, MOW STRIPS, AND EDGES OF
LAWN,
2. USE TEFLON TAPE ON ALL MALE THREADS.
3. INSTALL HEADS WITH INTERNAL CHECK VALVE
AND PRESSURE COMPENSATING FEATURE AS
PER THE IRRIGATION PLAN.
4, HEAD CONNECTION AT BOTTOM INLET ONLY.
SCALE: N.T. S. 3211
24" '
10
V V.
8
4 .#
to
5
9 13 11 12 FOOTING
LEGEND:
4" 1. RADIO ANTENNA - LOCATION PER CITY OR MANUFACTURERS
° RECOMMENDATIONS.
10
2. 24" FRONT ENTRY SATELLITE ASSEMBLY NEMA 313 STAINLESS
�- 11 STEEL RAINPROOF ENCLOSURE (UL LISTED).
3, MASTER VALVE RELAY OR PUMP START RELAY.
14
4. RADIO REMOTE ACCESS.
11
13 6, 1 112" PVC CONDUIT FOR 234 VAC, 1 -PHASE FROM METERED POWER
SUPPLY OR PER LOCAL ELECTRICAL CODES.
6. POWER SWITCH1GFI RECEPTACLE.
7. SATELLITE.
I L JUU 8"MIN. 8. 1 114" PVC CONDUIT FOR COMMUNICATION CABLE.
32' 9. PVC CONDUIT FOR CONTROL MIRES, SIZE AS REQUIRED.
12 10.1" PVC CONDUIT FOR FLOW SENSOR CABLE.
11. 11/4" PVC CONDUIT FOR COMMUNICATION CABLE TO OTHER
FRONT VIEW SATELLITES (IF APPLICABLE).
12.518" DIA. X V GROUND ROD WI#10 GROUND WIRE & CLAMP.
NOTE: SEE MATERIALS LIST DETAIL M, SHEET 1-- .
13. POURED CONCRETE I=QOTEAEG,
NOTES: 14. FILL VOIDS WITH CONCRETE.
NETWORK 8000 CONTROLLER, RADIO, RADIO LINK, POWER SUPPLY, & SENSOR INPUT BOARD INSTALLED ON BACKBOARD.
-CONTRACTOR TO THROW AWAY PEDESTAL TEMPLATE AFTER USE. DO NOT LEAVE UNDER CABINET.
IRRIGATION CONTROLLER FRONT VIEW
SCALE: N.T.S.
I. FUMF QVINI I1-{QL H€JV:$INU.
2. LOW SUCTION SWITCH
3. FLOW SWITCH
4. SKIES
5. BUTTERFLY VALVE (3)
6. PUMP HOUSING.
7. CHECK VALVE
8, FLANGED CONNECTION'T'
9. CONCRETE PAID.
10. ENCLSOURE
-IR
ZI *Wq I jo 01 viWo
SCALE. N.T.S.
L........1PWHITE
DIAMETER SAME SIZE AS
BLUE
FLOW METER SIZE
TRACT! #15732
MINIMUM DISTANCE DOWNSTREAM OF
SNAP -TITS WATERPROOF
IRRIGATION CONTROLLH
RED
DESIGNED BY:
CONNECTOR OR EQUAL
BLACK
OAK
PIG TAIL EXPANSION
11/17/97
BLUE
LOOP (MIN. 24" LONG)
NOTE: WATERPROOF ALL WIRE CONNECTIONS.
WHITE
RK
PLASTIC VALVE BOK (CARSON OR(COMMON)
2883
�l
EQUAL) WITH PLASTIC INTEGRATED
lT f ENGINEER R.C.&: 6 EXP. DATE
WW
LOCKING LID. PLACE AT GRADE IN
TURF AREAS AND V ABOVE IN
x
I
10 Z
PLANT BEE),
Z
RED BLACK
W
LO
x
C)
0
W
x
•
x
x
PIG TAIL EXPANSION
LOOP (MIN. 24" LONG)
UF 1
1" PVC CONDUIT TO
})VIRES
CONTROLLER
PEDESTAL
MASTERVALVECONTROL
FLOWMETER
DIAMETER SAME
SIZE A3 FLOW
FLOW METE/m
RSVALVE
SCALE: N.T.S.
61, POP-UP SP
SCALE: N.T.S.
'8"
_EGEND:
1. RADIO ANTENNA - LOCATION PER CITY OR
MANUFACTURER'S RECOMMENDATIONS.
?. METERED ASSEMBLY ENCLOSURE NEMA 3R
STAINLESS STEEL RAINPROOF ENCLOSURE
(UL LISTED).
3.
CONTROLLER/SATELLITE PER FRONT VIEW
CONTROLLER DETAIL.
I. METER SOCKET WITEST BLOCKS.
x. CLUSTER CONTROL UNIT OR SECOND
CONTROLLER/SATELLITE IF APPLICABLE.
#, LOAD CENTER
t. POURED CONCRETE BASE.
L 11/2" PVC CONDUIT OR PER LOCAL
ELECTRICAL CODES FOR 120 VAC POWER
TO POWER SOURCE.
1.
CONDUIT(S) PER FRONT VIEW CONTROLLER
DETAIL.
10. 10" DIA. X 12'D. BOTTOMLESS GROUND WELL
WITH PARKWAY COVER, FILL WITH PEA
GRAVEL.
11.518" DIA. X 10' DRIVEN GROUND ROD PER
ARTICLE 250.81 OF 1990 NEC.
NOTE: SEE MATERIALS LIST DETAIL M, SHEET ,L-$,
SC M . S.
HYDRA BOOST System to be a factory prepiped,
and prewired, unit mounted on a galvanized steel skid base,
With control panel, stainless steel fitted inline multistage pump
with flanged connections, single phase motor, interconnecting
piping and Wiring, pressure reducing/check valve, With by pass line.
System to be complete with galvanized steel powdercoated en-
closure mounted and delivered on a concrete pad.
HYDROBOOST MODEL 1L338SP 120 P2-3.0, CDEFHKLMN
SYSTEM TO CONSIST OF THE FOLLOWING:
PUMP: Ebara EVMU8-3 multistage pump With stainless steel
impellers and casing. Pump designed for 33 gpm @ 135.
3 HP, 3550 IPM, 230 , 1 phase, Close coupled to
the pump.
I Q ATIO YA VE r Watts full lug butterfly valves with 10
>_ position handles with stainless steel sterns and aluminum bronze
discs. Also a one in the by-pass.
PIPING; 21
1
schedule 40 steel of easy to disassemble flanged
construction bolted together With SS nuts and bolts. All piping
to be hot dipped galvanized after fabrication for long lasting corrosion
resistance.
PRVXHECK VALVE: 2" Berrnad 720-20, flanged PRV,
combination check, fusion bond epoxy coated.
to be fabricated from 3"x3" angle steel drilled with
mounting hales and large enough to have system enclosure bolted
to it. Base to be hot dipped galvanized after fabrication.
ENCAM RE.- 10 gage galvanized steel enclosure with hinged
cover. Enclosure to be bolted to skidbase with a powercoated
finish (desert tan). Cover has provisions for padlocks. -
(:t 1NUM-P N_EL NEMA 313, UL labeled door in door
deadfront enclosure made of 304 SS, padlockable containing:
(1) HOA selector switch
�3) 24V start relays
1) NEMA sized circuit breaker
(1 No flow Off rely With timer With 0-60 sec. tuner
1) Control transformer
(1) Mag. starter
-OPT , nes:
Waits FS20 flow switch for no flow off.
Gauges: 2.5" stainless steel backed, liquid filled With brass ball
valves. Gauge on suction/discharge lines.
BOOSTER PUMP NOTES
SCALE- N.T.. A A
LEGEND:
1. ROUND PLASTIC VALVE BOX & COVER MARKED "IRRIGATION GATE".
USE CHRISTY FL8 BOX & FL80 LID OR EQUAL.
2. FINISH GRADE.
3. GATE VALVE - SEE IRRIGATION LEGEND FOR MODEL#.
4. 31,V WASHED aCRUSED AGGREGATE BASE,
5. SCH. 40 PVC MALE ADAPTORS.
NOTE:
PLACE AGGREGATE PRIOR TO INSTALLATION OF VALVE BOX.
GATE VALVE
SCALE: N.T.S.
FINISH GRADE:
AS REQUIRED
lvMI
r
0150"
20,01
i � f
CONTROL §MIRES f`MIN. 2" OF CLEAN EARTH
NOTES:
1. BELOW PAVED AREAS A MINIMUM OF 6" LAYER OF CLEEAN FILL SAND SHALL BE
INSTALLED ABOVE AND BELOW PIPING.
2, PROVIDE MINIMUM COVER OF 24" ON PRESSURE SUPPLY LINES 3" AND LARGER.
3. WHEN USING RECLAIMED WATER, MAINTAIN MINIMUM 1 WHORIZONTAL SEPARATION
BETWEEN POTABLE AND RECLAIMED PRESSURE LINES. WHERE LINES CROSS,
PROVIDE PVC SLEEVE FOR POTABLE LINE MINIMUM 5' EACH SIDE OF RECLAIMED
WATER LINE.
4. BUNDLE WIRES WITH TAPE E=VERY 10'.
i
SCALE: N.T.S.
AUTOMATIC CONTROLLER MATERIALS LIST:
- TORO NETWORK 8000 SERIES 32 MOREL 132-86-08
- SENSOR INPUT BOARD (SII) MODEL 995-63 (TO INTERFACE WITH
FLOW METER AND RAIN SHUT-OFF DEVICE)
• RADIO LINK KIT #89-7611 (TO COMMUNICATE WI CENTRAL COMMAND)
• GROUND ROD & SURGE PROTECTION FOR EACH 8000 UNIT
• ALL RADIO EQUIPMENT MUST BE COMPATIBLE WITH VHF
• RAINMASTER 32 PC "PIGTAIL" FOR REMOTE CONTROL OPERATION
• STRONG BOX 100% STAINLESS STEEL ENCLOSURE (24"X28"X48" HIGH)
LEGEND:
1. ELECTRIC CONTROL VALVE.
2. RECTANGULAR VALVE BOX WIGREEN
BOLT -DOWN COVER. HEAT BRAND VALVE
STATION NO. & CONTROLLER LETTEA ON Lit)
IN 2" HIGH CHARACTERS.
3. 2" CLEAR SPACE.
4. FINISH GRADE.
5. PVC MALE ADAPTER (TYP.)
6. PVC PIPE TO SPRINKLERS - ANGLE PIPE
TO SPECIFIED DEPTH WITH 45 DEG. ELLS.
T COMMON BRIOK (4 REQUIRED).
8. COMMON WIRE TO OTHER VALVES ON SAME
CONTROLLER.
9. 314" CRUSHED ROCK, 8"DEEP.
10, CONTROLICOMMON WIRES FROM CONTROLLER.
11. PVC SCHEDULE 40 PIPE (TYP.)
12. PVC SXS 90 DEG. ELL
13, WIRE CONNECTOR.
14. MAINLINE FITTING WISOLVENT-WILES OUTLET.
I& COIL WIRES PER SPECIFICATIONS.
16. CHRISTY$ I.D. TAG WIVALVE STATION NO. &
CONTROLLER LETTER.
NOTE:
USE TEFLON TAPE OR TEFLON PIPE DOPE ON ALL PVC TO PVC OR METAL
TO PVC MALE PIPE THREADS.
SCALE: N. T. S.
CLEAN BACKFILL - SEE SPECS
FOR MATERIAL 90% COMPACTION
C?CF1F II6CTi
HARDSCAPING (SEE NOTE #4)
ON
INN
0
IN W24;
W1 WAS wwrllm
PROVIDE 6" MIN. OF SAND TYP,
BEDDING AND SHADE7ING CONTROL WIRE SLEEVE -
SIZE PER PLAN, INSTALL
NON -PRESSURE LATERAL LINE ADJACENT TO PRESSURE
SLEEVE - SIZE TWICE DIAMETER ZM SUPPLY LINE.
OF NON -PRESSURE LATERAL
LINE
PRESSURE SUPPLY LINE SLEEVE -
SIZE TWICE DIAMETER OF PRESSURE
SUPPLY LINE
NOTES:
1. ALL SLEEVES TO BE SCH. 40 PVC.
2. EXTEND ALL SLEEVES 12" BEYOND EDGE OF HARDSCAPING AT BOTH ENDS.
3. ROUTE SLEEVING AROUND HANDICAP RAMPS,
4. PIPING UNDER PAVEMENT SUSCEPTIBLE TO TRAFFIC LOADS REFER TO CITY
STD. (24" MIN. TO 36" MAX. DEPTH TO TOP OF PIPE BELOW STRUCTURAL SECTION).
SLEEVING
SCALE: N.T.S.
LEGEND:
1. ROUND PLASTIC FULL BOX COVER BOLT DOWN TYPE,
2. FINISH GRADE LAWN AREAS.
3. FINISH GRADE SHRUB AREAS.
4. COMMUNICATION CABLE.
5. PEA GRAVEL. ( MIN. 2" CU. FT,)
NOTE: REMOTE CONTROL BOX MAY BE USED IN LIEU OF SPLICE BOX.
MATERIALS LIT SPLICE BOX ASSEMBLY
SCALE: N.T.S.
SCALE. N.T.S.
SCALE: N.T.S.
SCALE. N.T.S.
LEGEND:
2 1 3 1, PLASTIC VALVE BOX
2. U2 STAINLESS STEEL HOSE CLAMP. 3 REQUIRED.
11�1 _Illlll���� 3. QUICK COUPLING VALVE. TOP OF VALVE SHALL
- BE 2" 8ELOW VALVE BOX COVER.
111116=1111ll ll i-lllEi' 4. GALVANIZED NIPPLE, LENGTH AS REQUIRED,
5. PRESSURE SUPPLY LINE.
12 4 6. PRESSURE LINE FITTING.
Z 7. GALV. 90 DEGREE STREET ELL.
X_
5co
8. GALV. NIPPLE, LENGTH AS REQUIRED.
T_
° 9. #4 REBAR STAKE 36" LONG.
• • a ° ° a 10. GALV. 90 DEGREE STREET ELL.
° ° • ' ° + ° 40 0
0 fa a •
• ; . ° 11. GALV. 90 DEGREE ELL.
flff12. PEA GRAVEL, 2 CUBIC FEET MIN.
i 1 i0 € NOTE:
�! PLACE PEA GRAVEL PRIOR TO INSTALLATION
OF VALVE 80X.
SCALE: N.T.S.
SCALE: N.T.S.
SCALE: N.T.S.
IOLLER
LEGEND.
1. CAMPBELL SCIENTIFIC INC. TE525 TIPPING BUCKET
RAIN GUAGE, MOUNT TO MASONRY WALL OR
WOOD FENCE PER SPECIFICATIONS.
2. 112" 0. D. SCH, 40 GALVANIZED CONDUIT TO
BE SUPPLIED BY CONTRACTOR.
3. CONTROL WIRE/CABLE FROM RAIN GUARD
TO CONTROLLER.
4. CONCRETE FOOTING.
5. MASONRY WALL OR WOOD FENCE.
6. ATTACH CONDUIT TO WALLIFENCE WITH
GALVANIZED 'U'CLAMPS (3 MIN.).
7. FINISH GRADE.
S. SUB -GRADE.
CrrY OF FT, CALIFORNIA
DIAMETER SAME SIZE AS
METER SIZE
FLOW METER SIZE
TRACT! #15732
MINIMUM DISTANCE DOWNSTREAM OF
UNENTERRUPTI;E)PIPI (5X DIAMETER
DESIGNED BY:
FLOWMETER SIZE]
MINIMUM DISTANCE UPSTREAM OF
OAK
UNINTERRUPTED PIPE (10X DIAMEETER
11/17/97
OF FLOW METER SIZE}
APPROVED BY:
NOTE: WATERPROOF ALL WIRE CONNECTIONS.
SCALE: N.T.S.
61, POP-UP SP
SCALE: N.T.S.
'8"
_EGEND:
1. RADIO ANTENNA - LOCATION PER CITY OR
MANUFACTURER'S RECOMMENDATIONS.
?. METERED ASSEMBLY ENCLOSURE NEMA 3R
STAINLESS STEEL RAINPROOF ENCLOSURE
(UL LISTED).
3.
CONTROLLER/SATELLITE PER FRONT VIEW
CONTROLLER DETAIL.
I. METER SOCKET WITEST BLOCKS.
x. CLUSTER CONTROL UNIT OR SECOND
CONTROLLER/SATELLITE IF APPLICABLE.
#, LOAD CENTER
t. POURED CONCRETE BASE.
L 11/2" PVC CONDUIT OR PER LOCAL
ELECTRICAL CODES FOR 120 VAC POWER
TO POWER SOURCE.
1.
CONDUIT(S) PER FRONT VIEW CONTROLLER
DETAIL.
10. 10" DIA. X 12'D. BOTTOMLESS GROUND WELL
WITH PARKWAY COVER, FILL WITH PEA
GRAVEL.
11.518" DIA. X 10' DRIVEN GROUND ROD PER
ARTICLE 250.81 OF 1990 NEC.
NOTE: SEE MATERIALS LIST DETAIL M, SHEET ,L-$,
SC M . S.
HYDRA BOOST System to be a factory prepiped,
and prewired, unit mounted on a galvanized steel skid base,
With control panel, stainless steel fitted inline multistage pump
with flanged connections, single phase motor, interconnecting
piping and Wiring, pressure reducing/check valve, With by pass line.
System to be complete with galvanized steel powdercoated en-
closure mounted and delivered on a concrete pad.
HYDROBOOST MODEL 1L338SP 120 P2-3.0, CDEFHKLMN
SYSTEM TO CONSIST OF THE FOLLOWING:
PUMP: Ebara EVMU8-3 multistage pump With stainless steel
impellers and casing. Pump designed for 33 gpm @ 135.
3 HP, 3550 IPM, 230 , 1 phase, Close coupled to
the pump.
I Q ATIO YA VE r Watts full lug butterfly valves with 10
>_ position handles with stainless steel sterns and aluminum bronze
discs. Also a one in the by-pass.
PIPING; 21
1
schedule 40 steel of easy to disassemble flanged
construction bolted together With SS nuts and bolts. All piping
to be hot dipped galvanized after fabrication for long lasting corrosion
resistance.
PRVXHECK VALVE: 2" Berrnad 720-20, flanged PRV,
combination check, fusion bond epoxy coated.
to be fabricated from 3"x3" angle steel drilled with
mounting hales and large enough to have system enclosure bolted
to it. Base to be hot dipped galvanized after fabrication.
ENCAM RE.- 10 gage galvanized steel enclosure with hinged
cover. Enclosure to be bolted to skidbase with a powercoated
finish (desert tan). Cover has provisions for padlocks. -
(:t 1NUM-P N_EL NEMA 313, UL labeled door in door
deadfront enclosure made of 304 SS, padlockable containing:
(1) HOA selector switch
�3) 24V start relays
1) NEMA sized circuit breaker
(1 No flow Off rely With timer With 0-60 sec. tuner
1) Control transformer
(1) Mag. starter
-OPT , nes:
Waits FS20 flow switch for no flow off.
Gauges: 2.5" stainless steel backed, liquid filled With brass ball
valves. Gauge on suction/discharge lines.
BOOSTER PUMP NOTES
SCALE- N.T.. A A
LEGEND:
1. ROUND PLASTIC VALVE BOX & COVER MARKED "IRRIGATION GATE".
USE CHRISTY FL8 BOX & FL80 LID OR EQUAL.
2. FINISH GRADE.
3. GATE VALVE - SEE IRRIGATION LEGEND FOR MODEL#.
4. 31,V WASHED aCRUSED AGGREGATE BASE,
5. SCH. 40 PVC MALE ADAPTORS.
NOTE:
PLACE AGGREGATE PRIOR TO INSTALLATION OF VALVE BOX.
GATE VALVE
SCALE: N.T.S.
FINISH GRADE:
AS REQUIRED
lvMI
r
0150"
20,01
i � f
CONTROL §MIRES f`MIN. 2" OF CLEAN EARTH
NOTES:
1. BELOW PAVED AREAS A MINIMUM OF 6" LAYER OF CLEEAN FILL SAND SHALL BE
INSTALLED ABOVE AND BELOW PIPING.
2, PROVIDE MINIMUM COVER OF 24" ON PRESSURE SUPPLY LINES 3" AND LARGER.
3. WHEN USING RECLAIMED WATER, MAINTAIN MINIMUM 1 WHORIZONTAL SEPARATION
BETWEEN POTABLE AND RECLAIMED PRESSURE LINES. WHERE LINES CROSS,
PROVIDE PVC SLEEVE FOR POTABLE LINE MINIMUM 5' EACH SIDE OF RECLAIMED
WATER LINE.
4. BUNDLE WIRES WITH TAPE E=VERY 10'.
i
SCALE: N.T.S.
AUTOMATIC CONTROLLER MATERIALS LIST:
- TORO NETWORK 8000 SERIES 32 MOREL 132-86-08
- SENSOR INPUT BOARD (SII) MODEL 995-63 (TO INTERFACE WITH
FLOW METER AND RAIN SHUT-OFF DEVICE)
• RADIO LINK KIT #89-7611 (TO COMMUNICATE WI CENTRAL COMMAND)
• GROUND ROD & SURGE PROTECTION FOR EACH 8000 UNIT
• ALL RADIO EQUIPMENT MUST BE COMPATIBLE WITH VHF
• RAINMASTER 32 PC "PIGTAIL" FOR REMOTE CONTROL OPERATION
• STRONG BOX 100% STAINLESS STEEL ENCLOSURE (24"X28"X48" HIGH)
LEGEND:
1. ELECTRIC CONTROL VALVE.
2. RECTANGULAR VALVE BOX WIGREEN
BOLT -DOWN COVER. HEAT BRAND VALVE
STATION NO. & CONTROLLER LETTEA ON Lit)
IN 2" HIGH CHARACTERS.
3. 2" CLEAR SPACE.
4. FINISH GRADE.
5. PVC MALE ADAPTER (TYP.)
6. PVC PIPE TO SPRINKLERS - ANGLE PIPE
TO SPECIFIED DEPTH WITH 45 DEG. ELLS.
T COMMON BRIOK (4 REQUIRED).
8. COMMON WIRE TO OTHER VALVES ON SAME
CONTROLLER.
9. 314" CRUSHED ROCK, 8"DEEP.
10, CONTROLICOMMON WIRES FROM CONTROLLER.
11. PVC SCHEDULE 40 PIPE (TYP.)
12. PVC SXS 90 DEG. ELL
13, WIRE CONNECTOR.
14. MAINLINE FITTING WISOLVENT-WILES OUTLET.
I& COIL WIRES PER SPECIFICATIONS.
16. CHRISTY$ I.D. TAG WIVALVE STATION NO. &
CONTROLLER LETTER.
NOTE:
USE TEFLON TAPE OR TEFLON PIPE DOPE ON ALL PVC TO PVC OR METAL
TO PVC MALE PIPE THREADS.
SCALE: N. T. S.
CLEAN BACKFILL - SEE SPECS
FOR MATERIAL 90% COMPACTION
C?CF1F II6CTi
HARDSCAPING (SEE NOTE #4)
ON
INN
0
IN W24;
W1 WAS wwrllm
PROVIDE 6" MIN. OF SAND TYP,
BEDDING AND SHADE7ING CONTROL WIRE SLEEVE -
SIZE PER PLAN, INSTALL
NON -PRESSURE LATERAL LINE ADJACENT TO PRESSURE
SLEEVE - SIZE TWICE DIAMETER ZM SUPPLY LINE.
OF NON -PRESSURE LATERAL
LINE
PRESSURE SUPPLY LINE SLEEVE -
SIZE TWICE DIAMETER OF PRESSURE
SUPPLY LINE
NOTES:
1. ALL SLEEVES TO BE SCH. 40 PVC.
2. EXTEND ALL SLEEVES 12" BEYOND EDGE OF HARDSCAPING AT BOTH ENDS.
3. ROUTE SLEEVING AROUND HANDICAP RAMPS,
4. PIPING UNDER PAVEMENT SUSCEPTIBLE TO TRAFFIC LOADS REFER TO CITY
STD. (24" MIN. TO 36" MAX. DEPTH TO TOP OF PIPE BELOW STRUCTURAL SECTION).
SLEEVING
SCALE: N.T.S.
LEGEND:
1. ROUND PLASTIC FULL BOX COVER BOLT DOWN TYPE,
2. FINISH GRADE LAWN AREAS.
3. FINISH GRADE SHRUB AREAS.
4. COMMUNICATION CABLE.
5. PEA GRAVEL. ( MIN. 2" CU. FT,)
NOTE: REMOTE CONTROL BOX MAY BE USED IN LIEU OF SPLICE BOX.
MATERIALS LIT SPLICE BOX ASSEMBLY
SCALE: N.T.S.
SCALE. N.T.S.
SCALE: N.T.S.
SCALE. N.T.S.
LEGEND:
2 1 3 1, PLASTIC VALVE BOX
2. U2 STAINLESS STEEL HOSE CLAMP. 3 REQUIRED.
11�1 _Illlll���� 3. QUICK COUPLING VALVE. TOP OF VALVE SHALL
- BE 2" 8ELOW VALVE BOX COVER.
111116=1111ll ll i-lllEi' 4. GALVANIZED NIPPLE, LENGTH AS REQUIRED,
5. PRESSURE SUPPLY LINE.
12 4 6. PRESSURE LINE FITTING.
Z 7. GALV. 90 DEGREE STREET ELL.
X_
5co
8. GALV. NIPPLE, LENGTH AS REQUIRED.
T_
° 9. #4 REBAR STAKE 36" LONG.
• • a ° ° a 10. GALV. 90 DEGREE STREET ELL.
° ° • ' ° + ° 40 0
0 fa a •
• ; . ° 11. GALV. 90 DEGREE ELL.
flff12. PEA GRAVEL, 2 CUBIC FEET MIN.
i 1 i0 € NOTE:
�! PLACE PEA GRAVEL PRIOR TO INSTALLATION
OF VALVE 80X.
SCALE: N.T.S.
SCALE: N.T.S.
SCALE: N.T.S.
IOLLER
LEGEND.
1. CAMPBELL SCIENTIFIC INC. TE525 TIPPING BUCKET
RAIN GUAGE, MOUNT TO MASONRY WALL OR
WOOD FENCE PER SPECIFICATIONS.
2. 112" 0. D. SCH, 40 GALVANIZED CONDUIT TO
BE SUPPLIED BY CONTRACTOR.
3. CONTROL WIRE/CABLE FROM RAIN GUARD
TO CONTROLLER.
4. CONCRETE FOOTING.
5. MASONRY WALL OR WOOD FENCE.
6. ATTACH CONDUIT TO WALLIFENCE WITH
GALVANIZED 'U'CLAMPS (3 MIN.).
7. FINISH GRADE.
S. SUB -GRADE.
CrrY OF FT, CALIFORNIA
ORAE L��
JAIL
INDEPENDENCE INCE c MORNINGSIDE
sc�;LE:
AS SHOWN
TRACT! #15732
40 M
DESIGNED BY:
�i
COMMUNITY FACILr I-�RI�-
DATE:
OAK
U.
0
11/17/97
CHECKED BY:
APPROVED BY:
DWG. NO.:
0
RK
DATA:
2883
�l
0
lT f ENGINEER R.C.&: 6 EXP. DATE
WW
W
SCALE. N.T.S.
006 2893 IT of 4Z It
i TE PLAN N ANG
10630 To= CemMar Mr.,, ,%xifte11M
Rancho Cucawonn�p„ CA 9117/
(909) 484-2800
Fax 1909) 494-2802
Richard Kruinziede
CA Lie, #OM AZMD.#0MM WkWOW6
DSCAP
k 111�
JAI
R
y21
s�a,re
IRenawa[D
�Iq
Date
OF C A,
3l26IO2 ON-SITE CITY
CORRECTIONS ADD-
A55JAI= ED BOOSTER PUMP
JA
11117/97 3/26/32
0B NUMBE F
low6
OF SHTS.
Z
V
40 M
r
LL
Lj�
(j
U.
0
.
0
Uj
0
2cc
Uj U�
0
CZ
WW
W
cc
CL
I
10 Z
Z
W
LO
Z
C)
0
W
•
LU
Z
Uj
.�..�
_j
3l26IO2 ON-SITE CITY
CORRECTIONS ADD-
A55JAI= ED BOOSTER PUMP
JA
11117/97 3/26/32
0B NUMBE F
low6
OF SHTS.