HomeMy WebLinkAbout2882-I-3_2REDUCE PRESSURE BACKFLOW BRASS NIPPLE (4 PREVENTION PLACES) d PRESSURE REGULATOR IF REQUIRED. SET AS SHOWN BRASS ELBOW 1 2 ON SITE DRAWING eWHITE LEGEND; LEGEND: BLUE * 1" IN LAWN AREAS BRASS NIPPLE SNAP -TITS WATERPROOF 3" IN PLANT BEDS 1. ELECTRIC CONTROL VALVE. STRAINER #40 MESH CONNECTOR OR EQUAL * NTE: INSTALL STREAM ROTOR SHRUB HEADS 12" FROM 1, STREAM ROTOR SHRUB HEAD. MONEL BRASS UNION IRRIGATION CONTROLLER RED 15 16 13 1 2 4 2. RECTANGULAR VALVE BOX W/GREEN APJACENT TRACT PERIMETER WALLS. BACKFLOW ENCLOSURE BLACK PIG TAIL EXPANSION BOLT -DOWN COVER. HEAT BRAND VALVE 2. ANTI -DRAIN VALVE. (SEE NOTE BELOW) : STATION N0, &CONTROLLER LETTER ON LID BLUE LOOP (MIN, 24" LONG) IN 2" HIGH CHARACTERS. 1 3. PVC SCH, 80 NIPPLE. BRASS BALL VALVE WHITE P i - 8 4. FINISH GRADE. ■ BRASS PIPE PLASTIC VALVE BOX (CARSON OR (COMMON) 3 0. - 3. 2" CLEAR SPACE, ' EQUAL) WITH PLASTIC INTEGRATED PO LOCKING 4. FINISH GRADE, b, V.I.T. PRODUCTS PS -118 #4X18" RE -BAR ROD W! � .A N [� S C A P E BRASS ELBOW HINGE (2 PLACES) LOCKING LID. PLACE AT GRADE IN ae 12 11 5 6 TURF AREAS AND 3" ABOVE IN DOUBLE "J" HOOKED RAD, AT ONE END TO HOLD LOOSE KE RED BLACK 5. PVC MALE ADAPTER (TYP,) 2 PIPE SECURELY IN PLACE, INSTALL 10' O.C. ARCH ITE C T U R E BRASS NIPPLE HOSE BIBB 1 PLANT BED. BRASS BALL VALVE ' ' • •. • ' • ac 6. PVC PIPE TO SPRINKLERS - ANGLE PIPE 6. SCH. 40 BROWNLINE PVC LATERAL UNE PIPE INSTALL ON BRASS PIPE .. • . - • ''- • '',-'• 4 ,' © 0 17 TO SPECIFIED DEPTH WITH 45 DEQ. ELLS. 7 GRADE. S ITE PLANNING ,,... -• - , PIG TAIL EXPANSION - o• , • 10630 Town Center Dr., Suite 128 LOCK BOX ., • : ' . ,-: ; • , • ' ' LOOP (MIN. 24" LONG) OF 14 ° • •• 3 • 7. COMMON BRICK (4 REQUIRED), = 3 7, V.I.T. PRODUCTS SS -24 SPRINKLER STABILIZER. Rancho Cucamonga, CA 91730 1" PVC CONDUIT TO 7 (909) 484-2800 - •• - .' ••', •'; • : ' PRESSURE SUPPLY LINE .IBES (DISCHARGE) ax (9091 484-2802 ' •' • - , •, • , • • CONTROLLER X8. COMMON WIRE TO OTHER VALVES ON SAME 8. V.I.T.,,, PRODUCTS #ST9 SPRINKLER TIES (2 REQ'D.) .. • . - , • , ... - MASTER CONTROL � 6 • PEDESTAL 5 CONTROLLER. • • - • ' ' • . ' • ' VALVE LEGEND: - - 9 PVC SCH 40 TEE OR L CA Lic #2834 AZ Li 911 9 Richard Krumwiede . -ELL. 'o. # 2 5 NV Lio. # 446 • ' • • 9. 3/4" CRUSHED ROCK, 8" DEEP, _ ' ' 1. ROUND PLASTIC VALVE BOX & COVER MARKED "IRRIGATION GATE". 14 10 B $ .. ., - • ' - • • - FLOW METER - USE CHRISTY FL8 BOX & FL80 LID OR EQUAL. 4 - ' - MALE ADAPTOR PVC SCH. 40 10. CONTROL/COMMON WIRES FROM CONTROLLER. • - '�'''•. • ' DIAMETER SAME 2. FINISH GRADE. ` • BLASS ELBOW (DO NOT ENCASE SIZE AS FLOW • - ' •' ' 3/4" GRAVEL DIAMETER SAME SIZE AS 3. GATE VALVE - SEE IRRIGATION LEGEND FOR MODEL#. 11. PVC SCHEDULE 40 PIPE (TYP,) STAINLESS STEEL IN CONC. STABILIZER METER SIZE \ ID SC A p$ FLOW METER SIZE "U" BOLT EMBEDDED to 4. 3/4" WASHED CRUSED AGGREGATE BASE. 12. PVC SXS 90 DEG, ELL / KrurT?�yj '�•Q MINIMUM DISTANCE DOWNSTREAM OF 5. SCH. 40 PVC MALE ADAPTORS. 13. WIRE CONNECTOR. a IN CONCRETE FOR BRASS ELBOW LOCKING FEATURE CONC. STABILIZER��• a NOTE: BACKFLOW ENCLOSURE: LE MEUR UNINTERRUPTED PIPE (5X DIAMETER ' OR EQUAL WXWX34: HIGH & OF FLOW METER SIZE) � Wp, ) '�•• NOTE: 14. MAINLINE FITTING W/SOLVENT-WELD OUTLET. 5 a HINGED AT ONE END. SECURE TO MINIMUM DISTANCE UPSTREAM OF NOTE:re 6"X8" FOOTING W/ 4" "J" BOLTS. UNINTERRUPTED PIPE10X DIAMEETER PIPE(10X AGGREGATE PRIOR TO INSTALLATION OF VALVE BOX. USE TEFLON TAPE OR TEFLON PIPE DOPE ON ALL PVC TO PVC OR METAL 15. COIL WIRES PER SPECIFICATIONS. � a i PRESSURE SUPPLY LINE (EQUIPMENT TO BE CENTERED OF FLOW METER SIZE) TO PVC MALE PIPE THREADS, INSIDE HOUSING) (INTAKE} 16. CHRISTY'S I.D. TAG WNALVE STATION NO. & ate NOTE: WATERPROOF ALL WIRE CONNECTIONS. CONTROLLER LETTER, QF 17. UNION BACKFLOW PREVENTER FLOW METER/MASTER VALVEGATE - VALVE REMOTE CONTROL VALVE HRUB STREAM ROTOR CSN RISER SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. 24" 2 (D Ts V r-•� 28" 6 7 m 1 2 LEGEND: n 1 2 LEGEND: 4 5 LEGEND: O 1. HI -POP SHRUB ROTOR SET 1/2" ABOVE 1 2 _� LEGEND: FINISH GRADE. a 1. HI -POP SHRUB HEAD BODY SET 114 ABOVE c 8 8 i 1. RADIO ANTENNA , LOCATION PER CITY OR �'� , 4 FINISH GRADE. 1. POP-UP SPRAY HEAD. �... MANUFACTURER'S RECOMMENDATIONS, 2. FINISH GRADE. 5y 8 1 2 g 1 FOOTING i 3 •� 2. FINISH GRADE. 2. WALK OR CURB. 13 1 12 2, METERED ASSEMBLY ENCLOSURE NEMA 3R V 3. SCH, 40 PVC 90 DEGREE STREET ELL. STAINLESS STEEL RAINPROOF ENCLOSURE • 3. PVC SCH. 80 NIPPLE - 4" MIN. LENGTH. L S. SCH. 40 PVC 90 DEGREE STREET ELL. 4" LEGEND:. (UL LISTED). 4. MARLEX 90 DEGREE STREET ELL, \ 4 0 C� 4. PVC TXT 90 DEG. ELL. 4. MARLEX 90 DEGREE STREET ELL. 10 1. RADIO ANTENNA - LOCATION PER CITY OR MANUFACTURER'S 3. CONTROLLER/SATELLITE PER FRONT VIEW kx,., txj 5. SCH. 80 PVC NIPPLE TYPICAL (2) PLACES. 5. LATERAL LINE PIPE AND FITTING. RECOMMENDATIONS. CONTROLLER DETAIL, 1=4 00 z 5. SCH. 80 PVC NIPPLE TYPICAL (2) PLACES. 2. 24" FRONT ENTRY SATELLITE ASSEMBLY NEMA 3R STAINLESS 6. MARLEX 90 DEG. STREET ELL. 11 STEEL RAINPROOF ENCLOSURE (UL LISTED). t„J 6, ANTI -DRAIN VALVE AS REQUIRED. Z '� 3. MASTER VALVE RELAY OR PUMP START RELAY, 4 6 10 4. METER SOCKET WREST BLOCKS. ` ""' J w / 6. MARLEX 90 DEGREE STREET ELL. 7. PVC SCH. 80 NIPPLE - 6" LONG. 4. RADIO REMOTE ACCESS.-.� 7. MARLEX 90 DEGREE STREET ELL. 14 5. 1 1/2" PVC CONDUIT FOR 120 VAC FROM METERED POWER ' "•moi 9 b. CLUSTER CONTROL UNIT OR SECOND 3 8. FINISH GRADE. SUPPLY OR PER LOCAL ELECTRICAL CODES. I I 4 e Q 7. NON -PRESSURE LATERAL FITTING. 6 7 6 13 6. POWER SWITCH/QFI RECEPTACLE. a , _ : a CONTROLLER/SATELLITE IF APPLICABLE. -� 8. NON -PRESSURE LATERAL FITTING. * 1" IN TURF AREAS. 7. SATELLITE. 4 3" IN PLANTING BEDS. 8. 1 1/4" PVC CONDUIT FOR COMMUNICATION CABLE. 8. NON -PRESSURE LATERAL LINE. �? L 6. LOAD CENTER 9. NON -PRESSURE LATERAL LINE, -` °o 9. PVC CONDUIT FOR CONTROL WIRES, SIZE AS REQUIRED. 3 NOTES: 10. V PVC CONDUIT FOR FLOW SENSOR CABLE. �`; r 7POURED CONCRETE BASE. 11. 1 1/4 PVC CONDUIT FOR COMMUNICATION CABLE TO OTHER . - 3 NOTES: SATELLITES ((IF APPLICABLE). s ,� 7 a 11 1. LOCATE HEAD 2" TO 4" FROM WALKS, CURBS 8" MIN 12.5/8" DIA. X V i ROUND ROD W/#10 GROUND WIRE & CLAMP. 8. 11/2" PVC CONDUIT OR PER LOCAL Q HARDSCAPING, MOW STRIPS, AND EDGES OF 1. LOCATE HEAD 2" TO 6" FROM WALKS, 13. POURED CONCRETE FOOTING. N s x CURBS "= 14. FILL VOIDS WITH CONCRETE, ` jY ,�.;,• ,s' ELECTRICAL CODES FOR 120 VAC POWER AWN HARDSCAPING, MOW STRIPS, AND EDGES OF NOTE: 32 • ' TO POWER SOURCE. 4 USE TEFLON TAPE OR TEFLON PIPE DOPE ON !.... LAWN. ALL PVC TO PVC OR METAL TO PVC MALE PIPE "•r•' 2. USE TEFLON TAPE ON ALL MALE THREADS. 4 5 THREADS. 12 - ;'!?• 9, CONDUIT(S) PER FRONT VIEW CONTROLLER 8 7 6 5 3. INSTALL HEADS WITH INTERNAL CHECK VALVE 2, USE TEFLON TAPE ON ALL MALE THREADS. FRONT VIEW 37" DETAIL. AND PRESSURE COMPENSATING FEATURE AS 8 7 6 S 3. INSTALL HEADS WITH INTERNAL CHECK VALVE NOTE: SEE MATERIALS LIST LOCATED NEXT 10.10" DIA. X 12" D. BOTTOMLESS GROUND WELL PER THE IRRIGATION PLAN. AND PRESSURE COMPENSATING FEATURE AS TO EACH CONTROLLER ON SHEETS I.1, 5, & 6. WITH PARKWAY COVER, FILL WITH PEA PER THE IRRIGATION PLAN, GRAVEL. -NETWORK 8000 CONTROLLER, RADIO, RADIO LINK, 4. HEAD CONNECTION AT BOTTOM INLET ONLY. POWER SUPPLY, & SENSOR INPUT BOARD INSTALLED 4. HEAD CONNECTION AT BOTTOM INLET ONLY. ON BACKBOARD 11, b/8" DIA, X 10' DRIVEN GROUND ROD PER NOTE: $EE MATERIALS LIST LOCATED NEXT ARTICLE 250-81 OF 1990 NEC, -CONTRACTOR TO THROW AWAY PEDESTAL TO EACH CONTROLLER ON SHEETS 1.1, 5, & 6. TEMPLATE AFTER USE. DO NOT LEAVE UNDER CABINET. 12"STREAM RQTOn 1 PCWP -UP SPRAY HEAD 6" POP-UP SPRAY HEAD IRRIGATION CONTROLLER - FRONT VIEW - IRRIGATION CONTROLLER - SIDE VIEW SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. LEGEND FINISH GRADE 1. 4" DIA. STEE POST CAP. SECURE TO PIPE. NN U) 1 2. TIPPING BUCKET BRACKET. 1 � 3. 1/2 DIA. FLEXIBLE ALL-WEATHER ELECTRICAL AS REQUIRED 12 4 CONDUIT, CONNECT BOX TO BOX. x x x x CLEAN BACKFILL -SEE SPECS �� FOR MATERIAL 90% COMPACTION HARDSCAPING (SEE NOTE #4) MIN. 4. TIPPING BUCKET RAIN GUAGE, INSTALL PER LEGEND' X x X X x 2 REQUIRED MANUFACTURER'S RECOMMENDATIONS. 2 1 3 1. PLASTIC VALVE BOX x x XX x x 6 3 x x x x x X 3 x ., 5. 4" DIA. GALVANIZED STEEL PIPE POST. 2. 1/2" STAINLESS STEEL HOSE CLAMP. 3 REQUIRED. •' ' ' ' X " •' ' '' ' '•' ' ' 2 6. WEATHER-PROOF ELECTRICAL'J' BOX. DRILL 1" DIA. HOLE THROUGH PIPE & MOUNT BOX �I = _ = III = I - 3. QUICK COUPLING VALVE. TOP of VALVE SHALL _IIIIII _IIIIII - I I -IIIII _ BE 2 BELOW VALVE BOX COVER. �..�..� TO PIPE. '1111=IIIIII= � r» 7. SLOPE TOP OF FOOTING AWAY FROM PIPE. IIIIII=IIIIII IIIII-III�� 4. BRASS NIPPLE, LENGTH AS REQUIRED. J NON -PRESSURE S. PRESSURE SUPPLY LINE. ,, LATERAL LINE 8. FINISH SURFACE. N 12 4 9. NATURAL COMPACTED SOIL. 6. PRESSURE LINE FITTING. 4 _• • • . • �� g _ 6 ry Z 7. BRASS 90 DEGREE STREET ELL 5 PROVIDE 6" MIN. OF SAN© (■�■,� *- 10. 1" DIA. ELECTRICAL PVC FROM PIPE TO BEDDING AND SHADDING TYP. 3'-4' MAX. CONTROLLER. 5 $� 8. BRASS NIPPLE LENGTH AS REQUIRED. :'. �sl� CONTROL WIRE SLEEVE - E • .•,'. ' . T- a , • •: SIZE PER PLAN, INSTALL AN BACKFILL - 31 -41 • ;.;' ' /a COMPACTION ' 11. PROPOSED CONTROLLER ENCLOSURE. ° ° 9. #4 REBAR STAKE 36" LONG. . '••''•'; NON -PRESSURE LATERAL LINE ADJACENT TO PRESSURE • .•,'.•,'.•,`. ',•,'.• ` PRESSURE SUPPLY LINE • o • . SLEEVE •SIZE TWICE DIAMETER SUPPLY LINE. . , , ,,.•, . i a.•,'.•,'.•,'.•,',•, • ' tea, 12. STAINLESS STEL HOSE CLAMPS, (2) EACH. o ° + . 10. BRASS 90 DEGREE STREET ELL. '• • OF NON -PRESSURE LATERAL 11 ° O .•. . • •O ". •• 11. BRASS 90 DEGREE ELL. '`. ':;'..�; .;' LINE NOTE: 12. PEA GRAVEL, 2 CUBIC FEET MIN. C NTROL WIRES MIN. 2" OF CLEAN EARTH ACID WASH STEEL PIPE POST, STEEL POST CAP PRESSURE SUPPLY LINE SLEEVE - SIZE TWICE DIAMETER OF PRESSURE AND ELECTRICAL'J' BOX THOROUGHLY. PAINT SUPPLLINE 7 1 B�= 8 WITH (1) COAT RUSTOLEUM PRIMER AND (2) COATS LEGEND: NOTES: OF FOREST GREEN EXTERIOR HIGH GLOSS PAINT. Y 1. ROUND PLASTIC FULL BOX COVER BOLT DOWN TYPE.1. BELOW PAVED AREAS A MINIMUM OF W LAYER OF CLEAN FILL SAND SHALL BE NOTES' INSTALLED ABOVE AND BELOW PIPING. p 11 10 9 8 7 6 2. FINISH GRADE LAWN AREAS. 1. ALL SLEEVES TO BE SCH. 40 PVC. Z 2. PROVIDE MINIMUM COVER OF 24" ON PRESSURE SUPPLY LINES 3" AND LARGER. 3. FINISH GRADE SHRUB AREAS. 2. EXTEND ALL SLEEVES 12" BEYOND EDGE OF HARDSCAPING AT BOTH ENDS. a: © 3.. WHEN USING RECLAIMED WATER, MAINTAIN MINIMUM 10' HORIZONTAL SEPARATION _ NOTE: 4. COMMUNICATION CABLE .3. ROUTE SLEEVING AROUND HANDICAP RAMPS. BETWEEN POTABLE AND RECLAIMED PRESSURE LINES. WHERE LINES CROSS, N PLACE PEA GRAVEL PRIOR TO INSTALLATION PROVIDE PVC SLEEVE FOR POTABLE LINE MINIMUM 5' EACH SIDE OF RECLAIMED cl�aOF VALVE BOX, 5. PEA GRAVEL. ( MIN. 2" CU. FT.) 4. PIPING UNDER PAVEMENT SUSCEPTIBLE TO TRAFFIC LOADS REFER TO CITY WATER LINE. -� • • STD. (24" MIN. TO 36" MAX. DEPTH TO TOP OF PIPE BELOW STRUCTURAL SECTION). • • • : 4, BUNDLE WIRES WITH TAPE EVERY 10'. �11--*Np• 9 10 NOTE: REMOTE CONTROL BOX MAY BE USED IN LIEU OF SPLICE BOX. TIPPING BUCKET QUICK COUPLING VALVE SPLICE BOX ASSEMBLY SLEEVING TRENCHING SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. SOALE: N.T.S. 570 SERIES PCD SCREEN SELECTION CHART X x'S, V PRESSURE- COMPENSATING DEVICE '=- 0.1 0.25 0.5 0.7 1 1.4 2 3 NOZZLE RAD GPM RAD GPM RAD GPM RAD QPM RAD GPM RAD QPM RAID GPM RAD QPM 8H 4 _M 7 AN- 8 &M 9 1,12 10 _1,1L 10 1.19 10. ins \j ■a i JRB 1-50 3 A. A= .2 1 17 In . L= .14. 2.UL lL = N CITY OF FONTANA, CALIFORNIA BE 9/30/99 ISH 3 082 11 15 17 1 2AA 17 2-71. 7, ISTT 2 AUk 3 _0.� a A_2J_ _J2__ -tlk 16 0-M 19 2.75 l2k DRAWN BY; �AI,E; Q_SST5X2 7X10 X12 9X18 1X22 1 1X22 FORECAST @ NORTH MORNINGSIDE 1 X6 2X20 X24 4X30 X34 034 X34 :?: JRA TRACT. X14775 AS SHOWN • 1x 2X2o x2a 4x30 x3a x34 x34 - =' LANDSCAPE MAINTENANCE DISTRICT' IDATE: AS SHAWN - 1X8 4X18 X18 4X18 - X18 X16 018 2X6 4x18 x1 4X1e x20 x20 020 JAB 9138/99 - - 2xs � �• fDq. NO.: HECKID 13 , APPROv� • X DATE' :•...,,RWK V. CITY ENGINEER R G E, 25126 EXP. DATE 12 lig Z.99043-5 - PD SCREEN CHART THRUST BLOCK SCALE: N.T.S. SCALE: N.T.S. SCALE: N,T.S.1=3 SCALE: N.T,S. SCALE: N.T.S. OF SHTS.