Loading...
HomeMy WebLinkAbout2116-E2_1El IB Ic I ._k IE IF IG r Pi �� (rt'� K�rtAl�l ur�GFb°�JG,�A� �ew Imo. + Lc 4 ��,p , Ta G I J MAW M �. 2t�,� /, 10 p to , slogr �MILLI ! I x- Mesf, I I rAP tv-A1 , FLA+ Z5 5�1-e�-re-r +L4L &S o 141 A ,',4400 m4m] s �.. olc.+ i ►�T I �«T4l._... __.. 1 S>4 Kv-r4 , S:06 &_u_)-r44� -- L _I,�,i.l.. 4D�r�,1- "7,I C ]— 414 At'i r- h LE LIA1, , fes. ---------------------------------- ._�._-__---_____-______-____1_ ____-________ GELNE'RAL N0Tt;S FIXTURE SCiHEDUL,E. ___—___ _____ __—._________________r_—______—___________________—__—__ ___ I { LAMP DATA 1. INSTALLATION, MAINTENANCE, AND USE SHALL CONFORM WITH 181 NEC, MARK WATTS* TYPE Q'I'Y NO TYPE WATT REMARKS TITLES 8,20124 C.A.C., PROJECT SPECIFICATIONS AND LOCAL ------------------------------*__—_______—_-------______------------------- IREQUIREMENTS A 160 RECESSED 2 x 4 12 4 F'40T12. 40 KEENE HEFT/ST 2. PLANS SHOWN ARE SCHEMATIC IN NATURE:, THEREFORE IT IS THE FLUOR. WITH VIRGIN ;tXB440 RESPONSIBILITY OF THE CONTRACTOR TO CONFIRM ALL CONDITIONS ACRYLIC LENS OR APPROVED E. IN FIELD IN AN EFFORT TO PROVIDE A SAFE, ECONOMICAL AND MAIN— TAINABLE INSTALLATION: B 80 WALL—MOUNTED FLUOR 2 2 1`40T12 40 KEENE W/ PRISh1/ACRY LENS CELEBRI`T'Y/WA 3. CONTROL WIRING SMALL BE BY MECHANICAL CONTRACTOR, POWER DOWN'N'UPLIGHT #DC240 WIRING SHALL BE BY ELECTRICAL CONTRACTOR. ELECTRICAL CON— OR APPR. EQ. TRACTOR SHALL PROVIDE EMPTY CONDUITS FOR CONTROL WIRING AS C 100 PORCELAIN MOGUL— 1 1 A19 100 FINAL SELECZ'IO SHOWN ON DRAWINGS. CONFIRM CONDUIT LOCATIONS WITH MECHANICAL CONTRACTOR PRIOR TO INSTALLATION. BASE LAMP BY ELEC. CONTRI F 4. RECESSED LIGHTING FIXTURES SHALL HAVE A CLEARANCE OF' 1/2" FROM 13 D 100 SHALLOW REFRACTOR 12 _l ��lV 100 MARCO jtMN6304E � COMBUSTIBLES AND 3" FROM INSULATION. RECESSED DOWNLIGH`I` (B25) OR APPR. EQ. 5. WIRING THROUGH FIXTURES SHALL BE TYPE THHN OR APPROVED EQUAL WITH POLYCARBONATE WITH 90 DEG. C RATED INSULATION. LENS IN WHITE FINISH TRIM AND WITH .6. "LOCK—OFFS" SHALL BE PROVIDED ON ALL CIRCUIT BREAKERS WHICH "TAMPER—PROOF" SERVE AS SWITCHES FOR UNSWITCHED LIGHTING FIXTURES NOT IN HARDWARE. SIGHT Of PANEL. E 160 2x4 WRAP—AROUND 4 4 F40T12 40 KEENE 7. BOND WIRES SHALL BE PULLED IN ALL NON ,—N►E'lALLIC CONDUITS AND IN FLUOR. WITH VIRGIN DOMINAIRE/SU ACRYLIC LENS OMINAI FLEXIBLE METAL CONDUIT OVER 6' IN LENG'T'H. ALUMINUM FLEXIBLE CONDUIT SHALL NOT BE USED. OR APPR. EQ. 8. PRIMARY GROUND SHALL BE UFER AND SECONDARY GROUND SHALL BE ------------------------------.._____—_____________--__—_----_________________ 3/4" x 10' COPPERWELD GROUND ROD. METALLIC GAS AND WATER PIPING SHALL 13E BONDED TO GROUND. * TOTAL WATTAGES SHOWN DO NOT INCLUDE BALLAST LOSSES. ELECTRICAL CONTRACTOR SEIALL, WHEREVER POSSIBLE, USE ENERGY—SAVING BALLASTS. 9. ELECTRICAL CONTRACTOR SHALL SUBMIT THREE (3) COPIES OF EQUIPMENT SUBMITTALS PRIOR TO CONSTRUCTION FOR APPROVAL BY ENGINEER, AND SHALL, I ---------------------- ------------- ------------------------------------------- UPON COMPLETION, PROVIDE ENGINEER WITH TWO (2) COPIES OF 'AS—BUTLTS' PRIOR TO COMPLE'T'ION OF CONTRACT (IF ANY SIGNIFICANT CHANGES IN CIRCUITRY ARE MADE) . LIGHTING SUBMITTALS MAY BE APPROVED BY OWNER. -----___------_—_--__________________-------------,_-_____ —__—__ _---_-- � l2@/208V, 3PET, 4W, SN PAN EL -100 A. BUS 11. ELECTRICALCONTRACTOR SHALL LEGIBLY 'PRINT (OR TYPE) ALL PANEL INFORMATION FLUSH MTD. 'LD" MAIN LUGS ONLY AND AF'F'IX TO EACH PANEL PRIOR TO COMPLETION. ALSO, EACH PANEL SHALL BE ------------------------------------ •-------- ________________________________ SECURELY FASTENED TO STRUCTURE IN ACCORDANCE WITH MFR'S INSTRUCTIONS AND CKT BRKR OUTLETS PHASE (WATTS) DESCRIPTION SHALL BE BRACED AGAINST SEISMIC LOADING. NO A/P LTS REC APPL A B C ------------------------------------------------------------------------------- 12. UNLESS OTHERWISE, NOTED, < ALL WIRING SHALL BE COPPER TYPE THW. UNDERGROUND' 1 20/1 8 1400 LIGHTS—SEN CIT,CRAF'TS BRANCH CIRCUITS SHALL BE INSTALLED IN CONDUIT. 2 I 8 1440 RECEPT—SEN CIT,CRAF'TS 3 I 5 1000 LIGHTS—SEN CIT,CRAFTS 13. ELECTRICAL CON`T'RACTOR MAY ROUTE CIRCUITS AT OWN DISCRETION, HOWEVER, THE 4 I 9 1620 RECT PT --CRAFTS, OFC,WT RM CIRCUIT NUMBERS SHOWN ON PLANS SHALL REMAIN UNCHANGED UNLESS APPROVED 5 I 6 940 LIGHTS—WT RM,OFC,JAN BY ENGINEER. 6 i 9 1620 RECEPT—CRAFTS,WT RM,JAN *7 v 11 1200 DOWN LIGHTS—EXTERIOR 8 — — SPACE 9 20/1 1400 SPARE 10 — -- SPACE 11 20/1 1500 SPARE ----------------------------------------------------------------------------- SUB—TOTALS 4, 040 4, 020 4, 060 TOTAL(W) 12,120 W. TOTAL FLA: 33.6 A. LCL AMPS : 5.4 A. FLA + LCL: 39.0 A. SPEC. SQUARE D NQQ,NQOB OR APPROVED EQUAL (12 CKT,100 A. BUS) ----------------------------------------------------------------------------- * CIRCUIT ROUTED THROUGH TIME CLOCK CONTROLLED MECH.—HELD LIGHTING CONTACTOR r o ZLLJ CIN�W..� Q � W J)WJ70 s 0 0- 0 W a O LL uj a zzQ U ® Z Z i .m. 0 LL i z ® � Z Lu ® a LL >= a r a k Lcl cD SHEET im 4 X OF 'ZC� J)WJ70 s