HomeMy WebLinkAbout3079-20LIGHTING NOTES (D ALL SITE LIGHTING CONDUCTORS ARE #12 THHN/THWN-CU UNLESS OTHERWISE NOTED. FOR SITE PLAN MINIMUM 3/4" PVC SCHEDULE 40 UNDERGROUND CONDUIT. INSTALL UNDERGROUND CONDUIT PER ARTICLE N.E.G. TABLE 300-5. O INSTALL (2) 1" G.O. STUB OUT OF CONGRETE FOUNDATION AT El FGTRIGAL PANEL FOR FUTURE USE. SEE "LOCATOR DETAIL'. O3 FOR OUTDOOR LIGHTING BRANCH CIRCUITS FROM BUILDING, INSTALL A RECESSED 45,2 1/8" (MIN.) DEEP J -BOX WITH 2 -GANG SWITCH RING GASKET WEATHERPROOF BLANK METAL COVER AT +12" OTYPICAL. OMINIMUM OF I" CONDUIT FROM PANEL TO FIRST LIGHTING FIXTURE OR PULL BOX. 5 LIGHTING FIXTURES IN CONTACT WITH INSULATION WILL BE U.L LISTED FOR THERMAL BARRIER. ALL BALLASTS FOR INDOOR 4 FT. FLUORESCENT IN COMMON AREA SUCH AS RECREATION, LAUNDRY, AND OMAINTENANCE BUILDING SHALL BE 'ENERGY SAVING TYPE' GBM, GEC AND U.L LISTED. 6 ALL EQUIPMENT SHALL BE MOUNTED, SUPPORTED ACCORDING TO THE OSHA REQUIREMENTS AND U.L. OLISTED. PROVIDE ALL MATERIALS, AND LABOR, TO PERFORM ALL TASKS NECESSARY TO ACHIEVE A �8 COMPLETE ELECTRICAL INSTALLATION. COMPLETION OF JOB SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR AFTER THE DATE OF ACCEPTANCE BY OWNER. ANY WORK, MATERIAL OR EQUIPMENT FOUND TO BE FAULTY DURING THAT Oq PERIOD SHALL BE CORRECTED AT THE EXPENSE OF THE ELECTRICAL CONTRACTOR. PROVIDE THE OWNER WITH ONE (1) SET OF COMPLETE ELECTRICAL 'AS BUILT' AT THE COMPLETION OF 10 THE JOB. GALL RECEPTACLES, SWITCHES, AND COVER PLATES SHALL BE WHITE NOT IVORY. 12 ALL ELECTRICAL EQUIPMENT, BREAKERS, AND TIME SWITCHES DIRECTORY SHALL BE PROPERLY LABELED. 13 ELECTRICAL SYSTEM LAYOUTS ARE GENERALLY DIAGRAMMATIC. EXACT ROUTING OF WIRING, OUTLETS, AND EQUIPMENT TO BE GOVERNED BY STRUCTURAL CONDITIONS AND OBSTRUCTION. THE WORK COVERED ON THESE DRAWINGS SHALL INCLUDE THE FURNISHING OF ALL LABOR, 14 MATERIALS, TRANSPORTATION, TOOLS, FLEES, AND PERMITS REQUIRED FOR INSTALLATION OF A COMPLETE AND OPERATING ELECTRICAL SYSTEM. DRAWINGS ARE DIAGRAMMATIC AND ARE NOT INTENDED TO SHOW EVERY DETAIL. 15 THIS PROJECT COMPLIES WITH THE APPLICABLE RULES OF THE 1996 NATIONAL ELECTRICAL CODE, NATIONAL FIRE CODES, TITLE 24 AND LOCAL ELECTRICAL CODES AS ADOPTED BY THE GOVERNING MUNICIPALITY. 16 CONDUCTORS SHALL BE INSTALLED IN CODE APPROVED RACEWAYS. IMG AND RMC MAY BE USED INDOORS AND OUTDOORS. EMT MAY BE USED IN INDOOR DRY LOCATIONS. TAPE WRAPPED IMG OR SCHEDULE 40 PVC (WITH CODE SIZED GROUND WIRE SHALL BE USED BELOW GRADE OR IN CONCRETE 17 SLAB. TRANSITION FROM BELOW GRADE PVC SHALL BE TAPE WRAPPED IMG OR RMC. THE COMPLETE ELECTRICAL SYSTEM SHALL BE GROUNDED IN ACCORDANCE WITH N.E.G. ARTICLE 250. 18 GROUND PATH THROUGHOUT RACEWAY SYSTEM SHALL BE CONTINUOUS. ALL SWITCHES SHALL BE RATED FOR 120V. -277V. AND RECEPTACLES SHALL BE NEMA 5-15R UNLESS 19 OTHERWISE NOTED. SPECIAL RECEPTACLES SHALL MATCH WITH EQUIPMENT AS SPECIFIED. ALL OPERATING MANUAL, BROCHURES, CATALOGS, ETC... SHALL BE TURNED OVER TO THE OWNER AT 20 JOB COMPLETION. ALL LIGHTING FIXTURES SHALL BE NEW AND INSTALLED WITH THE NECESSARY FITTING AND MOUNTING 21 ATTACHMENTS FOR COMPLETE INSTALLATION. ALL EXPOSED PARTS OF ELECTRICAL EQUIPMENT SHALL BE COMPLETELY, THOROUGHLY GLEANED AND FREE FROM GEMENT, PLASTER, PAINT, ETC... ALL SCRATCHES ARE TO BE REFINISHED IN AN ACCEPTABLE MANNER. 22 THE CONTRACTOR SUBMITS TO THE CITY ENGINEER 'AS BUILT' PRINTS BEFORE ACCEPTING THE INSTALLATION. PRINTS SHALL INDICATE, IN RED, ALL DEVIATIONS FROM THE CONTRACT PLANS, SUCH AS LOCATION OF POLES, PULL BOXES AND RUNS, DEPTH OF CONDUITS, NUMBER OF CONDUCTORS, AND OTHER APPURTENANT WORK. ELECTRICAL CONTRACTOR SHALL INSTALL ALL POWER, CONTROL WIRES, CONDUITS, AND OUTLETS FOR IRRIGATION EQUIPMENT. REFER TO IRRIGATION DRAWINGS FOR CONTROL SCHEMATICS. LIGHTING NOTES CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR THE CIRCUIT SCHEDULE, METER SERVICE PEDESTAL, AND A SINGLE LINE DIAGRAM. MONUMENT SIGN LIGHT SCHEDULE TO BE REGULATED BY PHOTO CELL ON ALL NIGHT. PALM TREE UPLIGHTS LIGHT SCHEDULE TO BE REGULATED BY TIMER SET 6PM - 12AM. PHOTO CELL 12OV. INTERMATIC 4K4321 DEVICE, MOUNT OUTSIDE ON BACKSIDE OF MONUMENT WALL. PROVIDE A TOGGLE SWITCH SPST 12OV. 15 AMPS. ( LABEL TEST 4 AUTO ) LIGHTING CONTRACTORS 20AMPS. RATED N.O. 120VAC. COIL SQUARE -D 48903-LG40. TIME SWITCH 120VAC. MOTOR DPST INTERMATIC # TIO3. I. All rights to be photo -cell activated with transformer located adjacent to building and close to irrigation controller to share I 10 power supply. 2. Light fixtures as indicated on these plans are approximate with final locations to be verified by Landscape Architect on site. 3. All low voltage tree uplighting shall be installed after planting of specimen trees. 4. Contractor shall verify quantities per plan. 5. Contractor shall install ground fault interrupters as required per local code. (In all cases where rights are to be installed within 10' of water) 6. All work shall be in accordance with local code and detailed specifications provided. Any work not meeting the approval of the owner or Landscape Architect shall be corrected at the contractor's expense with acceptable work. Contractor to supply proper lamp (Narrow or wide angle) to spotrights as specified. 8. All fixtures located at grade shall be installed with a rocket perma-post by hadco ( # 370-53A ) - BLACK. 9. The electrician is to provide all necessary plans, specifications and documents, etc. (If not provided by the owner's Electrical Engineer) and obtain all required approvals and permits. 10. Coordinate all work, especially sleeving, trenching and backfilling with irrigation, concrete and masonry subcontractors as required. 1I— ' I \--Ji1I_ UII—i I 11 VI—I ILJI \V I I II VI— CONTRACTOR TO RELIEVE POWER FROM ELECTRICAL PEDESTAL @ SUMMIT AVENUE HISTORIC PARK 600VA& CORNER OF SUMMIT AVE. & PINEHURST LANE SCALE 1" = 10' - Oil SUMMIT AVENUE - 600VA. OG II�Cf�II�N I IVIV I.VIV I rCVLLCI"C 120/240V., IPH., 3W 60 AMPS. MAIN CORNER OF SUMMIT AVE. & TURNBERRY WAY 0 UPLIGHT FIXTURE Nt.s. LIGHT FIXTURE 41$ TYP . CONCRETE F.G. i)NdV�A"' 13" Ilk 3" GRAVEL FOR DRAINAGE CONDUIT T _L I . .L \_/I\_/ \_/ \-/ III i \_/i \1 v_L_/II \i \ i vv I I I 600VA* - NOTE THE ELECTRICAL CONTRACTOR MUST HIDE THE LOW VOLTAGE 4 TRANSFORMER OUT OF VIEW AS MUCH AS POSSIBLE 4 " TYP . TOP VIEW MONUMENT UPLIGHT FIXTURE ,yrs. LIGHTING FIXTURE SCHEDULE SYMBOL DESCRIPTION MFG. &PART # LAMP AMPS MOUNTING QTY. DETAIL / SHEET (1) SOW. INCANDESCENT LOW B -K # (1) LS-9-BZP-7-9 OR G.E# 0.42 TREE 24 1 / L-19 VOLTAGE FIXTURE MOUNT ON HADCO # BLS16-A INCLUDED TRUNK E� TREE, WET LOCATION, 120V. MOUNTING AND TRANSFORMER (1) SOVA. (9) XMER HADCO # TSS663-13 STRAP B -K # TS-MB-2-BZP-MEASURE STRAP AT JOB SITE BFT. FLUORESCENT 2+2 LAMPS ORGATECH-OMEGALUX # PHILIPS # 09 GROUND 3 2 ! L-19 O UPLIGHT WET LOCATION, 120V. 12 -428T5 -I -S -G -120V-0-193 F28T5/830 DETAIL TEL: (818) 841-7896 SCALE 1" = 10' - 0" SHEET KEY N.T.S. DRAWN BYi SCALE, DESIGNED BY, 2 DATE, ELECTRICAL SPECIFICATIONS SEE SHEET L20 CHECKED BY, AP VED BYiDWG. NG., /aDATE D Q �r;"000r� • S tj"&- CITY ENGINEER R.C.E. X199'EXP. DATE 19/3119 zo/2 � ITIS cAPes Landscape Architecture and Planning 19762 MacArthur Blvd., Ste. 130 Irvine, CA. 92612 Richard Polhamus, License CA—#2782 (949) 644-9370 (949) 476-1432 FAX N0. 1 REVISION DWN CHK CB/HD/MM SS/RP DATE 9/6/00 ioB 00-019 L1 9 of 20