Loading...
HomeMy WebLinkAbout3097-1GENERAL NOTES: 1 ALL WORK SHOWN HEREON SHALL BE DONE IN ACCORDANCE WITH THE CITY OF FONTANA STANDARDS AND SPECIFICATIONS, CHAPTER 33 OF THE BUILDING CODE, 1997 EDITION, AND THE CONTRACT DOCUMENTS. 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE SOILS ENGINEER'S RECOMMENDATIONS AND CONTRACT SPECIFICATIONS. THE SOILS REPORT PREPARED BY RMA GROUP, 10851 EDISON COURT, RANCHO CUCAMONGA, CA 91730, (909) 969-1751, AND ANY AMENDMENTS THERETO, ARE HEREBY MADE A PART HEREOF. 3. PRIOR TO THE START OF GRADING, ALL EXISTING VEGETATION AND DEBRIS, INCLUDING EXISTING STRUCTURES, FOOTINGS, FOUNDATIONS, RUIBBLE, TREES, AND ROOT SYSTEMS, SHALL BE REMOVED FROM THE SITE TO THE SATISFACTION OF THE SOILS ENGINEER. 4. AFTER STRIPING EXISTING DEBRIS, ANY EXISTING LOOSE FILL OR DISTURBED NATURAL SOILS SHALL BE EXCAVATED TO THE SATISFACTION OF TOE SOILS ENGINEER. 5. THE EXPOSED SOILS SHALL THEN BE INSPECTED BY THE SOILS ENGINEER, AND ANY ADDITIONAL OVER—EXCAVATION SHALL THEN BE MADE IN ACCORDANCE WITH THE SOILS ENGINEER'S RECOMMENDATION AND AS CONTAINED IN THE SOILS REPORT 6. THE EXPOSED SOILS SHOULD THEN BE SCARIFIED TO A MINIMUM DEPTH OF 6 INCHES, BROUGHT TO PROPER MOISTURE CONTENT AND COMPACTED TO AT LEAST 90% OF THE MAXIMUM DENSITY OBTAINABLE BY THE A.S.T.M. 0-1557-70 METHOD OF COMPACTION TO ATTAIN A DENSE AND UNYIELDING CONDITION. 7. COMPACTION SHALL DE OBTAINED BY METHODS APPROVED BY THE SOILS ENGINEER. 8. IF ANY UNKNOWN SUBSURFACE STRUCTURES ARE ENCOUNTERED DURING CONSTRUCTION, THEY SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE SOILS ENGINEER PRIOR TO PROCEEDING. 9. DUST SHALL BE CONTROLLED BY WATERING THROUGHOUT THE GRADING AND BUILDING CONSTRUCTION OPERATIONS. 10. PROTECTIVE MEASURES SHALL BE TAKEN BY THE CONTRACTOR TO PROTECT ADJACENT PROPERTY AT ALL TIMES DURING CONSTRUCTION. PROTECTIVE MEASURES SHALL BE TAKEN BY THE CONTRACTOR SO AS NOT TO CAUSE ANY MUD, SILT OR DEBRIS ONTO PUBLIC OR ADJACENT PROPERTY. ANY MUD OR DEBRIS ON PUBLIC PROPERTY SHALL BE REMOVED IMMEDIATELY. 11. ALL GRADING AND FILLING OPERATIONS SHALL BE OBSERVED, INSPECTED AND TESTED BY A LICENSED SOILS ENGINEER APPROVED BY THE OWNER, AND COMPACTION REPORTS PROVIDED FOR CITY APPROVAL. 12. PRIOR TO THE START OF ANY BUILDING CONSTRUCTION, THE CONTRACTOR SHALL FURNISH THE ARCHITECT, OWNER AND THE CITY WITH THE CIVIL ENGINEER'S WRITTEN OPINION THAT APPROVED PLANS AND COMPACTION REPORTS FROM THE SOILS ENGINEER THAT THE PROPER COMPACTION AND PREPARATION HAS BEEN OBTAINED. 13. NO GRADING SHALL COMMENCE WITHOUT OBTAINING GRADING PERMIT AND NOTIFYING GRADING INSPECTOR 24 HOURS PRIOR TO THE START OF WORK. 14. PRIOR TO THE COMPLETION OF THIS CONTRACT, THE CONTRACTOR SHALL OBTAIN COMPACTION REPORTS FROM THE SOILS ENGINEER THAT THE PROPER SUBGRADE COMPACTION HAS BEEN OBTAINED) AND SHALL FURNISH SAID REPORTS TO THE OWNER FOR APPROVAL. 15. THE CONTRACTOR SHALL BE RESPONSIBLE TO REPORT DISCREPANCIES IN PLANS AND/OR FIELD CONDITIONS IMMEDIATELY TO THE DESIGN ENGINEER FOR RESOLUTIONS PRIOR TO CONSTRUCTION, AND SHALL BE RESPONSIBLE FOR DESCREPANCIES NO SO REPORTED AND RESOLVED. 16. ALL MANUFACTURED SLOPES ARE 2(H): 1(V) UNLESS OTHERWISE NOTED ON THE PLANS. NO SLOPES SHALL BE CONSTRUCTED STEEPER THAN 2(H): 1(V) . 17. SEE THE DIMENSION CONTROL PLAN FOR PRECISE HORIZONTAL CONTROL DATA. CURVE DATA, BEARINGS, DISTANCES. ETC. 18. PRIOR TO THE COMPLETION OF THIS CONTRACT, THE CONTRACTOR SHALL OBTAIN THE CIVIL ENGINEER'S WRITTEN OPINION THAT THE PROPER SUBGRADE ELEVATIONS HAVE BEEN OBTAINED AND SHALL FURNISH SAID WRITTEN OPINION TO THE OWNER FOR APPROVAL. 19. MINIMUM GRADES SHALL BE: (A) CONCRETE STRUCTURES, "V" GUTTERS. CURB AND GUTTER, ETC. = 0.50% (B) ASPHALT, TURF. GRADED SOIL. ETC. = 1.0% 20. CONTRACTOR SHALL IMPLEMENT SAND BAG EROSION CONTROL MEASURES AS NECESSARY TO PROTECT THE GRADING OPERATIONS AND ADJACENT PROPERTY. EROSION CONTROL MEASURES TO BE IMPLEMENTED IN ACCORDANCE WITH CHAPTER 33 OF THE U.B.C., 1997 EDITION. 21. ALL TRENCH BACKFILL TO BE CERTIFIED BY SOILS ENGINEER. 22. CITY OF FONTANA UTILITY NOTIFICATION LIST CITY OF FONTANA PACIFIC BELL CO. ATTN: CARLOS NAVARRO ATTN: VIRGINIA BECKER 8353 SIERRA AVENUE 3939 E.CORONADO STREET FONTANA, CA 92335 ANAHEIM, CA 92807 (909) 350-6632 (714) 666-5467 SO. CALIFORNIA GAS COMPANY COMCAST (CABLE TV) ATTN. GREG GASPAR ATTN: JACK HAYES 16231 VALLEY BLVD. 1205 DUPONT AVENUE FONTANA, CA. 92335 ONTARIO, CA. 91761 (909) 428-8411 (909) 390-4736 EMERGENCIES: (800) 427-2200 GENERAL TELEPHONE COMPANY SO. CALIFORNIA EDISON COMPANY ATTN: STEVE HOCK 7951 REDWOOD AVENUE 1400 E. PHILLIPS BLVD. FONTANA, CA. 92335 ONTARIO, CA. 91766 (909) (909) 820-5598 UNDERGROUND (800) 422-4133 (909) 675-5100 TRANSM 15SIONS (213) 637-1233 PIPELINES FONTANA WATER COMPANY (909) 357-6233 DISTRIBUTION ATTN: MICHAEL J. McGRAW (800) 422-4133 8440 NUEVO AVENUE FONTANA, CA 9.2335 CRAWFORD CANYON MUTUAL WATER CO. (909) 822-2201 ATTN: BILL VANDERKIEFT, JR. FAX: (909) 823=5045 (619) 868-6040 UNDERGROUND SERVICE ALERT (800) 422-4133 23. ALL GRADING SHALL CEASE DURING PERIODS OF WINDS IN EXCESS OF 25 MPH. SITE SHALL BE KEPT CONTINUOUSLY WATERED DURING PERIODS OF HIGH WINDS TO PREVENT AIRBORNE EROSION. NOTE: PER NPDES REQUIREMENTS A NOTICE OF INTENT (N.0.1.) IS REQUIRED FOR THIS DEVELOPEMENT. PRIVATE ENGINEER'S NOTICE TO CONTRACTORS: THE EXISTANCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS; TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS. THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. 0 INDEX MAP VICINITY MAP GRADED AREA -830,750 S.F. EARTHWORK OUANTITIES: CUTS 28,97r.99 C.Y. (RAW) FILL12,451 C.Y. (RAW) SIERRA LAKES SPECIFIC PLAN DWN CHK CB/HD/MM SS/RP DATE 1/14/02 X06 # 01-017 CE��l of 39 J :1826-11801g rad i nglrg 1.dwg, 01/16/2002 12:29:48 PM, of