Loading...
HomeMy WebLinkAboutNONAME_2896_012&A IIII kA A3W 3WV in 3/4, 1 -Uig' Underground Service Alert Call: TOLL FREE (� 1-800 422-4133 TWO WORKING DAYS BEFORE YOU DIG 3W 1-114" 3W 2" -r 1" 3N" � s 3/4" y4• 1• 3/4" 1" . �... 1/4" IRRIGATION NOTES 1 . THIS SYSTEM IS DIAGRAMMATIC. ALL PIPE, VALVES, ETC. SHOWN WITHIN PAVED AREAS ARE FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED IN PLANTING AREAS WHEREVER POSSIBLE. 2. DO NOT WILLFULLY INSTALL THE SPRINKLER SYSTEM AS INDICATED ON THE DRAWINGS WHEN IT IS OBVIOUS IN THE FIELD THAT UNKNOWN OBSTRUCTIONS OR GRADE DIFFERENCES EXIST AND SHOULD BE BROUGHT TO THE ATTENTION OF THE OWNER'S AUTHORIZED REPRESENTATIVE. IN THE EVENT THAT THIS NOTIFICATION IS NOT PERFORMED, THE CONTRACTOR MUST ASSUME FULL RESPONSIBILITY FOR REVISIONS NECESSARY. 3. SYSTEM DESIGN IS BASED ON MINIMUM OPERATING PRESSURE SHOWN AT EACH POINT OF CONNECTION WITH MAXIMUM GPM DEMAND SPECIFIED. IRRIGATION CONTRACTOR SHALL VERIFY ALL PRESSURES ON 317E PRIOR TO CONSTRUCTION TO OWNER'S CONSTRUCTION REPRESENTATIVE. 4. IT IS THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO FAMILIARIZE HIMSELF WITH ALL GRADE DIFFERENCES, LOCATION OF WALLS, RETAINING WALLS, CURBS, ETC. HE SHALL COORDINATE ALL HIS WORK WITH THE GENERAL CONTRACTOR AND OTHER SUB -CONTRACTORS FOR LOCATION OF PIPE SLEEVES THROUGH WALLS, UNDER ROADS, PAVING AND STRUCTURES. S. MAMlLMIE FEEDER BETWEEN POMtT OF CONNECTION, METER, AND BACKFLOW PREVENTER TO BE OF MATERIAL REQUIRED BY CURRENT WATER DISTRICT. 8. FINAL LOCATION OF THE AUTOMATIC CONTROLLER ENCLOSURE AND THE BACKFLOW PREVENTION DEVICE SHALL BE APPROVED BY THE CITY'S AND OWNER'S • REPRESENTATIVE, AND/OR LANDSCAPE ARCHITECT, WHERE APPLICABLE. 7. IN ADDITION TO THE SLEEVES SHOWN ON THE PLAN, THE IRRIGATION CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF ADDITIONAL SLEEVES OF SUFFICIENT SIZE UNDER ALL PAVED AREAS PRIOR TO PAVING UPON APPROVAL OF THE OWNER'S REPRESENTATIVE, IF REQUIRED TO OPERATE SYSTEMS. 8. MRiGATiON CONTRACTOR SHALL FLUSH ALL LINES AND ADJUST ALL HEADS FOR MAXIMUM PERFORMANCE AND TO PREVENT OVERSPRAY ONTO WALKS, STREETS, AND BUILDINGS AS MUCH AS POSSIBLE. THIS SHALL INCLUDE SELECTING THE BEST NOZZLE RADIUS TO FIT UNUSUAL SITE CONDITIONS FOR APPROVAL PURPOSES AT NO EXTRA CHARGE. CALL LANDSCAPE ARCHITECT 48 HOURS IN ADVANCE FOR ANY \ COVERAGE TESTS. 9. QUALITY CONTROL OBSERVATION SEQUENCES ARE FOUND IN THE SPECIFICATION& 10. CLEAN-UP ON A DAILY SASS PER OWNER'S REPRESENTATIVE'S APPROVAL. 31C 3W & 1" ` &4" T lot ft 3W 3/4" • \ 3/4" aft��. ` \ 3/4" E" SLEEVE / ♦ - is 3W 4" SLEEVE % \� % \ �•` EQUIPMENT �M PROPOSED W. NIBCO T-113 C66Q MY -INV -2.00 AFPFKMM Or SUPERIOR 9%DW ® ROATP4X DATA IR220S-1.5 ® SUPERIOR 3100 SERIES O RAINM 33D133DK E TOR{ ` 3/4 ® CAMBELL SCIENTIFIC INC. TE 525 - - - APPROVED SCH 40 PVC UCO APPROVED CL. 200 PVC IRRIGATION LEGEND SCH. 40 PVC == APPROVED SCH. 40 PVC U SYS. MANUFACTURER MnnFl NIIMRFR DESO pTION BA= G.PAL Pa31 \ C-16 �J O Q U E \ ♦ 1%2 EL TORO 5702 -12P -COM -50 POP-UP SPRAY HEAD 5 30 % LL O .10 '0- TORO7 -1 5 OZ 2P -COM -ST POP-UP SPRAY HEAD 5 .14 30 \ � O TORO 5702 -12P -COM -5H POP-UP SPRAY HEAD 5 .20 30 TORO 570Z -12P -COM -5F POP-UP SPRAY HEAD 5 .40 30 % 11 TORO 5702-12P-COM-I5-ADJ POP-UP SPRAY HEAD T .40 30 TORO 5702 -12P -COM -80 POP-UP SPRAY HEAD r .20 30 ` ♦ , TORO 570Z -12P -COM -8T POP-UP SPRAY HEAD 8' .30 30 • TORO 570Z -12P -COM -8H POP-UP SPRAY HEAD 0' .50 30 )IK TORO 570Z -12P -COM -BF POP-UP SPRAY HEAD N 1.00 30 IV TORO 570Z-12P-COM-15-ADJ POP-UP SPRAY HEAD Ir .70 30 W TORO 570Z -12P -COM -10Q POP-UP SPRAY HEAD 10' .40 30 V TORO 5702-12P-COM-IOT POP-UP SPRAY HEAD 1W .50 30 V TORO 570Z -12P -COM -10H POP-UP SPRAY HEAD 10' .70 30 + TORO 5742-12P-COM-IOFF POP-UP SPRAY HEAD 10' 1.500 30 + TORO 570Z-12P-COM-I5-ADJ POP-UP SPRAY HEAD 10' .80 30 TORO 5702 -12P -COM -120 POP-UP SPRAY HEAD 12' .50 30 TORO 570Z -12P -COM -12T POP-UP SPRAY HEAD 12' .70 30 O TORO 5702 -12P -COM -12N POP-UP SPRAY HEAD 12' 1.10 30 O TORO 57OZ-12P-COM-12F POP-UP SPRAY HEAD 12' 2.20 30 �► TORO 570Z-12P-COM-I5-ADJ POP-UP SPRAY HEAD 12' .70 30 t TORO 570Z -12P -COM -150 POP-UP SPRAY HEAD 15 .90 30 TORO 570Z -12P -COM -15T POP-UP SPRAY HEAD 15' 1.10 30 TORO 570Z -12P -COM -15H POP-UP SPRAY HEAD is 1.70 30 m TORO 570Z -12P -COM -15F POP-UP SPRAY HEAD 15' 3.60 30 TORO 570Z-12P-COM-15-ADJ POP-UP SPRAY HEAD is .90 30 12 TORO 570Z-12P-COM-4EST POP-UP SPRAY HEAD 4X15' .80 30 E3 TORO 5702-i2P-001-4UT POP-UP SPRAY HEAD 4X3W 1.20 30 EQUIPMENT �M PROPOSED W. NIBCO T-113 FE800 MY -INV -2.00 AFPFKMM Or SUPERIOR 9%DW ® ROATP4X DATA IR220S-1.5 ® SUPERIOR 3100 SERIES O RAINM 33D133DK E TOR{ 8000 ® CAMBELL SCIENTIFIC INC. TE 525 - - - APPROVED SCH 40 PVC UCO APPROVED CL. 200 PVC APPROVED SCH. 40 PVC == APPROVED SCH. 40 PVC •MODEL #CTPN-8STF0NTrCTI-ALFONT, SUPKIEo BY CALIFORNIA TURF PRODUCTS, SAN DIEGO, CALIFQRIK (619) 793-3999 VALVE SIZING KEY VALVE # 1 100_GPM W4" VANE SIZE DOM TIC WATER METER BY OTHEM, SIZE AS SHOWN - DEVEtOPEA TO PAY FOR ALL NECESSARY FEES AND PERMITS LINE -SIZE GATE VALVE REDUCED PRESSURE BACKR.OW DEVICE, SIZE AS SHOWN BRASS ELECTRIC REMOTE CONTROL VALVE, SIZE AS SHOWN FLOW METER WOO TRATTER NORMALLY OPEN ELECTRIC GLOBE VALVE QUICK COUPLING VALVE (SUPPLY (4) KEYS TOTAL) NETWORK X00 AUTOMATIC CONTROLLER TIPPING BUCKET RAIN GAUGE ( HEAVY DUTY MODEL) MAINLINE, SIZE AS SHOWN, MIN. COVER 11r; USE CL 315 PVC FOR 2" AND LARGER. LATERAL UNE, SIZE AS SHOWN, 17 MMI. COVER SLEEVES, SIZED 2X LARGER THAN PIPE TO BE INSERTED, MIN. COVER AS REQUIRED. FOR STREET CROSSINGS, USE 6" SLEEVE. 4" WIRE SLEEVES, MIN. COVER AS REQUIRED. CONTRACTOR TO INSTALL PCD SCREENS WHEREVER REQUIRED TO ADJUST THE RADIUS TO PROVIDE 100% COVERAGE TO REDUCE OVERTHROW ONTO WALKS AS MUCH AS POSSIBLE SEE DETAIL ALL EXTRA CONTROL PILOT WIRE S TO BE ROUTED FROM EACH CONTROLLER AND LOOPED UP INTO EACH VALVE BOX (24" COIL) TO THE TERMINAL END. THE EXTRA WIRES SHALL BE IDENTIFIED AS EXTRA AND NUMBERED WITH TAGS AT EACH VALVE BOX AND AT ALL CONTROLLERS. PLAN CROSS REFERENCES FOR NOTES AND LEGENDS, SEE SHEET I -3A FOR DETAILS, SEE SHEET 1-4, 1-5 FOR SPECIFICATIONS, SEE SPECIFICATION BOOKLET FOR CORRESPONDING CONSTRUCTION PLAN SEE SHEET C -3A FOR CORRESPONDING PLANTING PLAN SEE SHEET P -3A i • ♦ t � 4" SLEEVE 6" SLEEVE \ It • CONNECT TO POINT OF CONNECTION "C" \ BEECH SOUTH OF SUMMIT AVE. (SEE SHEE1 I.3) 7 e-1 a -e -e ., oRAMr: LML SUMMIT HEIGHTS TRACT #15839,15840 COMMUMTY FACILITIES DISTRICT W. L° L 03/24/2000 CHBO a® ear: AFPFKMM Or DIM NO.: U)5 OLO JAFDATE. E 126 EXP. DATE 12,01M cid e E w 00 0 1I!JNil III!!J!1l LAN D S CAP E ARCH ITECTU�RE SITE PLANNING 10630 Town Center Dr., Suite 128 Rancho Cucamonga, CA 91730 (909) 484-2800 Fax (909) 484-2802 • Richard Krumwiede CA Lic. 02034 AZ Lac. #29191 15 W Lia. # 446 TX. Llc. #1984 0SCAAt y�0 �umw�� � a a� n :33 a 4. -♦ .r � c L ly i U)5 OLO E cid e E w M W OM ad c .I� UCO LO � T� td Y � U c U CIO (D �J O Q U E O C O CL LL O U REVISIONS A DRAWN BY LML DATE 000 1" = 30' 95007-3 SHEET NUMBER AI I -3A I 10F I qSHTS.