Loading...
HomeMy WebLinkAbout2768-2CONDUCTOR TABLE STANDARD MASTARMS LUMINAIRE PED PUSH BT. SIGNAL MOUNTING S.N.S. TYPE HT. SIG. LU M. H.P.S.V. TYPE m�FA1FNI�1FNIVA'�1�1��1�1 QUAD VEHICLE PED. MESSAGE 26A-3-80 35' 45' 15 250W B 6 EAST MAS,MAS,SV-1—T SP-1—CS Beech Ave. 1—A 10 — — — B 8 SOUTH TV -1—T SP-1—CS — 26-4-80 30' 45' 15 250W B 8 SOUTH MAS,MAS,SV-1—T SP-1—CS So. Highland Ave. 1—A Tor- — — — B 2 WEST TV -1—T SP-1—CS — 26A-4-80 35 45' 15' 250W B 2 WEST MAS,MAS,SV-1—T SP-1—CS Beech Ave. 1—A 10' — — — B 4 NORTH TV -1—T SP-1—CS — 26-4-80 30 45' 15' 250W B 4 NORTH MAS,MAS,SV-1—T SP-1—CS So. Highland Ave. 1—A 10 — — — B 6 EAST TV -1—T I SP-1—CS — LOCATIONS PRIOR TO FINAL PLACEMENT. 3: � 57'---f- I I 52 i� '0' i II 6. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CIN OF � � � FONTANA ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF WORK. �� i ii Q � � � ii ii � (� � � � i� i to 7. WHERE SIGNAL CONDUIT STREET CROSSINGS ARE NOT TO BE INSTALLED USING A � CD� m Di BORING METHOD, STREET SHALL BE REPAIRED PER DETAIL THIS SHEET AND THE WM SPECIAL PROVISIONS, SECTION E.W Z � �i ii � I I I I � � ° � 0 . �� �� �� � � ��� � Iz SCALE: 1 =20 8. EXISTING STREET LIGHTING SHALL REMAIN IN OPERATION UNTIL NEW LIGHTING M W F—I zor ' wil LiW, � I CI LL_ Z oil Z MAST -ARM � � X L j�l MAST -ARM MOUNTING I �I CLAMP FOR �I MODEL 711 OPTICAL DETECTOR �I i 1 10 ILUMINAIRE 1 2 1 2 1 2 1 2 1 2 1 1 1 2 1 2 1 2 � w I OPTICOM CABLE 1 1 1 1 1 2 1 2 1 2 1 2 1 2 1 1 1 1 1/ CONDUIT SIZE 3" 1 3" 1 3" 1 4" 1 4" 4" 1 4" 1 4" 1 3" 13 / 10 SOUTH TELEPHONE PEDESTAL / @/,3 (TELEPHONE SERVICE POINT) / 1� — EXISTING RIGHT OF WAY _ — g ,, - I- _/ -- I --————— — — — — —— EXISTING BUSBAY— _�-- 17"v - - - - - - - - -17, W - - - 7__T1 i I xK—RAIL LO < x I it � II N I I I ~I - - - _ - - - - - - 4"G PLASTIC - - - - - - _ - - - - - 4"G PLASTIC - - - - - 4"G PLASTIC _ - - - - - - - -I - - - - - - - - - - - - _ _ _ _ W EXISTING CURB AND GUTTER— ____________- j ----------___—__�--;�� EXISTING RIGHT OF WAY TRAFFIC SIGNAL GENERAL NOTES: \ (D\\ EDISON HANDHOLE 1. TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA� t CABLE PEDESTAL STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 1992) \POLE # 4282557E 6 7 I (1(`ATIlI�.I OP DI I I I�If1�R(.Rlll I�If1 FAf II ITIFC ARF APPR(IYIAAATF TNF (`f1�ITRIl(`T(1R I� IQ 0 I� I� z W I I POLE # 4282552E \ SCE HANDHOLE (ELECTRIC SERVICE POINT \-1 ti L 0 C NEW A.C. POLE SCHEDULE STANDARD MASTARMS LUMINAIRE PED PUSH BT. SIGNAL MOUNTING S.N.S. TYPE HT. SIG. LU M. H.P.S.V. TYPE PHASE QUAD VEHICLE PED. MESSAGE 26A-3-80 35' 45' 15 250W B 6 EAST MAS,MAS,SV-1—T SP-1—CS Beech Ave. 1—A 10 — — — B 8 SOUTH TV -1—T SP-1—CS — 26-4-80 30' 45' 15 250W B 8 SOUTH MAS,MAS,SV-1—T SP-1—CS So. Highland Ave. 1—A Tor- — — — B 2 WEST TV -1—T SP-1—CS — 26A-4-80 35 45' 15' 250W B 2 WEST MAS,MAS,SV-1—T SP-1—CS Beech Ave. 1—A 10' — — — B 4 NORTH TV -1—T SP-1—CS — 26-4-80 30 45' 15' 250W B 4 NORTH MAS,MAS,SV-1—T SP-1—CS So. Highland Ave. 1—A 10 — — — B 6 EAST TV -1—T I SP-1—CS — 1' 1' EXISTING 0.10' MIN. AC SUREACWv TACK COAT ALL EDGES �— 2—SACK SLURRY BACKFILL (INITIAL POUR TO BE FLUSH WITH SURROUNDING SURFACE) RIGID METAL CORiDUIT (INSTALLED HATH 18" A11PI. COVER) TRENCH REPAIR DETAIL N.T.S. AVENUE 2" C, 2 #10 (LUMINAIRES) .0 - - 17"w W.V. / /+ 7 6 1 � 5 � � I 101 W/ / 7 2" C, 2 #6,1#8 (SERVICE,GFCI) o 03 /Q \\\\ 3 4 04 0iI i° K -RAILS a i c� o 4"G PLASTIC I \ \ \ 4"G PLASTIC 4"G PLA TIC�T-r 4"G PLASTIC - 4"G PLASTIC 3 9 -1 24" RCP --4 — —_T __r --—————— ————— — — — — —— ———————————————— 3 06 06 3 01 C— — — — —04 _ _ EXISTING BUSBAY �1--�-_-__-----=============_== - --------------------- 2 / 5 6 POLE # 4282555E _ _ ' ! EXISTING RIGHT OF WAY -- I� - - - 3 / TRAFFIC SIGNAL CONSTRUCTION NOTES: II � Ili I � �'� 1 FH 2 II II I I I I , W. V. Ij III II II —I�� � I �IIt I I II II I I u � ►t / II I I�NI I I I I / III I I II tl I`� I � ►i I EXISTING RIGHT OF WAY _EXISTING CURB AND GUTTER_ _ Curb/Berm flow lin or edge of should( BCR PLACEMENT A B I �� I j 13.8' 4' 13.7' 4' 13.3' 4' 13.0' 4' 13.5' 4' 13.9' 4' 12.2' 4' mm PHASE DIAGRAM \ I �� I j y PHASE 1 PHASE 2 PHASE 3 PHASE 4 ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS. ♦ PHASE 5 PHASE 6 HA HA • SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS \ I �� I j I II 11 � I I � � �I N i ii i � i / ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS. ♦ � � �� i� I I I PHONE UNDERGROUND SERVICE ALERT AT (800)227-2600, TWO (2)WORKING DAYS � I I BEFORE DIGGING. 3. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID METAL UNLESS SHOWN OTHERWISE. ALL VEHICLE HEADS SHALL BE PER SPECIAL PROVISIONS. 4. CONTRACTOR SHALL COORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING 0 WITH THE SOUTHERN CALIFORNIA EDISON COMPANY WELL IN ADVANCE OF NEED. 5. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT I I � LOCATIONS PRIOR TO FINAL PLACEMENT. 3: � 57'---f- I I 52 i� '0' i II 6. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CIN OF � � � FONTANA ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF WORK. �� i ii Q � � � ii ii � (� � � � i� i to 7. WHERE SIGNAL CONDUIT STREET CROSSINGS ARE NOT TO BE INSTALLED USING A � CD� m Di BORING METHOD, STREET SHALL BE REPAIRED PER DETAIL THIS SHEET AND THE WM SPECIAL PROVISIONS, SECTION E.W Z � �i ii � I I I I � � ° � 0 . �� �� �� � � ��� � Iz SCALE: 1 =20 8. EXISTING STREET LIGHTING SHALL REMAIN IN OPERATION UNTIL NEW LIGHTING M W NI x � ° � i ° ° I I � ° � 1Iu~i IS OPERATIONAL PER SPECIFICATIONS. w x 20 10 0 20 40 60 9. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS.`w MODIFY SPRINKLER SYSTEMS IF NECESSARY. o AAAA DIAL TvoM WORKING BEFORE DAYS BEFORE YOU DIG YOU DIG TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY SERVICE ALERT REMARKS 01 INSTALL TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING TYPE "P" CABINET, AUTOSCOPE DETECTION, AND APPURTENANT EQUIPMENT (SEE SPECIAL PROVISIONS). CONTROLLER CABINET AND FOUNDATION TO BE INSTALLED PER CITY STANDARD DRAWING 134. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECTRONIC EQUIPMENT REQUIRED TO PROVIDE THE DESIRED SIGNAL OPERATION AS SHOWN ON THE PLAN. 0 INSTALL TYPE III—BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND SOUTHERN CALIFORNIA EDISON COMPANY REQUIREMENTS (SEE SPECIAL PROVISIONS). INSTALL UNI—DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR, (MODEL 711 OR EQUAL), PER DETAIL THIS SHEET AND AS DIRECTED BY THE ENGINEER (SEE SPECIAL PROVISIONS). Q INSTALL IMAGE SENSOR UNIT PER CITY STANDARD DRAWING 133 AND AS DIRECTED BY THE ENGINEER (SEE SPECIAL PROVISIONS). Q5 FURNISH AND INSTALL 3" PVC CONDUIT WITH 2#2, 2#4 CONDUCTORS PER SCE REQUIREMENTS. © EXISTING MARBLELITE TO BE REMOVED (BY SOUTHERN CALIFORNIA EDISON). Q7 CONSTRUCT P.C.C. PAD AS SHOWN. RELOCATE SPRINKLER SYSTEM AS NECESSARY. F8_1 RELOCATE EXISTING K—RAIL BARRIER TWENTY FEET WESTERLY AS DIRECTED BY THE ENGINEER. Efl FURNISH AND INSTALL R73-3 SIGN AND HARDWARE PER CALTRANS DETAIL "U", ES -6T (QTY - 4). 10 FURNISH AND INSTALL 2" CONDUIT AND PULLROPE FOR COMMUNICATION CONDUCTORS PER PACIFIC BELL REQUIREMENTS. MMSN MMVTICN DATE MW aTY DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WffHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGMER MAY REQUIRE REVMONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. W n Z W Q 0 Z I -- O 0 Z Q W Z W Q V W W m SERVICE ADDRESS: 15316 SOUTH HIGHLAND AVENUE AUTOCAD FILENAME; SHIGH3EECH SG.DWG QC ESS/ pN9l CITY OF FONTANA, CALIFORNIA ��� CLYDEELWYN �y� TRAFFIC SIGNAL AND LIGHTING PLAN SWEET, JR. LAJ�' D1A1NM W.BEECH AVENUE scKE - _ No. 26690 ERIC LEWIS AND 1 20 EXp. 3-31-00 ERIC LEWIS SOUTH HIGHLAND -AVENUE o 9/9/99 civ slgj£ o���� opal.: Q/�3l �: 4 . DRAIIIIMG Na OF Cho CLYDE E. SWEET.R.C.F.. R.C.26690 • HTC 2 CITY ENGINES R.C.E. 2512 DATE: 276 8 2