Loading...
HomeMy WebLinkAbout2716-22CS 0- r - C" r`rn vs v v N 03 W I N N n / 4i 16 ELECTRICAL UCTION 16000 PART I- GENE 1.01 DESCRIPTION A. Related Requirements: Review the General Conditions, Standard Specifications and Special Provisions which contain information and requirements that apply to this Section. B. Work Included: Provide all electrical work for a complete and operable system as shown on the drawings and as specified in this section including, but not limited to the following: 1. Site investigations prior to bidding to establish existing conditions. 2. Temporary power and lighting facilities for construction. 3. Electrical underground service at 120/240 volt, single phase, three (3) wire services. 4. Service metering and distribution system for lighting power connections to one hundred -twenty (120) volt irrigation controller. 5. Lighting fixtures, mounting hardware, poles, foundations and pull boxes. 6. Provide wire, pull boxes and conduit extensions as required. 7. Adjustment and test of the electrical work. 8. Guarantee. C. Related Work in other Sections: Irrigation - Section 02810 (1.10 Connections To Utilities) Concrete - Section 201 & 303. 1.02 QUALITY ASSURANCE A. All products and equipment herein specified or indicated on the drawings shall be new with UL label and in accordance with the National Electrical Code, state and local codes. B. Applicable Standards: 1. General Conditions, Special Provisions, Exhibit "A" and Appendix 1. 1.03 SITE VISITATIONS A. Prior to the submission of the bid, the contractor shall visit the site and make a thorough examination of the existing conditions and thereby include allowances for this work in this bid. 1.04 PERMITS AND LICENSES A. Contractor shall pay for and obtain all necessary permits, inspections, insurance and licenses required for the Electrical work. 1.05 COORDINATION A. Contractor to coordinate the electrical work with other trades. Review drawings and specifications of all equipment requiring electrical connections prior to installation of the electrical system. Verify space, ventilation and clearances required to install electrical equipment. 1.06 SUBMITTALS A. Product data sheets for meter pedestal, meter, panelboard, lighting fixtures poles, wiring devices, and material list. Make all submittals at one time in booklet form. B. Record Drawings: 1. Installation Record: During the course of installation, carefully show in red line on a print of the electrical system drawings all changes made to the electrical system during installation. 2. Dimension Standards: Dimension from easily identifiable permanent features (buildings, monuments, sidewalks, pavements, etc.) points of connection, wiring routing, conduit locations, all stub -up locations and other related equipment as directed by the Agency's Authorized Representative. 3. Deliverables: Upon completion of the electrical system installation, submit two (2) sets of redlined record data prints to the Agency's Authorized Representative for approval prior to transferring information onto the signed original mylar. 4. Submittal of Record Set: Upon completion of the electrical system installation, and as a condition of its acceptance, deliver to the Agency's Authorized Representative, in Record Drawings referred to above. The delivery of the Record Drawings shall not relieve the Contractor of the Responsibility of furnishing required information that may have been omitted. 1.07 SUBSTITUTIONS A. Where manufacturer's name and catalog number are called out, the phase "or approved equal,, can be assumed except the burden of providing equality is on the bidder. 1.08 GUARANTEE A. All electrical work and equipment shall be guaranteed for one year from the date of acceptance on contractor's letterhead and turned over to the Agency at the completion and final acceptance of the job. PART 2,- PRODUCTS 2.01 UNDERGROUND SERVICE PEDESTAL A. Meter pedestal "MP" shall be NEMA 3R 120/240 volt, single phase, three (3) wire with one hundred (100) amp., two -pole main circuit breaker rated forty-two thousand (42,000) AIC. The service shall be a free-standing pre -wired pedestal assembly. Pedestal shall have underground pull section meter (without test blocks) and main disconnect. Pedestal shall comply with the requirements of the serving utility. Install black on white micarta nameplates on all sections, switches and spaces. Provide rodent screens. Pedestal shall be Meyars or approved equal, model numbers are indicated on the drawings. Bolt to concrete pad. 2.02 SWITCHES A. Switches shall be quick -make, quick -break type QMB rated six hundred (600) volts with frame size, number of poles and fuses as shown. 2.03 CIRCUIT BREAKERS Circuit breakers shall be bolt -on molded case type with thermal magnetic strips. Provide with rated voltage, frame size, number of poles and trip setting as shown. NEMA interrupting capacity shall be 42,000 AIC at 120/240 volts unless otherwise noted on plans. 2.04 PANELBOARDS A. Panelboards shall be surface mounted in pedestal, with Bolt- on circuit breakers type NQOB, with hinged lockable doors and typewritten directories. All multi -pole breakers shall be single handle common type. Use "SWD" circuit breakers for lighting circuits controlled from panels. Manufacturer shall be G.E., Square D, Westinghouse or Challenger. 2.05 WIRE A. Conduit shall be six hundred (600) volt insulation type THWN/THHN copper. 2.06 CONDUIT A. Conduit shall be rigid steel galvanized for exposed or in damp locations. Conduit underground shall be PVC schedule 40 with ground wire, minimum twenty-four (24) inches below grade unless noted otherwise. 2.07 CONDUCTORS A. Conductors shall be six hundred (600) volt insulation, type THHN/THWN copper. 2.08 SPLICES A. Splices on conductors #8 or smaller shall be Skotchloc spring connectors and for larger size cables use solderless connectors. B. Splices below grade shall be epoxy encapsulated "3M" or approved equal. 2.09 AREA LIGHTING A. Lighting fixtures shall be two hundred fifty (250) watt, high pressure sodium, with acord laxan diffuser; manufactured by Western Lighting Standards (Fixture Catalogue No.: FXB130) or approved equal. Paint color: black B. Poles shall be sixteen (16) feet high, four (4) inch diameter steel pole, manufactured by Western Lighting Standards (Pole Catalogue No.: RSS-416 BC) or approved equal. Paint color: black C. Refer to drawing for concrete pole base. PART 3 - EXECUTION A. Obstructions: The contractor's attention is directed to the existence of pipe and other underground improvements which may or may not be shown on plans. All reasonable precautions shall be taken to preserve and protect any such improvements whether shown improvements in order to prosecute the work, they shall be removed, maintained in operation, and permanently replaced by the contractor at his expense. B. Trenching: Trenches shall be excavated to the lines and grades established by the engineer. Bottom of trenches graded and prepared to provide a firm and uniform bearing throughout the entire length of conduit runs. 1. Trench Bottoms: Made more stable by wetting and tramping where fills are required and brought to a uniform grade. 2. Minimum Trench Depth: Sufficient to provide a minimum cover twenty-four (24) inches above topmost portions of conduits. 3.02 CONDUIT AND WIRING A. All conduit and wiring shall be installed underground in accordance with applicable regulations and the electrical drawings. Conduit runs are shown diagrammatically. Exact routing and location of the equipment to be determined in the field by the Agency's representative. Provide one thousand two hundred (1,200) lb. test pull cord in each empty conduit and cap both ends. 3.03 EXTERIOR EQUIPMENT A. All equipment and wiring to be weatherproof, including rodent screens. 3.04 GROUNDING A. All metallic conduits, supports and enclosures shall be grounded in compliance with the National Electrical Code. 3.05 ELECTRICAL SERVICE FACILITIES A. Electrical service and metering facilities shall be installed in compliance with all requirements of the Southern California Edison Company. 3.06 TESTING A. All new circuits shall be tested for short and open circuit to ground with a megger; resistance to ground shall be in compliance with the requirements of the National Electrical code. B. All lighting fixtures with adjustable aiming shall be verified at night in the presence of the Agency's Authorized Representative to comply with the manufacturer's aiming diagram to the satisfaction of the Agency's Authorized Representative. ***END OF SECTION*** SOCCER FIELD 1 SMALL 0 PD1 SOFTBALL FIELD a PD4 BASKETBALL COURTS 1 0 PD4 SOCCER FIELD 2 LARGE a PD2 TENNIS COURTS 1 0 PD5 BASKETBALL COURTS 2 0 PD5 BASEBALL FIELD a PD3 TENNIS COURTS 2 0 P06 EXTENDED OCCUPANCY OVERRIDE 0 PD6 SWITCH STATION ELEVATION. MOUNTED ON PANEL DOOR NOTE: 1. LIGHTING CONTROL PANEL PL400 AS MANUFACTURED BY TOMSTAR CONTROLS INC., BRENTWOOD, CA (510)634-5500 2. LOADS CONTROLLED BY SWITCHES PD1-PD6 SHALL BE STAGGERED ON IN 1 SECOND INTERVALS. LOW VOLTAGE EXTERIOR PHOTOCELL 4#18 TYPICAL OF 2 OUTPUTS ARP C-1� GAZEBO / FLAGPOLE / SIGNS C-13 SNACK BAR LIGHTS LOW VOLTAGE SWITCH �-- 318 TENNIS COURTS 1 LIGHTS � 3�t4 LIGHTING CONTROL PANEL LCP *AUTO ZONE LOW VOLTAGE SWITCH DESCRIPTION / NOTES C-597,9,11,13,15,21,23925,2733,35,4,6,8,10 32t34 480 MOUNTED REMOTELY 1 LVSC-1 TENNIS COURTS 2x LIGHTS C-17,19, 29, 31, 33,35912A,14A9121B914B,16, 1 8,20 22 36 38,40,42 314 PD2 1 LOW VOLTAGE SWITCH SOCCER FIELD 2 (LARGE) C-1,3,5,7,9,1 1,13915,17,19,21923,25927, 29 31 4 6 480 MOUNTED REMOTELY 1 LVSC-1 BASKETBALL COURTS 1� OVERRRIDE C-12,14,16,18,20,22,24,26,28,30, 32 34 36 38 40 42 29 31 33 35 3#14 PD4 1 LOW VOLTAGE SWITCH SOFTBALL FIELD A-12,14 480 MOUNTED REMOTELY 1 LVSC-1 BASKETBALL COURTS 2 LIGHTS A-16,18 314 PD6 1 LOW VOLTAGE SWITCH TENNIS COURTS 2 A-496 480 MOUNTED REMOTELY 1 LVSC-1 CONTACTOR CONTROL PANEL CCP NOTE: 1. EXTENDED OCCUPANCY OVERRIDE PROVIDES FOR SWITCHES THE ABILITY TO EXTEND NORMAL HOURS MOUNTED ON OF OPERATION FOR LIGHTING. PANEL DOOR SEE ELEVATION DETAIL THIS SHEET BREAKER PANEL LIGHTING CONTROLS WIRING DIAGRAM + EQUIPMENT ELEVATION NO SCALE CONTROL PANEL - LCP LOCATIONS: SNACK BAR BUILDING PANEL TYPE: MAIN CONTROL VOLTAGE: 120V MOUNTING: SURFACE CONTROL CIRCUIT: C-17 NEMA TYPE: 1 CIRCUIT # *VOLTS SW/ZONE LABEL *AUTO ZONE CONTROL TYPE DESCRIPTION / NOTES C-597,9,11,13,15,21,23925,2733,35,4,6,8,10 32t34 480 PD1 1 LVSC-1 SOCCER FIELD 1 (SMALL) C-17,19, 29, 31, 33,35912A,14A9121B914B,16, 1 8,20 22 36 38,40,42 480 PD2 1 LVSC-1 SOCCER FIELD 2 (LARGE) C-1,3,5,7,9,1 1,13915,17,19,21923,25927, 29 31 4 6 480 PD3 1 LVSC-1 BASEBALL FIELD C-12,14,16,18,20,22,24,26,28,30, 32 34 36 38 40 42 29 31 33 35 480 PD4 1 LVSC-1 SOFTBALL FIELD A-12,14 480 PD5 1 LVSC-1 TENNIS COURTS 1 A-16,18 480 PD6 1 LVSC-1 TENNIS COURTS 2 A-496 480 PD5 1 LVSC-1 BASKETBALL COURTS 1 A-8,10 480 PD6 1 LVSC -1 BASKETBALL COURTS 2 C-1,3,5,7 480 --- 1 LVSC-1 EXTERIOR / PARKING LIGHTS * REFER TO PANEL AUTOMATIC LIGHTING CONTROL ZONES ** PD =IN PANEL DOOR *** EACH 480V CIRCUIT TO BE COUNTED AS 2 POLES ON A 4 POLE CONTACTOR. AUTOMATIC CONTROL SCHEDULE ZONE ZONE DESCRIPTION TIME CHANNEL OPERATIONS NOTES 1 BALL FIELDS, SNACK BAR dt GAZEBO LIGHTS 1 MANUAL ON AFTER HOURS SHUT-OFF EVERY TWO HOURS 2 SPARE 2 3 EXTERIOR / PARKING LIGHTS -- PHOTOCELL ON / PHOTOCELL OFF V R a Z O LL LL O H V o� wQ' �a W UJ co a X W A U) N W U W W Z 0 Z W m � W U DATE SuamInA' 2-1-91 Z.-ZA REv1Ew r-r7T-, Mo - TEL DAIS 2-25-91 e0AW NONE .ion "M 1122 4e