HomeMy WebLinkAbout2703-6CITY OF FONTANA GENERAL NOTES
FOR DETOURS AROUND WORK ZONES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS AND THE
STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
(GREEN BOOK).
2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF
FONTANA ENGINEERING DIVISION PRIOR TO START OF ANY WORK
WITHIN THE CITY LIMITS. ALL INSPECTIONS SHALL BE REQUESTED AT
LEAST 24 HOURS PRIOR TO THE START OF ANY WORK. CALL (909) 350-
6632.
3. ALL MATERIALS AND EQUIPMENT SHALL CONFORM TO THE
REQUIREMENTS OF THE 1997 STANDARD SPECIFICATIONS FOR
PUBLIC WORKS CONSTRUCTION, "GREEN BOOK", AND THE 1998
SUPPLEMENT; THE STATE OF CALIFORNIA DEPARTMENT OF
TRANSPORTATION (CALTRANS) STANDARD PLANS AND STANDARD
SPECIFICATIONS, DATED 1992; CALTRANS TRAFFIC MANUAL, OR
LATEST NON -METRIC EDITION.
4. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL
POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE CALTRANS
TRAFFIC CONTROL MANUAL, CHAPTER 5 - MANUAL OF TRAFFIC
CONTROLS FOR CONSTRUCTION AND MAINTENANCE WORK ZONES,
LATEST EDITION, OR LATEST NON -METRIC EDITION, AND THE
W.A.T.C.H. (WORK AREA TRAFFIC CONTROL HANDBOOK), LATEST
EDITION.
5. THE CONTRACTOR SHALL REFER TO THE CITY ENGINEER IN THE EVENT
OF A CONFLICT OR POTENTIAL CONFLICT WITH THE PLANS AND/OR
SPECIFICATIONS FOR THIS PROJECT.
6. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL
RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE
SHALL BE MAINTAINED AT ALL TIMES IN THE CLOSURE AREA FOR
RESIDENTS AND EMERGENCY VEHICLES.
7. QUALIFIED FLAGGERS SHALL BE USED WHERE CONSTRUCTION
REDUCES THE ROADWAY TO A SINGLE LANE OR WHERE TRAFFIC MUST
STOP FOR MOVEMENT OF EQUIPMENT.
8. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE
ALL SIGNING, STRIPING} BARRICADES, AND OTHER TRAFFIC CONTROL
DEVICES TO THEIR ORIGINAL CONDITION, OR TO THE SATISFACTION OF
THE CITY ENGINEER.
9. EXACT LOCATION OF ALL EQUIPMENT AND CONTROL DEVICES SHALL
BE DETERMINED BY THE CITY ENGINEER. ADDITIONAL WARNING,
CONSTRUCTION SIGNS AND/OR TRAFFIC SAFETY EQUIPMENT MAY BE
REQUIRED BY THE CITY ENGINEER. LOCATION OF ALL EQUIPMENT IS
SUBJECT TO FINAL APPROVAL AND MAY BE MODIFIED BY THE CITY
ENGINEER.
10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN
BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT
ALL TIMES.
11. ALL WORK AREAS SHALL BE CLEARLY IDENTIFIED AND DELINEATED
WITH CONES, PORTABLE DELINEATORS AND/OR BARRICADES. ALL
CONES OR PORTABLE DELINEATORS SHALL BE A MINIMUM OF 28
INCHES IN HEIGHT.
12. ALL SIGNS SHALL BE REFLECTORIZED OR ILLUMINATED.
13. TRAFFIC SIGN DIMENSIONS, COLOR AND LETTERING SHALL CONFORM
TO THE LATEST CALTRANS SIGN SPECIFICATION SHEETS.
14. SIGNS SHALL NOT BE PLACED IN SHADOWS OR OBSTRUCTED
LOCATIONS.
15. THE BOTTOM OF ALL POST MOUNTED SIGNS SHALL BE SEVEN (7)
FEET ABOVE FINISHED SURFACE.
16. SIGNS SHALL NOT BE PLACED IN EXCESS OF 15 FEET FROM THE EDGE
OF THE TRAVELLED WAY. PORTABLE SIGN STANDARDS SHALL BE
TIED DOWN OR WEIGHTED DOWN WITH SAND BAGS TO PREVENT TOPPLING.
17. ALL EXISTING SIGNS THAT ARE IN CONFLICT AND/OR NO LONGER
APPLICABLE WITH THIS PLAN SHALL BE COVERED OR REMOVED.
18. ALL EXISTING STRIPING AND PAVEMENT MARKINGS THAT ARE IN
CONFLICT AND/OR ARE NO LONGER APPLICABLE WITH THIS PLAN
SHALL BE COVERED OR REMOVED.
19. THE WORK ZONE SHALL BE ROUTINELY INSPECTED AND MAINTAINED
TO ENSURE PROPER VISIBILITY AND OPERATION OF ALL TRAFFIC
CONTROL AND ADVANCE WARNING DEVICES.
20. ALL FLASHING YELLOW WARNING LIGHTS SHALL BE TYPE "A"
PORTABLE, LENS DIRECTED, ENCLOSED AND MOUNTED AT A MINIMUM
HEIGHT OF THREE FEET, MEASURED FROM THE BOTTOM OF THE LENS
TO THE UNDERLYING SURFACE.
21. ALL FLASHING YELLOW WARNING LIGHTS SHALL BE IN ACCORDANCE
WITH W.A.T.C.H. LATEST EDITION.
22. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF
PROJECT SHALL BE IN PLACE ONE WEEK PRIOR TO IMPLEMENTING
DETOURS.
DATE STREET RECONSTRUCTION
RANDALL AVE, TO MERRILL AVE.
MERRILL AVE.
350' 350'
o � 13 La
z � r
i
0 N V=x tom. x
U ... z 00 o
^ U
J x
3
. I.
L T
• o M i C5
�, / ( ®LT
� 1 � (.t� x.@►) 30r31bMr8 ill 3dA1 � (LT)
C41 r r-ra
y CS—L
;o z nw a x°.p 0 (48"x 18")
I i
X pOgC x r _ (60
!a `.o o / i -so
I , 250 _ I. 250 _i i
- (I
I
I w I
' I
I U)
. I�' I
wI
�'I ,� 200, 200
/ p W t~1 0 M
V) W °' O�W ^°x a x
0= V w (~�, Q V� r W
US) a0
Iso Mir
ATHOL STREET �
.
.......i
,� D y W ..
X nA xs n = O Q1 D j.
/
w
31'
C D X m O Q J F_
o Ij < �C(3{ 0,,v 1 c W �p D m v
v 1 fC.1 A' v 0 I w
I
2001 200
I I
I' co
' Cid
I � w
i CL
I►
I i
I� AREA OF I
' CONSTRUCTION
C5—R I
II (48"x 18")
Rowe cuEO / �
TYPE 111 BARRICADE C3 -A
I i.s-x 24�
I a-s
RANDALL AVE. I (w'71®
I /
D Q
0
DIAL TWO WORKING
BEFORE DAYS BEFORE
YOU DIG YOU DIG
TOLL FREE 1-800-422-4133
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
-L C5
® (RT)
C5 -R
(48"x 18")
ROAD
CLOSED
AHEAD
I C19
(36"x 36")
ROAD
CONSTRUCTION
AHEAD
C18
(48"x 48")
DATE STREET CLOSED
TO THRU TRAM
RANDALL VENUE
TO AVENUE
FROM
(60"x 30")
0
N
i C5
I DETOUR Q (
CS—SST)
'HOL STREET
350' 350'
I Z I _ e �W _ O _ dell ,.
f i � A
Q00
H ,tt�i�
U v c a �� �o
1 � m
I co
^ 2 12
x
In10
v
'i Cs
oeTouR [� (ST)
C5—S
i
I DATE STREET CLO.
RA RMTRIVQ
AYEM
W_ TO _
(60"x 30")
I
0
N
QROFESSION
LU
No. C 40964
Exp. 3-31-99
9� CIVIL
F OF CAI.\'o
DATE STREET CLOSED
TO THRU TRAFFIC
FROM RANDALL AVENUE
TO MERRILL AVENUE
FROM TO
(60"X 30"
ROAD
CLOSED
AHEAD
C19
ROAD
CONSTRUCTION
\\ AHEAD //
mms
TYPE III BARRICADE
ROAD CLOSED
TO THRU
TRAFFIC
C3 -A
DETOUR
C5—S
DETOUR
C5—L
DETOUR
C5—R
ALL CONSTRUCTION SIGNS TO BE POST MOUNTED ON 4x4
POSTS AND INSTALLED PER CALTRANS STANDARDS,
UNLESS OTHERWISE SHOWN.
FOR LANE CLOSURES, FLASHING ARROW BOARDS SHALL BE
REQUIRED AND TAPERS INSTALLED PER THE W.A.T.C.H. MANUAL.
BARRICADES SHALL BE MOUNTED WITH TYPE A, LOW INTENSITY
FLASHING WARNING LIGHTS.
FOR ADDITIONAL INFORMATION REGARDING TRAFFIC CONTROL
AND TRAFFIC DETOUR SEE SPECIAL PROVISIONS SECTION 7.10.3
AND SECTION "E" OF THE SPECIAL PROVISIONS.
RECORD DRAWING
Prepared Under The Supervision or : CITY OF FONTANA, CALIFORNIA
COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION
DRAW E F.s. DATE STREET PAVEMENT RECONSTRUCTION SCALE: AS SHOWN
DESIGNED BY: DETOUR PLAN DATE: 1N198
� " E.F.S.
�wu'1Date : l�lb/g9 APP D BY: DRAWING NO.: 6
CHECKED BY: Le) A
FELIPE U. MOUNOS, R.C.E. 40964 E.L. CIT TRAFFIC ENGINEE .C.E. 26690 DATE: 270 6
REV. REVISION DESCRIPTION DATE ENGR. CITY DATE
0
N
QROFESSION
LU
No. C 40964
Exp. 3-31-99
9� CIVIL
F OF CAI.\'o
DATE STREET CLOSED
TO THRU TRAFFIC
FROM RANDALL AVENUE
TO MERRILL AVENUE
FROM TO
(60"X 30"
ROAD
CLOSED
AHEAD
C19
ROAD
CONSTRUCTION
\\ AHEAD //
mms
TYPE III BARRICADE
ROAD CLOSED
TO THRU
TRAFFIC
C3 -A
DETOUR
C5—S
DETOUR
C5—L
DETOUR
C5—R
ALL CONSTRUCTION SIGNS TO BE POST MOUNTED ON 4x4
POSTS AND INSTALLED PER CALTRANS STANDARDS,
UNLESS OTHERWISE SHOWN.
FOR LANE CLOSURES, FLASHING ARROW BOARDS SHALL BE
REQUIRED AND TAPERS INSTALLED PER THE W.A.T.C.H. MANUAL.
BARRICADES SHALL BE MOUNTED WITH TYPE A, LOW INTENSITY
FLASHING WARNING LIGHTS.
FOR ADDITIONAL INFORMATION REGARDING TRAFFIC CONTROL
AND TRAFFIC DETOUR SEE SPECIAL PROVISIONS SECTION 7.10.3
AND SECTION "E" OF THE SPECIAL PROVISIONS.
RECORD DRAWING
Prepared Under The Supervision or : CITY OF FONTANA, CALIFORNIA
COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION
DRAW E F.s. DATE STREET PAVEMENT RECONSTRUCTION SCALE: AS SHOWN
DESIGNED BY: DETOUR PLAN DATE: 1N198
� " E.F.S.
�wu'1Date : l�lb/g9 APP D BY: DRAWING NO.: 6
CHECKED BY: Le) A
FELIPE U. MOUNOS, R.C.E. 40964 E.L. CIT TRAFFIC ENGINEE .C.E. 26690 DATE: 270 6