Loading...
HomeMy WebLinkAbout2665-l-1169263 r ♦a ♦e QQ' �♦ I Co kJ Til., , F --e I �J C?k cp Q C 40 IA/ I P~E✓ l V i 7l4 I S Ate' � ♦e Q e LOT 13 se A G ® O �v m ♦ -O co --D1._ NORTE--------STRE:r- /110 2`` e ~ ♦ �J e♦ ya ki fi LOT 14 e e♦ e♦ ee ee e♦ ee �Cw o� Siuc-ul�u�, IRoV I r lel I i FI -E S Lel E 1i� TP Is v l C-1 I--� I IY L oC^75' M MI Q 1AAAI. INtP/- 7 CCCUP4 . co CO c 70 CONTROLLER NOTE VALVES ARE DESIGNATED TO STATIONS 1 THRU 4, THIS IS FOR AFERENCE ONLY. HOOK VALVES UP TO FIRST AVAILABLE STATIONS ON EXISTING CONTROLLER 111111 STATIC PRESSURE 155.0 MAX., REGULATED TO 85.0 RESIDUAL PRESSURE 6.9 METER SIZE 1" PEAK IRRIGATION DEMAND 30 GPM GPM PER VALVE - REFER TO INDIVIDUAL VALVE 1 (ONE) FINISH GRADE @ BACKFLOW N/A HIGHEST HEAD SERVED N/A PRESSURE CALCS BELOW RIGHT CONNECT TO EXISTING MAINLINE DOWSTREAM OF EXISTING BACKFLOW PREVENTER, AND UPSTREAM OF ANY PRESSURE REGULATING DEVICE THAT MAY EXIST. 4� 1I W I cl.�e G r .1G , CIDP-> P546 -i M CTG -P-- WALL QI LIMIT � WOP*- I Pte`` C I7y OP F�-Ov l bG m m LOT 19 ALIGN Ct)g)� 010 3/4 31� 3 4 I 115 3/4 It 3�4 30 18 LlQuln .5 IF 'ALO ALTO' 15C� AMERICAN SWE[F-T-qUM .Y G I o, G Z o•�`i BASELINE_ City Required Notes I- 1t is the tandiw-" c nt acioes msponsibility to crintad the Engiging iiiv r(z) Lzridscz,pe InIpwAnr, 48 hours prior to desired inspection of an item at extension (3) 35C -~?3 2. Pnor to encase of util�jea a pmaI :ncm�t, Lhe €oo +oun rg insgawoas alt rtgtnred: C =wuction of img"on system in open tench condition (prior Da backfill). Pressure Tell 150 PSI for a three (3) hour continuous Aa fmgation cxn'cr-dam t L Manung. ioduding Arcot tri Cowls : tht P-rk-- P12 ins =3 I ar> cape Developmestt Semon, Emvnerrtag P"15100, lar spectei aDd Rmsh grwck pesos to flooding. Cc+me.;:rte :.itat: arr""'L td 1;mdscape plate. Any special Con6tion I c4'P'% p nom-; 4-1 W%'w----ice. 10 Y 1�^'.,.:L l=int Inspection. ?. T-�zt•raer':; r.sa,anfiYe a.M landpcspe conuvcux shall be present at this 'vlainttnanoe Gui¢clir�r: . I_andscam shaU be maintained in a nein. clean, weed tree and bcA(ty cv"60a. This slh:11! ixi' e, bul rock impi led !tic CWtivs-6m & pLanW bods *t sJ* 4—" to excred tri 1 J 0) dayst 2 Rego "mo %i r4 to r;='n+ a 1 -awn h e ie -r ON 43 -CX M4 (2.);nos y4%1fl vj--y 4. 3. � €?e;o 1Yr` of water n�aary i cr �x l tmw ik i rt i P��►i-w, mx ; q= ,ztad 11"dsc" Ma4%*aMsan CWT - 5 ; :- ate rr-plasx�t of piust mZftn.&a " zteeded due to dea& diae+saa; or 4 ■ ��n on a mguja e a* i AAil, b -j pnxide odor vLarnc ppm. 7 Inxne&*x rewr or mite ernew of icrigabaa nuiterisk W needed to rtt, ISUZm . a �-„�, �yi: �::o...:.� _�? � .�...-tet �,,, ;�;. ��r•� f«L Ties we to be a3jusud to avotd abnmcm or rrt;bag d 9. Upon ccimpieban of ft throe (3) axxWts or c%x (i) year tTaaiWtr>►> w-: poied, Ah i= -;x; sW$ be mode by the Ctvmusuty De ek*cn rA Dopwt mesa real ei2 ri ed i n acror&-m:B :ri w v ' a"+. i' " � -�.= ::: ;"��• cfi c,+� #cr't Maes boodtal itmll be rekased at the exid 4 tix ItM-Ami, max pe.:;.; i;UM 1sd4css ac 4 Nest: i ed ng k:-�r4aaa t� spocifir_atioss.. i_ i s .bondl�.-�2... j.ur tt f r�', � r3, L\' VW•4G�er rsv� �lb-0T IiLStltiCt]ifLQC� iits[�iKiiL � . LOT 18 LOT 14 LOT `A' PLANTING NOTE FINISH GRADE LOT `A' SO THAT SLOPE IS GENTLE AND ROLLING FROM WALL TO BACK OF SIDEWALK. HYDROSEED LOT `A' WITH "MARATHON II" PLANT (1) 1 GALLON PARTHENOCISSUS TRICUSPIDATA (BOSTON IVY) @ 20 O.C. ALONG PERIMETER WALL IN VINE POCKET IN CONCRETE CURB. PLANT PER DETAIL ON SHEET L2. I U U— U U i 3/4 P _ 1" WATER METER 4.3 1 1/2" BACKFLOW PREVENTER 13.0 ELEVATION CAHNGE 2.6 LATERAL LINES 3.3 MAIN LINES - 14.7 FITTINGS (20% OF MAIN LINE) 2.9 1 1/2" VALVE 1.7 TOTAL PSI LOSS 43.1 STATIC WATER PRESSURE 85.0 LESS TOTAL PSI LOSS 43.1 EQUALS MINIMUM TO FARTHEST HEAD 41.9 SPRINKLER OPERATING PRESSURE 3.5.0 RESIDUAL WATER PRESSURE 6.9 LOT 13 i 41 IRRIGATIONNOTES' DIAGRAMMATIC PLAN This system is diagrammatic. All pipe, valves, etc. shown within paved areas are for design ' clarification only and shall be installed in planting areas and joint trenches wherever possible. i SPRINKLER ADJUSTMENT REQUIRED The irrigation contractor shall flush and adjust all sprinkler heads for optimum performance and prevent overspray onto walks and roadways as much as possible. This shall include selecting the best degree of are to fit the existing site conditions. Contractor to use pressure compensating screens when; radius is reduced more than fifty percent (50%). FIELD CONDITIONS Do not willfully install the sprinkler system as indicated on the drawings when it is obvious in the, field that unknown obstructions or grade differences exist and should be brought to the attention of the owner's authorized representative. In the event that this notification is not performed, the Contractor must assume full responsibility for any revisions required. SWING JOINTS Install all heads with double or triple swing joints, using street ells, as per detail. COORDINATED WORK It is the sole responsibility of the irrigation contractor to familiarize himself with all grade differences, location of walls, etc. Contractor shall coordinate his work with the general contractor and other subcontractors, for Iocating pipe sleeves through walls, under roadway paving, etc. MINIMUM PREE"SURE AND MAXIMUM GALLONS REQUIRED The sprinkler system design is based on a minimum operational pressure and a maximum demand at the point of connection, as noted on the plan. Before installing the system, check point of connection and immediately notify Landscape Architect if pressure is not as noted or the required gallons per minute is not available. WATER LINE UNDER PAVING All mainline under paving shall be installed 24" deep. All lateral lines under paving shall be Sch 40 PVC and installed 24" deep. SYSTEM COVERAGE The irrigation contractor is to adjust head locations ih the field in order to guarantee 100% coverage. Contractor to contact the Landscape Architect prior to any major change(s) resulting in additional cost to the owner. IRIM"IGATION LEGEND SYMBOL MFG. MODEL # DESCRIPTION RAD. GPM PSI PATTERN DET. # .0 TORO XP300-P-180-07 STREAM ROTOR 36' . 2.85 35 180 (UNLESS SHT. L2 OTHERWISE NOTED ON PLANS C� EXISTING AUTOMATIC CONTROLLER LOCATION ® EXISTNG BACKFLOW PREVENTION DEVICE . ►� NIBCO T-113 GATE VALVE (LINE SIZE) SHT. L2 PRESSURE REGULATOR - WILKINS 500 SERIES SHT. L2 RAINBIRD PGA SERIES REMOTE CONTROL VALVE (SIZE INDICATED) SHT. L2 Q RAINBIRD 33 DLRC QUICK COUPLING VALVE (INSTALL 6" FROM SHT. L2 HARDSCAPE OR TURF EDGE) PVC CLASS 200 LATERAL LINE (INSTALL WITH 12" COVER IN PLANTING AREAS), ...a.i�. PVC SCH 40 MAINLINE FOR 2" AND SMALLER, PVC CLASS 315 FOR 21/2" AND LARGER (18" COVER IN PLANTING AREAS / 24" COVER UNDER PAVING) SIZES AS INDICATED. IZ PVC SCH 40 MAIN AND LATERAL LINE SLEEVE 2X DIAMETER Or PIPE I PVC SCH 40 WIRE CONDUIT INDICATES CONTROLLER INDICATES VALVE NUMBER INDICATES PRECIPITATION RATE i--�— INDICATES VALVE GPM .INDICATES VALVE SIZE LOT 12 3/4 3/4 3/4 3/g- I ► cz ! 3/� AVENUE G 3 0,4AJ \1'/Z:/T7,1 lei` 2-1, 1 74 >L— N Imo' a%ev- aA� S,4JT Scale 1"=20' � I T E S c A P V Landscape Architecture and Planning 180 Newport Center Drive Suite 210 Newport Beach, CA 92660 Richard Palharnus, License CA -#2782 (714)g 644-•9370 (114) 644-9396 FAX fA TRr*i->e REVISION lea- e -I n 3 zs • t8 1 ' V Z CC 0) Z W(0 N LO Z C\I LLJ Z V LU � �R co 0 LL Z CV V Q� LLJU aC*4 U J 0 Q LU 0 .0 LL LIM a LU U Z Q o � 2 H O LIL ' V Z CC 0) Z W(0 N o �,– C\I w Z V LU � .J0 Q Q Z CV w LLJU aC*4 Z J 0 LU 0 .0 LL LIM O, ti Q z w � r � Q o CY) DVM Z DATE 2/9/98 a Z J � w z W o U am Q 0 Z V QC/) Q D Z Q J DVM CHK DATE 2/9/98 JOB `98-001 L� of 2