HomeMy WebLinkAbout2666-26S C. MAIN ! LINE RCB ;o ;D W BARS I SEE NOTE 3 i ROUND EDGE TO 3'R i STATION POINT. i SEE NOTE 2 i Z+ ,i E � i z , t ON 1 A iv CONSTRUCTION JOINT 4_ LATERAL / CONNECTOR PIPE �-F BARS Q @3 OR •4 0 180 Oc ROUND EDGES TO APPROXIMATE R OF ID OF LATERAL WITH A MAXIMUM OF 3-04 DaEBARS D.E.H81GBARS CONSTRUCTION JOINT LAN 103 OR *Is* 44 0 18` OC BOTH WAYS TO BE USED WHEN B IS 60' OR MORE SECTION--G--G NEW OR EXISTING RCB. SEE NOTE 6 W BARS /�- D BARS -7'-�- PIPE P� J 0! HOAR D F BARS 2-H BARS 4. OC. t - SEE NOTE 3 IV I ROUND 'i EDGES.3 OR *4 ELEV. ❑S 0 I8 0 co ELEV. R. SEE NOTE 8 SEE NOTE 6 E BARS 2-0 BARS 4. OC, SEE NOTE 3 •'. NOTES BARS 1. VALUES FOR A. B AND C SHALL BE SHOWN ON THE PROJECT DRAWINGS. ELEVATION R AND ELEVATION S SHALL BE SHOWN WHEN REQUIRED PER NOTE 8 B T (INCHES) (INCHES) • '' UNDISTURBED EARTH ' a BACKFILL WITH 420-C-2000 MIX 0 ,p CONCRETE. OR COMPACT SOIL TO 18 5 RELATIVE DENSITY REQUIRED BY 24 5 1/4 SPECIFICATIONS. BACKFILL MAY BE 30 6 OMITTED IF STRUCTURE IS LAID ON 36 61/2 UNDISTURBED EARTH TO STORM SEC ION Z -Z DRAIN WALL NOTES BARS 1. VALUES FOR A. B AND C SHALL BE SHOWN ON THE PROJECT DRAWINGS. ELEVATION R AND ELEVATION S SHALL BE SHOWN WHEN REQUIRED PER NOTE 8 B T (INCHES) (INCHES) V) a m c� ab 3 W oU. U) a m 12 5 [-B]MCl 0 ,p 15 5 18 5 21 5 24 5 1/4 27 51/2 30 6 33 6 1/4 36 61/2 39 7 42 71/2 0+42.10 LINE "S" 0 . 45 7 3/4 48 8 51 8 1/2 54 9 57 91/4 60 9 1/2 63 10 66 10 1/4 69 10 3/4 72 11 78 11 3/4 84 121/2 90 13 1/4 78 _ 11 3/4 U 0 4) 4D 96 14 102 151/2 108 16 114 16 1/2 120 17 126 17 132 171/2 138 17 1/2 144 18 AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA STANDARD PLAN PROMULGATED BY THE APWA-AGC JUNCTION STRUCTURE - PIPE TO RCB JOINT COOPERATIV1992E COMMITTEE 333-0 USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION SHEET 1 OF 2 2. STATIONS SPECIFIED ON THE PROJECT DRAWINGS APPLY AT THE INTER- SECTION OF CENTER LINES OF MAIN LINE AND LATERALS. EXCEPT THAT STATIONS FOR CATCH BASIN CONNECTOR PIPES APPLY AT INSIDE WALL OF STRUCTURE. 3. REINFORCING STEEL SHALL CONFORM TO ASTM A 615, GRADE 40, AND SHALL TERMINATE 1 1,,2' CLEAR OF CONCRETE SURFACES UNLESS OTHERWISE SHOWN a. W BARS ARE OF SIZE AND SPACING SPECIFIED FOR WALL STEEL ON PROJECT DRAWINGS, AND SHALL BE CUT IN CENTER OF OPENING AND BENT INTO TOP AND BOTTOM OF JUNCTION STRUCTURE. b. OMIT H BARS WHEN SOFFIT OF SPUR IS 12" OR LESS BELOW SOFFIT OF MAIN LINE AND OMIT G BARS WHEN INVERTOF SPUR IS 12" OR LESS ABOVE FLOOR OF MAIN LINE. 4. JUNCTION STRUCTURE SHALL BE POURED MONOLITHICALLY WITH MAIN LINE, MANHOLE OR TRANSITION STRUCTURE. 5. FLOOR OF STRUCTURE SHALL BE STEEL -TROWELED TO THE SPRING LINE. 6. WHEN CONNECTING TO EXISTING RCB, BREAKOUT LIMITS AND DETAIILS SHALL BE SHOWN ON THE PROJECT DRAWINGS 7. EMBEDMENT, P, SHALL BE 5" FOR B--96" OR LESS AND 8" FOR B OVER 96,'. 8. IF ELEVATION R AND ELEVATION S ARE NOT SHOWN ON THE PROJECT DRAWINGS THEN THE INLET OPENING SHALL FALL 6" BELOW THE SOFFIT OF THE MAIN LINE WITH THE INLET PIPE LAID ON A STRAIGHT GRADE FROM MAIN LINE TO CATCH BASIN OR TO GRADE BREAK IN INLET LINE. ELEVATION S SHALL BE SHOWN ON THE PROJECT DRAWINGS IF THE INLET OPENING FALLS MORE THAN 6" BELOW THE SOFFIT OF THE MAIN LINE WITH THE INLET PIPE LAID ON A STRAIGHT GRADE AS STATED ABOVE. ELEVATION R SHALL BE SHOWN ON THE PROJECT DRAWINGS ONLY WHEN A STUB IS TO BE PROVIDED FOR A FUTURE CONNECTION. 9. LATERALS OR CONNECTOR PIPES 24" OR LESS IN DIAMETER SHALL BE NO MORE THAN 5' ABOVE THE INVERT. LATERALS OR CONNECTOR PIPES 27" OR LARGER IN DIAMETER SHALL BE NO MORE THAN 18" ABOVE THE INVERT. WITH THE EXCEPTION THAT CATCH BASIN CONNECTOR PIPES LESS THAN 50' IN LENGTH SHALL NOT BE MORE THAN 5' ABOVE THE INVERT. 10. THE NEED FOR AN EDGE BEAM AND/OR ADDITIONAL REINFORCEMENT SHALL BE INVESTIGATED BY THE ENGINEER FOR ANY ONE OF THE THE FOLLOWING CONDITIONS: a. ANGLE A IS LESS THAN 30° b. TOP OF INLET PIPE IS LESS THAN 6" BELOW THE SOFFIT c. FLOW LINE OF INLET PIPE IS LESS THAN 7" ABOVE THE FLOOR OF THE RCB AT THE INSIDE FACE AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARDPLAN 333-0 SHEET 2 OF 2 JUNCTION STRUCTURE - PIPE TO RCB JUNCTION STRUCTURE PIPE TO RCB LINES STATION ELEV [-B]MCl 12 4 v 0 ® v 0 ;a 4 L & J 0+28.24 LINE "J" 1618.87 48" 300 10' 36 " 8 " 6/_05 /8// S & T 0+42.10 LINE "S" 1524.92 36"1 41018'17 " 6-5/1 4' -8 " ROUND EDGES TO RADIUS OF APPROXIMAT_ ID OF LATERAL. MAXIMUM 36'- TABLE 6'- TABLE FOR DIMENSIONS AND BAR SIZES D2 E OR OR B T (INCHES)(INCHES) mad m a a go o o a 12 4 v 0 ® v 0 ;a 4 ;3 15 4 1!4 18 1 4 1/2 21 5 24 51/4 27 51/2 30 6 33 61/4 36 61/2 39 7 42 71/2 0 A 00 57 0 tO 45 7 3/4 48 8 51 81/2 54 9 9 1/4 60 9 1/2 63 10 66 101/4 4' -6" 69 10 3/4 72 11 78 _ 11 3/4 84 12 1/2 90 13 1/4 0 M 0 96 14 102 15 1/2 108 16 114 16 1/2 120 17 126 17 132 17 1/2 138 117 I/2 144 IS ABB BAR P SEE NOTE 8 STAT10NL�f STATION PT. ❑S • 3 OR +4 0 180 OC 6a N M D BARS PLAN a w N . 14 4. LATERAL / CONNECTOR PIPE XROU3 D KEDGES P 93 OR *4. SEE NOTE 4 03 OR 94 LONGITUDINAL SECTION A BARS 4. F BARS:�-- ! I / 4. MAIN LINE STATION 0 V OC. BOTH ,Tn 1 .a. TO BE USED WHEN D2 IS 60' OR MORE D BARS @3 OR •4 P 03 OR #4 I °a 0 I8' OC B BARS f ELEV. R ELEV. f � 040I8' OC. BOTH WAYS. TO BE USED WHEN B IS 60' OR MORE 1p C. MAIM LINE SECTION N' -Nu� N" PROJECTED ON M -M -Nm AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA STANDARD PLAN PROMULGATED BY THE APWA-AGc TRANSITION STRUCTURE - PIPE TO PIPE JOINT COOPERATIVE COMMITTEE 1992 `'/� 0 -(1�0JJ► USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION SHEET 1 OF 2 NOTES 1. THE HORIZONTAL ANGLE OF CONVERGENCE OR DIVERGENCE. 8. SHALL NOT EXCEED 5045'. 2. VALUES FOR A, B. C, D, AND D ARE SHOWN ON THE PROJECT DRAWINGS. ELEVATION R AND EHVATION S ARE SHOWN WHEN REQUIRED BY NOTE 10. 3. FLOOR OF STRUCTURE SHALL BE STEEL TROWELED TO SPRING LINE. 4. REINFORCEMENT STEEL SHALL CONFORM TO ASTM A 615, GRADE 40, AND SHALL TERMINATE 11/2' CLEAR OF CONCRETE SURFACES UNLESS OTHERWISE SHOWN. LONGITUDINAL BARS SHALL BE #3 OR #4 SPACED 18" OC OR LESS. 5. ELEVATION S APPLIES AT INSIDE WALL OF STRUCTURE. 6. TRANSITION STRUCTURE SHALL BE POURED IN ONE CONTINUOUS OPERATION, EXCEPT THAT THE CONTRACTOR SHALL HAVE THE OPTION OF PLACING AT THE SPRING LINE A CONSTRUCTION JOINT LONGITUDINAL KEYWAY. 7. THE LENGTH OF THE STRUCTURE MAY BE INCREASED AT THE OPTION OF THE CONTRACTOR TO MEET RCP ENDS, USING D BARS, LONGITUDINAL AND BOTTOM REINFORCEMENT IN EXTENDED PORTION OF SAME DIAMETER AND SPACING AS SPECIFIED IN THE TABLE BUT ANY CHANGE IN THE LOCATION OF SPUR MUST BE APPROVED BY THE ENGINEER. 8. EMBEDMENT P SHALL BE AS SPECIFIED IN THE TABLE. UNLESS OTHERWISE SHOWN ON THE PROJECT DRAWINGS. 9. WHEN THERE IS NO SPUR REQUIRED, A & B BARS SHALL BE OMITTED. 10. WHEN ELEVATION R AND ELEVATION S ARE NOT SHOWN ON PROJECT DRAWINGS, INLET PIPE SHALL ENTER MAIN LINE RADIALLY. WHEN INLET PIPE ENTERS MAIN LINE OTHER THAN RADIALLY, ELEVATION S SHALL BE SHOWN ON PROJECT DRAWINGS, AND INLET PIPE SHALL BE LAID ON A STRAIGHT GRADE FROM ELEVATION S TO CATCH BASIN GRADE BREAK IN INLET LINE. ELEVATION R SHALL BE SHOWN ON PROJECT DRAWINGS ONLY WHEN STUB IS TO BE PROVIDED IN MAIN LINE FOR FUTURE CONSTRUCTION OF INLET PIPE. 11. THE MAXIMUM COVER ABOVE THE STRUCTURE SHALL BE 25'. IF THE COVER EXCEEDS 25' A SPECIAL STRUCTURE SHALL BE DESIGNED FOR THE COVER AND DETAILED ON THE PROJECT DRAWINGS. AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN 340-0 SHEET 2 OF 2 TRANSITION STRUCTURE - PIPE TO PIPE TRANSITION STRUCTURE PIPE TO PIPE LINES ELEV STAT ION20 ELEV3Q STATION4� STATION50 ELEV S❑ B❑ �� Q � D� DQ QC G1 & G3 1572.51 0+40.00 LINE "G1" 1572.60 0+47.00 LINE "G1 " 0+41-00 LINE "G1" 1572-67 24" 22010'33" 51/4/' 51/4' 18" 24" 4' -6" AS BUILT DWG. FEB, 2000 z:\server\dgn\o79-41st\dgn\ junctionb