Loading...
HomeMy WebLinkAbout2666-254. MAIN LINE RCP OR REINFORCED MONOLITHIC ARCH, SEE NOTE 2- w J 0 a V w I. - w V z 0 V SPUR REINFORCING STEEL 3' MIN. i� SPRING LINE f �ROUNI) Ak EDGE: ` ELEV.I INV. ELEV. P21. � UNDISTURBED EARTH H H R. -t - SECTION Z -Z i l mSTA. POINT LATERAL SEE NOTE 3 PLAN -•3 OR @4 0 18' OC TIE BARS G BARS •4 0 6. OC f` L i N a r . J ELEV. R ;B3 RSC 5 r r F BARS #5 0 3' OC CONCRETE CRADLE. 420-C-2000. SEE NOTE 9 46 LATERAL/ CONNECTOR PIPE G BARS 406. OC 03 OR 84 ®18. OC TIE BARS E AND F BARS 05 0 3' OC. SEE NOTE 8 TABLE OF VALUES FOR T B (INCHES) T (INCHES) 12 5 15 5 1e 5 21 5 24 31/2 27 51/2 30 6 33 61/2 36 61/2 39 7 SECTION M -M BARS G BARS AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA PROMULGATED BY THE APWA-AGC JUNCTION STRUCTURE - PIPE TO PIPE STANDARD PLAN JOINT COOPERATIVE COMMITTEE (INLET I D?24 OR OD>le2 MAIN LINE I D ) 3 31-1 1992 LINE "Z5" STA 0+03.00 USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION B&A3 SHEET 1 OF 2 NOTES 1. THIS JUNCTION STRUCTURE SHALL BE USED WHEN THE OUTSIDE DIAMETER OF THE LATERAL IS GREATER THAN 1/2 THE INSIDE DIAMETER D OF THE MAIN LINE; OR WHEN THE INSIDE DIAMETER B OF THE LATERAL IS GREATER THAN 240, B SHALL NOT EXCEED 3/4 D OR 39". 2. IF THE MAIN LINE IS A REINFORCED MONOLITHIC ARCH STORM DRAIN, D SHALL REFER TO THE CLEAR SPAN OF THE ARCH. REINFORCING STEEL SHALL BE CUT AND BENT INTO THE JUNCTION STRUCTURE IN THE SAME MANNER AS FOR A PIPE. A CONCRETE CRADLE IS NOT REQUIRED FOR A REINFORCED MONOLITHIC ARCH. 3. STATIONS SHOWN ON THE PROJECT DRAWINGS FOR LATERALS APPLY AT THE INTERSECTION OF CENTER LINES OF MAIN LINE AND LATERAL. STATIONS SHOWN ON THE PROJECT DRAWINGS FOR CATCH BASIN CONNECTOR PIPES APPLY AT THE INTERSECTION OF THE INSIDE WALL OF THE MAIN LINE WITH THE CONNECTOR PIPE CENTER LINE. 4. VALUES FOR A, B, C AND D SHALL BE SHOWN ON THE PROJECT DRAWINGS. ELEVATIONS R AND ELEVATION S SHALL BE SHOWN ONLY WHEN REQUIRED PER NOTE 5. 5. a. ELEVATIONS R AND S NEED NOT BE SHOWN ON THE PROJECT DRAWINGS IF THE INLET PIPE IS TO ENTER THE MAIN LINE RADIALLY. b. ELEVATION R SHALL BE SHOWN THE PROJECT DRAWINGS ONLY IF A STUB IS TO BE PROVIDED IN THE MAIN LINE FOR FUTURE CONNECTION OF AN INLET PIPE. c. ELEVATION S SHALL BE SHOWN ON THE PROJECT DRAWINGS IF AN INLET PIPE IS TO ENTER THE MAIN LINE OTHER THAN RADIALLY. INLET PIPE SHALL BE LAID ON A STRAIGHT GRADE FROM ELEVATION S TO THE CATCH BASIN OR GRADE BREAK IN LINE. 6. THE INLET PIPE SHALL ENTER THE MAIN LINE RADIALLY UNLESS OTHERWISE INDICATED. THE INLET PIPE MAY ENTER THE MAIN LINE OTHER THAN RADIALLY IF ANGLE A IS GREATER THAN 4509 B IS LESS THAN OR EQUAL TO 24"AND THE OUTSIDE DIAMETER OF THE INLET PIPE IS LESS THAN 1/2 D: OTHERWISE, STANDARD PLAN 340 SHALL BE USED. 7. NO MORE THAN ONE OPENING SHALL BE MADE IN ANY ONE SECTION OF PIPE. 8. THE OPENING FOR THE BREAKOUT SHALL BE RECTANGULAR AND CUT NORMAL TO THE PIPE SURFACE WITHOUT DAMAGING THE REINFORCING STEEL. THE TRANSVERSE REINFORCEMENT OF THE MAIN LINE SHALL BE CUT AT THE CENTER OF THE OPENING AND BENT INTO THE TOP AND BOTTOM SLABS OF THE SPUR. 9. THE MAIN LINE SHALL BE REINFORCED WITH A CONCRETE CRADLE AND ENCASEMENT (AS APPLICABLE). A CONCRETE ENCASEMENT IS REQUIRED IF A JOINT IN THE MAIN LINE FALLS WITHIN THE LIMITS OF THE CRADLE. THE CONCRETE ENCASEMENT SHALL EXTEND 12" ABOVE THE TOP OF THE MAIN LINE AND TO THE LIMITS OF THE CRADLE. IF CONNECTING TO AN EXISTING STORM DRAIN, PORTION OF CRADLE OPPOSITE INLET MAY BE OMITTED. 10. REINFORCING STEEL SHALL CONFORM TO ASTM A 615. GRADE 409 AND BE PLACED 11/2" CLEAR FROM CONCRETE SURFACES. UNLESS OTHERWISE SHOWN F BARS SHALL BE CARRIED TO A POINT NOT LESS THAN J DISTANCE FROM THE CENTER LINE WITH J = 7D/12 + 6". 11. FLOOR OF THE SPUR SHALL BE STEEL -TROWELED TO THE SPRING LINE OF THE SPUR AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN 331-1 SHEET 2 OF 2 JUNCTION STRUCTURE � PIPE TO PIPE ( INLET I D_24 OR OD> 2 MAIN LINE I D ) JUNCTION STRUCTURE PIPE TO PIPE ID ->24" LINES STA POINT Fil ELEV[S] INV ELEV FA -1 F -B] [-Dl LINE "Z5" STA 0+03.00 FC -1 B&A3 LINE "B" STA 0+38.91 1576.55' 1575.80' 90000,00" 24 " 42 " 5.5 " 21// C&E LINE "C" STA 0+54.64 1 1577.65' 1 1576.88' *920 11' 55" 1 24" 42" 5.5"1 21 " I * MEASURED BETWEEN � OF LATERAL AND TANGENT LINE AT STA. 0+54-649 LINE "C" t LATERAL /CONNECTOR PIPE - t MAIN LINE RCP CLASS C MOR T�,R �_L CASE I PLAN CONC. PIPE, RCP OR CSP C.MAIN LINE RCP-~--� 4• j ,W � f--� ar N 1/2' MIN. SEE NOTE 4 BEDDING OF INLET PIPE 4B.445 , BACKFILL WITH r '� .e �'• •'- SEE NOTE 6 420-C-2000 > CONCRETE OR _• •••• •..a �• INV ELEV COMPACT SOIL. TO `•" :'• RELATIVE DENSITY z REQUIRED BY ' , INV ELEV [3 SPECIFICATIONS UNDISTURBED EARTH MOM- 7 BEDDING. PER SPECIFICATIONS CASE I SECTION B -B / FOR OUTLET SEE STD. r CATCH BASIN PLANS a a� CATCH BASIN FLOOR p0 420-C-2000 1/2 OD MIN. . •:> , �• CONC. ENCASE T. } SEE NOTE 5 CONC. PIPE.�•:'' :'•� BACKFILL •• .'.�, • a • RCP OR CSP tr SEE NOTE 3 BEDDING I/2• MIN. SEE NOT4 /OD -- _ 113>450- _-- CASE 2 TO SUIT ONS MAS E.: 3 :ADDLE CONNECTION CASE I SECTION C -C CLASS C MORTAR AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA STANDARD PLAN 332-0 SHEET 2 OF 2 JUNCTION STRUCTURE PIPE TO PIPE STANDARD PLAN PROMULGATED BY THE APWA-AGC JOINT COOPERATIVE COMMITTEE a t I D� 24 ) Z3&Z5 LINE "Z5" STA 0+03.00 332-01992 1543.11' 30°01'04" USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION SHEET 1 OF 2 NOTES CASE 1 AND CASE 2 1. IF ANGLE A IS LESS THAN 45° OR IF DIS LARGER THAN 24", THEN ANOTHER STANDAR STRUCTURE SHALL BE SPECIFIED 2. THE OUTSIDE DIAMETER OF THE INLET PIPE SHALL NOT EXCEED ONE-HALF THE INSIDE DIAMETER OF THE MAIN LINE. 3. THE INLET PIPE SHALL ENTER THE MAIN LINE RADIALLY. IF THE INLET PIPE CANNOT ENTER RADIALLY, THEN ANOTHER STANDARD STRUCTURE SHALL BE SPECIFIED. 4. THE SIZE OF THE OPENING INTO THE MAIN LINE SHALL BE THE OUTSIDE DIAMTER OF THE INLET PIPE PLUS 1" MINIMUM TO 3" MAXIMUM 5. ALL CONNECTOR PIPES FOR CASE2 SHALL BE ENCASED IN CONCRETE IF LAID WITHIN THE MAIN LINE EXCAVATED TRENCH OR IF LAID ON FILL WHICH HAS NOT BEEN DENSIFIED. 6. BURN OR CHIP END OF CONNECTOR PIPE FLUSH WITH INNER SURFACE OF MAIN LINE. ROUND EDGE OF CONCRETE PIPE OR RCP. 7. ALL CSP FITTINGS SHALL BE GALVANIZED 8. STATION SPECIFIED ON THE PROJECT DRAWINGS APPLIES AT THE INTERSECTION OF THE INSIDE WALL OF MAIN LINE AND THE CENTER LINE OF INLET PIPE. 9. CASE 2 SHALL NOT BE USED TO CONNECT TO THE FLOOR OF A GRATING CATCH BASIN WHERE THE GRATE WILL BE SUBJECT TO VEHICLE TRAFFIC. 10. FOR CASE 2, NOT MORE THAN 12' OF INLET PIPE SHALL BE LOCATED WITHIN THE MAIN LINE EXCAVATED TRENCH. CASE 3 11. CONNECTIONS TO PIPES 21" OR LESS IN DIAMETER WITHOUT JUNCTION STRUCTURES OR PRECAST Y BRANCHES SHALL BE MADE WITH SADDLE. 12. THE OUTSIDE DIAMETER OF THE INLET PIPE SHALL NOT EXCEED ONE-HALF THE INSIDE DIAMETER OF THE MAIN LINE. 13. TRIM OR CUT SADDLE TO FIT SNUGLY OVER THE OUTSIDE OF THE MAIN LINE SO ITS AXIS WILL BE ON THE LINE AND GRADE OF THE CONNECTOR PIPE 14. THE OPENING INTO THE PIPE SHALL BE CUT AND TRIMMED TO FIT THE SADDLE SO THAT NO PART WILL PROJECT WITHIN THE BORE OF THE MAIN SADDLE PIPE 15. THE CONNECTOR PIPE SHALL BE SUPPORTED AS SHOWN IN CASES 1 AND 2 AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN 332-0 SHEET 2 OF 2 JUNCTION STRUCTURE,� P IPE TO PIPE ( I D�24 ) ^I JUNCTION STRUCTURE PIPE TO PIPE ID<_24" LINES STA POINT 1❑ ELEV INV ELEV FA-1FD_l Z3&Z5 LINE "Z5" STA 0+03.00 1543.86' 1543.11' 30°01'04" 24" "AS BUILT" DWG. FEB. 2000 z,.\server\dgn\o79-41st\dgn\ junctiona.dgn