HomeMy WebLinkAbout2666-254. MAIN LINE RCP OR
REINFORCED MONOLITHIC
ARCH, SEE NOTE 2-
w
J
0
a
V
w
I. -
w
V
z
0
V
SPUR
REINFORCING STEEL
3' MIN.
i�
SPRING
LINE
f �ROUNI)
Ak
EDGE:
`
ELEV.I
INV. ELEV. P21. �
UNDISTURBED
EARTH
H H
R. -t -
SECTION Z -Z
i
l mSTA. POINT
LATERAL
SEE NOTE 3
PLAN
-•3 OR @4 0 18' OC
TIE BARS
G BARS
•4 0 6. OC f`
L
i
N a
r . J
ELEV. R
;B3 RSC 5
r
r
F BARS #5
0 3' OC
CONCRETE CRADLE.
420-C-2000.
SEE NOTE 9
46 LATERAL/
CONNECTOR PIPE
G BARS
406. OC
03 OR 84 ®18. OC
TIE BARS
E AND F BARS
05 0 3' OC.
SEE NOTE 8
TABLE OF
VALUES FOR T
B
(INCHES)
T
(INCHES)
12
5
15
5
1e
5
21
5
24
31/2
27
51/2
30
6
33
61/2
36
61/2
39
7
SECTION M -M
BARS
G BARS
AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA
PROMULGATED BY THE APWA-AGC
JUNCTION STRUCTURE - PIPE TO PIPE
STANDARD PLAN
JOINT COOPERATIVE COMMITTEE
(INLET I D?24 OR OD>le2 MAIN LINE I D )
3 31-1
1992
LINE "Z5" STA 0+03.00
USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
B&A3
SHEET 1 OF 2
NOTES
1. THIS JUNCTION STRUCTURE SHALL BE USED WHEN THE OUTSIDE DIAMETER
OF THE LATERAL IS GREATER THAN 1/2 THE INSIDE DIAMETER D OF THE
MAIN LINE; OR WHEN THE INSIDE DIAMETER B OF THE LATERAL IS GREATER
THAN 240, B SHALL NOT EXCEED 3/4 D OR 39".
2. IF THE MAIN LINE IS A REINFORCED MONOLITHIC ARCH STORM DRAIN,
D SHALL REFER TO THE CLEAR SPAN OF THE ARCH. REINFORCING STEEL
SHALL BE CUT AND BENT INTO THE JUNCTION STRUCTURE IN THE SAME
MANNER AS FOR A PIPE. A CONCRETE CRADLE IS NOT REQUIRED FOR A
REINFORCED MONOLITHIC ARCH.
3. STATIONS SHOWN ON THE PROJECT DRAWINGS FOR LATERALS APPLY AT THE
INTERSECTION OF CENTER LINES OF MAIN LINE AND LATERAL. STATIONS
SHOWN ON THE PROJECT DRAWINGS FOR CATCH BASIN CONNECTOR PIPES
APPLY AT THE INTERSECTION OF THE INSIDE WALL OF THE MAIN LINE WITH
THE CONNECTOR PIPE CENTER LINE.
4. VALUES FOR A, B, C AND D SHALL BE SHOWN ON THE PROJECT DRAWINGS.
ELEVATIONS R AND ELEVATION S SHALL BE SHOWN ONLY WHEN REQUIRED PER
NOTE 5.
5. a. ELEVATIONS R AND S NEED NOT BE SHOWN ON THE PROJECT DRAWINGS
IF THE INLET PIPE IS TO ENTER THE MAIN LINE RADIALLY.
b. ELEVATION R SHALL BE SHOWN THE PROJECT DRAWINGS ONLY IF A
STUB IS TO BE PROVIDED IN THE MAIN LINE FOR FUTURE CONNECTION
OF AN INLET PIPE.
c. ELEVATION S SHALL BE SHOWN ON THE PROJECT DRAWINGS IF AN INLET
PIPE IS TO ENTER THE MAIN LINE OTHER THAN RADIALLY. INLET PIPE
SHALL BE LAID ON A STRAIGHT GRADE FROM ELEVATION S TO THE
CATCH BASIN OR GRADE BREAK IN LINE.
6. THE INLET PIPE SHALL ENTER THE MAIN LINE RADIALLY UNLESS OTHERWISE
INDICATED. THE INLET PIPE MAY ENTER THE MAIN LINE OTHER THAN
RADIALLY IF ANGLE A IS GREATER THAN 4509 B IS LESS THAN OR EQUAL TO
24"AND THE OUTSIDE DIAMETER OF THE INLET PIPE IS LESS THAN 1/2 D:
OTHERWISE, STANDARD PLAN 340 SHALL BE USED.
7. NO MORE THAN ONE OPENING SHALL BE MADE IN ANY ONE SECTION OF PIPE.
8. THE OPENING FOR THE BREAKOUT SHALL BE RECTANGULAR AND CUT NORMAL
TO THE PIPE SURFACE WITHOUT DAMAGING THE REINFORCING STEEL. THE
TRANSVERSE REINFORCEMENT OF THE MAIN LINE SHALL BE CUT AT THE
CENTER OF THE OPENING AND BENT INTO THE TOP AND BOTTOM SLABS OF
THE SPUR.
9. THE MAIN LINE SHALL BE REINFORCED WITH A CONCRETE CRADLE AND
ENCASEMENT (AS APPLICABLE). A CONCRETE ENCASEMENT IS REQUIRED IF A
JOINT IN THE MAIN LINE FALLS WITHIN THE LIMITS OF THE CRADLE. THE
CONCRETE ENCASEMENT SHALL EXTEND 12" ABOVE THE TOP OF THE MAIN
LINE AND TO THE LIMITS OF THE CRADLE.
IF CONNECTING TO AN EXISTING STORM DRAIN, PORTION OF CRADLE
OPPOSITE INLET MAY BE OMITTED.
10. REINFORCING STEEL SHALL CONFORM TO ASTM A 615. GRADE 409 AND BE
PLACED 11/2" CLEAR FROM CONCRETE SURFACES. UNLESS OTHERWISE
SHOWN F BARS SHALL BE CARRIED TO A POINT NOT LESS THAN J
DISTANCE FROM THE CENTER LINE WITH J = 7D/12 + 6".
11. FLOOR OF THE SPUR SHALL BE STEEL -TROWELED TO THE SPRING LINE OF
THE SPUR
AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER
STANDARD PLAN
331-1
SHEET 2 OF 2
JUNCTION STRUCTURE � PIPE TO PIPE
( INLET I D_24 OR OD> 2 MAIN LINE I D )
JUNCTION STRUCTURE PIPE TO PIPE ID ->24"
LINES
STA POINT Fil
ELEV[S]
INV ELEV
FA -1
F -B]
[-Dl
LINE "Z5" STA 0+03.00
FC -1
B&A3
LINE "B" STA 0+38.91
1576.55'
1575.80'
90000,00"
24 "
42 "
5.5 "
21//
C&E
LINE "C" STA 0+54.64
1 1577.65'
1 1576.88'
*920 11' 55"
1 24"
42"
5.5"1
21 "
I * MEASURED BETWEEN � OF LATERAL AND TANGENT LINE AT STA. 0+54-649 LINE "C"
t LATERAL /CONNECTOR PIPE
- t MAIN LINE RCP
CLASS C
MOR T�,R
�_L
CASE I
PLAN
CONC. PIPE, RCP OR CSP
C.MAIN LINE RCP-~--�
4• j
,W � f--�
ar
N
1/2' MIN.
SEE NOTE 4
BEDDING OF
INLET PIPE 4B.445 ,
BACKFILL WITH r '� .e �'• •'-
SEE NOTE 6
420-C-2000 >
CONCRETE OR _• •••• •..a �•
INV ELEV
COMPACT SOIL. TO `•" :'•
RELATIVE DENSITY z
REQUIRED BY ' , INV ELEV [3
SPECIFICATIONS
UNDISTURBED EARTH MOM- 7
BEDDING. PER
SPECIFICATIONS
CASE I
SECTION B -B
/ FOR OUTLET SEE STD.
r CATCH BASIN PLANS
a a�
CATCH BASIN FLOOR p0
420-C-2000
1/2 OD MIN. . •:> , �•
CONC. ENCASE T. }
SEE NOTE 5
CONC. PIPE.�•:'' :'•�
BACKFILL •• .'.�, • a
• RCP OR CSP tr
SEE NOTE 3 BEDDING
I/2• MIN.
SEE NOT4
/OD
-- _ 113>450- _--
CASE 2
TO SUIT
ONS
MAS E.: 3
:ADDLE CONNECTION
CASE I
SECTION C -C
CLASS C MORTAR
AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA
STANDARD PLAN
332-0
SHEET 2 OF 2
JUNCTION STRUCTURE PIPE TO PIPE
STANDARD PLAN
PROMULGATED BY THE APWA-AGC
JOINT COOPERATIVE COMMITTEE
a
t I D� 24 )
Z3&Z5
LINE "Z5" STA 0+03.00
332-01992
1543.11'
30°01'04"
USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
SHEET 1 OF 2
NOTES
CASE 1 AND CASE 2
1. IF ANGLE A IS LESS THAN 45° OR IF DIS LARGER THAN 24", THEN
ANOTHER STANDAR STRUCTURE SHALL BE SPECIFIED
2. THE OUTSIDE DIAMETER OF THE INLET PIPE SHALL NOT EXCEED
ONE-HALF THE INSIDE DIAMETER OF THE MAIN LINE.
3. THE INLET PIPE SHALL ENTER THE MAIN LINE RADIALLY. IF THE
INLET PIPE CANNOT ENTER RADIALLY, THEN ANOTHER STANDARD
STRUCTURE SHALL BE SPECIFIED.
4. THE SIZE OF THE OPENING INTO THE MAIN LINE SHALL BE THE
OUTSIDE DIAMTER OF THE INLET PIPE PLUS 1" MINIMUM TO 3"
MAXIMUM
5. ALL CONNECTOR PIPES FOR CASE2 SHALL BE ENCASED IN CONCRETE
IF LAID WITHIN THE MAIN LINE EXCAVATED TRENCH OR IF LAID ON
FILL WHICH HAS NOT BEEN DENSIFIED.
6. BURN OR CHIP END OF CONNECTOR PIPE FLUSH WITH INNER SURFACE
OF MAIN LINE. ROUND EDGE OF CONCRETE PIPE OR RCP.
7. ALL CSP FITTINGS SHALL BE GALVANIZED
8. STATION SPECIFIED ON THE PROJECT DRAWINGS APPLIES AT THE
INTERSECTION OF THE INSIDE WALL OF MAIN LINE AND THE CENTER
LINE OF INLET PIPE.
9. CASE 2 SHALL NOT BE USED TO CONNECT TO THE FLOOR OF A
GRATING CATCH BASIN WHERE THE GRATE WILL BE SUBJECT TO
VEHICLE TRAFFIC.
10. FOR CASE 2, NOT MORE THAN 12' OF INLET PIPE SHALL BE LOCATED
WITHIN THE MAIN LINE EXCAVATED TRENCH.
CASE 3
11. CONNECTIONS TO PIPES 21" OR LESS IN DIAMETER WITHOUT JUNCTION
STRUCTURES OR PRECAST Y BRANCHES SHALL BE MADE WITH SADDLE.
12. THE OUTSIDE DIAMETER OF THE INLET PIPE SHALL NOT EXCEED ONE-HALF
THE INSIDE DIAMETER OF THE MAIN LINE.
13. TRIM OR CUT SADDLE TO FIT SNUGLY OVER THE OUTSIDE OF THE MAIN LINE
SO ITS AXIS WILL BE ON THE LINE AND GRADE OF THE CONNECTOR PIPE
14. THE OPENING INTO THE PIPE SHALL BE CUT AND TRIMMED TO FIT THE
SADDLE SO THAT NO PART WILL PROJECT WITHIN THE BORE OF THE MAIN
SADDLE PIPE
15. THE CONNECTOR PIPE SHALL BE SUPPORTED AS SHOWN IN CASES 1 AND 2
AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER
STANDARD PLAN
332-0
SHEET 2 OF 2
JUNCTION STRUCTURE,� P IPE TO PIPE
( I D�24 )
^I
JUNCTION STRUCTURE PIPE TO PIPE ID<_24"
LINES
STA POINT 1❑
ELEV
INV ELEV
FA-1FD_l
Z3&Z5
LINE "Z5" STA 0+03.00
1543.86'
1543.11'
30°01'04"
24"
"AS BUILT" DWG. FEB. 2000
z,.\server\dgn\o79-41st\dgn\ junctiona.dgn