HomeMy WebLinkAbout2657-5FINISHED GRADE IN TURF AREAS FINISHED GRADE IN TURF AREAS FINISH GRADE SHRUB ADAPTER SPRAY HEAD, SEE LEGEND INSTALL SPRINKLER HEAD FLUSH WITH
PLASTIC RECTANGULAR VALVE BOX WITH BOLT DOWN PLASTIC RECTANGULAR VALVE BOX WITH BOLT DOWN R P DEVICE SEE LEGEND FOR SPECIFICATION . FINISHED GRADE IN TURF AREAS
COVER, USE STAINLESS BOLT, NUT, AND WASHER. FOR SPECIFICATION
BOX TO BE PLACED AT RIGHT ANGLE TO HARDSCAPE COVER, USE STAINLESS BOLT, NUT, AND WASHER. — SCH 80 PVC NIPPLE, SIZE PER INLET
EDGE. HEAT BRAND "F5' ONTO LID. BOX TO BE PLACED AT RIGHT ANGLE TO HARDSCAPE BRASS BALL VALVE TYP. LENGTH AS REQUIRED. 2 REQUIRED POP-UP SPRINKLER HEAD, SPRAY OR ROTOR
EDGE. HEAT BRAND MI ONTO LID. SEE LEGEND FOR SPECIFICATION
FLOW SENSOR. SEE LEGEND FOR SPECIFICATION CONTROL VALVE, SEE LEGEND FOR SPEC. GENI '-"• 0 moon* BRASS NIPPLES MIN. 4" TYP.
1 REQUIRED
ANTI -DRAIN VALVE WHERE REQUIRED
I J
BRASS ELL, 4 REQ
_ war,�
— _ -�-- FINISHED GRADE IN SHRUB AREAS -♦--- FINISHED GRADE IN SHRUB AREAS BACKFLOW ENCLOSURE 1F SPECIFIED tk MIN. Ir
p
OR AS srTE INSTALL SPRINKLER HEAD 1 i'
— I g6l!» PRESSURE REGULATOR OR WYE RE4uIREs VANDAL -PROOF CLAMP USE IN 3 PLACES (�� I� i _ _ II
Z@
MIN. ( 4 MIN. STRAINER IF SPECIFIED, SEE BELOW _ ABOVE FINISHED GRADE IN SHRUB
— 24» WIRE LOOP — " ( EBAR STAR 2 REQUIRED 4 X 3C' LENGTH AND GROUND COVERS AREAS
I I�. 24 WIRE LOOP BRASS UNION, Z REQUIRED � E• � ( r I I � I I
VIA PVC MAINLINE PIPE VALVE ID TAGS 1 �' MIN. BRASS RISERS LENGTH AS REQ.
PER SPECISIFICATION
. - PVC SCH 40 FEMALE .. , • . •.. ULTRA -VIOLET RESISTANT PVC STREET ELLS, � ` ! I I I � UNDISTURBED SOIL
�- ADAPTER, 2 REQUIRED
E31• • • 2 REQUIRED, AND - UVR PVC TEE OR ELL PRE -ASSEMBLED TRIPLE SWING JOINT,
MIN' 2" MI PVC MAINLINE TO FLOW 1 g' ULTRA -VIOLET RESISTANT SCH 40 PVC TYPE WITH 0 -RINGED JOINTS,
° o °
SENSOR, PIPE PER SPECS. PVC MAINLINE TO MASTER VALVE PVC PIPE, SEE PLANS FOR SIZE LMAIPT LENGGTTHATO E OUTLET
MIIN UM
° o BRICK SUPPORTS B ° BRICK SUPPORTS SCH 80 PVC FEMALE ADAPTER
SIZE AS PER SPRINKLER OUTLET
LANDSCAPE FABRIC BRASS UNION SCH 80 PVC NIPPLE 6" MIN.W1- FINISH GRADE SCH 40 PVC SxSxT TEE FRYING
CUBIC FT. BRASS NIPPLE TYP. CONCRETE SLAB, SEF BELOW � � � � � � LATERAL x SPRINKLER INLET SIZE
3/4 ROCK, 2 .
--�— #4 x 1 g" REBAR J -HOOK SPACE LATERAL UNE, SEE SPECIFICATIONS
LANDSCAPE FABRIC' PVC MAINLINE I _ FOR TYPE AND DEPTH REQUIRED
PVC MAINLINE PIPE TO MASTER VALVE " AT 10' ON CENTER, TYPIC�►L
PER SPECS. AND PLAN. 3/4 ROCK, 2 CUBIC FT. NOTE:
SECTION YIEW - N.I.S. PVC MAINLINE PIPE FROM NOTE: ,
BACKFLOW PER SPECS. IF WYE STRAINER OR PRESSURE REGULATOR IS SPECIFIED. INSTALL ON EITHER THE ALL PIPE INSTALLED ON GRADE TO BE SCH 40 ULTRA -VIOLET RESISTANT PVC. NOTE;
NOTE: HORIZONTAL PIPING OR ON THE DOWNSTREAM LEG AS SPACE PERMITS.
INSTALL FLOW SENSOR AS PER THE MANUFACTURER'S RECOMMENDATIONS, WIRE TO �F.CIIQN VIEW - N.T_S_ SPRINKLER HEAD ASSEMBLY TO BE INSTALLED PLUMB.
INSTALL SPRINKLER HEADS I' FROM PAVING EDGE IN GROUND COVER AREAS.
IRRIGATION CONTROLLER. N0 CONCRETE SLAB SHALL BE MINIMUM 4" THICK, 1 g' WIDE AND EXTEND AT LEAST 8" DO NOT INSTALL SPRINKLER HEAD ASSEMBLY CLOSER THAN 36' TO SIDEWALXS, INSTALL SPRINKLER HEADS 4" FROM PAVING EDGE IN TURF AREAS.
USE 45 DEGREE ELLS TO ACHIEVE MAINLINE DEPTH ON THE DOWN -STREAM SIDE USE 45 DEGREE ELLS TO ACHIEVE MAINLINE DEPTH FROM UP -STREAM SIDE OF PAST THE BACKFLOW ASSEMBLY PIPING. IF BACKFLOW ENCLOSURE IS SPECIFIED CURBS. DRIVEWAYS OR PEDESTRU�N AREAS. INSTAR SPRINKLER HEADS PLUMB. ADJUST SPRAYS OR NOZZLE STREAM TO COVER
OF THE FLOW SENSOR. THE MASTER VALVE ASSEMBLY. IN THE LEGEND, THE CONCRETE SLAB SHALL. BE THE SIZE REQUIRED BY THE MANUFAC RER.
LANDSCAPE AREA WITHOUT OVERSPRAY ONTO PAVING, FENCES, WALLS OR BUILDINGS.
E FLOW SENSOR D - MASTER VALVE C - BACKFLOW ASSEMBLY B - SPRINKLER ONGRADE A - POP-UP SPRINKLER
FINISH GRADE IN TURF AREAS FINISHED GRADE IN TURF AREAS FINISHED GRADE IN TURF AREAS
PLASTIC RECTANGULAR VALVE BOX WITH BOLT DOWN PLASTIC ROUND VALVE BOX WITH BOLT DOWN PLASTIC ROUND VALVE BOX WITH BOLT DOWN IRRIGATION NOTES N OTE:
COVER USE STAINLESS BOLT NUT AND WASHER COVER, USE STAINLESS BOLT NUT AND WASHER. COVER USE STAINLESS BOLT NUT AND WASHER
' HEAT BRAND QC1r' ONTO UD. HEAT BRAND "GY' ONTO UD. 1. DRAWINGS ARE DIAGRAMMATIC. ALL EQUIPMENT THIS DETAIL IS FOR IDENTIFYING HANDICAP SIGNAGE, SYMBOLS AND
BOX TO BE PLACED AT RIGHT ANGLE TO HARDSCAPE
EDGE. NEAT BRAND "RCY AND CONTROL STATION ONTO UD. SHOWN IN PAVED AREAS ARE FOR DESIGN STRIPES ONLY. PARKING LOT LAYOUT, STALLS AND RAMP PER S.P.
QUICK COUPLER KEY WITH MALE HOSE BIB CLARIFICATION ONLY AND SHALL BE INSTALLED IN CONSULTING GROUP.
CONNECTION AS SHOWN, KEY MUS CLEAR VALVE BOX FINISHED GRADE IN SHRUB AREAS PLANTING AREAS. THE CONTRACTOR SHALL LOCATE ALL
-
_FINISHED GRADE - - VALVES IN SHRUB AREAS. AVOID ANY CONFLICTS
IN SHRUB AREAS �' +- FINISHED GRADE IN SHRUB AREAS IV GATE VALVE W/HAND WHEEL BETWEEN THE SPRINKLER SYSTEM, PLANTING AND WHEEL STOP " PEDESTRIAN ROUTE
49 MIN. (� I I ARCHITECTURAL FEATURES. IRRIGATION CONTRACTOR48 MIN.
4" MIN. SHALL REVIEW PLANTING PLANS PRIOR TO INSTALLATION. �� �-- 70 SQ. INCH
24 WIRE LOOP ACCESS161LITY SIGN
I PVC CL. 160 PIPE 2. 11' IS THE RESPONSIBILITY OF THE IRRIGATION 1:12
TAG o0 0CONTRACTOR T FAMI FAMILIARIZE HIMSELF WITH ALL GRADE MAX. PER SEC. ,3107A(C)
VALVE D QUICK COUPLER VALVE 0 L .
LATE- ow PVC THD. ELL SCH 80 PVC SEE LEGEND FOR SPEC. �e DIFFERENCES, LOCATION OF WALLS, RETAINING WALLS, o SLOPE 1:8 MAX.
STAINLESS STEEL CLAMP 60 00'' STRUCTURES AND UTILITIES. THE IRRIGATION LID
r MIN. CONTROL VALVE � � � SIDE SLOPE
FEMALE ADAP. o BRICK SUPPORTS CONTRACTOR SHALL REPAIR OR REPLACE ALL ITEMS
E BRICK SUPPORTS • B • DAMAGED BY HIS WORK. HE SHALL COORDINATES HIS - Q -
,..CH. 80 PVC SCH 80 PVC NIPPLE TYP• o •000 �0• WORK WITH OTHER CONTRACTORS FOR THE LOCATION .Z -s
BRICK SUPPORTS DURA PRE -ASSEMBLED SWING JOINT o�•e �O�dJO ONE CUBIC FOOT I AND INSTALLATION OF PIPE SLEEVES AND LATERALS
WITH 0 E PIECE BRASS MIPT NIPPLE 0000 ate �o °.0• 3/4" CRUSHED GRAVEL THROUGH WALLS, UNDER ROADWAYS AND PAViiJG,•ETC.1
MOD. r 1-A1912 O �jo• O
SCH. 80 UNION—MAlNUN SEE SPECS. C> 0•C o� • p�o SCH 40 PVC COUPLING 3. INSTALL ALL MATERIALS IN ACCORDANCE WITH STRIPES AT
E` �ooGb.o 0•dJoo0 i APPLICABLE CODES, ORDINANCES, MANUFACTURERS 36 ON CENTER
IRRIGATION MAINLINE 4 x 36' REBAR STAKES. • •.o o..
REQUIRED � INSTRUCTIONS, DETAILS AND SPECIFICATIONS.
,IRRIGATION MAINLINE
» LANDSCAPE FABRIC 4. PRIOR TO COMMENCEMENT OF WORK, THE CONTRACTOR TYP. PAVEMENT
?410
4 CRUSHED GRAVEL SHALL CONTACT THE LANDSCAPE ARCHITECT AND SYMBOL PER
SEC. 3107A C
CUBIC FEET 3/4" ROCK. 1 CUBIC FT. COORDINATE ALL INSPECTIONS.
SECTION VIEW - N.T.S_ SCH 80 PVC T.O.E. 9'-O" MIN. 9'-0" MIN.
LANDSCAPE FABRIC NOTE: SECTION VIEW - N.T.S. NIPPLE I' LONG 5. CONTRACTOR SHALL PROVIDE 100% COVERAGE WITH
SECTION VIEW N_T.S_ USE TER -ON TAPE ON ALL THREADED FITTINGS TYPICAL
MINIMAL OVERSPRAY ONTO NON -PLANTED AREAS.
-' 8'-O"MIN. AT VAN
6. THE CONTRACTOR SHALL PROVIDE AND KEEP UP TO DATE ACCESSIBLE
A COMPLETE RECORD SET OF PRINTS WHICH SHALL BE PARKING STALL
CORRECTED DAILY AND SHOW EVERY CHANGE FROM THE
ORIGINAL DRAWINGS. BEFORE THE TIME OF THE FINAL
INSPECTION, THE CONTRACTOR SHALL TRANSFER ALL
INFORMATION FROM THE SET TO AN "AS -BUILT" SET ON
A REPRODUCIBLE MYLAR SEPIA, PROCURED FROM THE - - -
F -GATE VALVE LANDSCAPE ARCHITECT. ALL WORK SHALL BE NEAT AND
H — CONTROL VALVE G - QUICK COUPLER LEGIBLE. 3107A (c) Identification of Parking Spaces for Off -Street -Parking Facilities. Each
parking space reserved for persons with physical disabilities shall be identified b a
7. THE IRRIGATION CONTRACTOR SHALL VERIFY WATER p g p p p y y
-- PRESSURES PRIOR TO CONSTRUCTION. REPORT ANY reflectorized sign permanently posted immediately adjacent to and visible from each stall or
DIFFERENCE BETWEEN THE WATER PRESSURE INDICATED space, consisting of a profile view of a wheelchair with occupant in white on dark blue
ON THE DRAWINGS AND THE ACTUAL PRESSURE READING background.- The sign shall not be smaller than 70 square inches in area and, when in a path
STAINLESS STEEL ENCLOSURE AT THE IRRIGATION POINT OF CONNECTION TO THE of travel, shall be posted at a minimum height of 80 inches from the bottom of the sign to the
SEE LEGEND FOR SPECIFICATION OWNERS AUTHORIZED REPRESENTATIVE. -
parking space finished grade. Signs may also be centered on the wall at the interior end of
FINISH GRADE RAIN SHUT-OFF DEVICE, REFER TO 8. DO NOT WILLFULLY INSTALL THE SPRINKLER SYSTEM AS the parking space at a minimum height of 36 inches from the parking space finished grade,
LEGEND FOR SPECIFICATION SHOWN ON THE DRAWINGS WHEN IT IS OBVIOUS IN THE ground or sidewalk. Spaces complying with Section 3107A (b) 2 shall have an additional
-III III- FIELD THAT UNKNOWN OBSTRUCTIONS, PRESSURE OR
CLEAN COMPACTED BACKFILL sign stating "Van -Accessible" mounted below the symbol of accessibility.
GRADE DIFFERENCES OR DIFFERENCES IN THE ARE
I i -I I III i IRRIGATION CONTROLLER DIMENSIONS EXIST AND SHOULD BE BROUGHT TO THE __ ._ _.
B C ATTENTION OF THE OWNER'S AUTHORIZED An additional sign shall also be posted in a conspicuous place at each entrance to off-street
=III -III- III III= GFl TYPE SWITCH
LATERAL LINES, SEE SPECS. O W ON-OFF SWITCH REPRESENTATIVE. IN THE EVENT THIS NOTIFICATION IS parking facilities, or immediately adjacent to and visible from each stall or space. The sign
III -I /
NOT PERFORMED, THE IRRIGATION CONTRACTOR SHALL shall not be less than 17 inches by 22 inches in size with lettering not less than 1 inch in
.III --I I1: I I I I I I- ,,RESPONSIBILITYD Y E
TERMI STRIP AND ASSUME FULL FOR REVISIONSheight,c clean
WIRES SEE SPECS, which y and conspicuously states the following:
III I
CONTROL CONTROL WIRES NECESSARY.
v 1" PVC ELECTRICAL SWEEP FOR 9. ALL MAIN LINE PIPING AND CONTROL WIRES UNDER "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing
:III III III III III= p p
III III I III UNDISTURBED SOIL FLOW SENSOR WIRES PAVING SHALL BE INSTALLED IN SEPARATED SLEEVES AND placards or license plates issued for persons with disabilities may be towed away at owner's
PRESSURE MAINLINE, SEE EPDXY SEALANT WITH A 24" MINIMUM COVER. MAIN LINE SLEEVE SIZE expense. Towed vehicles may be reclaimed at �` - - EI'T Y of FONTANA'/
SHALL BE A MINIMUM OF TWICE (ZX) THE DIAMETER OF ` T _ _ _ _ _ _� _ _ _ _ _ R-_1
:III III III SPECIFICATIONS - - - - - - - - -
I I I CONCRETE PAD AS PER CONTROLLER THE PIPE TO BE SLEEVED. CONTROL WIRE SLEEVES _ _ _ or by telephoning _ PER CI_Y OF_FONTANI�_ _
III III - SHALL BE OF SUFFICIENT SIZE FOR THE REQUIRED
:III III .III �.� III III= ENCLOSURE MANUFACTURER'S SPECS. NUMBER OF WIRES UNDER PAVING. TAPE ENDS OF Blank spaces are to be filled in with appropriate information as a permanent part of the sign..
�� � i � � ( � � ! � � � � � � � � � f � � � .•,. • .,... SLEEVES WITH MAGNETIC TAPE FOR EASE IN LOCATING.
• :.
FINISH GRADE In addition to the above requirements, the surface of each accessible parking space or stall
•' -r ' 10. ALL LATERAL LINE PIPING UNDER PAVING SHALL BE PVC shall have a surface identification duplicating either of the following schemes:
UUNNIL I AJ rtK MANUrALA UKtK .�11-"%J IVI^ I oC rlrrnU V tL1. ALL UAMAUELJ AND REJECTED L. L7y Vullllllll� a �J1 V111G V1GW V1 t[ W11GG1Calt111 Wllll UGGUIJii[1[ ill W1111,G Vil UIUG vaG1��1ULUlu.
PIPE SHALL BE REMOVED FROM THE SITE AT THE TIME OF The profile view shall be located- so that it is visible to a traffic. enforcement officer when a
SECTION VIEW N.T.S. SECTION VIEW - N.T.S_ SAID REJECTION.
vehicle is properly parked in the space and shall be 36 inches high by 36 inches wide. See
12. FINAL LOCATION OF THE BACKFLOW PREVENTER AND Figures Nos. 31-18A through C.
AUTOMATIC CONTROLLER SHALL BE APPROVED BY _
OWNER'S AUTHORIZED REPRESENTATIVE.
13. 120 VAC ELECTRICAL POWER SOURCE AT THE
CONTROLLER LOCATION SHALL BE PROVIDED BY THE M - HANDICAP PARKING
OWNER. THE IRRIGATION CONTRACTOR SHALL MAKE THE
JFINAL CONNECTION FROM THE ELECTRICAL SOURCE TO SIGNAGE & NOTES
-PIPE INSTALLATION i -CONTROLLER THE CONTROLLER. _
i
14. ALL SPRINKLER HEADS SHALL BE SET PERPENDICULAR TO
FINISH GRADE UNLESS OTHERWISE SPECIFIED. THE
IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL
SPRINKLER HEADS AND VALVES FOR OPTIMUM
COVERAGE WITH MINIMAL OVERSPRAY ONTO WALKS,
STREETS, WALLS, ETC.
LOW VOLTAGE WIRES, 3 MAXIMUM
i
15. THE IRRIGATION CONTRACTOR SHALL INSTALL ANTI -
DRAIN VALVES (TO PREVENT EXCESSIVE DRAINAGE FOR
OUTER CASE OF CONNECTOR , ' ; , ' .� •• • ' •••' ' ,•'; ; • ' • •., .. PAVING LOW HEADS) ON ALL HEADS IN SYSTEMS WHERE FINISH
- GRADE EXCEEDS 5 FEET.
III I, ' • �• _I
• • SAND BACKFILL COMPACTEDI
16. ALL IRRIGATION LINES CROSSING DRAINAGE SWALES
TO THE DENSITY OF SHALL BE GALVANIZED SCHEDULE 40 ONE SIZE LARGER
III I C B I I THAN SPECIFIED VC PIPE. EXTEND PAST EDGE OF
_ _ EXISTING SOIL P
LATERAL LINES
• '' '''•'''•'•'•''' SWALE MINIMUM OF 12".
.I1M I
I:.
E- — IN SCH 40 SLEEVE 17. ALL CONTROLLERS Ii
III I S ALL BE INSTALLED WITH A RAIN
I_
- _ GUARD, AUTOMATIC RAIN SHUT OFF DEVICE FROM
a I I _ CONTROL WIRES W.C.S. CLAREMONT, CA. (714) 621-5805. LOCATED ON
IN SCH 40 SLEEVE
III III I III I SIDE OF CONTROLLER HOUSING WITH PIPE ELBOW
UNDISTURBED SOIL EXPOSED TO UNOBSTRUCTED RAINFALL AND CLEAN OF
III III I I I III I I _ IRRIGATION SPRAY. IF NECESSARY, PROVIDE 11/2" i
III III PRESSURE MAINLINE GALVANIZED PIPE EXTENTION, LENGTH AS REQUIRED TO
IN SCH 40 SI.EEYE
11ri IIII IIEl II=
STRIP AND TWIST WIRES FOR PROPER PVC SLEEVES TO BE
CONNECTIONIII III
El III TWICE THE D
it I i III III III III III � I I III III= E IAMETER
OF THE PIPE OR WIRE
fI LAM nnnnrn e•1 O-1-%"- 1►IrrA I I rn al lunt r C`>DDIrr%
WITH RECOMMENDED TOOL
DIMENSION
A
B
C
C
I_ . ' . •� ' . ,.
- J" PVC ELECTRICAL. SWEEP FOR
-' LOW VOLTAGE CONTROL WIRES
1" PVC ELECTRICAL SWEEP FOR
SCHEDULE 40 PIPE AND SHALL BE INSTALLED PRIOR TO
PAVING, MIN. 24" COVER.
11. PIPE SIZES SHALL CONFORM TO THOSE SHOWN ON THE
1. By outlining or painting the stall or space in blue and outlining on the ground in the stall
or space in white or suitable contrasting color a profile view depicting a wheelchair with
1/2" TO 2-1/7' IN SIZE
1 ar
12'
4"
.
1 10 VOLT POWER. WIRES
3/4" X 96' COPPER GROUND ROD
T ww..•.r~W. •A rI .•..a.r.A-Id %rr%
DRAWINGS. NO SUBSTITUTIONS OF SMALLER PIPE SIZES
SHALL BE PERMITTED, BUT SUBSTITUTIONS OF LARGER-
C17ffn RAAV nr- Arnnr�r%,,-� ... .•. .. �.«� _ _._ __.—_--
occupant; or j
11 ' ice_. _..al:��_..,.
3i' TO G' IN SIZE
24"
4"
4"
UUNNIL I AJ rtK MANUrALA UKtK .�11-"%J IVI^ I oC rlrrnU V tL1. ALL UAMAUELJ AND REJECTED L. L7y Vullllllll� a �J1 V111G V1GW V1 t[ W11GG1Calt111 Wllll UGGUIJii[1[ ill W1111,G Vil UIUG vaG1��1ULUlu.
PIPE SHALL BE REMOVED FROM THE SITE AT THE TIME OF The profile view shall be located- so that it is visible to a traffic. enforcement officer when a
SECTION VIEW N.T.S. SECTION VIEW - N.T.S_ SAID REJECTION.
vehicle is properly parked in the space and shall be 36 inches high by 36 inches wide. See
12. FINAL LOCATION OF THE BACKFLOW PREVENTER AND Figures Nos. 31-18A through C.
AUTOMATIC CONTROLLER SHALL BE APPROVED BY _
OWNER'S AUTHORIZED REPRESENTATIVE.
13. 120 VAC ELECTRICAL POWER SOURCE AT THE
CONTROLLER LOCATION SHALL BE PROVIDED BY THE M - HANDICAP PARKING
OWNER. THE IRRIGATION CONTRACTOR SHALL MAKE THE
JFINAL CONNECTION FROM THE ELECTRICAL SOURCE TO SIGNAGE & NOTES
-PIPE INSTALLATION i -CONTROLLER THE CONTROLLER. _
i
14. ALL SPRINKLER HEADS SHALL BE SET PERPENDICULAR TO
FINISH GRADE UNLESS OTHERWISE SPECIFIED. THE
IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL
SPRINKLER HEADS AND VALVES FOR OPTIMUM
COVERAGE WITH MINIMAL OVERSPRAY ONTO WALKS,
STREETS, WALLS, ETC.
LOW VOLTAGE WIRES, 3 MAXIMUM
i
15. THE IRRIGATION CONTRACTOR SHALL INSTALL ANTI -
DRAIN VALVES (TO PREVENT EXCESSIVE DRAINAGE FOR
OUTER CASE OF CONNECTOR , ' ; , ' .� •• • ' •••' ' ,•'; ; • ' • •., .. PAVING LOW HEADS) ON ALL HEADS IN SYSTEMS WHERE FINISH
- GRADE EXCEEDS 5 FEET.
III I, ' • �• _I
• • SAND BACKFILL COMPACTEDI
16. ALL IRRIGATION LINES CROSSING DRAINAGE SWALES
TO THE DENSITY OF SHALL BE GALVANIZED SCHEDULE 40 ONE SIZE LARGER
III I C B I I THAN SPECIFIED VC PIPE. EXTEND PAST EDGE OF
_ _ EXISTING SOIL P
LATERAL LINES
• '' '''•'''•'•'•''' SWALE MINIMUM OF 12".
.I1M I
I:.
E- — IN SCH 40 SLEEVE 17. ALL CONTROLLERS Ii
III I S ALL BE INSTALLED WITH A RAIN
I_
- _ GUARD, AUTOMATIC RAIN SHUT OFF DEVICE FROM
a I I _ CONTROL WIRES W.C.S. CLAREMONT, CA. (714) 621-5805. LOCATED ON
IN SCH 40 SLEEVE
III III I III I SIDE OF CONTROLLER HOUSING WITH PIPE ELBOW
UNDISTURBED SOIL EXPOSED TO UNOBSTRUCTED RAINFALL AND CLEAN OF
III III I I I III I I _ IRRIGATION SPRAY. IF NECESSARY, PROVIDE 11/2" i
III III PRESSURE MAINLINE GALVANIZED PIPE EXTENTION, LENGTH AS REQUIRED TO
IN SCH 40 SI.EEYE
11ri IIII IIEl II=
STRIP AND TWIST WIRES FOR PROPER PVC SLEEVES TO BE
CONNECTIONIII III
El III TWICE THE D
it I i III III III III III � I I III III= E IAMETER
OF THE PIPE OR WIRE
fI LAM nnnnrn e•1 O-1-%"- 1►IrrA I I rn al lunt r C`>DDIrr%
WITH RECOMMENDED TOOL
DIMENSION
A
e
C
D
urvavr.r- vI"1.NN6.v•
DETAIL ALSO FOR PIPE
1 /Z" TO 4" IN SIZE
31'
24"
24"
4"
CONNECTOR INSERT
INSTALLED IN ROCK SOIL.
NOTE: SECTION VIEW - N.T. ,
FILL OUTER CASE WITH SEALER PRIOR TO FINAL ASSEMBLY.
REV DATE DESCRIPTION
APPROVED BY CITY OF FONTANA
25126
ROBERTWED RCE DATE
CRY ENGINEER
My Authority Expires
MAINTAIN. CLEAR SPACE INSTALL PER MANUFACTURER'S
NOTE: PERFORM ALL WORK TO COMPLY SPECIFICATIONS.
WITH 1994 UBC WITH GA. AbMENDMENTS fig, SEE IRRIGATION DETAIL SHEET 410•1 FOR ASSEMBLIES
& 1993 NEG WITH CA. ADMENDMENTS AND REFER TO THE SPECIFICATIONS MANUAL FOR
ADDITIONAL INFORMATION.
WILDERNESS PARK
TRACT 13750 -LOT E1
ACTUAL ADDRESS TO BE
ASSIGNED BY THE CITY OF I
FONTANA BLDG. &SAFETY I
DEPT.
L - WIRE CONNECTIONS K SLEEVE INSTALLATION
0
30315 CANWOCO SitR = - SU r 10
AGOURA HILLS. CAL'FORNIA 91301
1(818) 38? -99004 FAX6- (8181 889-0007
192 E. CE. F AVE. - SUI C 100
SANTA ANA CAUFCRNIA 92705
(714) 251-96E5 FAX. (7141 251-0657
S;gnvnue �. •
v
Ctv�
0
CZ
o
v�
01 Q
U
, � Z
n
* o
CD
t~
Z CA
�z
IrU �
Revisions
10-29-97 CITY P.C. REVISIONS
12-7-97 CITY P.C. REVISIONS
12-30-97 CITY P.C. REVISIONS
1-21-98 CITY P.C. REVISIONS
Date JUNE 26, 199%
orcrwn by
St,ee� nn,
IRRIGATION
DETAILS
Sheet No.
LIDs 1
S OF 40
O